PCMM System Specifications Leica Absolute Tracker and Leica T-Products

Similar documents
PCMM System Specifications Leica Absolute Tracker and Leica T-Products

Leica Absolute Tracker AT401 Absolutely portable

LEICA ABSOLUTE TRACKER AT960

LEICA ABSOLUTE TRACKER AT960

Leica TDRA6000 Product Brochure

PRODUCT BROCHURE SCANNING SOLUTIONS PORTABLE LASER SCANNING WITH THE LEICA ABSOLUTE TRACKER

Leica Absolute Trackers

Leica TM6100A Industrial Theodolite Product Brochure

Leica Laser Tracker Want the Whole Picture? Go Portable CMM.

Alignment Services LLC

DCP Pocket for Leica TDRA6000 Mobile and ruggedized large-volume metrology package

LEICA ABSOLUTE TRACKER AT960

AICON MoveInspect XR8

LEICA ABSOLUTE TRACKER AT403

Leica Absolute Tracker AT901 Product Brochure

Leica Industrial Theodolites & Total Stations Precision in Large-Scale Measurement

ROMER ABSOLUTE ARM ADVANCED PORTABLE 3D MEASUREMENT PRODUCT BROCHURE

DATA SHEET DEA GLOBAL SILVER 09.XX XX.10

EXPLORER CLASSIC BRIDGE COORDINATE MEASURING MACHINE PRODUCT BROCHURE

Leica Rugby 320 SG & 410/420 DG The toughest players on big fields. Construction Machine Control Agriculture

Leica Rugby 320 SG & 410/420 DG The toughest players on big fields

THE OPTICAL PORTABLE CMM FOR INDUSTRIAL APPLICATIONS

Non-Contact Thickness Measurement

PRODUCT BROCHURE TIGO SF. 3D coordinate measuring machine for the shop floor

METROLOGY SOLUTIONS THE OPTICAL PORTABLE CMM FOR INDUSTRIAL APPLICATIONS

nconstruction nmachine Control nagriculture Leica Rugby 320 SG & 410/420 DG The toughest player on the field

Roll angle in 6DOF tracking. CMSC Charlotte-Concord, July 2008

THE ROBOT-MOUNTED OPTICAL CMM 3D SCANNERS FOR AUTOMATED INSPECTION

Guideways X axis Precision-manufactured, anodized extruded profile made of light metal. On stabilized, welded steel supports

BLAZE 600M HIGH-ACCURACY BLUE LIGHT MEASUREMENT SYSTEM PRODUCT BROCHURE

PRODUCT BROCHURE DEA MICRO-HITE. Handy and Cost-Effective CMM

The world s most versatile pipe laser

SP25M The world s most compact and versatile scanning probe system

DEA TORO Horizontal-Arm Coordinate Measuring Machines

R0 in µm THP in µm 18 C - 22 C

X=2000 Z=2000 X=2000 Z=1600. E0/E150 in µm L/ L/ L/ L/ L/ L/400. R0 in µm

THE ROBOT-MOUNTED OPTICAL CMM 3D SCANNERS FOR AUTOMATED INSPECTION

Axes 150 mm/s 150 mm/s. Y axis Z axis Vector 260 mm/s 260 mm/s. P in µm P in µm

GEOMETRICAL SURVEY OF COMPACT ANTENNA TEST RANGES USING LASER TRACKER TECHNOLOGY

Optically jointed probing systems for large volume coordinate metrology. Stephen Kyle

Temperature dry-well calibrator Models CTD9100-COOL, CTD , CTD , CTD

FARO QUANTUM S FAROARM & FARO QUANTUM S SCANARM HD The Global Standard for Arm Technology

Complete 3D measurement solution

Optimized Design of 3D Laser Triangulation Systems

501, , 1052, , 1602, 1604 EXCEL EXCEL 1602UC EXCEL 1052UC EXCEL 501HC. Micro-Vu Corporation. Precision Measurement Systems

Helium-Neon Laser Heads 1100 Series

Helium-Neon Laser Heads 1100 Series

Rotary Position Technology Incremental Encoders

The FaroArm. The world s best-selling measurement arm

COMPARISON OF ERROR MAPPING TECHNIQUES FOR COORDINATE MEASURING MACHINES USING THE PLATE METHOD AND LASER TRACER TECHNIQUE

Temperature dry-well calibrator Models CTD9100-COOL, CTD , CTD , CTD

Hexagon Metrology WLS qflash

leica industrial theodolite

Geometry Measurements

LASER SOLUTIONS. Ensure Accurate Setup from Simulation to Treatment. MOVEABLE: CT SIM+ // FIXED: MICRO and MICRO+

ZEISS COMET LƎD 2 Simple and quick 3D measurements. The new, mobile system for optical 3D scanning

Length, Germany, PTB (Physikalisch-Technische Bundesanstalt)

Gregory Walsh, Ph.D. San Ramon, CA January 25, 2011

T-SCAN 3 3D DIGITIZING

Keysight Technologies Transducer Systems. Leading the Future for Extreme Accuracy Positioning Applications

Helium-Neon Laser Heads Series

GET A WHOLE new measure OF things!

Leica Rugby 810, 820 & 840 The toughest construction lasers on site

Helium-Neon Laser Heads 1100 Series

COMPACT RANGE CALIBRATION AND ALIGNMENT

S-650 Coupling Alignment System

Micro-Hite Handy and Cost-Effective CMM

Field Metrology Wells

Geomagic Leica Tracker Plug-In 1.0 User s Manual

Accuracy for CMMs and Machine Tools

Genesis MX STM-Series

HP-L-8.9 LASER SCANNER

Z-LASER Improved Beam Modeling With Optical Fibers. Vision Technology Forum April 15th, 2015

Leica Rugby 810, 820 & 840 The toughest construction lasers on site

Leica Geosystems Measure, align, level

ACCURA adjusts to your needs and can be upgraded without complications

ISO INTERNATIONAL STANDARD

panasonic.net/id/pidsx/global CCD The sensor can be used for various applications with its binary data output with four different sensing modes.

XL-80 spares list. Application note. Overview

OPTALIGN smart RS5 The power of precision shaft alignment

OPTALIGN smart RS5 The power of precision shaft alignment

Marsurf Marsurf ud 120 / Marsurf Ld 120. combined contour and roughness measurements

Exclusive Calibration System

Methods and Instrumentation for the measurement of Machine Tools (according to ISO 230 and ISO 1101)

RDS. Articulating Probe Holder.

Protect by Leica Geosystems A Lifetime Guarantee

Thread Mountable Cameo Laser Diode Module

PureGain PG1600P. Data Sheet. Fixed Gain, Compact EDFA with Digital Control Electronics. Contents: Features:

Leica TS11 Quick Guide. Version 2.0 English

INSPECTION OF THE TURBINE BLADES USING SCANNING TECHNIQUES

PRODUCT INFORMATION Model 1000XP Wide Range Particle Spectrometer (WPS )

New Sony DepthSense TM ToF Technology

Rotary Position Technology Incremental Encoders

A NEW LASER FOCUS ON PATIENT SAFETY

Infrared thermometers with visible laser for measuring surface temperature without contact

LaserLyte-Flex Red & Green Alignment System

Single-Axis Lasers for Flatness and Leveling Applications. Laser Systems for Flatness and Leveling L-730/L-740 Series

Industrial 2D LASER SCANNER LMS-Q120ii

VECTRA-TOUCH

Superfast Optical Roughness Measurement

Transcription:

www.leica-geosystems.com/metrology PCMM System Specifications Leica Absolute Tracker and Leica T-Products

Leica Absolute Tracker accuracy The measurement uncertainty of a coordinate U xyz is defined as the deviation between a measured coordinate and the nominal coordinate of that point. This measurement uncertainty is specified as a function of the distance between the laser tracker and the measured point. The accuracy specified below is achieved with Leica Geosystems precision reflectors and a measurement mode of 1 second per point under stable environmental conditions, with a maximum distance of 40 radial meters from the measurement sensor. All specifications are stated in maximum permissible error (MPE). U xyz, Full Range (Full Range Definition: 360 horizontally, ± 45 vertically) AT901-B, AT901-MR, AT901-LR ± 15 µm + 6 µm/m (±0.0006" + 0.00007"/ft) Feature Robust construction and superior thermal stability with homogenous internal design and low heat emitting tracker sensor head The AIFM or Absolute Interferometer combines the absolute measurement from the ADM with the almost instantaneous update rate of the interferometer to produce the most accurate, stable, technologically mature distancing unit we have ever created Benefit Continuous on-spec operation in tough industrial environments with no need for frequent compensation routines; a yearly calibration is all your Leica Absolute Tracker will ever need Waiting for the tracker to lockon is now a thing of the past. Simply catch the beam and you are measuring again without delay. No matter if you are using a reflector, Leica T-Probe, Leica T-Scan or Leica T-Mac, the AIFM can instantly re-establish a broken laser beam and immediately start measuring the moving target. U xyz, in 2.5 x 5 x 10 m volume (8.2 x 16.4 x 32.8 ft) (Prerequisite: The laser tracker sensor is anywhere inside the volume) AT901-B, AT901-MR, AT901-LR ± 10 µm + 5 µm/m (±0.0004" + 0.00006"/ft) 2.5 m (8.2 ft) 10 m (32.8 ft) 5 m (16.4 ft) 6 Degrees of Freedom (6DOF) Portable CMM available as an option Lean construction and compact dimensions, weighing 22 kg and 620 mm in length ADM/IFM with small beam diameter The world s only technologically mature PCMM system that can probe like a fixed CMM, scan like a laser scanner and track automated applications all in one system Easy one-person transportation and installation, in full compliance with labor department regulations; whole system fits in an average-sized station wagon Use of 0.5" reflectors over full measurement range Leica Laser Tracker, Leica T-Cam and Leica T-Probe Versatile Mounting Mounts vertically and horizontally providing versatility in measurement volume. * ** Ambient conditions Working temperature Storage temperature Relative humidity Operational elevation Storage elevation +0 C to +40 C (32 F to 104 F) -10 C to +60 C (14 F to 140 F) 10 90%, non-condensing 0 3,050 m (0 10,000 ft) 0 21,000 m (0 70,000 ft) * Typical results within specifications. ** Can not be used with the T-Cam in the horizontal position. Marks of conformity CB-certified by electrosuisse CE Yes Yes Yes

Leica Laser Tracker AT 901-B AT 901-MR AT 901-LR Accuracy shown is the maximum permissible error (MPE). Compatibility Compatible with Leica T-Cam No T-Cam MR T-Cam LR Compatible with Leica T-Probe No Yes Yes Compatible with Leica T-Scan No Yes Yes Compatible with Leica T-Mac No Yes Yes Measurement Volume Typical Volume (Ø) 160 m (525 ft) 50m (164 ft) 160 m (525 ft) Horizontal 360 360 360 Vertical ± 45 /360 * ± 45 /360 * ± 45 /360 * *in horizontal setup AT 901-B, AT 901-LR Measuring and tracking performance Measuring rate Measuring rate output Tracking speed lateral Tracking speed radial Acceleration lateral Acceleration radial 3,000 points per second 1,000 points per second > 4 m/s (13 ft/s) > 6 m/s (19 ft/s) > 2 g unlimited Absolute Interferometer (AIFM) Yes Yes Yes Principle technology Single Beam Heterodyne Interferometer with Polarization Modulation Absolute Reference Wavelength 633 nm / 795 nm (visible / IR) Warm-up time, cold start 8 min Warm-up time, warm start 5 min Largest Beam diameter 4 mm Interferometer Distance Resolution 0.32 µm (0.000013 ) Interferometer Distance Accuracy ± 0.5 µm/m (± 0.000006 /ft) Dynamic Lock-On Accuracy ± 10 µm (± 0.00039 ) Typical Lock-On working range 1.0 80.0 m 1.0 9.0 m 1.0 80.0 m (3.3 262 ft) (3.3 29 ft) (3.3 262 ft) AT 901-MR Laser Safety IEC 60825-1; Second Edition (2007-03) The Laser Tracking System is a Class 2 Laser Product Accuracy information Angular resolution Angular repeatability, full range and in 2.5 x 5 x 10 m volume Angle accuracy, full range Angle accuracy in 2.5 x 5 x 10 m volume AT 901-B, AT 901-MR & AT 901-LR 0.14 arc sec ± 7.5 µm + 3 µm/m (±0.0003" + 0.00004"/ft) ± 15 µm + 6 µm/m (±0.0006" + 0.00007"/ft) ± 10 µm + 5 µm/m (±0.0004" + 0.00006"/ft) Size and weight Sensor size 620 / 290 / 240 mm (24 / 11 / 9 ) Sensor weight 22 kg (48.5 lbs) Controller size 510 / 485 / 200 mm (20 / 19 / 7.9 ) Controller weight 17 kg (37.5 lbs)

Leica T-Probe system accuracy The measurement uncertainty of 3D points U3d is defined as the distance between a measured point and the nominal position of that point. This measurement uncertainty is specified as a function of the distance between the laser tracker and the measured point. The measurement uncertainty of spatial length U l is defined as the deviation between a measured length and its nominal value. This measurement uncertainty is specified as a function of the shortest distance between the laser tracker and the measured length. The length can be up to 6m and is positioned perpendicularly to the laser beam (Leica T-Probe held in constant orientation). Comfort through true intelligence Feature Armless operations Wireless operations No direct line of sight between probe tip and laser tracker required Benefit Full Walk-Around freedom Speed and safety increase Reaches hidden, recessed or hard-to-reach parts without needing to reposition laser tracker Measurement uncertainty of sphere radius U r is defined as the deviation between a measured sphere radius and its nominal value. This specification assumes a reference sphere with a radius bet ween 10 mm and 50 mm. This measurement uncertainty is specified as a function of the distance between the Laser Tracker and the measured sphere (Leica T-Probe held in constant orientation). The uncertainty specified below is achieved with Leica T-Probe (110 mm stylus in mount 1/2) and a measurement mode of 1s per point under stable environmental conditions. Accuracy shown is the maximum permissible error (MPE). Typical results are half the MPE. Measurement uncertainty of 3D Point (MPE) U3d = 100 µm if under 7 m (0.004" if under 23 ft) U3d = 30 µm + 10 µm/m if greater than 7 m (0.0012" + 0.00012"/ft if greater than 23 ft) Measurement uncertainty of spatial length (MPE) U l = ± 60 µm if under 8.5 m (± 0.0024" if under 27.9 ft) U l = ± 7 µm/m if greater than 8.5 m (± 0.00008"/ft if greater than 27.9 ft) Probe self-identification Stylus self-identification Acoustic system feedback in your hand Visual system feedback in your hand Precision quick release for stylus Wide variation of styli type and length 6DOF Dynamic Lock-On Eliminates handling errors Eliminates handling errors Accelerates measurement process Accelerates measurement process Flexibility with speed Highest probing flexibility No more waiting for the tracker to lock on - AIFM can instantly re-establish a broken laser beam Measurement uncertainty of sphere radius (MPE) U r = ± 20 µm + 2 µm/m (± 0.0008" + 0.00002"/ft) Leica T-Probe AT 901-MR AT 901-LR Accuracy shown is the maximum permissible error (MPE). Measurement volume Maximal volume (Ø) 18 m (59 ft) 30 m (98 ft) Horizontal 360 Vertical ± 45 Acceptance angle (Freedom to rotate) Pitch angle ± 45 jaw angle ± 45 Roll angle 360, unlimited Measuring and tracking performance Measuring rate output Tracking speed all directions Acceleration, all directions 1,000 points per second > 1 m/s ( 3.3 ft/s) 1 g Weight Leica T-Probe with standard tip and battery Leica T-Probe with standard tip and without battery Leica T-Cam MR and LR 670 g ( 1.48 lb) 570 g ( 1.26 lb) 4.7 kg ( 10.36 lb)

Comfort through true intelligence Leica AT901-MR gives you a measurement volume of up to 18 m (59 ft), Leica AT901-LR up to 30 m (98 ft) Feature Sealed housing Benefit Work in toughest industrial environments Leica T-Mac system accuracy Accuracy of rotation angles 0.01 = 18 µm/100mm (0.002"/ft) Accuray of time stamp < 5 µs Positioning accuracy for typical robotic drilling applications 50 µm (0.002") Positional accuracy ± 15 µm + 6 µm/m (±0.0006" + 0.00007"/ft) Accuracy shown is the maximum permissible error (MPE). Robust design, with no internal moving parts or mechanisms Simple mechanical interface Adaptation of tool exchange interface Multiple reflector nests on Leica T-Mac housing 6DOF Dynamic Lock-On Designed for use in real production environments, easy to service and with no wear and tear Direct mounting on a robot or a machine Automatic connection to robot with high repeatability of under 3 µm (0.00012") Calibrated reflector locations as known home points for easy establishing of object orientation No more waiting for the tracker to lock on - AIFM can instantly re-establish a broken laser beam Leica T-Mac AT 901-MR AT 901-LR Accuracy shown is the maximum permissible error (MPE). Measurement volume Maximal volume 18 m 30 m (59 ft) (98 ft) Horizontal 360 Vertical ± 45 Acceptance angle (Freedom to rotate) Pitch angle ± 45 Jaw angle ± 45 Roll angle 360, unlimited Measuring and tracking performance Measuring rate output Tracking speed all directions Acceleration all directions 1,000 points per second > 1 m/s ( 3.3 ft/s) 1 g Accuracy Accuracy of rotation angles 0.01 = 18 µm/100mm (0.002"/ft) Accuray of time stamp < 5 µs Positional accuracy ± 15 µm + 6 µm/m (±0.0006" + 0.00007"/ft) Weight Leica T-Mac 1,480 g ( 3.26 lb)

Leica T-Scan system accuracy Measurement uncertainty of spatial length U l is the deviation between a measured length and its nominal value. This measurement uncertainty is specified as a function of the shortest distance between the Laser Tracker and the measured length. The length can be up to 6 m and is perpendicular positioned to the laser beam. The centers of two fix-mounted spheres (sphere radius between 15 mm and 20 mm) at the end of the reference length are representing the nominal distance. The measured distance between the sphere centers is calculated using scan data of all four Leica T-Scan sides. Measurement uncertainty of sphere radius U R is the deviation between a measured sphere radius and its nominal value. The measurement uncertainty of the sphere surface Us is defined as the value of all deviation from the best-fit sphere that is calculated with all measured points. This specification assumes a reference sphere with a radius between 10 mm and 50 mm. These measurement uncertainties are specified as a function of the distance between the Laser Tracker and the sphere. Data of all four Leica T-Scan sides is utilized for the calculation of the sphere radius and the sphere surface. Measurement uncertainty of plane surface U p is defined as the value of all deviation from the best-fit plane that is calculated with all measured points. Data from all four Leica T-Scan sides is utilized for the calculation of the plane surface. The uncertainty specified below is achieved with Leica T-Scan using a point density setting of at least 0.35 mm and a line spacing of at least 0.35 mm under stable environmental conditions. Measurement uncertainty of spatial length (2 sigma) U L = ± 60 um if under 8.5 m (± 0.0024 if under 27.9 ft) U L = ± 60 um + 4 um/m if greater than 8.5 m (± 0.0024 + 0.00005 / ft if greater than 27.9 ft) Measurement uncertainty of sphere radius (2 sigma) U R = ± 50 um if under 8.5 m (± 0.002 if under 27.9 ft) U R = ± 50 um + 4 um/m if greater than 8.5 m (± 0.002 + 0.00005 / ft if greater than 27.9 ft) U S = ± 85 um + 1.5 um/m (±0.0033 + 0.00002 /ft) Measurement uncertainty of plane surface (2 sigma) U P = ± 80 um + 3 um/m (±0.0031 + 0.00004 /ft) Leica AT901-MR gives you a measurement volume of up to 18 m (59 ft), Leica AT901-LR up to 30 m (98 ft)

Leica T-Scan AT 901-MR AT 901-LR Measurement volume Maximal volume (Ø) 18 m 30 m (59 ft) (98 ft) Horizontal 360 Vertical ± 45 Acceptance angle (Freedom to rotate) Pitch angle ± 45 Jaw angle ± 45 Roll angle 360, unlimited Measuring and tracking performance Tracking speed all directions Acceleration all directions > 1 m/s ( 3.3 ft/s) 1g Leica T-Scan sensor Measuring depth 78 mm (3.07 ) Mean scan width 90 mm (3.54 ) Mean measuring distance 86 mm (3.39 ) Line frequency up to 140 lines/second Measurement sampling rate 20,000 points per second Point density 0.07 mm 0.98 mm (0.0028 0.039 ) Accuracy ±20 µm (0.00079 ) Laser Safety IEC 60825-1; 1993+A1 1997 + A2: 2001, class 2 Working temperature Storage temperature Relative humidity Weight Leica T-Scan +16 C to +24 C (61 F to 75 F) -10 C to +60 C (14 F to 140 F) 10 90% non-condensing 1,200 g ( 2.6 lbs) Feature Benefit Measurement volume of up to 30 m (98 ft) Optimized laser optics Measure large object without repositioning laser tracker Better data quality: Higher performance on dark or shiny surfaces. Up to 20% less noise than before. More materials can be scanned without spray. Doubled data rate Time savings: Scan large surfaces in half the time compared to the previous Leica T-Scan generation. Minimal point distance cut in half Increased accuracy: Sheet metal features and contours can be digitised more precisely. Enhanced operator feedback with new intuitive LED pattern Improved ergonomics with optimized handle design and reduced weight Accurate information about optimal scanning distance Leica T-Scan is the most comfortable-to-work-with hand-held laser scanner in the industry 6DOF Dynamic Lock-On No more waiting for the tracker to lock on AIFM can instantly re-establish a broken laser beam.

Whether building the fastest car, the biggest plane, or the most precise tooling, you need exact measurements to improve quality and productivity. So when it has to be right, professionals trust Leica Geosystems Metrology to help collect, analyze, and present 3-dimensional (3D) data for industrial measurement. Leica Geosystems Metrology is best known for its broad array of control and industrial measurement products including laser trackers, Local Positioning Technology (LPT) based systems, hand-held scanners, 3D software and high-precision total stations. Those who use Leica Metrology products every day trust them for their dependability, the value they deliver, and the world-class service & support that s second to none. Precision, reliability and service from Leica Geosystems Metrology. Leica Geosystems Hexagon Metrology, Inc. 2473 Belvo Rd. Miamisburg, OH 45342 Toll Free: 800.329.4204 Phone: 937.353.1218 Fax: 937.247.0426 www.leica-geosystems.com/metrology www.portablecmm.us 764569 2008 Hexagon Metrology. Due to continuing product development, Hexagon Metrology reserves the right to change product specifications without prior notice. Printed in Switzerland. December 2008.