RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

Similar documents
Stand-alone Proximity Access Control

-DTZ001- Stand-Alone Proximity Access Control. User Manual

RBR-SB-KTZ001 LAR 2. User Manual

VIDI-AC-2CS Access Controller/ Reader

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

DOLXFD1000B. Waterproof Access Control/Reader

Waterproof. Keypad/Reader/Controller

W3-H Waterproof Keypad/Reader/Controller

Single Door Standalone Access Control User Manual

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Fingerprint Access Control F1. User Manual

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

CM-110SK Standalone Keypad Installation Instructions

W3-M. Metal waterproof standalone access control/reader. User Manual

VIS-3200 / VIS-3201 User Manual

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

User Manual. Split access control with intelligent secured power supply.

BC Digital Keypad. User Manual

User Manual. PCKeypad Wireless Keypad

Digital Keypad Introduction

CC Series metal access control Manual

EL-ST100 KEYPAD CONTROLLER

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

Installation and User Manual

HSY-S209 EM Metal waterproof access control system User Manual

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

DG-800 Stand-Alone Proximity Reader Instruction Manual

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

ACCESS CONTROL SYSTEM

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

Specifications: Features:

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

Metal Standalone Keypad Access Control S100

REX F-0-9 Standalone or Access Controller

CM-500 SK 500 USER CODES KEYPAD

CV-945 Stand-Alone Biometric Reader. Installation Instructions

GV-AS Controller. Installation Guide

9212i INSTALLATION. Stand-Alone Keypad. Instructions

FTK5 PROXIMITY KEYPAD

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

6222 Two Door Module Technical Operations Manual

Fingerprint Identification Proximity Reader. Quick Installation Guide

Installing Keypad and Backplate

GV-Card Reader. User s Manual

GV-AS/EV Controller. User s Manual

Revision Date: 02 Mar 2018

PR602LCD v1.0 Installer Manual Rev. A

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

2000 Series e/em Style Keypad Installation and Programming Manual

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

Wireless Key fob, Key pad & Receiver Range

PXL-250 Tiger Controller

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

1. Product Specification

Two Door Controller GEN-045

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

UC-2000 Installation Manual Unicorn Computers Technology Limited

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

CP150B Vandal & Weather Resistant Keypad Security Systems

SP1 MP1 WP2 WP1. 125kHz reader models with the following prefixes: 13.56MHz reader models with the following prefixes:

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

DG Series. Access Control Proximity Readers DG-160 DG-800

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

AS Keypad User Manual

GV-AS/EV Controller. User s Manual

KP2000E/EM Series Style Keypad

Stand-Alone Data Chip System

Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader

ACTsmart2 Product Range Operating and Installation Instructions

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details

_ Access control SISTEMAS DE SEGURIDAD

GV-RK1352 and GV-R1352 Card Reader

WRI400 WIRELESS READER INTERFACE

Zodiac FR100 TM INSTALLATION MANUAL

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

INSTALLATION INSTRUCTIONS 923P EntryCheck TM

GV-EL124S Electric Strike

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

Outdoor Stand-Alone Weatherproof Keypads

B100-SA Standalone Biometric Reader

Connecting a Cisco Reader Module

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

Suprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

Access control panel U-Prox IC E (Elevator control)

S125 Multi-Purpose 125 KHz RFID Reader USER MANUAL. 9V/24V DC Operating Voltage, AC (optional) KHz RFID EM4100/2 Cards & Tags

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you

Transcription:

RD-SR2 Proximity Card Reader with Remote Control User Manual

INTRODUCTION The RD-SR2 is a compact, weather resistant multi-function card reader that can be used as a standalone programmable access control card reader as well as a Wiegand output card reader providing proximity entry for up to 1000 users, (998 common users and 2 panic users) PIN access is also possible via the remote control unit for the Administrator and all user data can be transferred from one unit to another within 3 minutes (Maximum connection is 10 units) It reads both EM & HID card or key fob. It uses Atmel micro controller to ensure maximum performance in any environment, and the low-power circuit makes its service life prolonged The SR2 s unique feature is simple in design, easy to operate/program, and high reliability Features Weather resistant to IP66 Reads 125KHz EM & HID card or key fob One programmable relay operation Pulse mode, Latch mode relay operation Remote infrared programmer Master Add/Master Delete cards 1000 users (998 common users & 2 panic users) User data can be transferred from one unit to another Wiegand 26-37 bit input & output Card block enrolment Tri-colour LED status display Built in light dependent resistor (LDR) for anti tamper Buzzer for audible or silent mode Low temperature resistance(-40 ) Specifications: User Capacity Card/key fob Operating Voltage Idle Current Proximity Card Reader Radio Technology Read Range Wiring Connections Relay Adjustable Relay Output Time Lock Output Load Environment Operating Temperature Operating Humidity Physical Colour Dimensions Unit Weight Shipping Weight 1000 EM card and HID card 12~24V AC/DC <40mA EM&HID 125KHz Proximity Card 2-6cm Relay Output, Exit Button One (NO, NC, Common) 1-99 Seconds (5 seconds default) 2 Amp Maximum Meets IP66-40 ~60 20%RH-98%RH ABS Shell Black H: 102 W: 48 D:20mm 150g 250g

Package Contents SR2 Card Reader Infrared Remote Control Manager Cards Diode IN4004 (For relay circuit protection) Self Tapping Screws: 3*25mm Wall Anchors Screw Driver

INSTALLATION Remove the back cover from the unit Drill 2 holes(a,c) on the wall for the screws and one hole for the cable Knock the supplied rubber bungs to the screw holes(a,c) Fix the back cover firmly on the wall with 4 flat head screws Thread the cable through the cable hole(b) Attach the unit to the back cover Wiring cable Wire Insulation Colour Function Notes Red Power + (AC1) 12-24 Volts AC/DC Power input Black GND Ground Pink AC2 12-24 Volts AC power input Blue NO Normally open relay output Purple COM Common connection for relay output Orange NC Normally closed relay output Yellow OPEN Request to exit input (REX) Green Data 0 Wiegand output Data 0 White Data 1 Wiegand output Data 1 Grey Alarm output Negative output for alarm Brown Contact input Door/gate input (Normally closed)

Connection Diagram Examples Common power supply for magnetic lock (Fail open power to lock) Common power supply for lock release (Fail secure power to unlock) Common power supply for auto gate controller (using Normally Open contact) Attention: Install a 1N4004 or equivalent diode across the locking device when using a common power supply to prevent any back E.M.F as the reader might damage. (1N4004 is included in the packing)

Connection to standard Wiegand controller or PC access control system Set Operation Mode Stand-alone or Wiegand (Default is stand-alone) 2. Stand-alone Operation 3. Wiegand Reader Operation 4. Exit Program Mode * 72 # is factory default for stand-alone 73 # User data transfer connection (1 x power supply and 9 x SR2 units) Set User Data Transfer 2. Set Transfer Data on the first SR2 96 # For all 1000 users, this will take 3 minutes Within 3 minutes the green LED will shine, after 1 x bleep the LED will turn red to confirm data transfer

PROGRAMMING Programming will vary depending on access confirguration. Follow the instructions according to your access configuration General Programming Information Two ways Remote Control: Please use the Infrared Remote Control to program the Reader. The infrared receiver head is near the LED, so when you program the reader, please direct the Remote Control to the LED User ID number: Assign a user ID to the access card in order to track it. The user ID number can be any number from 0-997. IMPTANT: User IDs do not have to be proceeded with any leading zeros Recording of User ID is crucial. Modifications to the user require the User ID to be available Proximity Card: Any 125KHz industry standard 26 bit EM and HID Proximity card or key fob Sound and Light indications Operation Status Led Colour Buzzer Stand by Red light bright - Enter into programming mode Red light shines One bleep In the programming mode Orange light bright One bleep Operation error - Three bleeps Exit from the programming mode Red light bright One bleep Open lock Green light bright One bleep Alarm ** Red light Shines quickly Bleeps ** Please see Reset Procedure for ALARM Enter and Exit Program Mode Via the Remote Control 2. Exit Program Mode * Factory default is 123456 Set New Master Code Via the Remote Control 2. Enter New Master Code 0(New Master Code)#(Repeat New Master Code)# Set Operation Mode Stand-alone or Wiegand (Default is stand-alone) 2. Stand-alone Operation 72 # is factory default for stand-alone 3. Wiegand Reader Operation 73 # 4. Exit Program Mode *

Set User Data Transfer Via the Remote Control 2. Set Transfer Data on the first SR2 96 # For all 1000 users, this will take 3 minutes Within 3 minutes the green LED will shine, after 1 x bleep the LED will turn red to confirm data transfer Add User Cards Via the Remote Control 2. Add Card: Using Auto ID number (Allows the SR2 to assign Card to next available User ID number) 3. Add Card: Select Specific ID number (Allows manager to define a specific User ID to associate the card to) 4. Add Card: by Card Number 5. Add Card: Block Enrolment (Allows the master card to add up to 998 cards in a single step this takes 2 minutes) 6. Exit Program Mode * 1 (Present Card) # Repeat Step 2 for additional user cards 1 (User ID) # (Present Card) # The user ID is any number from 0-997 1 (Input the 8/10 digit Card number) # 1 (User ID) # (Card Quantity) # (The first card number) # Card or fob number MUST be consecutive Add PIN User For Administrator for Remote Control 2. Add PIN: Via remote controller 1 (Enter PIN number, 4-6 digits) # Delete User Cards Via the Remote Control 2. Delete Card: By read card 2 (Present Card) # Repeat Step 2 for additional user cards before pressing the # 3. Delete Card: Select Specific ID 2 (Enter user ID number) # The user ID is any number from 1-998 4. Delete Card: by Card Number 2 (Input the 8/10 digits Card number) #

Delete All Users Via the Remote Control 2. Delete All User Cards 2 (Master Code) # Set Relay Configuration Via the Remote Control The relay configuration sets the behaviour of the output relay on activation 2. Pulse Mode 3. Latch Mode 4. Exit Program Mode * 3 (1-99) # The relay time is 1-99 seconds. (1 is 50mS.) Default is 5 seconds 3 0 # Sets the relay to ON/OFF Latch mode Set Strike-out Alarm Via the Remote Control The strike-out alarm will engage after 10 failed card attempts. Default setting is OFF. The strike-out alarm can be set to deny access for 10 minutes after engaging or it can be set to disengage only after presenting a valid user card or Master code 2. Strike-Out OFF 3. Strike-Out ON 4. Strike-Out ON (Alarm) Set alarm time 5. Exit Program Mode * 6 0 # (factory default) 6 1 # Access will be denied for 10 minutes 6 2 # 5 (0-30) # factory default is 1 minute Enter Master code # or valid user card to silence Set Audible and Visual Response Via the Remote Control 2. Control LED OFF = 70 # ON = 71 # 3. Control Sounds 4. Exit Program Mode * OFF = 74 # ON = 75 # (Factory defaults are ON)

Set Card Reading Type Via the Remote Control 2. Read EM & HID card 93 # (factory default) 3. Read EM card only 94 # 4. Read HID card only 5. Exit Program Mode * 95 # Add cards by Master Add Card Action 1. Present the Master Add Card Present the user card/s to be added Present the Master Add Card to confirm Delete cards by Master Delete Card Action 1. Present the Master Delete Card Present the user card/s to be deleted Present the Master Delete Card to confirm Reset Procedure Reset Alarm: The alarm will sound for 3 minutes. To reset, present a valid user card or enter via the remote control Reset to Factory Default: To reset to factory default, power off, press the Exit Button or short circuit the Black (GND) and Yellow (Open) wires, and then power on, there will be two bleeps, and the LED light will turn orange, keep this condition until you hear a long bleep after 10 seconds. The LED will turn red to confirm factory default is successful Reset to Factory Default to add new Mater Cards: To reset to factory default, power off, press the Exit Button, or short circuit the Black (GND) and Yellow (Open) wires, and then power on, there will be two bleeps, and the LED light will turn orange Present any two 125KHz EM cards or key fobs and the LED will turn red to confirm factory default is successful, Release the exit button or the Black (GND) and Yellow (Open) wires, The first card presented will be the Master Add Card, and the second card will be the Master Delete Card Note: Reset to factory default, the user s card/key fob information is still retained