CDM-570/L & CDM-570/L-IP Satellite Modems

Similar documents
CDM-570A/L & CDM-570A/L-IP Satellite Modems

CDM-570A/L-IPEN Satellite Modems

CDM-570A/L & CDM-570A/L-IP Satellite Modems

CDM-570A/L-IPEN Satellite Modems

CDM-570A/L & CDM-570A/L-IP Satellite Modems

CDM-570A/L-IPEN Satellite Modems

SLM-5650A Satellite Modem

CDM-625-EN Advanced Satellite Modem with DoubleTalk Carrier-in-Carrier. Modems

CDM-625-EN Advanced Satellite Modem

Modems. CDM-625 Advanced Satellite Modem with DoubleTalk Carrier-in-Carrier

CDM-625A-EN Advanced Satellite Modem

CDM-625 Advanced Satellite Modem

SLM-5650A Satellite Modem

SLM-5650A Satellite Modem

CDM-425 Advanced Satellite Modem

SLM A Satellite Modem. Modems

CDM-625A Advanced Satellite Modem

CDM-625A Advanced Satellite Modem

CDMER-625A Advanced Satellite Modem

UHP - UNIVERSAL VSAT PLATFORM PRODUCT OVERVIEW

Quantum Series PD155i

Q-Flex. Dual IF/L-Band Satellite Modem

SATCOM SCPC Extreme Modem

CDM-570/570L. Vipersat. Satellite Network Modem Router User Guide. MN/22125 Revision 1

Vipersat CDM-570/570L. Satellite Network Modem Router. User Guide. Part Number MN/22125 Revision 0

CDM-760 Advanced High-Speed Trunking Modem

EVOLUTION Series. PD10 IF Satellite Modem

Advanced SCPC Satellite Modem. 70/140MHz or L-band, 220V AC, IP, E1, T1, Data

Simple Satellite Network Solutions. Radyne SkyWire Company Proprietary -- 1

QUANTUM Series PD60L L-band Satellite Modem

328 Innovation Blvd. 2&3 The Matchyns, Witham

CDM-760 Advanced High-Speed Trunking and Broadcast Modem

Q-MultiFlex Hub-in-a-Box IP Modulator / Multi-demodulator

328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End. Tel: 1 (814) Tel: +44(0)

CDM-760 Advanced High-Speed Trunking and Broadcast Modem

Q-MultiFlex. Point-to-multipoint IP Modulator / Multi-demodulator

QUANTUM Series PD20L L-band Satellite Modem

Q-MultiFlex. Hub-in-a-Box IP Modulator / Multi-demodulator

Saving Bandwidth made Easy and Affordable DATUM SYSTEMS M7 Modular Series Introduction June 2015

Advanced VSAT Solutions. Copyright 2010 Comtech EF Data Corporation

Vipersat CDD-56X Series Satellite Network Demodulator Router

328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End. Tel: 1 (814) Tel: +44(0)

Network Solutions made Easy and Affordable DATUM SYSTEMS. M7 Modular Series Introduction. May 2016

SM Cirius LM 175/200+ Mbps Ethernet + 16 T1/E1

Benefits of Turbo Product Code FEC include:

Telecom Point to Point Radio

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

Q-Flex. Dual IF/L-Band Satellite Modem

Q-Flex. Dual IF/L-Band Satellite Modem

BPSK 5/16 BPSK 21/44 QPSK 3/4 OQPSK 3/4 (requires OQPSK optioned modem) QPSK 1/2 OQPSK 1/2 (requires OQPSK optioned modem)

Advanced VSAT to Heights Networking Platform Network Conversion Overview

Q-FlexE Dual IF/L-Band Satellite Modem With IP Encryption

CDM-570/570L. Part Number MN/CDM570L.IOM Revision 4

see the Cisco SPA100 Series Administration Guide for details. The configuration profile is uploaded to the Cisco SPA122 at the time of provisioning.

IPmux-1E. TDMoIP Gateway FEATURES

Giga Lynx DATASHEET. DS-1029-F 1 of 5

Giga Orion DATASHEET. DS-1025-E 1 of 5

Apex Orion DATASHEET. DS-1026-E 1 of 5

Implementing A STAR Network Using Comtech EF Data's IP-Enabled Satellite Modems

Casa Systems C10G CMTS

328 Innovation Blvd. 1 Wheaton Road, Witham

FCD-155. STM-1/OC-3 Terminal Multiplexer FEATURES

Q-Lite Comms-On-The-Move Satellite Modem Card

FD404GW series 4GE+ 2POTS + CATV+ Wi-Fi Single Fiber EPON ONU Brief Views ONU FD404GW (4GE+2POTS+RF+Wi-Fi) series is a FTTH bandwidth access equipment

Trio Q. Licensed UHF Ethernet and Serial data radio. QR450 Half Duplex

Features and Benefits

QFlex-400. Dual IF/L-Band Satellite Modem

Premium Services Using Vipersat Dynamic SCPC (dscpc) With Guaranteed Bandwidth

A more intelligent way to implement VoIP in remote offices and SOHO environments

PTP 810i ALL-INDOOR SOLUTIONS

CONVERGENCE 32XX Series PDH / Ethernet Convergent System

Wireless Cable Modem. User's Manual

328 Innovation Blvd. 1 Wheaton Road, Witham

Apex Lynx DATASHEET. DS-1030-E 1 of 5

Q-Flex Dual IF/L-Band Satellite Modem

idirect Broadband Router Hub Solutions

ISCOM HT803G-U GPON home terminal

Gmux Modular TDMoIP Gateway FEATURES

CDD-562L/564. Part Number MN/CDD564L.IOM Revision 2

Cisco SRW208 8-Port 10/100 Ethernet Switch: WebView Cisco Small Business Managed Switches

Q-Lite Comms-On-The-Move Satellite Modem Card

IPmux-14. TDMoIP Gateway FEATURES DESCRIPTION

Q-FlexV Dual IF/L-Band Broadcast Satellite Modulator/Modem

EnGenius EAP-9550 Indoor Access Point

ECB N Multi-Function Gigabit Client Bridge

CDD-562AL/564A/L. Multi-Channel Demodulator Installation and Operation Manual 70/140 MHz Satellite Quad Demodulator L-Band Satellite Dual Demodulator

ECB N Multi-Function Client Bridge

VCL-TP, Teleprotection Equipment

znid - Zhone's Intelligent NID

Redline AN80i Point-to-Point System Terminal (AN-80i)

SOLO NETWORK (11) (21) (31) (41) (48) (51) (61)

Q-FlexV. Dual IF/L-Band Broadcast Satellite Modulator/Modem

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO

Cisco SRW Port Gigabit Switch: WebView Cisco Small Business Managed Switches

CHIRON-4E1. E1 over Ethernet Multiplexer (TDM over IP)

Eight-Channel DVB-C Direct VHF/UHF QAM A/C Modulator

Optimux-1553 STM-1/OC-3 Terminal Multiplexer

MA5400 IP Video Gateway. Introduction. Summary of Features

Optimux-34, Optimux-25

DAS Series. DIGITAL FIBER DAS SYSTEM MHz. Product Features. Applications

Transcription:

CDM-570/L & CDM-570/L-IP Satellite Modems Satellite Modems Overview The CDM-570 and the CDM-570L are Comtech EF Data s entry-level satellite modems that provide industry leading performance and flexibility in a 1 RU package at a very competitive price. Designed to address the market for low-cost terminals, the modems are available with 70/140 MHz or L-Band IF and EIA-530/-422, V.35, EIA-232 and G.703 data interfaces. An optional Internet Protocol (IP) Module with 10/100Base-T Ethernet port is available for IPcentric applications. Features Data rate range from 2.4 kbps to 9.98 Mbps CDM-570 & CDM-570-IP: 50 to 90 or 100 to 180 MHz IF range CDM-570L & CDM-570L-IP: 950 to 2000 MHz IF range Modulation types: BPSK, QPSK, OQPSK, 8PSK, Patented 8-QAM, 16-QAM Forward Error Correction (FEC) choices include Turbo Product Code (TPC), Viterbi, Reed-Solomon, and Trellis Coded Modulation (TCM) Data Interfaces: EIA-422/530, V.35, G.703 T1/E1 (option), 10/100Base-T Ethernet (option) Standards based management via SNMP, Web, or Telnet Typical Users Enterprise Internet Service Providers Satellite Service Providers Offshore & Maritime Mobile Operators Common Applications Mobile Backhaul Communications on-the-move Disaster Recovery & Emergency Communications Enterprise Offshore & Maritime Communications Satellite News Gathering Support for mesh, star and hybrid network topologies G.703 clock extension for IP backhaul (option) Fast acquisition demodulator (± 32 khz acquisition range, 64 kbps, Rate 1/2 QPSK: 150 ms average) Automatic Uplink Power Control (AUPC) Embedded Distant-end Monitor and Control (EDMAC/EDMAC2) Redundancy options CDM-570 & CDM-570-IP: FSK communications to CSAT-5060 or KST-2000A CDM-570L & CDM-570L-IP: 10 MHz reference for BUC, FSK communications and optional BUC power supply CDM-570L & CDM-570L-IP: 10 MHz reference and power supply for LNB Optional, integrated IP Module with 10/100Base-T Ethernet port (CDM-570-IP and CDM-570L-IP) Static IP routing for unicast and multicast Header and payload compression for maximum efficiency IGMP v1 and v2 VLAN capability with 802.1Q compliant QoS Vipersat Management System (VMS) integration Turbo Product Coding The optional Turbo Product Codec delivers significant performance improvement when compared to Viterbi with concatenated Reed- Solomon. It offers increased coding gain, lower decoding delay, and significant bandwidth savings compared to traditional FEC. EDMAC & AUPC Operation The CDM-570/L-IP has the ability to monitor and control the distant end of a point-to-point satellite link using EDMAC or EDMAC2. User data is framed and bits are added to pass control, status, and AUPC information. This is transparent to the user. Management The modems support SNMP, web-based and command line interfaces for management. The modems can also be configured and monitored from the front panel, or through the remote M&C port (for non-ip mode of operation). Ten complete RF configurations may be stored in the modem. An event log stores alarm and status information in non-volatile RAM, while the link statistics log stores link performance (Eb/No and AUPC performance) for monitoring and reporting purposes. www.comtechefdata.com

G.703 Clock Extension Mobile networks require precise synchronization of base stations, which is a challenge when using IP backhaul. Most operators are forced to use GPS-based external equipment for site synchronization. CDM-570/L-IP offers a G.703 clock extension option that propagates a high stability reference from hub to the remote. This process does not require additional bandwidth. Feature Enhancements The codes make it easy to upgrade the modem capability in the field. New features can be added on site, using access codes purchased from Comtech EF Data that can be entered via the front panel. IP Module With its innovative architecture and support for advanced capabilities, IP Module-equipped versions of the CDM-570/L allow for efficient IP networking and transport over satellite. The CDM-570/L-IP supports a wide range of applications and network topologies. Header Compression Option Configurable on a per route basis, header compression reduces the bandwidth required for VoIP by as much as 60%. Example: A G.729 voice codec, operating at 8 kbps, requires 32 kbps bandwidth once encapsulated into an IP/UDP/RTP frame. With compression, the same voice call needs only 10.8 kbps total WAN satellite bandwidth. Typical Web/HTTP traffic can also be reduced by 10% via IP/TCP header compression. Payload Compression Option Configurable on a per route basis, payload compression can reduce the required satellite bandwidth by up to 40%. Quality of Service (QoS) Option The modems support multi-level QoS to reduce jitter and latency for real time traffic, provides priority treatment to mission critical applications and allows non-critical traffic to use the remaining bandwidth. Supported modes are: DiffServ Industry-standard method of providing QoS enabling seamless co-existence in networks that implement DiffServ. Max/Priority Provides eight levels of traffic prioritization with the ability to limit maximum traffic per priority class Min/Max Provides a Committed Information Rate (CIR) to each user defined class of traffic with the ability to allow a higher burstable rate depending on availability Vipersat Management System Dynamic SCPC carrier allocation & true bandwidth-on-demand User-defined policies for upstream carrier switching Star and full mesh capabilities using single hop on-demand Advanced switching takes advantage of using other modulation/forward error correction combinations Guaranteed bandwidth capability VMS Network & Bandwidth Management A Vipersat-powered network integrates these advanced modems with a powerful network management tool, the Vipersat Management System (VMS). In addition to the traditional monitoring and control of the CDM-570/L-IP modems and the CDD-564/L and CDD-562L demodulators, the VMS allows these devices to share bandwidth, and when needed, switch automatically to a dedicated SCPC channel. In a Vipersat-powered network, the CDM-570/L-IP modem takes advantage of its fast acquisition demodulation to allow it to operate in a shared mode. Inbound transmissions (from remote to hub) can be switched from a shared Selective Time Division Multiple Access (STDMA) mode to a dedicated Single Carrier Per Channel (SCPC) connection via a variety of user defined policies or triggers. This enables the network to more effectively handle real-time connection-oriented applications and reduces both latency and network congestion. Through VMS, dynamic point-to-point mesh connections can also be established between remotes. Upstream Switching Through protocol classification in the remote terminals, the modem initiates automatic switching. VMS establishes dscpc bandwidth based on policies that can be individually enabled on a per-remote basis, or globally enabled. Policies can be configured for a variety of applications such as VoIP, video (VTC), or based on a load, or via a schedule, Type of Service (ToS), or QoS rules such as IP port or IP address and protocol type. Operators are able to set minimum and maximum data rates for each remote as well as excess data rates for an initial upstream switch. Vipersat Operation Mode Vipersat operation is enabled via a feature code. Networks can easily start off in point-to-point or point-to-multipoint configurations. As the network grows and users wish to take advantage of the bandwidth on-demand savings by implementing a Vipersat network, modems can easily be upgraded to Vipersat mode. Vipersat mode provides for the ability to operate in the following modulation/fec rates: STDMA QPSK, Rate 3/4 Turbo FEC all STDMA modes Data Rate Range: 64 kbps 4.5 Mbps BPSK, Rate 5/16 Turbo FEC Entry Channel Mode only Data Rate Range: 32 kbps to 937 kbps SCPC All Turbo Product Code FEC rates as detailed in the following specifications

Specifications Frequency Range Data Interfaces Data Rate Range (See user manual for details) Modulation & FEC CDM-570 & CDM-570-IP: 50 to 90 or 100 to 180 MHz, 100 Hz resolution CDM-570L & CDM-570L-IP: 950 to 2000 MHz, 100 Hz resolution EIA-422/-530 DCE, V.35 DCE, Sync EIA-232, 10/100Base-T Ethernet (option), G.703 T1 balanced (option), G.703 E1 balanced or unbalanced (option) 2.4 kbps to 9.98 Mbps (depending on modulation, FEC and framing), 1 bps step with fully independent TX and RX rates Data Rate Range 5/16 BPSK TPC 2.4 kbps to 0.937 Mbps 21/44 BPSK TPC 2.4 kbps to 1.430 Mbps 1/2 BPSK 2.4 kbps to 1.500 Mbps 1/2 QPSK/OQPSK 4.8 kbps to 3.000 Mbps 3/4 QPSK/OQPSK 7.2 kbps to 4.500 Mbps 7/8 QPSK/OQPSK 8.4 kbps to 5.250 Mbps 2/3 8PSK TCM 8.7 kbps to 4.400 Mbps 21/44 QPSK/OQPSK TPC 4.8 kbps to 2.860 Mbps 3/4 QPSK/OQPSK TPC 7.2 kbps to 4.500 Mbps 7/8 QPSK/OQPSK TPC 8.4 kbps to 5.250 Mbps 0.95 QPSK/OQPSK TPC 9.1 kbps to 5.666 Mbps 3/4 8PSK/8-QAM TPC 10.8 kbps to 6.750 Mbps 7/8 8PSK/8-QAM TPC 13.6 kbps to 7.875 Mbps 0.95 8PSK/8-QAM TPC 15.3 kbps to 8.500 Mbps 3/4 16-QAM TPC 14.4 kbps to 9.000 Mbps 7/8 16-QAM TPC 16.8 kbps to 9.980 Mbps Uncoded BPSK 4.8 kbps to 3.000 Mbps Uncoded QPSK/OQPSK 9.6 kbps to 5.000 Mbps Note: Data rate specifications reflect CDM-570/L or CDM-570/L-IP modem operating in non-vipersat mode Scrambling Mode dependent ITU V.35, or proprietary externally synchronized FEC Options Viterbi Rate 1/2 BPSK, QPSK/OQPSK Rate 3/4 and 7/8 QPSK/OQPSK and 16-QAM w/rs TCM 8PSK 2/3 (Closed network not IESS-310) Turbo Product Coding Rate 21/44 BPSK, 5/16 BPSK, Rate 21/44 QPSK/OQPSK Rate 3/4 and Rate 7/8 QPSK/OQPSK, 8PSK/8-QAM and 16-QAM Rate 0.95 QPSK/OQPSK and 8PSK/8-QAM Reed-Solomon Proprietary 220/200 and 200/180 modes available Uncoded BPSK, QPSK/OQPSK M&C Interface EIA-232, EIA-485 (2- or 4-wire), Ethernet 10/100Base-T (dependent on operational mode) Input/Output Impedance CDM-570 & CDM-570-IP: matched for 50/75 Ω, BNC connector CDM-570L & CDM-570L-IP: transmit and receive 50 Ω, female Type N connector External Reference Input 1, 2, 5, 10 or 20 MHz, BNC connector Form C Relays TX, RX traffic alarms and unit faults Modulator CDM-570 & CDM-570-IP CDM-570L & CDM-570L-IP Frequency Stability ±1 ppm, 0º to 50ºC (32º to 122ºF) ±0.06 ppm, 0º to 50ºC (32º to 122ºF) Output Power 0 to 25 dbm, 0.1 db steps 0 to 40 dbm, 0.1 db steps Accuracy ± 0.5 db over frequency and temperature ± 1.0 db over frequency and temperature Phase Noise < 0.75 degrees RMS double-sided, 100 Hz to 1 MHz < 1.2 degrees RMS double-sided, 100 Hz to 1 MHz Output Spectrum/ Meets IESS-308/-309 power spectral mask Filtering Harmonics and Spurious < -55 dbc/4 khz (typically < -60 dbc/4 khz) Transmit On/Off Ratio 55 db minimum External TX Carrier Off By TTL LOW signal, or RTS TX Clock Options Internal (SCT), external (TT), loop timing with symmetric or asymmetric operation (data interface dependent) Demodulator CDM-570 & CDM-570-IP CDM-570L & CDM-570L-IP Input Power Range -30 to -60 dbm -130 + 10 log symbol rate, dbm (minimum) -90 + 10 log symbol rate, dbm (maximum) Max Composite Level +35 dbc, up to -5 dbm absolute max. +40 dbc, up to -10 dbm absolute max. Acquisition Range Acquisition Time Receive Buffer Receive Clock Options Clock Tracking Monitor Functions ± 1 to ± 32 khz, 1 khz step ± 1 to ± 32 khz, 1 khz step, symbol rate <= 625 ksps ± 1 to ± 200 khz, 1 khz step, symbol rate > 625 ksps Highly dependent on data rate, FEC rate, and demodulator acquisition range. Example: 120 ms average at 64 kbps, Rate 1/2 QPSK, ± 10 khz acquisition sweep range, 6dB Eb/No 512, 1024, 2048, 4096, 8182, or 16384 bits Buffer disabled (RX satellite), buffer enabled (symmetric or asymmetric operation) (data interface dependent) ± 100 ppm minimum E b/n o, frequency offset, BER, buffer fill status, RX signal level Example BER Performance Viterbi BPSK, QPSK/OQPSK 1/2 3/4 7/8 10-5 5.4 (4.9) 6.8 (6.3) 7.7 (7.2) 10-7 6.7 (6.2) 8.2 (7.7) 9.0 (8.6) Viterbi & Concatenated Reed-Solomon 220/200 or 200/180 BPSK, QPSK/OQPSK 1/2 3/4 7/8 10-5 4.3 (4.0) 5.6 (4.7) 6.5 (6.0) 10-7 4.5 (4.2) 6.0 (5.2) 6.9 (6.5) Turbo Product Codec BPSK 5/16 21/44 10-6 2.4 (2.1) 2.8 (2.5) 10-7 2.6 (2.3) 3.1 (2.8) 10-8 2.7 (2.4) 3.3 (2.9) QPSK/OQPSK 21/44 3/4 7/8 0.95 10-6 2.9 (2.6) 3.8 (3.4) 4.3 (4.0) 6.4 (6.0) 10-8 3.3 (2.8) 4.4 (4.0) 4.5 (4.2) 6.9 (6.5) 8PSK 3/4 7/8 0.95 10-6 6.2 (5.8) 7.0 (6.6) 9.3 (8.9) 10-8 6.8 (6.3) 7.2 (6.8) 10.3 (9.9) 8-QAM 3/4 7/8 0.95 10-6 6.5 (6.1) 6.6 (6.2) 9.6 (9.2) 10-6 7.2 (6.8) 6.8 (6.4) 10.6(10.2) 16-QAM 3/4 7/8 10-6 7.4 (7.0) 8.1 (7.7) 10-7 7.8 (7.3) 8.2 (7.8) 10-7 8.2 (7.7) 8.3 (7.9) Low-Noise Block Converter (LNB) Support (CDM-570L & CDM-570L-IP Only) LNB Voltage LNB Reference +13, +18, and +24 VDC @ 500 ma maximum 10 MHz via RX center conductor, -3 dbm ± 3 db Block Up Converter (BUC) Support (CDM-570L & CDM-570L-IP Only) BUC Voltage 24 VDC, 90 W @ 50 C, 100 W @ 30 C (internally fitted option) 48 VDC, 150 W @ 50 C, 180 W @ 30 C (internally fitted option, not available with -24 VDC BUC Reference FSK Support input) 10 MHz via TX center conductor, 0 dbm ± 3 db Via TX center conductor with FSK BUCs

Environmental & Physical Temperature Power Supply Power Consumption (See Manual) Dimensions (height x width x depth) Weight Operations & Maintenance Configuration and Management Software/firmware upgrade via FTP IP traffic statistics Faults and alarms Configuration backup and restoral Security Password protection Access list Accessories CRS-170A CRS-180 CRS-280 CRS-280L CRS-300 Operating: 0 to 50 C (32 to 122 F) Storage: -25 to 85 C (-13 to 185 F) 100 to 240 VAC, 50/60 Hz -24 VDC (HW option) -48 VDC (HW option) CDM-570: 29 W typical (32 W max.) CDM-570-IP: 37 W typical CDM-570L: 29 W typical (32 W max.) w/o BUC CDM-570L-IP: 37 W typical w/o BUC CDM-570-IP: 1.75 x 19 x 12 (4.4 x 48.3 x 30.5 cm) CDM-570L-IP: 1.75 x 19 x 16 (4.4 x 48.3 x 40.6 cm) CDM-570 & CDM-570-IP: 6 lbs (2.7 kg) CDM-570L: 7 lbs (3.2 kg) (without BUC P/S) CDM-570L & CDM-570L-IP: 16 lbs (7.2 kg) including 150 W BUC power supply Front panel Remote port EIA-232 or EIA-485 (2- or 4-wire) SNMP with MIB II and private, modem-specific MIB Telnet Web browser (HTTP) Console interface (EIA-232, RJ-12 connector) CDM-570L & CDM-570L-IP: 1:1 Modem Redundancy IF Switch CDM-570 & CDM-570-IP: 1:1 Modem Redundancy IF Switch CDM-570: 1:N Modem Redundancy IF Switch Module CDM-570L: 1:N Modem Redundancy IF Switch Module CDM-570 & CDM-570L: 1:10 Modem Redundancy Switch Available Options How Enabled Networking Protocols RFC 768 UDP RFC 791 IP RFC 792 ICMP RFC 793 TCP RFC 826 ARP RFC 856 Telnet RFC 862 Ping RFC 894 IP RFC 959 FTP RFC 1112 IP Multicast RFC 1213 SNMP MIB II RFC 1812 IPv4 Routers Option Variable rate to 2.048 Mbps Variable rate to 5 Mbps Variable rate to 9.98 Mbps 8PSK, 8-QAM modulation (8-QAM with TPC only) 16-QAM modulation G.703 clock extension (requires G.703 E1/T1 interface option) G.703 E1/T1 interface Reed-Solomon Codec board Turbo Codec board Power supply, AC input Power supply, -24 VDC input Power supply, -48 VDC input 24 VDC, 90 W @ 50 C (100 W @ 30 C) BUC power supply, AC input, -24 or -48 VDC input 48 VDC, 150 W @ 50 C (180 W @ 30 C) BUC power supply, AC input or -48 VDC input IP Module IP Module Options Header compression Payload compression Quality of Service (QoS) 3 modes Vipersat Management System Integration RFC 2045 MIME RFC 2236 IGMP v2 RFC 2474 Diffserv RFC 2475 Diffserv RFC 2578 SMI RFC 2597 AF PHB RFC 2598 Expedite Forwarding RFC 2616 HTTP RFC 2821 SMTP RFC 3412 SNMP RFC 3416 SNMPv2 RFC 3418 SNMP MIB Regulatory CE Mark FCC EN 301 489-1 (ERM) EN55022 (Emissions) EN55024 (Immunity) EN 61000 3 2 EN 61000 3 3 EN60950 (Safety) FCC Part 15, Subpart B CDM-570/L-IP Satellite Modem back panel 2114 West 7th Street, Tempe, Arizona 85281 USA Voice: +1.480.333.2200 Fax: +1.480.333.2540 Email: sales@comtechefdata.com See all of Comtech EF Data s Patents and Patents Pending at http://patents.comtechefdata.com Comtech EF Data reserves the right to change specifications of products described in this document at any time without notice and without obligation to notify any person of such changes. Information in this document may differ from that published in other Comtech EF Data documents. Refer to the website or contact Customer Service for the latest released product information 2013 Comtech EF Data ds-cdm570-ip_570l-ip.docx 10/7/2013

CDM-570-IPEN & CDM-570/L-IPEN Satellite Modems Satellite Modems Overview The CDM-570-IPEN and the CDM-570L-IPEN are IP-centric satellite modems with data encryption that provide industry leading performance and flexibility in a 1RU package. With their innovative architecture and support for advanced capabilities, CDM-570-IPEN and CDM-570L- IPEN allow for efficient IP networking and transport over satellite links while supporting a wide range of applications and network topologies. In addition to the 10/100Base-T Ethernet interface, a wide range of data interfaces are available to support legacy applications and assist in migrating from legacy to IP transport. The advanced FPGA-based architecture along with the internal Flash memory allows for easy field upgrades via the Ethernet port. Features Data rate range from 2.4 kbps to 9.98 Mbps CDM-570-IPEN: 50 to 90 or 100 to 180 MHz IF range CDM-570L-IPEN: 950 to 2000 MHz IF range Integrated IP Module with 10/100Base-T Ethernet port Static IP routing for unicast and multicast Multi-level Quality of Service (QoS) Header and payload compression for maximum efficiency 3xDES Encryption for transport security Standards based management via SNMP, Web, or Telnet IGMP v1 and v2 VLAN capability with 802.1Q compliant QoS Symmetric as well as asymmetric operation for maximum bandwidth efficiency Typical Users Enterprise Internet Service Providers Satellite Service Providers Offshore & Maritime Mobile Operators Common Applications Mobile Backhaul Communications onthe-move Disaster Recovery & Emergency Communications Enterprise Offshore & Maritime Communications Satellite News Gathering Support for mesh, star and hybrid network topologies Vipersat Management System (VMS) integration G.703 clock extension for IP backhaul (option)fast acquisition demodulator Fast acquisition demodulator Modulation types: BPSK, QPSK, OQPSK, 8PSK, Patented 8-QAM, 16-QAM Forward Error Correction (FEC) choices include Turbo Product Code (TPC), Viterbi, Reed-Solomon and Trellis Coded Modulation (TCM) Automatic Uplink Power Control (AUPC) Embedded Distant-end Monitor and Control (EDMAC) 1:1 Redundancy available CDM-570-IPEN: FSK communications to CSAT-5060 or KST-2000A CDM-570L-IPEN: 10 MHz reference for BUC, FSK communications and optional BUC power supply CDM-570L-IPEN: 10 MHz reference and power supply for LNB Integrated IP Capability With their innovative architecture and support for advanced capabilities, CDM-570/L-IPEN allows for efficient IP networking and transport over satellite. CDM-570/L-IPEN supports a wide range of applications and network topologies. Data Encryption Configurable on a per route basis, the modems supports 3xDES data encryption for transmission security to prevent unauthorized access to data transmitted over the satellite link. www.comtechefdata.com

Header Compression (Option) Configurable on a per route basis, header compression reduces the bandwidth required for VoIP by as much as 60%. Example: A G.729 voice codec, operating at 8 kbps, requires 32 kbps bandwidth once encapsulated into an IP/UDP/RTP frame. With compression, the same voice call needs only 10.8 kbps total WAN satellite bandwidth. Typical Web/HTTP traffic can also be reduced by 10% via IP/TCP header compression. Payload Compression (Option) Configurable on a per route basis, payload compression can reduce the required satellite bandwidth by up to 40%. Quality of Service (QoS) (Option) The modems supports multi-level QoS to reduce jitter and latency for real time traffic, provides priority treatment to mission critical applications and allows non-critical traffic to use the remaining bandwidth. Supported modes are: DiffServ Industry-standard method of providing QoS enabling seamless co-existence in networks that implement DiffServ. Max/Priority Provides eight levels of traffic prioritization with the ability to limit maximum traffic per priority class Min/Max Provides a Committed Information Rate (CIR) to each user defined class of traffic with the ability to allow a higher burstable rate depending on availability Turbo Product Coding The optional Turbo Product Codec delivers significant performance improvement when compared to Viterbi with concatenated Reed- Solomon. It offers increased coding gain, lower decoding delay, and significant bandwidth savings compared to traditional FEC. Management The modems support SNMP, web-based and command line interfaces for management. The modems can also be configured and monitored from the front panel, or through the remote M&C port (for non-ip mode of operation). Ten complete RF configurations may be stored in the modems. An event log stores alarm and status information in non-volatile RAM, while the link statistics log stores link performance (Eb/No and AUPC performance) for monitoring and reporting purposes. G.703 Clock Extension Mobile networks require precise synchronization of base stations, which is a challenge when using IP backhaul. Most operators are forced to use GPS-based external equipment for site synchronization. CDM-570/L-IPEN offers a G.703 clock extension option that propagates a high stability reference from hub to the remote. This process does not require additional bandwidth. EDMAC & AUPC Operation The CDM-570/L-IPEN has the ability to monitor and control the distant end of a point-to-point satellite link using EDMAC or EDMAC2. User data is framed and bits are added to pass control, status, and AUPC information. AUPC can be used to automatically adjust the transmit power based on the Eb/No feedback from the distant end modem. EDMAC operation is transparent to the user. Feature Enhancements The codes make it easy to upgrade the modem capability in the field. New features can be added on site, using access codes purchased from Comtech EF Data that can be entered via the front panel. Vipersat Management System Dynamic SCPC carrier allocation & true bandwidth-on-demand User-defined policies for upstream carrier switching Star and full mesh capabilities using single hop on-demand Advanced switching takes advantage of using other modulation/forward error correction combinations Guaranteed bandwidth capability VMS Network & Bandwidth Management A Vipersat-powered network integrates these advanced modems with a powerful network management tool, the Vipersat Management System (VMS). In addition to the traditional monitoring and control of the CDM-570/L-IPEN modems and the CDD-564/LEN and CDD- 562LEN demodulators, the VMS allows these devices to share bandwidth, and when needed, switch automatically to a dedicated SCPC channel. In a Vipersat-powered network, the CDM-570/L-IPEN modem takes advantage of its fast acquisition demodulation to allow it to operate in a shared mode. Inbound transmissions (from remote to hub) can be switched from a shared Selective Time Division Multiple Access (STDMA) mode to a dedicated Single Carrier Per Channel (SCPC) connection via a variety of user defined policies or triggers. This enables the network to more effectively handle real-time connection-oriented applications and reduces both latency and network congestion. Through VMS, dynamic point-to-point mesh connections can also be established between remotes. Upstream Switching Through protocol classification in the remote terminals, the modem initiates automatic switching. VMS establishes dscpc bandwidth based on policies that can be individually enabled on a per-remote basis, or globally enabled. Policies can be configured for a variety of applications such as VoIP, video (VTC), or based on a load, or via a schedule, Type of Service (ToS), or QoS rules such as IP port or IP address and protocol type. Operators are able to set minimum and maximum data rates for each remote, as well as excess data rates for an initial upstream switch. Vipersat Operation Mode Vipersat operation is enabled via a feature code. Networks can initially be deployed in fixed point-to-point or point-to-multipoint configurations. As the network grows and users wish to take advantage of the bandwidth on-demand savings by implementing a Vipersat network, modems can easily be upgraded to Vipersat mode. Vipersat mode provides for the ability to operate in the following modulation/fec rates:

Specifications Frequency Range CDM-570-IPEN: 50 to 90 or 100 to 180 MHz, 100 Hz resolution CDM-570L-IPEN: 950 to 2000 MHz, 100 Hz resolution Data Interfaces 10/100Base-T Ethernet, EIA-422/-530 DCE, V.35 DCE, Sync EIA-232, G.703 T1 balanced (option), G.703 E1 balanced or unbalanced (option) Data Rate Range (See user manual for details) Modulation & FEC 2.4 kbps to 9.98 Mbps (depending on modulation, FEC and framing), 1 bps step with fully independent TX and RX rates Data Rate Range 5/16 BPSK TPC 2.4 kbps to 0.937 Mbps 21/44 BPSK TPC 2.4 kbps to 1.430 Mbps 1/2 BPSK 2.4 kbps to 1.500 Mbps 1/2 QPSK/OQPSK 4.8 kbps to 3.000 Mbps 3/4 QPSK/OQPSK 7.2 kbps to 4.500 Mbps 7/8 QPSK/OQPSK 8.4 kbps to 5.250 Mbps 2/3 8PSK TCM 8.7 kbps to 4.400 Mbps 21/44 QPSK/OQPSK TPC 4.8 kbps to 2.860 Mbps 3/4 QPSK/OQPSK TPC 7.2 kbps to 4.500 Mbps 7/8 QPSK/OQPSK TPC 8.4 kbps to 5.250 Mbps 0.95 QPSK/OQPSK TPC 9.1 kbps to 5.666 Mbps 3/4 8PSK/8-QAM TPC 10.8 kbps to 6.750 Mbps 7/8 8PSK/8-QAM TPC 13.6 kbps to 7.875 Mbps 0.95 8PSK/8-QAM TPC 15.3 kbps to 8.500 Mbps 3/4 16-QAM TPC 14.4 kbps to 9.000 Mbps 7/8 16-QAM TPC 16.8 kbps to 9.980 Mbps Uncoded BPSK 4.8 kbps to 3.000 Mbps Uncoded QPSK/OQPSK 9.6 kbps to 5.000 Mbps Note: Data rate specifications reflect CDM-570-IP or CDM-570L-IPEN modem operating in non-vipersat mode Scrambling Mode dependent - ITU V.35, or proprietary externally synchronized FEC Options Viterbi Rate 1/2 BPSK, QPSK/OQPSK Rate 3/4 and 7/8 QPSK/OQPSK and 16-QAM w/rs TCM 8PSK 2/3 (Closed network not IESS-310) Turbo Product Coding Rate 21/44 BPSK, 5/16 BPSK, Rate 21/44 QPSK/OQPSK Rate 3/4 and Rate 7/8 QPSK/OQPSK, 8PSK/8-QAM and 16-QAM Rate 0.95 QPSK/OQPSK and 8PSK/8-QAM Reed-Solomon Proprietary 220/200 and 200/180 modes available Uncoded BPSK, QPSK/OQPSK M&C Interface Ethernet 10/100Base-T EIA-232, EIA-485 (2- or 4-wire), (Dependent on operational mode) Input/Output Impedance CDM-570-IPEN: Matched for 50/75 Ω, BNC connector CDM-570L-IPEN: transmit and receive 50 Ω, female Type N connector External Reference Input 1, 2, 5, 10 or 20 MHz, BNC connector Form C Relays TX, RX traffic alarms and unit faults Modulator STDMA QPSK, Rate 3/4 Turbo FEC all STDMA modes Data Rate Range: 64 kbps 4.5 Mbps BPSK, Rate 5/16 Turbo FEC Entry Channel Mode only Data Rate Range: 32 kbps to 937 kbps CDM-570-IPEN CDM-570L-IPEN Frequency Stability ± 1 ppm, 0º to 50ºC (32º to 122ºF) ±0.06 ppm, 0º to 50ºC (32º to 122ºF) Output Power 0 to 25 dbm, 0.1 db steps 0 to 40 dbm, 0.1 db steps Accuracy ± 0.5 db over frequency and temperature ± 1.0 db over frequency and temperature Phase Noise < 0.75 degrees RMS double-sided, 100 Hz to 1 MHz < 1.2 degrees RMS double-sided, 100 Hz to 1 MHz Output Spectrum/ Meets IESS-308/-309 power spectral mask Filtering Harmonics and Spurious < -55 dbc/4 khz (Typically < -60 dbc/4 khz) Transmit On/Off Ratio 55 db minimum External TX Carrier Off By TTL LOW signal, or RTS TX Clock Options Internal (SCT), external (TT), loop timing with symmetric or asymmetric operation (Data interface dependent) SCPC All Turbo Product Code FEC rates as detailed in the following specifications Demodulator CDM-570-IPEN CDM-570L-IPEN Input Power Range -30 to -60 dbm -130 + 10 log symbol rate, dbm (minimum) -90 + 10 log symbol rate, dbm (maximum) Max Composite Level +35 dbc, up to -5 dbm absolute max. +40 dbc, up to -10 dbm absolute max. Acquisition Range ± 1 to ± 32 khz, 1 khz step ± 1 to ± 32 khz, 1 khz step, symbol rate <= 625 ksps ± 1 to ± 200 khz, 1 khz step, symbol Rate > 625 ksps Acquisition Time Highly dependent on data rate, FEC rate, and demodulator acquisition range. Example: 120 ms average at 64 kbps, Rate 1/2 QPSK, ± 10 khz acquisition sweep range, 6dB Eb/No Receive Buffer 512, 1024, 2048, 4096, 8182, or 16384 bits Receive Clock Options Buffer disabled (RX satellite), buffer enabled (symmetric or asymmetric operation) (data interface dependent) Clock Tracking ± 100 ppm minimum Monitor Functions E b/n o, frequency offset, BER, buffer fill status, RX signal level Example BER Performance For symbol rates up to 2.5 Msps (See user s manual for higher symbol rates). Guaranteed E b/n o, in db (typical values in parentheses) with two adjacent carriers 7 db higher. (See the user s manual for a complete listing of the performance of all FEC types, code rates, and modulation types.) Viterbi BPSK, QPSK/OQPSK 1/2 3/4 7/8 10-5 5.4 (4.9) 6.8 (6.3) 7.7 (7.2) 10-7 6.7 (6.2) 8.2 (7.7) 9.0 (8.6) Viterbi & Concatenated Reed-Solomon 220/200 or 200/180 BPSK, QPSK/OQPSK 1/2 3/4 7/8 10-5 4.3 (4.0) 5.6 (4.7) 6.5 (6.0) 10-7 4.5 (4.2) 6.0 (5.2) 6.9 (6.5) Turbo Product Codec BPSK 5/16 21/44 10-6 2.4 (2.1) 2.8 (2.5) 10-7 2.6 (2.3) 3.1 (2.8) 10-8 2.7 (2.4) 3.3 (2.9) QPSK/OQPSK 21/44 3/4 7/8 0.95 10-6 2.9 (2.6) 3.8 (3.4) 4.3 (4.0) 6.4 (6.0) 10-8 3.3 (2.8) 4.4 (4.0) 4.5 (4.2) 6.9 (6.5) 8PSK 3/4 7/8 0.95 10-6 6.2 (5.8) 7.0 (6.6) 9.3 (8.9) 10-8 6.8 (6.3) 7.2 (6.8) 10.3 (9.9) 8-QAM 3/4 7/8 0.95 10-6 6.5 (6.1) 6.6 (6.2) 9.6 (9.2) 10-6 7.2 (6.8) 6.8 (6.4) 10.6(10.2) 16-QAM 3/4 7/8 10-6 7.4 (7.0) 8.1 (7.7) 10-7 7.8 (7.3) 8.2 (7.8) 10-7 8.2 (7.7) 8.3 (7.9) Low-Noise Block Converter (LNB) Support (CDM-570L-IPEN Only) LNB Voltage LNB Reference +13, +18, and +24 VDC @ 500 ma maximum 10 MHz via RX center conductor, -3 dbm ± 3 db

Block Up Converter (BUC) Support (CDM-570L-IPEN Only) BUC Voltage 24 VDC, 90 W @ 50 C, 100 W @ 30 C (internally fitted option) 48 VDC, 150 W @ 50 C, 180 W @ 30 C (internally fitted option, not available with -24 VDC BUC Reference FSK Support Environmental & Physical Temperature Power Supply Power Consumption (See Manual) Dimensions (height x width x depth) Weight Operations & Maintenance Configuration and Management Software/firmware upgrade via FTP IP traffic statistics Faults and alarms Configuration backup and restoral Security Password protection Access list Accessories CRS-170A CRS-180 input) 10 MHz via TX center conductor, 0 dbm ± 3 db Via TX center conductor with FSK BUCs Operating: 0 to 50 C (32 to 122 F) Storage: -25 to 85 C (-13 to 185 F) 100 to 240 VAC, 50/60 Hz -24 VDC (HW option) -48 VDC (HW option) CDM-570-IPEN: 37 W typical CDM-570L-IPEN: 37 W typical w/o BUC CDM-570-IPEN: 1.75 x 19 x 12 (4.4 x 48.3 x 30.5 cm) CDM-570L-IPEN: 1.75 x 19 x 16 (4.4 x 48.3 x 40.6 cm) CDM-570-IPEN: 6 lbs (2.7 kg) CDM-570L-IPEN: 7 lbs (3.2 kg) (without BUC P/S) CDM-570L-IPEN: 16 lbs (7.2 kg) including 150 W BUC power supply Front panel Remote port EIA-232 or EIA-485 (2- or 4-wire) SNMP with MIB II and private, modem-specific MIB Telnet Web browser (HTTP) Console interface (EIA-232, RJ-12 connector) CDM-570L-IPEN: 1:1 Modem Redundancy IF Switch CDM-570-IPEN: 1:1 Modem Redundancy IF Switch Regulatory CE Mark FCC Available Options How Enabled Networking Protocols RFC 768 UDP RFC 791 IP RFC 792 ICMP RFC 793 TCP RFC 826 ARP RFC 856 Telnet RFC 862 Ping RFC 894 IP RFC 959 FTP RFC 1112 IP Multicast RFC 1213 SNMP MIB II RFC 1812 IPv4 Routers EN 301 489-1 (ERM) EN55022 (Emissions) EN55024 (Immunity) EN 61000 3 2 EN 61000 3 3 EN60950 (Safety) FCC Part 15, Subpart B Option Variable rate to 2.048 Mbps Variable rate to 5 Mbps Variable rate to 9.98 Mbps 8PSK, 8-QAM modulation (8-QAM with TPC only) 16-QAM modulation G.703 clock extension (Requires G.703 E1/T1 interface option) G.703 E1/T1 interface Reed-Solomon Codec board Turbo Codec board Power supply, AC input Power supply, -24 VDC input Power supply, -48 VDC input 24 VDC, 90 W @ 50 C (100 W @ 30 C) BUC power supply, AC Input, -24 or -48 VDC input 48 VDC, 150 W @ 50 C (180 W @ 30 C) BUC power supply, AC input or -48 VDC input Variable rate to 2.048 Mbps IP Module Options: Header compression Payload compression Quality of Service (QoS) 3 modes Vipersat Management System integration RFC 2045 MIME RFC 2236 IGMP v2 RFC 2474 Diffserv RFC 2475 Diffserv RFC 2578 SMI RFC 2597 AF PHB RFC 2598 Expedite Forwarding RFC 2616 HTTP RFC 2821 SMTP RFC 3412 SNMP RFC 3416 SNMPv2 RFC 3418 SNMP MIB CDM-570L-IPEN Satellite Modem back panel 2114 West 7th Street, Tempe, Arizona 85281 USA Voice: +1.480.333.2200 Fax: +1.480.333.2540 Email: sales@comtechefdata.com See all of Comtech EF Data s Patents and Patents Pending at http://patents.comtechefdata.com Comtech EF Data reserves the right to change specifications of products described in this document at any time without notice and without obligation to notify any person of such changes. Information in this document may differ from that published in other Comtech EF Data documents. Refer to the website or contact Customer Service for the latest released product information 2013 Comtech EF Data ds-cdm570-ipen-570l-ipen.docx 10/7/2013