Agilent L4433A Dual/Quad 4x8 Reed Matrix

Similar documents
Agilent L4421A 40-Channel Armature Multiplexer

Agilent L4445A Microwave Switch/Attenuator Driver

Agilent L4450A 64-Bit Digital I/O with Memory and Counter

Keysight L4445A Microwave Switch/Attenuator Driver. Data Sheet

Agilent U2751A USB Modular Switch Matrix. Data Sheet

Keysight L4445A Microwave Switch/Attenuator Driver. Data Sheet

Keysight Technologies L4450A 64-Bit Digital I/O with Memory and Counter. Data Sheet

Keysight L4451A 4-Channel Isolated D/A Converter with Memory. Data Sheet

Agilent U2600A Series USB Isolated Digital I/O Devices. Data Sheet

Agilent U2751A USB Modular Switch Matrix. Data Sheet

E2625A Communication Mask Test Kit E2698A Ethernet Masks

Technical Specifications May 2003

34970A 3499A/B/C. Advanced Test Equipment Rentals ATEC (2832) 34970A and 3499A/B/C Switch Systems

Keysight U2751A USB Modular Switch Matrix

Agilent Noise Source Calibration Using the Agilent N8975A Noise Figure Analyzer and the N2002A Noise Source Test Set. Technical Overview

Agilent I/O Hardware for PC-to-Instrument Connection Data Sheet

Agilent Technologies E5900B Emulation Probes

Agilent E3640A E3649A Programmable DC Power Supplies

Single-Output 2000 W GPIB

Agilent E363xA Series Programmable DC Power Supplies

Modular Power System 1200 W per mainframe GPIB

Side-by-Side Comparison: Agilent N5700 System DC Source and Xantrex XFR DC Power Supply

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Agilent CDMA Base Station Over-Air Maintenance Tool

Agilent U8000 Series Single Output DC Power Supplies. Data Sheet

Benefits of a Switch/Measure Unit for Data Acquisition and Electronic Functional Test

Agilent 11713B/C Attenuator/Switch Driver

Agilent ENA RF Network Analyzer

Agilent 8703A. Lightwave. Configuration Guide nm or 1550 nm 130 MHz to 20 GHz modulation bandwidth. Example Configuration:

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz Product Overview

Agilent 87406B Coaxial Matrix Switch dc to 20 GHz Product Overview

Agilent 66000A 1200 W DC Modular Power System, GPIB

Agilent 8960 Wireless Test Set Ensures the Success of Your Wireless Products

Agilent Technologies VQT Phone Adapter J1996A

Agilent RF Network Analyzers PNA Series

6640A Series Single-Output, 200 W DC Power Supplies, GPIB

Easy Steps to Integrate the 34405A Multimeter into a System

High Density Switch Mainframe and Cards

Agilent Noise Source Calibration Using the Agilent N8975A Noise Figure Analyzer and the N2002A Noise Source Test Set. Product Note

Utilization of Agilent s Remote Management Cards RMC Plus L/LS 1.0 (N2521A-AT1/N2521A-AT3) in Intel s. Performance Appliance Platform.

Agilent U2600A Series USB Modular Isolated Digital I/O Devices. Data Sheet

How to Convert from a Xantrex XFR to an Agilent N5700

Agilent U2941A Parametric Test Fixture

Keysight U2751A USB Modular Switch Matrix

Agilent U2722A USB Modular Source Measure Unit. Data Sheet

Mobile Communications DC Sources W

Agilent Technologies IP Telephony Reporter J5422A

Agilent E36XXA Series Non-Programmable DC Power Supplies. Data Sheet

Agilent Technologies E2688A, N5384A High-Speed Serial Data Analysis and Clock Recovery Software for Infiniium Oscilloscopes

Agilent 87204/87206A, B, C Multiport Coaxial Switches dc to 4 GHz, dc to 20 GHz, dc to 26.5 GHz

Current Drain Analysis Enhances WLAN Network Card Design and Test

Evaluating Battery Run-down Performance Using the Agilent 66319D or 66321D with Option # A Device Characterization Software

Agilent 1GC GHz Integrated Diode Limiter TC231P Data Sheet

Agilent 34450A 5.5 Digit Bench Digital Multimeter. Turbo charge your measurements with one of the fastest throughput digital multimeter in its class

Automatic protection switching. OmniBER playing a more active role

Agilent E5061B Network Analyzer. Configuration Guide

Agilent E5818A LXI Class-B Trigger Box. Data Sheet

Agilent Technologies N5393A PCI Express Electrical Performance Validation and Compliance Software for Infiniium 54855A or Series Oscilloscopes

How to Convert from a Sorensen DLM to an Agilent N5700

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Using the Agilent Technologies Series Logic Analysis System with the Xilinx ChipScope ILA

Agilent 7061A and 87130A Switch Attenuator Drivers

Keysight U2751A USB Modular Switch Matrix

Agilent M9036A PXIe Embedded Controller

BRIC MODULE BRIC ANALOG BACKPLANE BUS MATRIX INPUTS DAUGHTER CARD #3 RESOURCE DISTRIBUTOR DAUGHTER CARD #2

Agilent U2100A Series Digital IO, 32-Terminal Devices

VISA, SICL, VISA COM,

Alarm stress testing G.709. Application note. OmniBER OTN communications performance analyzer

Agilent E4982A LCR Meter

Agilent E5072A ENA Series Network Analyzer

On-Chip Design Verification with Xilinx FPGAs

W2630 Series DDR2 BGA Probes for Logic Analyzers and Oscilloscopes

System Developer Guide Using LAN in Test Systems: PC Configuration

AgilentTechnologies TS-50 RF Shielded Test Fixtures

Model 707B / 708B Switching Matrix Mainframe Specifications Model 707B Six Slots with Fixed Rack Model 708B Single Slot with Fixed Rack

Agilent Modern Connectivity Using USB and LAN I/O Converters

Model 3724 Dual 1x30 FET Multiplexer Card

Keysight M9352A PXI Hybrid Amplifier/Attenuator. Data Sheet

Agilent 87104/87106A, B, C Multiport Coaxial Switches dc to 4 GHz, dc to 20 GHz, dc to 26.5 GHz

Agilent E7478A GPRS Drive Test System

Agilent N1918A Power Analysis Manager

Advanced Test Equipment Rentals ATEC (2832) Why Migrate from HP/Agilent 432A/B to Agilent N432A Thermistor Power Meter?

Agilent N4880A Reference Clock Multiplier

Agilent Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes

PCI Express Protocol Triggering and Decode for Infiniium 9000 Series Oscilloscopes

DT8824 High Stability, High Accuracy, Ethernet Instrument Module

Agilent Lightwave Solution Platform

Agilent Strain Measurement Application Using Agilent U2300A Series Data Acquisition Devices With Agilent VEE Pro. Application Note

Fluke 8845A/8846A Digital Multimeters. Precision and versatility for bench or systems applications

Agilent N1203/4/7C Beam Manipulators and N1206T Adjustment Tool Kit

Agilent Connectivity Hardware for PC-to-Instrument Connections. Data Sheet. with Agilent GPIB and Instrument Control Products

Agilent Technologies 6000L Series Low-Profile Oscilloscopes. The most space efficient LXI C compliant oscilloscopes. Four channels in only 1U space

MXG X-Series Signal Generators N5181B Analog & N5182B Vector. Configuration Guide

Keysight Technologies PXI Multiplexer Switch Modules

Technical Overview. Key Features

Agilent Microwave Sweep Oscillator and Network Analyzer Instrument Security

Fluke 8845A/8846A Digital Multimeters. Precision and versatility for bench or systems applications

M9502A and M9505A 2- and 5-slot AXIe Chassis PCIe Gen 2, 2 GB/s slot BW, up to 200 W/slot

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

Agilent Upgrade Guide for the 8510 Vector Network Analyzer Product Note

Transcription:

Agilent L4433A Dual/Quad 4x8 Reed Matrix Data Sheet LXI compliance includes built-in Ethernet connectivity Fully-featured graphical Web interface Dual 4x8, 8x8, or 4x16 2-wire configurations 64 2-wire or 128 1-wire cross-points High speed reed relays Analog bus connection Relay counter ±150 V peak, 0.5 A switch, 1.5 A carry current Software drivers for most common programming environments Dual/quad 4x8 Matrix offers high-performance signal switching wherever your application needs it The Agilent L4433A is a high-speed reed relay matrix that is LXI Class C compliant. With its small size and Ethernet connectivity, this matrix can be placed wherever your application needs it. The Agilent L4433A offers a flexible connection path between your device under test and your test equipment, allowing different instruments to be connected to multiple points on your device under test at the same time. This instrument can be configured as a 2-wire or a 1-wire matrix, increasing the number of crosspoints. Multiple matrices can be combined through the analog buses connector to create a larger matrix. Using this LXI instrument, you ll get all the benefits of an Ethernet connection, instrument Web server, standard software drivers and more. The LXI standard is supported by multiple vendors, enabling lower cost of test with accelerated test integration and development.

Switch features for flexible and reliable connections The L4433A features a full cross-point matrix that allows you to connect any row to any column. This is a convenient way to connect multiple test instruments to multiple points on a device under test. With its high-speed reed relays you are ensured a fast response. Each cross-point in the matrix switch has two wires a high and a low for the measurement. Or, if you prefer, you can configure the L4433A as a single-wire matrix, increasing the number of crosspoints to 128. The L4433A also has in-rush resistors on each column for added protection. Expand your matrix using the analog bus connector to create a larger matrix, or easily connect to an external measurement device like a DMM. The sequence feature defines switch closures and controls and can be used to easily change between different switch setups. Assign a sequence, give it a name and then execute it with the custom name you created. External trigger capabilities make it easy for you to time and synchronize switch closures and openings. Figure 1. L4433A Dual/Quad 4 x 8 Real Matrix The L4433A also includes a relay counter to monitor and help predict when relays are nearing their end of life. Easily route signals to an external DMM The L4433A switches support signals up to ±150 V and 0.5 A so that no external signal conditioning is required. The analog bus connector can be used to easily route your matix switch signals to an external device. System connections you can trust The L4433A comes with 2 heavy duty 50-pin Dsub connectors that allow for simple, reliable connection options. Each connector uses 30 micro-inches of gold to ensure a repeatable, accurate measurement. Flexible connection options include: Detachable terminal blocks with strain relief Low-cost, standard 50-pin Dsub connector kits and cables Mass interconnect solutions Ethernet connectivity enables simple connection to the network and remote access to measurements The Ethernet interface offers high-speed connections that allow for remote access and control. You can set up a private network to filter out unwanted LAN traffic and speed up the I/O throughput, or take advantage of the remote capabilities and distribute your tests worldwide. Monitor, troubleshoot, or 2

debug your application remotely. Ethernet communication also can be used with the support of LAN sockets connections. The optional GPIB interface has many years of proven reliability and can be used for easy integration into existing applications. The L4433A ships with the Agilent E2094N I/O Libraries Suite making it easy for you to configure and integrate instruments into your system even if your system includes instruments from multiple vendors. Fully-featured graphical Web interface makes it easy to set-up and troubleshoot your tests from anywhere in the world The built-in Web browser interface provides remote access and control of the instrument via a Java-enabled browser such as Internet Explorer. Using the Web interface, you can set up, troubleshoot, and maintain your instrument from remote locations. View and modify instrument setup Open or close switches Send, receive or view SCPI commands Figure 2. The Web interface makes it easy to set up, troubleshoot and maintain your test remotely Define and execute switch sequences View error queue Get status reports on relay counts, firmware revisions, and more Additionally, since the Web server is built into the instrument, you can access it on any operating system that supports the Web browser without having to install any special software. Password protection and LAN lockout are also provided to limit access for additional security. Software for most popular programming environments Full support for standard programming environments ensures compatibility and efficiency. You can use direct I/O with the software you already have and know, or use standard IVI and LabVIEW TM software drivers that provide compatibility with the most popular development environments: Agilent T&M Toolkit for Microsoft Visual Studio.NET and Agilent VEE Pro National Instruments LabVIEW, LabWindows/CVI, TestStand, and Switch Manager Microsoft C/C++ and Visual Basic 3

High-performance switching wherever your application needs it Power button Status LEDs Easy connection options with standard 50-pin cables or connector kits, or terminal blocks Optional GPIB Built-in Ethernet Analog bus for connection to other devices External trigger to synchronize events 4

Product Specifications Specifications and Characteristics Input characteristics (per channel) Channels/configurations Switch type dual 4x8 8x8, 4x16 quad 4x8, 1-wire Reed non-latching Max volts 1 ± 150 V peak 2 Max current (DC, AC RMS) Switch current 0.5 A 5 /0.05 A 8 Carry current 1.5 A 5 /0.05 A 8 Power (W, VA) 2,6 10 W 7 Volt-Hertz limit 10 8 General specifications Offset voltage 3 < 50 uv < 100 uv 1-wire Initial closed channel resistance 3 < 1.5 Ω 5 /200 Ω 8 DC Isolation (ch-ch, ch-earth) >10 GΩ AC characteristics Bandwidth at terminal block 4 30 MHz 5 /4 MHz 8 2 MHz 1-wire 300 khz -65 db 1 MHz -65 db 20 MHz -40 db Capacitance at terminal block HI-LO 80 pf LO earth 75 pf General characteristics Relay life typical Open /close time, typical Analog bus connection No load 1000 M 10 V, 100 ma 10 M Rated load 10 k 0.5 ms/0.5 ms Yes 1 DC or AC RMS voltage, channel-to-channel or channel-to-earth 2 Peak voltage, channel-to-channel or channel-to-earth 3 Into analog bus connector 4 50 Ohm source, 50 Ohm load, differential measurements verified (Sdd21) 5 With input resistors bypassed. Bypassing resistors will reduce lifetime of relays. See the rated load relay life characteristics. 6 Limited to 6 W channel resistance power loss per module 7 Power restrictions allow only 20 channels to be closed at one time 8 With 100 Ohm input protection resistors Measurement Accuracy For accuracy measurement specification, combine the DMM offset with the switch offset. Bandwidth of the switch may offset the accuracy of the AC measurement. 5

Product Specifications (continued) General specifications Power supply Universal 100 V to 240 V ±10% Power line frequency 50 Hz to 60 Hz ±10% automatically sensed Power consumption 15 VA Operating Environment Full accuracy for 0 C to 55 C Full accuracy to 80% R.H. at 40 C Pollution degree 1 of IEC 61010-1 Storage environment -40 C to 70 C Dimensions (H x W x L) 40.9 x 212.3 x 379.3 mm 1.61 x 8.36 x 14.93 in Weight 3.9 kg, 8.6 lbs Safety conforms to CSA, UL/IEC/EN 61010-1 EMC conforms to IEC/EN 61326-1, CISPR 11 Warranty 1 year Memory States 5 instrument states with user label in non-volatile memory 6

Product Specifications (continued) Software Agilent connectivity software included Agilent I/O Libraries Suite 14 or greater (E2094N) Minimum system requirements PC hardware Operating system 1 Intel Pentium 100 MHz, 64 Mbyte RAM, 210 Mbyte disk space Display 800x600, 256 colors, CD-ROM drive Windows 98 SE/NT/2000/XP Computer interfaces Standard LAN 10BaseT/100BaseTx Optional IEEE 488.2 GPIB Software driver support for programming languages Software drivers IVI-C and IVI-COM for Windows NT /2000/XP LabVIEW Compatible with programming tools and environments Agilent National Instruments Microsoft VEE Pro T&M Toolkit (reqs Visual Studio.NET) TestStand Measurement Studio LabWindows/CVI LabVIEW Switch Executive Visual Studio.NET C/C++ Visual Basic 6 1 Load I/O Libraries Version M for Windows NT support or version 14.0 for Windows 98 SE support 7

Ordering information L4433A Dual/quad 4x8 Reed Matrix Includes User s guide on CD, power cord, and Quick Start package Option -GPIB Adds GPIB interface Option 0B0 Deletes printed manual set, full documentation included on CD ROM Option ABA English printed manual set Connection Options Select terminal block for discrete wiring, cables or connector kits. Cables and connector kits require 2 per instrument. 34933T Terminal block for 34933A and L4433A dual 4x8 Matrix Y1135A 1.5 m 50-pin Dsub, M/F twisted pair with outer shield cable 300 V Y1136A 3 m 50-pin Dsub, M/F twisted pair with outer shield cable 300 V Y1139A Solder cup connector kit with female 50-pin Dsub Other accessories Y1160A Rack mount kit for L4400 series instrumentsracks 2 instruments side-by-side with sliding tray For additional information please visit: http://www.agilent.com/find/l4433a Related Agilent literature Data Sheets 5988-6302EN Agilent VEE Pro 5989-1441EN Agilent W1140A-TKT T&M Toolkit 2.0 with Test Automation 5989-1439EN Agilent E2094N I/O Libraries Suite 14 8

Agilent Technologies Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Two concepts underlie Agilent s overall support policy: Our Promise and Your Advantage. Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you receive your new Agilent equipment, we can help verify that it works properly and help with initial product operation. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Direct www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. Agilent Open www.agilent.com/find/open Agilent Open simplifies the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products. Agilent offers open connectivity for a broad range of system-ready instruments, open industry software, PC-standard I/O and global support, which are combined to more easily integrate test system development. www.agilent.com For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Phone or Fax United States: (tel) 800 829 4444 (fax) 800 829 4433 Canada: (tel) 877 894 4414 (fax) 800 746 4866 China: (tel) 800 810 0189 (fax) 800 820 2816 Europe: (tel) 31 20 547 2111 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Korea: (tel) (080) 769 0800 (fax) (080) 769 0900 Latin America: (tel) (305) 269 7500 Taiwan: (tel) 0800 047 866 (fax) 0800 286 331 Other Asia Pacific Countries: (tel) (65) 6375 8100 (fax) (65) 6755 0042 Email: tm_ap@agilent.com Contacts revised: 09/26/05 Product specifications and descriptions in this document subject to change without notice. Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation LabVIEW TM is a U.S. registered trademark of National Instruments Corporation Agilent Technologies, Inc. 2006 Printed in the USA, February 28, 2006 5989-4826EN Agilent Technologies