User's Guide. Cup Thermo-Anemometer. Model AN400

Similar documents
User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

Heavy Duty Mini Vane CFM Thermo Anemometer

User's Guide. Hot Wire Thermo-Anemometer Model

Digital Vane Thermo-Anemometer Model

User's Guide. Hot Wire Thermo-Anemometer Model Introduction

Heavy Duty CFM Thermo-Anemometer Model

User's Guide. Vane Thermo-Anemometer Datalogger. Model Introduction

User Guide. Moisture Meter. Model MO250

Heavy Duty Datalogger Module

Hygro Thermo-Anemometer Model

Mini Photo Tachometer Model Mini Contact Tachometer Model

User's Guide. Model Laser Photo Tachometer

User's Guide. Datalogging Light Meter with PC Interface. Model

Heavy Duty Datalogging Light Meter

SuperHeat Psychrometer Models RH350 and RH355 (kit)

Heavy Duty Datalogger Module

True RMS AC Voltage/Current Datalogger

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

User's Guide. Vibration Meter and Laser Combination Tachometer Model

Heavy Duty Vibration Meter

User's Guide. Heavy Duty Differential Pressure Manometer. Model

OPERATION MANUAL. Model : AM Wind speed measurement, pocket type, IP-65 CUP ANEMOMETER

User s Manual. Model and Sound Level Calibrators

User's Manual. Model Heavy Duty Datalogging Module with Windows Software

User Guide. ExStik TM Model RE300 Waterproof ORP Meter. Patent Pending RE300 ORP

Laser Photo/ Contact Tachometer. m/min. ft/min

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Patented

User's Guide. Model High Precision Quad Output DC Power Supply

User s Guide. 600A AC Clamp Meter. Model 38387

User's Guide. Digital Sound Level Meter. Model

User Guide. ExStik FL700. Fluoride Meter

User's Guide. Video Borescope. Model BR100

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

User's Guide. Extech AM A AC Analog Clamp Meter

User's Guide. Phase Sequence and Motor Rotation Tester Model

User's Guide. Power Analyzer Model Power Analyzer Datalogger Model Introduction

Heavy Duty Psychrometer + IR Thermometer Model HD500

User Guide. Heavy Duty Differential Pressure Manometer. Model HD750

User's Guide. Hot Wire Thermo-Anemometer. Model

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

Heavy Duty Hot Wire CFM Thermo-Anemometer

User's Guide. Temperature / Humidity Datalogger. Model 42270

Mini Environmental Quality Meter

Digital Sound Level Meter

Integrating Sound Level Datalogger Model

Mini Environmental Quality Meter

3-Axis G-Force Datalogger

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs

User's Manual. CFM/CMM Thermo Anemometer + InfraRed Thermometer. Model AN200 UNITS NEXT AREA RECALL. cf m/cmm Anemometer Thermometer AN200

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User's Manual. VA893 Thermo Anemometer

User's Manual Sound Level Alert Model SL130

User's Guide Video Borescope Model BR200

VANE ANEMOMETER HUMIDITY/TEMP.

User's Manual. Digital Sound Level Meter. Model

Large Vane CFM/CMM Thermo-Anemometer

Power Analyzer Datalogger Model

User's Guide. 1/16 th DIN ph Controller. Model 48PH2. Introduction

VANE ANEMOMETER BAROMETER HUMIDITY/TEMP. Model : ABH-4225

Anemometer SD Card Datalogger. Instruction Manual

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

Mini Environmental Quality Meter

Large Vane CFM/CMM Anemometer / Psychrometer

DIGITAL ANEMOMETER Model : AM-4203

User's Guide. Mini Microscope. Model MC108

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Mini Digital Multimeter

Oyster Meter ph-conductivity-tds-salinity-orp(mv)

User's Guide. Heavy Duty Conductivity / Temperature. Model Introduction

APO F T1 F T1-T2 ESC - 0 ENTER. [Limits] CLR? SET[ ] LOG READ SAVE READ SHIFT [OFS] [APO] MAX/MIN REL HOLD [TIME] T1-T2 TYPE T1/T2 TYPE T1/T2

Model ST-618. Instruction Manual. Digital Thermo-Anemometer. Digital Measurement Metrology, Inc PRECISION IS OUR VISION

CFM/CMM Hot-Wire Thermoanemometer

User's Guide. Model Noise Dosimeter with PC Interface. Introduction

TA 888 Hot Wire Anemometer

USER GUIDE Turbidity Meter Model TB400

USER MANUAL. Light Meter. Model LT510. Additional User Manual Translations available at

Dual Input, 3-Display Thermometer/Datalogger Model

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

ANEMOMETER OPERATION MANUAL. metal vane + air flow. Model : AM-4206M

Indoor Air Quality Meter/Datalogger

Mini Environmental Quality Meter

Vibration Meter and Laser Combination Tachometer

Autoranging Multimeter plus IR Thermometer Extech 450 Patented

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80

9 in 1 Anemometer, Humidity/Temp. meter, Light meter Pt 1000 Temp. ( optional ) Sport/Weather meter ENVIRONMENT METER Model : SP-8001

ENVIRONMENT METER WITH DATALOGGING SD CARD

USER MANUAL. Hygro-Thermometer. Model RHT510. Additional User Manual Translations available at

DAF4207SD USER S MANUAL

User Guide. Conductivity Meter. Model EC210

Torque Meter. Instruction Manual

The Specification of Hot Wire Anemometer Manual PCE-423

Temperature & Humidity Datalogger

Heavy Duty Pitot Tube Anemometer and Differential Pressure Manometer

Datalogging Hot Wire CFM Anemometer

Air velocity, Air flow, Type K/J thermometer Real time data logger, Data logger no., RS232 ANEMOMETER. Model : DAF2005MDL

Autoranging Mini Multimeter Model MN16A

4 in 1 Anemometer, Humidity Light Meter, Thermometer

Datalogging Conductivity/ TDS Meter. Instruction Manual

User's Guide. EasyView K-Type Thermometer. Model EA11A

Transcription:

User's Guide Cup Thermo-Anemometer Model AN400

Introduction Congratulations on your purchase of the Extech Cup Thermo-Anemometer. The AN400 measures air velocity in five units of measure: feet per minute (ft/min), meters per second (m/sec), miles per hour (MPH), kilometers per hour (km/hr), & nautical miles per hour (knots). The low-friction cup vane freely rotates in response to air flow. An internal thermistor allows the AN400 to measure air temperature in Centigrade or Fahrenheit units. This meter is shipped fully tested and calibrated and with proper use will provide years of reliable service. Meter Description 1. Cup vane 2. Temperature sensor 3. POWER: On/Off Logger: Store data with REC in display : Step through and recall stored data 4. HOLD: Freeze display Unit: Select measured units 5. REC: Enter Max/Min or Logger mode o C/ o F: Select measured units : Step through and recall stored data 6. LCD display 7. Battery compartment cap 2

Operation Connecting the Vane Cup 1. Place the cup vane on the top of the meter housing. 2. Rotate the top screw in a counter-clockwise Ñ direction until the screw is secured. Meter Power 1. Press the POWER button to turn the meter on. If the display does not switch on, check that four AAA batteries are installed. To access the battery compartment, remove the battery cover by rotating it in a counter-clockwise direction. 2. Press the POWER button to turn the meter off. 3. The meter is equipped with an AUTO POWER OFF feature. The meter automatically shuts off after 10 minutes to conserve battery energy. To disable this feature, press the REC button to enable the MIN/MAX function. Measuring Air Velocity and Temperature 1. Hold the meter vertically and place the cup sensor in the air stream under test. 2. Read the Air Velocity and Temperature measurements directly on the LCD display. Note: The temperature sensor is located in the upper right of the front panel. To avoid affecting the temperature reading, hold the lower portion of the meter when making measurements. Selecting the Temperature unit of measure ( o C/ o F) Press and Hold (>2 seconds) the REC/ o C/ o F key to toggle the temperature unit of measure. The display will indicate the currently selected unit of measure. Note: Temperature unit of measure cannot be changed if the Data Hold or Record function is on. Selecting the Air Velocity unit of measure To change the unit of measure for Air Velocity measurement, press and hold (>2 seconds) the HOLD/Unit button. The display will sequence through the measurement units. When the desired unit of measure is displayed, release the button. The current setting will be retained even after the meter is powered off. Note: Unit of Measure cannot be changed if the Data Hold or Record function is on. Data Hold To freeze the LCD display, momentarily press the HOLD button. The 'HOLD' icon will appear on the LCD and the reading will remain unchanged. Momentarily press the HOLD button again to return to normal operation (the 'HOLD' icon will switch off). 3

Record and Recall MIN / MAX Function 1. To begin capturing the Minimum (MIN) and Maximum (MAX) air velocity and temperature readings, momentarily press the REC key. The REC icon will be displayed. 2. Now, use the REC button to toggle the view from MIN to MAX and from MAX to MIN readings. The RECMAX or REC MIN will appear along with the recalled reading for convenience. 3. To delete the maximum or minimum value and record a new value, momentarily press the HOLD button while in either RECMAX or REC MIN mode. 4. To return to normal operation, press and hold the REC button until the REC, MAX, and MIN icons switch off. Datalogging Datalogging allows the user to store and recall up to 100 readings with the press of a button. 1. Momentarily press the REC button to display the REC icon in the display. 2. Press the Logger button to manually store a single reading into memory. The location number of the reading will appear in the main display (memory locations remaining will appear in the lower display) for 2 seconds and then the normal display will return. 3. To exit the datalogger, press and hold the REC button for >2 seconds. The REC icon will disappear. 4. To recall the stored data, momentarily press the HOLD button to display the HOLD icon. 5. Momentarily press the REC button to display the total number of data points stored in memory. ttl will also appear in the lower display. 6. Use the and buttons to scroll through the memory locations to view the logged readings. The units display will flash while in the recall mode. 7. The memory location will first appear in the display followed by the reading. 8. To exit the recall data function, press the momentarily HOLD button. Note: The selected unit of measure icon will flash continuously when the meter is in recall mode. Clearing Stored Data 1. Press and hold the REC button while turning the meter on to clear memory. 2. The LCD will indicate n in the main display and CLr in the lower display. 3. Momentarily press the button to display Y and CLr. 4. Press the HOLD/Unit button. When the LCD indicates null and CLr, the memory has been cleared. 4

Maintenance Battery Replacement The AN400 is powered by four 1.5V AAA batteries. When the low battery icon x appears on the LCD or if the display does not switch on when the POWER button is pressed, replace or install the batteries. 1. Twist off the battery compartment cap by rotating it counter-clockwise. 2. Replace the four AAA batteries observing polarity. 3. Replace the battery compartment cap. Cleaning and Storage Wipe the meter and vane with a damp cloth as needed. Do not apply abrasive, solvents, or other cleaners to the surface of the meter or vane. Store with the battery removed and avoid extreme temperature and humidity. Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies on sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website at www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Calibration and Repair Services Extech offers repair and calibration services for the products we sell. Extech also provides NIST certification for most products. Call the Customer Service Department for information on calibration services available for this product. Extech recommends that annual calibrations be performed to verify meter performance and accuracy. Support line (781) 890-7440 Technical support: Extension 200; E-mail: support@extech.com Repair & Returns: Extension 210; E-mail: repair@extech.com Product specifications subject to change without notice For the latest version of this User s Guide, Software updates, and other up-to-the-minute product information, visit our website: www.extech.com Extech Instruments Corporation, 285 Bear Hill Rd., Waltham, MA 02451 5

Specifications Circuit description Display Measurement units Data hold Sensor Structure Memory Recall Data Logger Auto Power off Sampling Time Water Resistance Operating Temperature Operating Humidity Power Supply Power Consumption Weight Dimensions Custom LSI microprocessor design Dual function 9999 count LCD display m/s, km/h, ft/min, knots, mph, Temperature o C/ o F Freezes reading on the display Air velocity sensor: Cup vane arm with low-friction ballbearing design. Temperature sensor: Precision thermistor Record and Recall Maximum (MAX) and Minimum (MIN) readings Manual store/recall of up to 100 data points After 10 minutes Approx. 1 second IP65 32 F to 122 F (0 C to 50 C) Max. 80% RH 4 x 1.5V AAA batteries Approx. 6.8mA DC (typical battery life: approx. 150 hrs) 0.4 lbs. (181g) Main instrument: 7.5 x 1.6 x1.3 (190 x 40 x 32mm) Cup Vane: 5.3 (135mm) diameter Air Velocity Range Specifications Measurement Range Resolution Accuracy (of full scale) ft/min (feet per minute) 144 6895 ft/min 1 ft/min ± (2% + 40 ft/min) m/s (meters per second) 0.9-35.0 m/s 0.1 m/s ± (2% + 0.2 m/sec) km/h (kilometers per hour) 2.5-126.0 km/h 0.1 km/h ± (2% + 0.8 km/hr) mph (miles per hour) 1.6-78.2 mph 0.1 mph ± (2% + 0.4 mph) knots (nautical miles per hour) 1.4 to 68.0 knots 0.1 knots ± (2% + 0.4 knots) Temperature Range Specifications Range Resolution Accuracy 32 o F to 122 o F (0 o C to 50 o C) 0.1 o F (0.1 o C) ± 1.5 o F (0.8 o C) Copyright 2006 Extech Instruments Corporation All rights reserved including the right of reproduction in whole or in part in any form. 6