The list below shows items not included with a SmartVDI-110 Server. Monitors Ethernet cables (copper) Fiber optic cables Keyboard and mouse

Similar documents
M1032W Engineering Workstation. The list below shows components included in an M1032W Engineering Workstation container.

M1034W Engineering Workstation

A6106D/A6106H Blade PC Quick Start Guide

A6106SLW Blade PC Quick Start Guide

R3161D Blade PC Quick Start Guide

R3092D and the Blade Chassis, Continued. BIOS and Pre-OS Video. PCoIP network cabling. About pre-os video. Enabling Accelerated Monitor Emulation

R3162D Blade PC Quick Start Guide

LifeSize ClearSea Installation Guide August 2012

CD8841 Thin Client. Overview. CD8841 thin client with integrated pedestal. The pictures below show CD8841 thin client features.

350 East Plumeria Drive San Jose, CA USA May

G3-APEX-ENT-32T. Apex technical specifications. Parts list

The SC812/SC812L Chassis Series Installation Guide

HP ProLiant MicroServer

High Performance Computing

Chassis (FRU) Replacement Guide

Manager Appliance Quick Start Guide

VelaSync HIGH-SPEED TIME SERVER. Quick Reference Guide

G3-GS-4P-16T. Parts list G3-GS-4P-16T technical specifications. The G3-GS-4P-16T is best suited for small data centers or at your network edge.

Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i3BNHXF. Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i5BNHXF

Workstation Rack-Mount 4 RU Workstation, 4 RU Rack-Mount, Hexa-Core 3.5 GHz CPU, 16 GB DDR4 RAM, 256 GB SSD

User Guide for NUC7i3DNHNC. Intel NUC7 Business, a Mini PC with Windows 10 NUC7i3DNHNC. User Guide

ReadyNAS OS 6 Rack-Mount Hardware Manual

Intel NUC Kit NUC6CAYS User Guide

Intel IP Network Server NSI2U

E4233. English. P-Series. ASUS PC (Desktop Barebone) Installation manual. Download the latest manual from the ASUS website:

Supports up to four 3.5-inch SAS/SATA drives. Drive bays 1 and 2 support NVMe SSDs. A size-converter

Rack Installation Instructions

User Guide for NUC7CJYSAL. Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL. User Guide

Front-loading drive bays 1 12 support 3.5-inch SAS/SATA drives. Optionally, front-loading drive bays 1 and 2 support 3.5-inch NVMe SSDs.

G3-GS-8P-1152T. Parts list. G3-GS-8P-1152T technical specifications. The G3-GS-8P-1152T is best suited for 40 Gb data centers.

Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH

Intel NUC7 Home, a Mini PC with Windows 10 NUC7i3BNHXF. Intel NUC7 Home, a Mini PC with Windows 10 NUC7i5BNHXF

Alienware Area-51 R5 Service Manual

Cisco HyperFlex HX220c M4 Node

Intel NUC Kit NUC7i7BNH, NUC7i5BNH & NUC7i3BNH User Guide. Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide

NEC Express5800/R120h-2M System Configuration Guide

V5420 Host Card Upgrade Kit for R3082D Quick Start Guide

Installing the Cisco Unified Videoconferencing 3545 MCU

HostEngine 3U Host Computer User Guide

HostEngine 4U Host Computer User Guide

QUICK START GUIDE. Fidelis Collector SA. Rev-I Collector SA (HP DL360-G10) Platforms.

Installation and Configuration Guide

Alienware X51 Service Manual

HostEngine 4U Host Computer User Guide

QUICK START GUIDE. Fidelis Network K2 Appliances. Rev-I K2 (HP DL360-G10) Platforms.

Rack Installation Instructions

CHASSIS INSTALLATION GUIDE

ZOTAC ZBOX User s Manual

HostEngine 4U Host Computer User Guide

NEC Express5800/R120e-1M System Configuration Guide

Essentials. Expected Discontinuance Q2'15 Limited 3-year Warranty Yes Extended Warranty Available

Intel NUC Kit NUC7i3BNHX1 with Intel Optane Memory. Intel NUC Kit NUC7i5BNHX1 with Intel Optane Memory

Quick start guide for p5 520 ( )

Fidelis Network High Capacity Collector QUICK START GUIDE. Rev-I Collector Controller Appliances Based on HP DL360-G9 and DL380-G9 Platforms

Data Center, Enterprise & ISP Network Solutions CONTENTS

Panzura Freedom Filer Installation Guide

User Guide for NUC7CJYSAL. Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL. User Guide

EVGA assumes you have purchased all necessary parts needed to allow for proper system functionality.

HostEngine 5URP24 Computer User Guide

AI Solution

Cisco MCS 7845-H1 Unified CallManager Appliance

Installation and Configuration Guide

Quick Installation Guide

Junos WebApp Secure 5.0 Hardware Guide

User Guide. Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i5BNKP. Intel NUC 7 Enthusiast, a Mini PC with Windows 10 NUC7i7BNKQ

ZOTAC ZBOX User s Manual

IBM Systems. Quick start guide for IBM System p5 505 ( )

Fidelis Network Sensor Appliances QUICK START GUIDE

ZOTAC ZBOX User s Manual

Intel NUC Kit NUC5i3MYHE & NUC5i5MYHE User Guide. Intel NUC Kit NUC5i3MYHE Intel NUC Kit NUC5i5MYHE User Guide

PRISMA VelaSync HIGH-SPEED TIME SERVER. Getting Started Guide

NEC Express5800/R120d-2M Configuration Guide

350 East Plumeria Drive San Jose, CA USA February

Altos R320 F3 Specifications. Product overview. Product views. Internal view

Cisco CDE465 DIMM Reseating and Replacement Procedure. Modification History

Install the Cisco SNS 3415 and Cisco SNS 3495 Hardware Appliances, page 1

291-MB333-04P7F EN1070K

Cisco HyperFlex HX220c Edge M5

Cisco MCS 7835-H2 Unified Communications Manager Appliance

(Hardware and case keys are provided inside the chassis storage compartment.)

GS-SR104 Rack Mount Server System Installation Guide

Dell PowerEdge R430. Owner's Manual. Regulatory Model: E28S Series Regulatory Type: E28S001

64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

Oracle <Insert Picture Here>

1 Getting Started Installing & Configuring

EVO-TP Hardware System

XenData SXL- 4200N Archive System: Getting Started & Library Operation Basics. Document last updated: November 30, 2017.

ZOTAC ZBOX. User s Manual

HP ProLiant DL165 G7 Server

Dual use as a high performance server and workstation

FWA-6280A User Manual 1. FWA-6280A User Manual

Rack Installation Instructions

Cisco MCS 7828-I5 Unified Communications Manager Business Edition 5000 Appliance

Intel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide

Pioneer DreamMicro. Rackmount 1U Server - S58 Series

eslim SV Dual and Quad-Core Xeon Server Dual and Quad-Core Server Computing Leader!! ESLIM KOREA INC.

HUAWEI Tecal X6000 High-Density Server

Intel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide

Fidelis Enterprise Collector Cluster QUICK START GUIDE. Rev-I Collector Controller2 (HP DL360-G10) and Collector XA2 (HP DL360-G10) Platforms

iosafe BDR515 Hardware Guide

Transcription:

SmartVDI-110 Server Quick Start Guide Container Contents Included in container The list below shows components included in a SmartVDI-110 container. SmartVDI-110 Server Chassis mounting rails and hardware SATA DOM (for system startup) Up to four storage drives (SSD, HDD, or both) LSI SAS host bus adapter NVIDIA GRID graphics card (optional, up to two) Teradici PCoIP Offload card (optional) Fiber NIC controller (optional) Power cable(s) This Quick Start Guide Motherboard documentation SAS host bus adapter documentation If included in on server configuration, documentation for graphics card and PCoIP Offload card Not included The list below shows items not included with a SmartVDI-110 Server. Monitors Ethernet cables (copper) Fiber optic cables Keyboard and mouse Page 1 of 10 P/N G0200181 Rev A, 1.0.12.14.2015

SmartVDI-110 Overview and Features SmartVDI-110 overview The SmartVDI-110 Server is a 1U, VDI-optimized, high-performance server based on the Intel C612 chipset. The list below shows SmartVDI 110 features. Intel Xeon E5-2600 v3 series processor (up to 18 cores and 145 W) 16 DIMM slots, 288-pin DDR4 Up to 512 GB DDR 4 ECC Registered Memory 16 or 32 GB RDIMM modules 4 2.5-inch SAS/SATA hot-swap drive bays 2 10GBASE-T (GbE) Ethernet LAN ports 1 Ethernet dedicated IPMI port Support for IPMI 2.0 SmartVDI-110 front panel The picture and table below show indicators and buttons on the front panel of a SmartVDI-110. Indicator or Button Description 1 2 3 4 5 6 7 1 Overheat/ Fan Fail Solid: overheat condition. Flashing: fan failure. To troubleshoot, ensure that cables do not obstruct air flow, ambient room temperature is appropriate, and all fans are installed and operating. Also ensure that the chassis cover, all airflow shrouds, and all heat sinks are installed properly. 2 NIC 2 Flashing: network activity. 3 NIC 1 Flashing: network activity. 4 HDD Flashing: hard disk drive activity. 5 Power (Indicator) Solid: power is supplied to the server. 6 Reset Press to restart the server. 7 Power (Button) Press to power on and power off the server. Continued on next page Page 2 of 10 P/N G0200181 Rev A, 1.0.12.14.2015

SmartVDI-110 Overview and Features, Continued SmartVDI-110 rear ports and connectors The picture below shows ports, connectors, and buttons on the rear of a SmartVDI-110. PCoIP Offload Card (Optional) LSI Host Bust Adapter 17 18 8 9 10 11 12 19 Server I/O 16 10GBASE-T Fiber NIC (Optional) 13 14 15 Description Server I/0 Connectors 8 Power connector 9 Power connector 10 Dedicated IPMI LAN port 11 USB 1 port 12 USB 0 port 13 LAN 1 port 14 LAN 0 port 15 VGA port 16 Unit ID Button (press to illuminate LED for visual identification in rack) I/O Cards 17 PCoIP offload card (optional) 18 LSI Host bus adapter 19 10GBASE-T (10 GbE) fiber NIC (optional) Page 3 of 10 P/N G0200181 Rev A, 1.0.12.14.2015

Rack Rails and Mounting Rack rail components Two rack rail assemblies are included with a SmartVDI-110 Server. Each assembly has two sections: Inner rails: attach to the workstation chassis (the inner rail is pre-attached), and Outer rack rails: attach to rack The picture below shows the inner chassis rails and the outer rack rails. Inner Rail Pre-Assembled Inner Rail Extension Attach to Chassis Rear Bracket Front Bracket Outer Rack Rails Slide Front into Rear & Attach Front and Rear Brackets to Rack Continued on next page Page 4 of 10 P/N G0200181 Rev A, 1.0.12.14.2015

Rack Rails and Mounting, Continued Install inner rail extensions The picture and table below show how to attach and secure the inner rail extensions. 1 3 2 3 1 Align the hooks on the side of the chassis with the slots on the inner rail extension. 2 Slide the extension rail toward the front of the chassis. 3 Secure the extension rail with the screws provided. 4 Repeat these steps to attach the other extension rail on the other side of the chassis. Next step: assemble outer rack rails. Assemble outer rack rails Outer rack rails consist of two sections: a longer front section and a shorter rear section. Slide these together to assemble the rail. 1 Identify the left and right outer rack rails by examining the ends (brackets). These brackets bend outward as shown in Rack rail components. 2 Slide the front section of the outer rack rail into the rear outer rack rail as shown in Rack rail components. 3 Repeat these steps to assemble the other outer rack rail. Next step: install outer rack rails in a rack. Continued on next page Page 5 of 10 P/N G0200181 Rev A, 1.0.12.14.2015

Rack Rails and Mounting, Continued Install outer rack rails The picture and table below shows how to install the assembled outer rack rails in a rack. A B 1 Adjust the outer rack rails so that the outer rails fit snugly in the rack. 2 Align the holes on the front of the outer rail with the holes on the front of the rack and secure with the screws provided (see A in the adjacent picture). 3 Align the holes on the rear of the outer rack rail with the holes on the rack and secure with the screws provided (see B in the adjacent picture). 4 Repeat these steps with the other outer rack rail assembly. Next step: Install the workstation in a rack. Installing in rack To install a SmartVDI-110 Server in a rack: 1. While carefully lifting the workstation, slide the inner rail extensions into the front of the outer rack rails. 2. Push the workstation into the rack until it clicks into the locked position. Removing from rack This picture and table below show how to remove a SmartVDI-110 Server from a rack. 1. Press the outer rack rail latch to release the workstation chassis (the latch is shown in the adjacent picture). 2. Carefully slide the chassis forward off of the outer rack rails and out of the rack. Page 6 of 10 P/N G0200181 Rev A, 1.0.12.14.2015

Setting up a SmartVDI-110 Server Cabling This section shows how to connect cables. Numbers in parentheses correspond to labels shown in SmartVDI-110 front panel and in SmartVDI-110 rear ports and connectors to ease identification. 1 Install the included mounting rails to the server chassis and then install the chassis in a rack. 2 Connect one or more Ethernet cables to the LAN ports (13) and (14) on the rear of the chassis and connect the other end of the cable(s) to a network router or switch. 3 Connect one or more Ethernet cables to the Dedicated IPMI port (10) on the rear of the chassis and connect the other end of the cable to a network router or switch. 4 From the rear of the chassis, connect the included power cables to the power connectors (8 and 9) on the rear of the server, and connect the power cable to a power outlet. 5 From the front of the chassis, press the power button (7) to power on the server. Power option Press the power button (7) on the front of the chassis to power on and power off a workstation. Standby power is present when a workstation is powered off. Page 7 of 10 P/N G0200181 Rev A, 1.0.12.14.2015

Important BIOS Settings About BIOS settings Some SmartVDI-110 Server hardware configurations require specific BIOS settings. The sections below show how to access the BIOS, how to configure the BIOS for an IPMI controller, and how to configure the BIOS for NVIDIA GRID graphics cards. Accessing the BIOS The table below shows how to access the SmartVDI-110 Server BIOS. 1 Connect a keyboard and VGA monitor to the server. 2 Power on the server or reset server power. 3 Watch the server splash screen for prompts. When prompted, press the DELETE key to enter the BIOS setup utility. You can now use the arrow keys on the keyboard to navigate the BIOS menus. IPMI configuration SmartVDI-110 Servers include an IPMI 2.0 + KVM (keyboard, video and mouse) management controller. This IPMI controller uses a dedicated IP address, and the default setting is for a DHCPassigned network address. ClearCube recommends giving the controller a static IP address. You can easily change this setting from the BIOS. 1 Access the BIOS as shown above in Accessing the BIOS. 2 Use the keyboard arrow keys to select the IPMI menu. 3 Select BMC Network Configuration. Press ENTER. 4 Select Update IPMI LAN Configuration, and press ENTER. Select Yes, and then press ENTER. 5 Select Configuration Source and press ENTER. 6 Select Static and press ENTER. 7 Use the keyboard to configure the Station IP Address, Subnet Mask, and Gateway IP addresses as appropriate for your environment. Select each item and press ENTER to activate the text entry field. Enter an IP address for each item and press ENTER to set the address. 8 If your server configuration includes one or more NVIDIA GRID graphics cards, continue to the next section. Otherwise, press the F4 key to save your changes and exit the BIOS. See the note below about accessing IPMI utilities. Next steps: After saving your changes you can use a Java -enabled browser or the Supermicro IPMI tool to access the server s IPMI utilities. The default user name is ADMIN and the default password is ADMIN (both values are case-sensitive.) Continued on next page Page 8 of 10 P/N G0200181 Rev A, 1.0.12.14.2015

Important BIOS Settings, Continued NVIDIA GPU configuration If your server includes one or more optional NVIDIA GRID graphics cards, set the graphics card memory access point below the system s first 4 GB of physical memory. Specify this setting in the BIOS to guarantee the memory configuration. The steps below show how to change the BIOS setting. 1 Access the BIOS as shown above in Accessing the BIOS. 2 Use the keyboard arrow keys to select the Advanced menu. 3 Select the Above 4G Decoding option. Press ENTER. 4 Select Disable and press ENTER. 5 Press the F4 key to save your changes and exit the BIOS. Page 9 of 10 P/N G0200181 Rev A, 1.0.12.14.2015

Related Information and Support Related information The table below shows additional documents about server configuration, operation, and maintenance. For information about Deployment guidelines for SmartVDI servers NVIDIA GRID graphics card configuration Installation services See SmartVDI Converged Infrastructure Platform Deployment Guide GPU Quick Install Guide included with the SmartVDI server Contact ClearCube or your Authorized ClearCube Reseller. ClearCube documentation is located at http://www.clearcube.com/support/. Contacting Support Web Uwww.clearcube.com/support/ Email Usupport@clearcube.com Toll-free (866) 652-3400 Direct (512) 652-3400 WEEE Disposal Guidelines In the European Union, this electronic product falls under the European Directive (2002/96/EC) WEEE. When it reaches the end of its useful life or is no longer wanted, it should not be discarded with conventional waste, but disposed of at an approved designated recycling and/or treatment facility. Laws are different in each country, so please check with your local authorities for proper disposal instructions. For assistance, contact ClearCube at recycle@clearcube.com. Page 10 of 10 P/N G0200181 Rev A, 1.0.12.14.2015