Voltage Dip-Proofing Inverter

Similar documents
Voltage Dip-Proofing Inverter

Voltage Sag Simulator

Voltage-Dip Proofing Inverters

Earth Continuity Monitor

MC 11 EB-2 Power supply cabinet with external bus, AC version

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

Table of Contents. Safety. Attention. Warnings

PACSystems RX3i IC695PSA140

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

MINI-PS AC/10-15DC/8

VS-P Series. TDK-Lambda INSTRUCTION MANUAL

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

Power supply CP-C 24/5.0

SMARTONLINE E3 UPS SYSTEMS

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

QUINT-BUFFER/24DC/24DC/40

ASCO 920 Remote Control (RC) Switches

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

Model 7705 Control Module

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Safety Standards. Model Number:

920 Remote Control (RC) Switches

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

Model Number Structure

PHOENIX CONTACT - 01/2007

Model Number Structure

CliQ DIN Rail Power Supply 24V 60W 1 Phase / DRP024V060W1AZ

Safety Standards. Model Number:

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

QUINT-PS/ 1AC/24DC/ 5

Power Supplies V7-T6-2 V7-T6-4 V7-T6-10 V7-T6-16 V7-T6-36 V7-T6-39 V7-T6-43

PMT. PMT Panel Mount Power Supply 5V 50W 1 Phase / PMT-5V50W1A. Highlights & Features. Safety Standards. Model Number: General Description

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

SNO 4062K SNO 4062KM SNO 4062 K / KM. Circuit diagram. Applications. Function. Function (Continued)

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

PMT. Safety Standards. Model Number:

Voltage Current Front-mounting bracket

Safe monitoring relays

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

GSP750 Series. 750 Watts. AC-DC Power Supplies. Models & Ratings. Input

RTU500 series Data Sheet Power Supply CP-E 24/2.5

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

BUFFER MODULE SHORT-FORM DATA MARKINGS

Overview Included in the Box: Pinout Installation Power Supply Stepping Motors DIP Switch (JP1) Location...

SLI 15 INVERTER SERIES, 1500 W

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

PMT. Safety Standards. Model Number:

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

QUINT-PS/ 1AC/24DC/20/CO

Redundancy unit CP-A RU

PHOENIX CONTACT Features

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

2T105. Multi Range Digital Setting Time Delay Relay. Features. Application. Operation

TPE 1464 Series Pressure Transducer

Uninterruptible Power Supplies

PMC. PMC Panel Mount Power Supply 24V 50W 1 Phase / PMC-24V050W1A. Highlights & Features. Safety Standards. Model Number: General Description

CUS150M1 Instruction Manual

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-D2V100W1A. V1: 3.50A (Selectable by Switch) V2: 5Vdc

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-24V100W1AX Vac ( Vdc) 24Vdc 4.17A

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Contact protection relay

DC Outdoor Power Supply/Chargers

Model Number: Model Number Input Voltage Range Rated Output Voltage Rated Output Current PMT-24V100W2AA Vac 24Vdc 4.50A

Safety Standards. Model Number:

Power supply CP-E 24/10.0 Primary switch mode power supply

PHOENIX CONTACT - 07/2006

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

60103 Circuit Breaker

FL MC 2000E (SM40) LC

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

RT4B-110V/12A RECTIFIER

Power supply CP-E 48/1.25 Primary switch mode power supply

PGR-3200 MANUAL INSULATION MONITOR

RT4F-110V/25A RECTIFIER

PG Softstarter Installation Manual for 5A, 9A and 16A Controllers

Level-Lance Model 5400A

PMC. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-12V060W1NA Vac ( Vdc) 12Vdc 5.

APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out

SE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

PMT. Safety Standards. Model Number:

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Power supply CP-E 24/0.75 Primary switch mode power supply

High Power Electronic Gear Installation and operation Guide

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

Suitable for detecting transparent films or transparent bottles

Transcription:

Voltage Dip-Proofing Inverter DPI54S / 54L Series Models 120V & 208/230 50/60Hz

Contents: Introduction...3 Theory of operation...3 Specifications...5 Up-time considerations...6 Installation Guide...7 Test and Maintenance...9 Mechanical Outline...11 Accessories...14 Notice: IMPORTANT SAFETY INSTRUCTIONS! KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE This manual contains important instructions that should be followed during installation and adjustment of all DPI54 Series Voltage Dip-Proofing Inverters. Page 2 DPI54 Series Firmware Ver 1.0

1. Introduction The reliability of electrical power to industry is in general very high, nevertheless, voltage sags and short power interruptions or voltage dips occur. These instabilities are caused by short circuits, lightning strikes on overhead power lines and heavy load switching. The duration of such faults is generally shorter than one second. Most plant can ride through such voltage dips by virtue of their mechanical and electrical inertia. However, this is not the case with electrically held-in contactors and relays that control the machinery. Contactors typically drop out from 5ms to 20ms after power is removed. Each short voltage dip now becomes a power failure and the plant must be restarted. This can be complicated, time-consuming and costly. DIP-PROOFING TECHNOLOGIES VOLTAGE DIP- PROOFING INVERTERS are designed to maintain the switchgear control voltage during voltage dips, effectively keeping the plant connected. The stored electrical and magnetic energy is allowed to flow, supporting the mechanical inertia of the machinery. When the power is restored after a short voltage dip, the plant is still running at near synchronous speed, the inrush currents will be small and the stress to the system minimal. Historically, this problem has been addressed by using DC contactors, latched contactors and intelligent controls such as PLC s. These systems are complex and expensive and do not provide a solution for equipment already in existence. The current approach to this problem has been to employ intelligent control systems which provide a curative solution. In contrast, the Voltage-Dip Proofing Inverter, provides a preventative solution. 2. Theory of operation The VOLTAGE-DIP PROOFING INVERTER is designed to be maintenance free and highly reliable. It consists of a static switch in series with, and an inverter parallel to, the load. Energy is stored in a capacitor bank : the inverter block diagram is shown in Fig 1. Static Switch Supply Storage Capacitor Inverter Load Fig 1 Inverter Block Diagram Page 3

The STATIC SWITCH is robust and can withstand large current surges. It is ideally suited for contactor operation where high peak currents of short duration occur during energizing. The INVERTER is configured as a full bridge with overcurrent and short circuit protection. The output waveform is a square wave where the RMS and the peak voltage are the same as for a sine wave as shown in Fig 2. V t Fig 2 Inverter stepped square wave output waveform This is important for circuits where magnetic devices, such as transformers and contactors (RMS voltage) are in circuit with electronic relays that derive their DC voltage from capacitor input filters (peak voltage). The computer grade CAPACITOR BANK operates under ideal conditions, being charged to working voltage but carrying no ripple current most of the time. During stand-by operation, the static switch supplies power directly to the load, the inverter is switched off and the capacitors are charged to the full operating voltage. The supply voltage is constantly monitored for deviations; should there be a deviation from Vnom which is greater than the preset value, the static switch is switched off and the inverter is activated. The switch-over is accomplished in less than 200µs. A 3.15 second timer, adjustable in increments of 50ms, starts timing the inverter out. Should the input voltage recover within the set time, the inverter supply is synchronized to the mains and the load is switched back to the supply, the capacitors are recharged in less than one second and the inverter is ready to compensate for the next voltage dip. If the input voltage does not recover within the set time the load is switched back to the supply regardless of the voltage level. Page 4

Specifications DPI 54S / 54L Series 120V Models AC INPUT SUPPLY Single phase supply voltage Maximum input voltage Full load current (A) STATIC SWITCH Nominal off-state voltage Peak off-state voltage Nominal current (A) Short time overload current (<100ms) Non-repetitive peak on-state current (10ms) INVERTER Nominal output voltage Voltage fluctuations over full operating range Nominal load current (A) Overload Current (A) Power factor range Wave shape Nominal load (VA) Storage capacitors (F) Usable stored energy factor ( ) Minimum up-time as function of the load Output frequency Max recovery time of capacitors to 95%Vin SETTINGS Timer Range and Setting Transfer Level Range and Setting INDICATORS System OK Inverter running TEMPERATURE Maximum ambient working temperature CUBICLE Construction Height (L3) (mm) Height (L3) (in) Width (mm) Depth (mm) Mass (kg) Mass (lbs) CONNECTION Cable, Copper panel wire Screw terminal torque LISTING DPI54S6.6mF120V6A DPI54S13.2mF120V6A 6A DPI54S19.8mF120V6A 6A 30A 170A 6A 15A DPI54S39.6mF120V8A 8A 8A 8A Installation & Service Manual DPI54L33mF120V25A DPI54L66mF120V25A DPI54L99mF120V25A DPI54L198mF120V25A. 120V 50/60Hz +10% 25A 150Vac RMS 800V 25A 60A 700A 120Vac RMS ±10% 25A 30A cos from 1 to 0 Stepped square 3000 DPI54L297mF120V25A DPI54L396mF120V25A DPI54L495mF120V25A DPI54L594mF120V25A DPI54L693mF120V25A 720 960.0066.0132.0198.0396.033.066.099.198.297.396.495.594.693 0.47 t = ( *C cap *V supply ) / (I load *cos ) 50/60Hz ±1% 0.5s 1.1s 1.6s 2.4s 0.6s 1.2s 1.8s 0.05-3.15s in 0.05s steps 90% to 65% of calibrated supply voltage V cal in 5% steps green LED red LED 45 C (113 F) Extruded Aluminum 219 254 362 284 284 284 409 500 591 682 773 864 8.62 10.00 14.25 11.18 11.18 11.18 16.10 19.69 23.27 26.85 30.43 34.02 150 (5.90) 110 (4.33) 350(13.78) 231(9.09) 2.2 2.5 2.7 4.4 8.7 10 11.5 19 25 31 37 43 49 4. 8 5. 4 5.9 9.6 19.1 22 25.3 41.8 55 68.2 81.4 94.6 108 1mm 2 (17AWG) 6mm 2 (10AWG) 1.76 Nm (15.6 lb-in) Page 5

Specifications DPI 54S / 54L Series 208 / 230V Models AC INPUT SUPPLY Single phase supply voltage Maximum input voltage Full load current (A) STATIC SWITCH Nominal off-state voltage Peak off-state voltage Nominal current (A) Short time overload current (<100ms) Non-repetitive peak on-state current (10ms) INVERTER Nominal output voltage Voltage fluctuations over full operating range Nominal load current (A) Overload current (A) Power factor range Wave shape Nominal load (VA) Storage capacitors (F) Usable stored energy factor ( ) Minimum up-time as function of the load Output frequency Max recovery time of capacitors to 95%Vin SETTINGS Timer Range and Setting Transfer Level Range and Setting INDICATORS System OK Inverter running TEMPERATURE Maximum ambient working temperature CUBICLE Construction Height (L3) (mm) Height (L3) (in) Width (mm) Depth (mm) Mass (kg) Mass (lbs) CONNECTION Cable, Copper panel wire Screw terminal torque LISTINGS DPI54S2.04mF230V6A DPI54S4.08mF230V6A 6A DPI54S6.12mF230V6A 6A 30A 170A 6A 15A DPI54S12.24mF230V8A 8A 8A DPI54L15mF230V25A DPI54L30mF230V25A DPI54L45mF230V25A DPI54L90mF230V25A. 230V 50/60Hz +10% 25A 250Vac RMS 800V 25A 60A 700A 230Vac RMS ±10% 25A 30A cos from 1 to 0 Stepped square 5750 DPI54L135mF230V25A DPI54L180mF230V25A DPI54L225mF230V25A DPI54L270mF230V25A 1380 1840.00204.00408.00612.01224.015.030.045.090.135.180.225.270.315 0.53 0.55 t = ( *C cap *V supply ) / (I load *cos ) 50/60Hz ±1% 0.7s 1.4s 2.0s 3.0s 1.0s 2.1s 3.2s 8.0s 8.0s 0.05-3.15s in 0.05s steps 90% to 65% of calibrated supply voltage V cal in 5% steps green LED red LED 45 C (113 F) DPI54L315mF230V25A Extruded Aluminum 219 254 362 284 284 284 409 500 591 682 773 864 8.62 10.00 14.25 11.18 11.18 11.18 16.10 19.69 23.27 26.85 30.43 34.02 150 (5.90) 110 (4.33) 350 (13.78) 231 (9.09) 2.2 2.5 2.7 4.4 8.7 10 11.5 19 25 31 37 43 49 4.8 5.4 5.9 9.6 19.1 22 25.3 41.8 55 68.2 81.4 94.6 108 1mm 2 (17AWG) 8A 6mm 2 (10AWG) 1.76 Nm (15.6 lb-in) Page 6

Up-time considerations The up-time that a DPI can achieve is dependent on the usable energy in the storage capacitors and on the characteristics of the supported load. Load characteristics are critical in determining the up-time. Resistive loads with a power factor near 1 consume real power and the up-time will be shortest. Resistive loads include lamps, switch mode power supplies and linear power supplies. Contactors use little real power as they are a reactive load with power factors around 0.15. Reactive loads such as contactors give the longest up-time. The formulae below can be used to determine the minimum up-time that can be achieved for an application. It uses the load current, load voltage, load power factor, the value of the DPI storage capacitors and a stored energy factor to calculate the value. Minimum up-time as function of the load: t = ( *C cap *V supply ) (I load*cos ) Minimum up-time = t Value of storage capacitor(s) = C cap Stored energy factor = Load voltage = V supply Load current = I load Load power factor = cos From the formulae it can be seen that the power factor (cos ) has a significant influence on the up-time. Resistive loads with cos = 1 will yield the shortest up-time while reactive loads with cos = 0.15 will yield the longest up-time. For example: A. Using DPI model DPI54L15mF230V25A find the minimum up-time for a predominantly resistive load; say a PLC power supply and some small relays. Value of storage capacitor(s) = 0.015F Stored energy factor = 0.55 Load voltage = 230V Load current = 6A Load power factor = 0.8 Minimum up-time t = (0.55*0.015*230) (6.0*0.8) = 0.39 seconds. B. Using DPI model DPI54L15mF230V25A find the minimum up-time for a predominantly reactive load; say some small contactors and relays. Value of storage capacitor(s) = 0.015F Stored energy factor = 0.55 Load voltage = 230V Load current = 6.0A Load power factor = 0.15 Minimum up-time t = (0.55*0.015*230) (6.0*0.15) = 2.1 seconds. The examples illustrate the importance of knowing the load power factor when calculating the minimum up-time for a DPI application. For best accuracy use the on line DPI Selector to find the correct size DPI for an application. Link: http://www.dipproof.com/products/dpi_selector.asp Page 7

Installation Guide 1. Remove the unit from its packing 2. Place the unit horizontally on a bench and visually check for any mechanical damage. Ensure that all the casing screws are tight then shake the unit to check that there is nothing loose internally. 3. Check that the inverter voltage is the same as the system control voltage. Refer to the rating label on the unit end plate. WARNING:Never connect a 120V unit to a 230V supply! 4. Decide on the location where the unit is to be installed, this will probably be inside a switch gear panel. 5. Mount the unit vertically using M6 bolts. 6. Connect unit as shown in Fig 3 using 1mm 2 (17AWG) DPI54S Series & 6mm 2 (10AWG), DPI54L Series copper panel wire. 7. Apply terminal screw tightening torque of 1.5-1.8Nm (13-16 lb-in). 8. This device does not have a disconnect switch. If such a switch is required it must be provided by others. Power Wiring Connections Line In (Supply) to Terminal 1 Common Line In to Terminal 2 Common Line Out to Terminal 3 Line Out (Load) to Terminal 4 Ground screws to be connected on the unit to the panel ground point. 1 2* 3* 4 Ground In Line In (Supply) Common Line In Common Line Out Line Out (Load) Ground Out * Note: Terminals 2 and 3 are linked internally Fig 3 Power Wiring Diagram Page 8

9. Once the unit has been mounted and the external wiring completed, power can be applied.turn on the power to the unit. After about two seconds the green LED indicator "System OK" should come on. The unit is now fully operational. 10. In applications which require no break maintenance, a bypass switch must be installed. Order Housed Bypass Switch model DPIBPSW which should be connected as shown in Fig 4. DPI Ground 1 2 3 4 Ground To DPI1 or VDC Line In Line In To Supply 1 2 3 4 In Out Common Line DPI Common Line In Out 2 3 4 Bypass Line Out Line Out Line In (Supply Vnom) Common Line In Functional Description Indicators Line Out (Load) Common Line Out Fig 4 Housed Bypass Switch Connection Diagram System OK : Green LED indicator. When the green LED is ON the system is fully functional; the unit self- test and initialization routine has run successfully. Inverter Running : Red LED indicator. The red LED is on when the inverter is running during a voltage dip. A stepped square wave is present on the output terminals 3 and 4. Page 9

Test and Maintenance There are no user serviceable parts inside the unit, if faulty return to factory or local agent for repairs. WARNING: Risk of electric shock, capacitor(s) store hazardous energy. NEVER attempt any maintenance on the DPI until storage capacitors are fully discharged. Dangerously high voltages can be present up to 2 hours after the DPI has been disconnected unless the storage capacitors have been manually discharged. Adjustments All adjustment points are marked on the top cover plate and can be reached by removing the two screws securing the main label. INVERTER RUN TIME - DSW1 This switch sets the running time of the inverter and can be set in 50ms steps to a maximum of 3,15 seconds. To determine the inverter run time which is currently set, add the figures printed next to each switch which is in the ON position. For example, a running time setting of one second requires that the following switches be in the ON position:- 200 + 800 : these figures added give 1000ms or 1s. Factory Setting : 1000ms CALIBRATION TO A SUPPLY VOLTAGE - SW1 - Cal The unit can be calibrated for a different supply voltage, for example a 230V unit used on a 208V supply. The Calibrate button (Cal) is used to program the unit to operate on a specific supply voltage. WARNING: Never connect a 120V unit to a 230V supply! Refer to the unit rating label before connecting the supply. Connect the unit to the supply and switch on. Press the Calibrate button (Cal). The System OK (green) LED will switch off for approximately 3 seconds and then switch back on. The unit is now calibrated for the supply voltage to which it is connected. Factory Setting : Calibrated to rating label Vnom ADJUSTMENTS - DSW2 TYPE 1 Standard 0 Two level 1 Noise immune 0 Noise immune and Two level 0 Factory setting: Noise immune SWITCHES 2 3 0 0 0 0 1 0 0 1 4 0 0 0 0 DESCRIPTION 250 sec. detection time >30% of non-voltage fixed run time of 200msec 1msec detection time both of the above TRANSFER LEVEL - DSW3 Sets the supply voltage level at which the inverter switches to run mode. The level can be varied between 65% and 90% of the nominal supply voltage by setting the switches according to the table in Fig.5. Factory setting : 75% Page 10

Set Transfer Level: LED2 GREEN SYSTEM OK 90% 85% 80% 75% 70% 65% Off On Off On Set Inverter DSW3 DSW1 Run Time: 0.05 sec 0.1 sec 0.2 sec SW1 0.4 sec 0.8 sec 1.6 sec Press to Calibrate LED1 RED INVERTER RUNNING 1 2 3 4 DSW2 ON Fig 5 Control Card Indicator and Adjustment Locations Diagnostics 1. Supply Voltage Out of Range If the unit supply voltage is permanently outside the +/- 10% range of the supply voltage to which the unit is calibrated (Vcal) the unit will not power up and there will be no LED indicators on. Recalibration to the new supply voltage is necessary. Diagnostic relay outputs 2. Unit faulty, relay contact opens (T6 - T7) if: - There is no power on input (T1 - T2) - If, at power up, the supply voltage does not exceed the set transfer level - Unit control power supply is faulty - Microcontroller faulty - Microcontroller watchdog activated; program execution problem - Inverter fuse blown - No voltage on storage capacitors - Unit has no output voltage (T3 & T4) Event detection relay contact changes state (T8 - T10) when: - The inverter runs to support an event. Note: The options for diagnostic and event detection outputs should be specified when ordering. They are also available as a retrofit kit. Due to space restrictions, the DPI54S Series supports the diagnostic option only. Page 11

Mechanical Construction 54S Series - The DPI case is made from extruded aluminium sections. The four parts that make up the case are interlocked and secured by screws. To remove the front cover, unscrew four screws: the two top screws from the end plate where the terminal block is located and the two bottom screws from the other end plate. Slide the front cover away from the terminal block. Note that there are no user serviceable parts inside the unit. All adjustment points are marked on the top cover plate and can be reached by removing the two screws securing the main label. 54L Series - The DPI case is made from extruded aluminium sections. The six parts that make up the case are interlocked and secured by screws. To remove the front cover, unscrew five screws: one from the front cover and two each from the top and bottom end plates. Units are supplied with four or six mounting brackets depending on the case length. The bracket positions are adjustable along the length of the case (Dim. L1 and L6). Note that there are no user serviceable parts inside the unit. All adjustment points are marked on the top cover plate and can be reached by removing the two screws securing the main label. Dimension Table MODEL DPI54S6.6mF120V6A DPI54S13.2mF120V6A DPI54S19.8mF120V6A DPI5S39.6mF120V8A L1 0 (0) 0 (0) 0 (0) 160 (6.29) L2 L3 170 (6.69) 219 (8.62) 170 (6.69) 219 (8.62) 205 (8.07) 254 (10.0) 313 (12.32) 362 (14.25) DPI54 SERIES DIMENSIONS mm (inches) L4 L5 L6 L7 85 (3.35) 110 (4.33) 150 (5.90) 85 (3.35) 102.5(4.04) 75 (3.00) 140 (5.50) D 6.0 (0.24) DPI54L33mF120V25A DPI54L66mF120V25A DPI54L99mF120V25A DPI54L198mF120V25A DPI54L297mF120V25A DPI54L396mF120V25A DPI54L495mF120V25A DPI54L594mF120V25A DPI54L693mF120V25A 115 (4.53) 240 (9.45) 331 (13.03) 422 (16.61) 513 (20.20)* 604 (23.78)* 695 (27.36)* 235 (9.25) 360 (14.17) 451 (17.76) 542 (21.33) 633 (24.92) 724 (28.50) 815 (32.08) 284 (11.18) 409 (16.10) 500 (19.69) 591 (23.27) 682 (26.85) 773 (30.43) 864 (34.02) 231 (9.09) 350 (13.78) 60 (2.36) 330.5(13.0) 8.0 (0.31) DPI54S2.04mF230V6A DPI54S4.08mF230V6A DPI54S6.12mF230V6A DPI54S12.24mF2308A 0 (0) 0 (0) 0 (0) 160 (6.29) 170 (6.69) 219 (8.62) 170 (6.69) 219 (8.62) 205 (8.07) 254 (10.0) 313 (12.32) 362 (14.25) 110 (4.33) 150 (5.90) 85 (3.35) 85 (3.35) 102.5(4.04) 75 (3.00) 140 (5.50) 6.0 (0.24) DPI54L15mF230V25A DPI54L30mF230V25A 115 (4.53) 235 (9.25) 284 (11.18) DPI54L45mF230V25A DPI54L90mF230V25A 240 (9.45) 360 (14.17) 409 (16.10) DPI54L135mF230V25A 331 (13.03) 451 (17.76) 500 (19.69) 231 (9.09) 350 (13.78) DPI54L180mF230V25A 422 (16.61) 724 (28.50) 591 (23.27) DPI54L225mF230V25A 513 (20.20)* 815 (32.08) 682 (26.85) DPI54L270mF230V25A 604 (23.78)* 773 (30.43) DPI54L315mF230V25A 695 (27.36)* 864 (34.02) * Indicates 6 mounting brackets; dimension L1* = L1/2 60 (2.36) 330.5(13.0) 8.0 (0.31) Page 12

Mechanical Outline L7 L7 S Series Case Model example: DPI54S6.12mF230V6A Terminal Cover L4 L6 ød L1* ød L Series Case Model example: DPI54L L1 L2 L3 L1 L2 L3 Terminal Cover Ground Screws 1 2 3 4 L4 L6 L5 L5 Note: Terminal cover shown dashed. Mounting bracket spacing is adjustable. Some longer units are supplied with 6. Terminal Block for 54L Series Options Terminal Block for 54S Series Options 1 2 3 4 5 6 7 8 1 2 3 4 5 Terminal 1 Line In (Supply) Terminal 2 Common line in Terminal 3 Common line out Terminal 4 Line out (Load) Terminal 5 Unit Faulty n/o Terminal 6 Unit Faulty n/o Terminal 7 Event detection n/o Terminal 8 Event detection n/o Terminal 1 Line In (Supply) Terminal 2 Common line in / out Terminal 3 Line out (Load) Terminal 4 Unit Faulty n/o Terminal 5 Unit Faulty n/o Page 13

This page left blank intentionally. Page 14

Accessories Housed Bypass Switch Description: Where no-break maintenance is required, a bypass switch must be installed. It connects the supply directly to the load, Bypass position, and disconnects the power terminals of the inverter without interrupting the supply. When in DPI position, the load is connected to the supply via the inverter. SPECIFICATIONS Model ELECTRICAL Maximum current Maximum Input Voltage TEMPERATURE Maximum Working Temperature HOUSING Construction Height Width Depth Mass BPSW25A 25A 600V AC 45 C (113 F) Extruded Aluminium 202mm (7,95in) 150mm (5,9in) 141mm (5,55in) 1kg (2.2lbs) Mechanical Outline Mounting holes 2 x 6 (0.25) ø 31 (1.22) 41.0 (1.61) Ground Screws 1 2 3 4 110 (4.33) To DPI or VDC Line In Line In To Supply 1 1 2 3 4 In Out Common Line DPI Common Line In Out 2 3 4 Bypass Line Out Line Out 50 (1.97) 50 (1.97) 120 (4.72) 140 (5.51) 41.0 (1.61) 150 (5.90) Dimensions in mm (inches) Ordering Stock No: 5003-006 Housed By-Pass Switch 25A Page 15

Voltage Dip-Proofing Inverter DPI54S / 54L Series Models 120V & 208/230 50/60Hz Motor Control Centre B1 B2 B3 1 Static Switch 4 Stop Stop Stop Storage Capacitor Bridge Inverter Main Breaker 2 3 Start Start Start Line Voltage Control Voltage Bypass Switch Inter- Lock Inter- Lock Inter- Lock C1 C2 C3 A Typical DPI Connection Diagram Measurlogic Inc. 7334 S. Alton Way, Suite 14M Centennial, CO 80134, USA Tel:1-877-777-6567 Fax:425-799-4780 Email: info@measurlogic.com web: www.measurlogic.com V1.01-21032015