Trajectory-based Deformation Correction in Ultrasound Images

Similar documents
A fast breast nonlinear elastography reconstruction technique using the Veronda-Westman model

A Robust Meshing and Calibration Approach for Sensorless Freehand 3D Ultrasound

Towards an Estimation of Acoustic Impedance from Multiple Ultrasound Images

Material Properties Estimation of Layered Soft Tissue Based on MR Observation and Iterative FE Simulation

Finite Element Simulation of Moving Targets in Radio Therapy

3-D Compounding of B-Scan Ultrasound Images

Out-of-plane motion estimation based on a Rician-Inverse Gaussian model of RF ultrasound signals: speckle tracking without fully developed speckle

Guidelines for proper use of Plate elements

A Non-Linear Image Registration Scheme for Real-Time Liver Ultrasound Tracking using Normalized Gradient Fields

SIMULATING ARBITRARY-GEOMETRY ULTRASOUND TRANSDUCERS USING TRIANGLES

Tracked Ultrasound Elastography (TrUE)

Advanced Image Reconstruction Methods for Photoacoustic Tomography

MEDICAL IMAGE NOISE REDUCTION AND REGION CONTRAST ENHANCEMENT USING PARTIAL DIFFERENTIAL EQUATIONS

Whole Body MRI Intensity Standardization

A Study of Medical Image Analysis System

Adaptive Multiscale Ultrasound Compounding Using Phase Information

Paper Presentation 03/04/2010

Modelling Flat Spring Performance Using FEA

Application of a FEA Model for Conformability Calculation of Tip Seal in Compressor

Validation of aspects of BeamTool

Novel Reconstruction and Feature Exploitation Techniques for Sensorless Freehand 3D Ultrasound

Robust Segmentation and Volumetric Registration in

Evaluation of Fourier Transform Coefficients for The Diagnosis of Rheumatoid Arthritis From Diffuse Optical Tomography Images

Non-Linear Finite Element Methods in Solid Mechanics Attilio Frangi, Politecnico di Milano, February 3, 2017, Lesson 1

University of Cambridge Department of Engineering Trumpington Street Cambridge CB2 1PZ United Kingdom.

STATISTICAL ANALYSIS OF A THREE-DIMENSIONAL AXIAL STRAIN AND AXIAL-SHEAR STRAIN ELASTOGRAPHY ALGORITHM. A Thesis MOHAN LI

Quantifying Three-Dimensional Deformations of Migrating Fibroblasts

Development and validation of a short-lag spatial coherence theory for photoacoustic imaging

Intraoperative Prostate Tracking with Slice-to-Volume Registration in MR

University of Cambridge Department of Engineering Trumpington Street Cambridge CB2 1PZ United Kingdom.

Predicting Tumour Location by Modelling the Deformation of the Breast using Nonlinear Elasticity

Image Thickness Correction for Navigation with 3D Intra-cardiac Ultrasound Catheter

Digital Volume Correlation for Materials Characterization

MATERIAL property estimation has been an important

[ Ω 1 ] Diagonal matrix of system 2 (updated) eigenvalues [ Φ 1 ] System 1 modal matrix [ Φ 2 ] System 2 (updated) modal matrix Φ fb

Locating ego-centers in depth for hippocampal place cells

Volumetric Analysis of the Heart from Tagged-MRI. Introduction & Background

GPU Ultrasound Simulation and Volume Reconstruction

A COMPARISON OF WAVELET-BASED AND RIDGELET- BASED TEXTURE CLASSIFICATION OF TISSUES IN COMPUTED TOMOGRAPHY

Sound-speed tomography using first-arrival transmission ultrasound for a ring array

Non-Linear Analysis of Bolted Flush End-Plate Steel Beam-to-Column Connection Nur Ashikin Latip, Redzuan Abdulla

Predicting Tumour Location by Simulating Large Deformations of the Breast using a 3D Finite Element Model and Nonlinear Elasticity

Implementing the probe beam deflection technique for acoustic sensing in photoacoustic and ultrasound imaging

Effect of Sensor Directionality on Photoacoustic Imaging: A Study Using the k-wave Toolbox

Motion artifact detection in four-dimensional computed tomography images

Finite Element Method. Chapter 7. Practical considerations in FEM modeling

DUE to beam polychromacity in CT and the energy dependence

Elastic registration of medical images using finite element meshes

CHAPTER 5 MOTION DETECTION AND ANALYSIS

Dr. Ulas Bagci

An Automated Image-based Method for Multi-Leaf Collimator Positioning Verification in Intensity Modulated Radiation Therapy

A Procedure for the 3D Reconstruction of Biological Organs from 2D Image Sequences

University of Cambridge Department of Engineering Trumpington Street Cambridge CB2 1PZ United Kingdom.

An Acquisition Geometry-Independent Calibration Tool for Industrial Computed Tomography

Elastic Bands: Connecting Path Planning and Control

연구용유방초음파질관리 원광대학병원김혜원

Speed-accuracy trade-offs in computing spatial impulse responses for simulating medical ultrasound imaging

2. LITERATURE REVIEW

The majority of medical ultrasound imaging is carried

3D Finite Element Software for Cracks. Version 3.2. Benchmarks and Validation

A Model-Independent, Multi-Image Approach to MR Inhomogeneity Correction

Application of Finite Volume Method for Structural Analysis

Time-Domain Dynamic Analysis of Helical Gears with Reduced Housing Model

Development of 3D Model-based Morphometric Method for Assessment of Human Weight-bearing Joint. Taeho Kim

Saurabh GUPTA and Prabhu RAJAGOPAL *

REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT

A Novel Image Super-resolution Reconstruction Algorithm based on Modified Sparse Representation

Lateral ultrasound strain imaging using subband processing

CHAPTER 1. Introduction


AXIAL OF OF THE. M. W. Hyer. To mitigate the. Virginia. SUMMARY. the buckling. circumference, Because of their. could.

Computational Medical Imaging Analysis Chapter 4: Image Visualization

Computational Neuroanatomy

Module 1: Introduction to Finite Element Analysis. Lecture 4: Steps in Finite Element Analysis

David Wagner, Kaan Divringi, Can Ozcan Ozen Engineering

Interpolation of 3D magnetic resonance data

Spatio-Temporal Registration of Biomedical Images by Computational Methods

Local Image Registration: An Adaptive Filtering Framework

Revision of the SolidWorks Variable Pressure Simulation Tutorial J.E. Akin, Rice University, Mechanical Engineering. Introduction

Non-Rigid Image Registration III

Proceedings of Meetings on Acoustics

Snakes operating on Gradient Vector Flow

Comparison Study of Clinical 3D MRI Brain Segmentation Evaluation

Wave Propagation Correlations between Finite Element Simulations and Tests for Enhanced Structural Health Monitoring

1. Deployment of a framework for drawing a correspondence between simple figure of merits (FOM) and quantitative imaging performance in CT.

GLUENet: Ultrasound Elastography Using Convolutional Neural Network

CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION

Ultrasonic Multi-Skip Tomography for Pipe Inspection

Combinatorial optimization and its applications in image Processing. Filip Malmberg

The use of acoustic reflectors to enlarge the effective area of planar sensor arrays

EXACT BUCKLING SOLUTION OF COMPOSITE WEB/FLANGE ASSEMBLY

Available online at ScienceDirect. Physics Procedia 63 (2015 )

DETECTION AND QUANTIFICATION OF CRACKS IN PRESSURE VESSELS USING ESPI AND FEA MODELLS

ABSTRACT 1. INTRODUCTION 2. METHODS

Generative Part Structural Analysis Fundamentals

ULTRASONIC TESTING AND FLAW CHARACTERIZATION. Alex KARPELSON Kinectrics Inc., Toronto, Canada

University of Cambridge Department of Engineering Trumpington Street Cambridge CB2 1PZ United Kingdom.

PERFORMANCE CAPTURE FROM SPARSE MULTI-VIEW VIDEO

Context based optimal shape coding

Revised Sheet Metal Simulation, J.E. Akin, Rice University

Transcription:

Trajectory-based Deformation Correction in Ultrasound Images The MIT Faculty has made this article openly available. Please share how this access benefits you. Your story matters. Citation As Published Publisher Sun, Shih-Yu, Brian W. Anthony, and Matthew W. Gilbertson. Trajectory-based deformation correction in ultrasound images. Medical Imaging 2010: Ultrasonic Imaging, Tomography, and Therapy. Ed. Jan D'hooge & Stephen A. McAleavey. San Diego, California, USA: SPIE, 2010. 76290A-9. 2010 SPIE. http://dx.doi.org/10.1117/12.844184 SPIE Version Final published version Accessed Sat Jul 21 19:29:31 EDT 2018 Citable Link Terms of Use Detailed Terms http://hdl.handle.net/1721.1/58562 Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.

Trajectory-based Deformation Correction in Ultrasound Images Shih-Yu Sun, Brian W. Anthony*, Matthew W. Gilbertson Laboratory for Manufacturing and Productivity, MIT, Cambridge, MA, 02139 ABSTRACT Tissue deformation in ultrasound imaging poses a challenge to the development of many image registration techniques, including multimodal image fusion, multi-angle compound image and freehand three-dimensional ultrasound. Although deformation correction methods are desired to provide images of uncompressed tissue structure, they have not been well-studied. A novel trajectory-based method to correct a wide range of tissue deformation in ultrasound imaging was developed. In order to characterize tissue deformation under different contact forces, a force sensor provides contact force measurement. Template based image-flow techniques were applied to RF A-lines under different contact forces. A two-dimensional displacement trajectory field was constructed, where pixel coordinates in each scan were plotted against the corresponding contact force. Nonlinear extrapolation algorithms are applied to each trajectory to relocate the corresponding pixel to where it would have been had there been no contact, thereby correcting tissue deformation in the images. This method was validated by using a combination of FEM deformation and ultrasound simulation. It was shown that deformation of the simulated pathological tissue could be corrected. Furthermore, nonlinear polynomial regression was found to give better estimates, than linear regression, when large deformation was present. Estimation accuracy was not improved significantly for a polynomial regression larger than second order. Keywords: deformation correction, 2D displacement estimation, trajectory, soft tissue modeling, hyperelastic, non-rigid registration 1. INTRODUCTION Ultrasound imaging is regularly used for diagnosis, and is usually performed in a manner where a probe makes contact with the skin. In this procedure, deformation of the underlying tissue is inevitable, and thus structures shown in imaging are actually distorted. The distortion is usually small and would not be a problem in most situations, since most of the characteristics of tissue will be retained under compression. In fact, tracking tissue deformation under probe contact provides information to discriminate between normal and pathological tissue in elastography. For applications where the undeformed appearance of biological tissue is required, however, correcting or avoiding tissue deformation becomes important. For example, in freehand three-dimensional ultrasound (freehand 3D US), where the shape of tissue is reconstructed by stacking two-dimensional (2D) slices acquired in varying probe positions and contact forces, the corresponding pixels can be accurately aligned only if different deformation patterns in each slice can be appropriately corrected. Furthermore, deformation correction applied in 3D US facilitates accurate quantitative measurement of volumes and tissue shape analysis. The need to correct deformation also arises in multimodal image processing, in which tissue deformation in ultrasound scanning has to be corrected before the image can be accurately registered with those from other modalities. Several deformation correction methods have been reported, aiming to estimate zero-force images that would have been acquired as if there had been no probe contact. In the method proposed by Treece et al. 1, probe position measurement was combined with image-based registration to correct deformation along the axial direction. Burcher et al. proposed the a priori finite-element method (FEM) model that could predict and correct tissue deformation in both the axial and lateral directions, which incorporated a priori knowledge of tissue elasticity and contact force measurement. 2 A two-dimensional deformation correction method, for reducing dependence on elastic property assumptions, based on speckle tracking and pixel trajectories was described by Burcher 3. In this method, linear dynamics was used for describing the mechanical behaviors of biological tissue under compression, which is only applicable over a small range of contact forces. *banthony@csail.mit.edu Medical Imaging 2010: Ultrasonic Imaging, Tomography, and Therapy, edited by Jan D'hooge, Stephen A. McAleavey, Proc. of SPIE Vol. 7629, 76290A 2010 SPIE CCC code: 1605-7422/10/$18 doi: 10.1117/12.844184 Proc. of SPIE Vol. 7629 76290A-1

In this paper, a novel trajectory-based deformation correction method, incorporating contact force measurement and two-dimensional displacement estimation, is described. This method aims to provide an accurate model of biological tissue deformation, and to be applicable to correcting large tissue deformation. The method was validated by a numerical phantom study; the performance of deformation correction is analyzed by contour extraction and area estimation. 2. METHODS In order to characterize tissue deformation, pixel displacement estimation was performed between ultrasound images under different contact forces. Knowledge of contact force and the corresponding pixel displacements allowed the construction of a trajectory field for the specific subject under an ultrasound scan. Pixel coordinates in the scan planes were plotted against the corresponding contact forces. After the trajectory field was built, an extrapolation algorithm was applied on each pixel-trajectory to relocate the pixel to where it would have been had there been no contact force, thereby reconstructing the undeformed tissue appearance. This method was validated by using FEM and ultrasound simulation. The essential steps of this procedure are described in the following subsections. 2.1 Displacement field estimation Tissue deformation due to probe compression was estimated by pixel displacement fields, which described how each part of tissue moved when a certain contact force was applied. For characterizing force-varying deformation patterns, a set of displacement fields were established by tracking each pixel over the whole field of view along a sequence of ultrasound images under varying contact forces, as shown in Figure 1. Figure 1. Tissue deformation states could be modeled by tracking each single pixel in the field of view along the B-mode image sequence under varying contact forces. A 2D displacement estimation algorithm was implemented based on the template-matching method proposed by Zahiri-Azar et al. 4 In this method, pre-compression RF A-lines were axially divided into overlapping windows with a length of 1mm. Each windowed pre-compression segment was then compared with the corresponding post-compression RF A-line in order to find the most similar segment; normalized cross correlation was used as a similarity measure. Interpolation was performed on the sampled cross correlation functions in order to achieve sub-sample accuracy displacement estimation. Cosine curve fitting through three sample points was used as the interpolation scheme. 5 Finally, instead of applying the 1D procedure in the axial and lateral directions independently, estimation in the lateral direction was performed only after the axial displacement was determined, since pixel displacements in the two directions are physically coupled. Proc. of SPIE Vol. 7629 76290A-2

2.2 Trajectory field and extrapolation A trajectory field is then established by plotting the 2D coordinates of each pixel against the corresponding contact force, as shown in Figure 2. The location where a pixel would have been if there had been no contact force is estimated by finding the intersection of the corresponding trajectory and the zero-force plane. Through application of this algorithm to all pixels in the trajectory field, deformation of tissue in the image is corrected. Both linear and nonlinear polynomial extrapolation methods were tested in this study because it has been widely reported that, when compressed, biological tissue exhibits significant nonlinear mechanical behaviors 6, whose characterization might require more than one degree of freedom. The results of this regression analysis are described in section 3. RESULTS AND DICUSSION. Figure 2. The B-mode image that one would have acquired if there had been no contact could be reconstructed by performing extrapolation over the trajectory field, which describes pixel movement with changing contact force. 2.3 Numerical phantom study Performance of the deformation correction method was validated through the use of FEM and the ultrasound simulation software Field II. 7-8 A numerical phantom was built in FEM in order to simulate the mechanical behaviors of breast tissue under probe contact. A corresponding phantom was built in Field II for simulating B-mode images of the numerical phantom in FEM under varying deformation states. Finally, those B-mode images, as well as the contact force measurements in FEM, were used to build a trajectory field for estimating the undeformed appearance of the simulated pathological tissue embedded in the phantom. 2.3.1 Finite-element method (FEM) A 100mm 60mm numerical phantom that simulated breast tissue was built in commercial FEM software (Abaqus 6.8, HKS, Rhode Island). Inside the phantom, a circular region with a radius of 7.5mm was set to have higher stiffness for mimicking pathological tissue, and its center was placed 22.5mm below the top surface of the phantom, as shown in Figure 3. Consistent with the displacement estimation method described earlier, which ignored displacement in the elevational direction (perpendicular to the scan plane), the FEM modeling and simulation were set to be two-dimensional, that is, in the axial and lateral directions. Here the mechanical behaviors of the phantom undergoing finite strains were described by hyperelastic models. In addition, the phantom was assumed to be isotropic and incompressible. Out of several models that characterize such Proc. of SPIE Vol. 7629 76290A-3

material, the Neo-Hookean model was chosen for simulation. The model can be described by the strain energy potential function in Equation (1). U C I 3) (1) 10 ( 1 where U is the strain energy per unit volume, I1 is the first deviatoric strain invariant, and C10 is the material parameter. According to previously reported ex-vivo experimental results 6, the value 3.1 10-4 N/mm 2 was assigned to the parameter C 10 for the region in the phantom that mimicked normal breast tissue, and four times that value were used for the harder inclusion for mimicking pathological tissue. A rigid indenter mimicking an ultrasound probe (vermon LA 5.0/128-522) was modeled and used to compress the phantom against the rigid plane at the bottom. It should be noted that, in ultrasound scanning, the subject is scanned with respect to the probe. Therefore, features in the phantom would seem to be moving upward in the image when being compressed, while they would actually move downward physically. In order to simulate tissue deformation measured in the coordinate system of the probe, in the compression simulation the probe was fixed, while the rigid plane was set to be moving upward. The numerical phantom was a mesh of 3724 plane strain quadrilateral elements with 3825 nodes. Compression and the resulting tissue deformation were then simulated in a quasi-static manner for describing very slow motion and ignoring inertial effects. Figure 3. The setup in FEM is shown. A harder inclusion was embedded in the numerical phantom for mimicking pathological tissue. For simulating probe compression, the probe was fixed and the bottom rigid plane pushed upward, since the scan plane follows the coordinate system of the probe. 2.3.2 Ultrasound simulation For simulating the B-mode images of the numerical phantom in FEM, a corresponding phantom was modeled in the ultrasound simulation software Field II. 2 10 5 scatterers were randomly distributed in a 100mm 60mm 10mm cube. The top surface of the phantom was 30mm below the probe. A sampled set of the scatterers is shown in Figure 4. The circular region marked in blue corresponded to the simulated pathological tissue in FEM, and the region was set to have a higher average of acoustic impedance in Field II. The rectangular region bounded by dashed lines indicates the field of view in the simulated ultrasound scanning. In order to simulate B-mode images of the numerical phantom in varying deformation states, the results of nodal displacement measurement in FEM deformation analysis were linearly interpolated to relocate the scatterers to where they would be if the phantom were compressed. Here in the simulation, a linear probe array was modeled, with a center Proc. of SPIE Vol. 7629 76290A-4

I-I iai frequency of 5MHz and a sampling rate of 60MHz, and the transmit focus was set to be 55mm in depth. The pitch of the probe array was 0.3mm, and 64 elements were used for every scan line. An image was composed of 128 scan lines, with a spatial spacing of 0.3mm in the lateral direction. Figure 4. A sampled set of the scatterers of the phantom in ultrasound simulation is shown. The region bounded by dashed lines indicates the field of view, and the region marked in blue corresponds to the simulated pathological tissue in FEM. 3. RESULTS AND DISCUSSION For validating the proposed deformation correction method, ten B-mode images were simulated from compression of the numerical phantom in FEM by 5mm to 14mm, with a spacing of 1mm. The reaction forces sensed by the probe in the compression simulations were also calculated. The trajectory field between the ten images was then determined after the displacement fields between consecutive B-mode images were estimated and median-filtered with a 15 15 kernel. Although an arbitrary selection out of the ten images (5mm to 14mm compression) could be used for estimating the uncompressed inclusion appearance, the results of correcting the image under 14mm compression, which corresponds to a large strain of over 20%, are shown here as an example. The performance of correcting for 14mm compression was examined through comparison of the inclusion contours in the corrected and uncorrected images. The contours were extracted by the Gradient Vector Flow for Snake (GVFsnake) algorithm 9. The GVF algorithm uses diffusion of the gradient vectors derived from gray-level edge maps as an external force for active contour fitting. The snakes were initialized by the use of an interactive graphical user interface (GUI), and then gradually shrunk to delineate the edges of the inclusions by iteration. The squared magnitudes of the gradient fields derived from the B-mode images were used as the edge maps. The GVF-snake algorithm has been shown to be relatively insensitive to contour initialization, and to be able to converge to boundary concavities. The GVF-snake software is available at http://iacl.ece.jhu.edu/projects/gvf. Figure 5 shows the results of correction by the use of linear regression for extrapolation on the trajectory field. It can be seen that both the shape and position of the compressed inclusion deviated significantly from those of the inclusion in the uncompressed state. These deviations were largely removed after linear correction. The improvement in estimating the uncompressed inclusion contour was further quantified by three parameters that characterize area estimation error: true positive (TP), false negative (FN), and false positive (FP). 10 Those parameters are illustrated in Figure 6. From Table 1, the area estimation error parameters improved significantly after linear deformation correction. Proc. of SPIE Vol. 7629 76290A-5

14mm-compressed inclusion linearly corrected inclusion 35 35 Axial distance [mm] 40 45 50 55 60 65 Axial distance [mm] 40 45 50 55 60 65 70 70 75-10 0 10 20 Lateral distance [mm] 75-10 0 10 20 Lateral distance [mm] (a) (b) Axial distance [mm] 35 40 45 50 55 60 65 70 75 uncompressed inclusion -10 0 10 20 Lateral distance [mm] (c) Axial distance (mm) 40 45 50 55 60 GVF contours -10 0 10 Lateral distance (mm) (d) uncompr. 14mm-compr. linearly corr. Figure 5. The B-mode image of the 14mm-compressed inclusion (a) was linearly corrected (b). From the comparison between (a), (b) and the true uncompressed inclusion contour (c), it was shown that the proposed method could largely restore the shape and position of the inclusion to its uncompressed state. (d) Proc. of SPIE Vol. 7629 76290A-6

Figure 6. The performance of deformation correction was quantified by three parameters that were derived from area estimation. They are true positive (TP), false positive (FP), and false negative (FN). Table 1. The area estimation parameters derived from comparing the 14mm-compressed and the linearly corrected contours with the true uncompressed contour in Figure 5. TP FN FP 14mm compression 0.56 0.44 0.49 linear correction 0.96 0.04 0.13 The performance of deformation correction by nonlinear polynomial regression was also examined. The image of 14mm-compressed numerical phantom was corrected by the use of polynomial regression of order one to four. Then a GVF snake was initialized to extract the inclusion contours in the four corrected images, as well as the image in the uncompressed state. The contour extraction procedure was repeated ten times, in each of which a different initial GVF snake was used. The initial snakes were drawn in a manner that all of the five inclusions would be enclosed. Figure 7(a) shows a typical example with the extracted contours overlaid. The contours from 2 nd - to 4 th - order regressions varied insignificantly and were close to the uncompressed contour. There was noticeable deviation between the contours from linear and nonlinear regressions. Figures 7(b)-(d) show the area estimation parameters derived from results of the ten contour extraction procedures, where the error bars indicate standard deviations in each measure. By paired t-test, it was shown that nonlinear polynomial regression outperformed linear regression (p<10-10 for all three parameters.) In addition, the 3 rd -order polynomial regression gave better TP and FN measures than the others (p<10-5 ), while in terms of FP, the difference between 3 rd -order regression and the other nonlinear ones was not statistically significant. Therefore, considering both performance of correction and the required computational cost, 2 nd -order polynomial regression should make the best balance. Proc. of SPIE Vol. 7629 76290A-7

Axial distance (mm) GVF contours 50 55 60-10 -5 0 5 10 Lateral distance (mm) (a) uncompr. 1st 2nd 3rd 4th TP 1 0.99 0.98 0.97 True Positive (TP) 0.96 0 1 2 3 4 5 Polynomial regression order (b) 0.04 False Negative (FN) 0.08 False Positive (FP) 0.03 0.07 FN 0.02 FP 0.06 0.01 0.05 0 0 1 2 3 4 5 Polynomial regression order 0.04 0 1 2 3 4 5 Polynomial regression order (c) (d) Figure 7. Comparison of the inclusion contours after deformation correction incorporating 1 st -, 2 nd -, 3 rd -, or 4 th - order polynomial regression is shown. (a) From the area estimation parameters (b)-(d), nonlinear regression gave better estimation accuracy than linear regression, but an order higher than two did not lead to improvement in performance. 4. CONCLUSION In this study, a novel method for correcting tissue deformation in ultrasound images was presented. It involves measuring the contact force between the probe and skin surface while performing an ultrasound scan. A 2D trajectory field is estimated from displacement fields between consecutive scans and contact force measurements. Tissue deformation in the B-mode images is then corrected by extrapolating pixel trajectories back to zero force. This method was evaluated by FEM and ultrasound simulation, in which a harder inclusion was embedded in the numerical phantom for mimicking pathological tissue. It was shown that the proposed method could reconstruct the appearance of the uncompressed inclusion in semi-automatic contour extraction. Furthermore, when correcting large deformation with a strain of over 20%, the method was found to perform better when nonlinear polynomial regression was used for extrapolation, although a polynomial order higher than two did not give better accuracy in area estimation. Proc. of SPIE Vol. 7629 76290A-8

ACKNOWLEDGEMENT The research was sponsored by Singapore-MIT Alliance (SMA). The authors also thank Terason for donating the t3000 ultrasound imaging system and their technical support. REFERENCES [1] Treece, G.M., Prager, R.W., Gee, A.H., and Berman, L., Correction of probe pressure artifacts in freehand 3D ultrasound, Medical Image Analysis 6, 199 214 (2002). [2] Burcher, M.R., Han, L. and Noble, J.A., Deformation correction in ultrasound images using contact force measurements, Proceedings of the IEEE Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA'01) 63 (2001). [3] Burcher, M., [A Force-based Method for Correcting Deformation in Ultrasound Images of the Breast], University of Oxford, (2002). [4] Zahiri-Azar, R. and Salcudean, S.E., Real-time estimation of lateral displacement using time domain cross correlation with prior estimates, IEEE Ultrasonics Symposium, 2006 1209 1212 (2006). [5] Zahiri-Azar, R., Goksel, O., Yao, T.S., Dehghan, E., Yan, J., and Salcudean, S.E., Methods for the estimation of sub-sample motion of digitized ultrasound echo signals in two dimensions, EMBS 2008. 30th Annual International Conference of the IEEE 5581 5584 (2008). [6] Samani, A. and Plewes, D., A method to measure the hyperelastic parameters of ex vivo breast tissue samples, Physics in Medicine and Biology 49, 4395 4406 (2004). [7] Jensen, J.A. and Svendsen, N.B., Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control 39, 262 267 (1992). [8] Jensen, J.A., Field: A program for simulating ultrasound systems, Medical and Biological Engineering and Computing 34, 351 352 (1996). [9] Xu, C. and Prince, J.L., Snakes, shapes, and gradient vector flow, IEEE Transactions on image processing 7, 359 369 (1998). [10] Madabhushi, A. and Metaxas, D.N., Combining low-, high-level and empirical domain knowledge for automated segmentation of ultrasonic breast lesions, IEEE transactions on medical imaging 22, 155 169 (2003). Proc. of SPIE Vol. 7629 76290A-9