USER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)

Similar documents
USER MANUAL. MODEL 1082 and 1082/144 idsl Modem with V.35 or X.21 Interface. An ISO-9001 Certified Company

USER MANUAL MODEL CopperLink Ethernet Extender SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODELS 2156 & CopperLink Ethernet Extenders SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 2014 Interface Powered RS-530 to V.35 Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL Bidirectional (IEEE-1284) Line Driver/Converter

An ISO-9001 Certified Company

USER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

USER MANUAL. MODELS 1205 and 1205/34. Synchronous V.35 Modem Eliminators

USER MANUAL. MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem

USER MANUAL. MODEL 1082/I and 1082/144/I idsl Modem with 10Base- T Interface. An ISO-9001 Certified Company

USER MANUAL MODEL User Network Access Bridge. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 505M-CHC. Surge Protected DB-25 to RJ-45 Modular Adapter

USER MANUAL MODEL CopperLINK High Speed Ethernet Extenders

USER MANUAL MODEL KiloModem II AC Powered, High-Speed X.21 Short-Range Modem

USER MANUAL MODEL 515 DB-15 Surge Protector

USER MANUAL. MODEL 552 Series. High Speed Telco Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. TS Series (Model 52X) Terminal Strip Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 56X Series 564, 566, 568, 562. Hub Surge Protectors

USER MANUAL MODEL 503P & 503PC. Parallel Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 222N9. Ultra-miniature RS-232 (EIA-574) to RS-422 Interface Converter

USER MANUAL MODEL 536S Token Ring (STP) Surge Protector. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL CopperLINK Ethernet Extender. This is a Class A device and is not intended for use in a residential environment.

USER MANUAL. MODEL 1090 High Speed Synchronous Short Range Modem. Dear Valued Customer,

USER MANUAL MODEL 1089 C and D HDSL Modem with V.35 or X.21 Interface

XC300 VDSL Network Extender Owners Manual

USER MANUAL MODEL 570/ Base-T (CAT-5) Surge Protectors SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL 570-R8/570-R R8/580-R Base-T (CAT-5) Surge Protectors

USER MANUAL MODEL 1089/I 10BaseT HDSL Rocket

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

USER MANUAL. MODEL 1000P Non-Powered Short Haul Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Conitel ASYNC Adapter

USER MANUAL MODEL 1010RC. Miniature Short Range Modem with Transformer Isolation: Rack Mount Card

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

USER MANUAL MODEL 571/ Base-T (CAT-5) Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Enclosure TS-530 User Manual

G.SHDSL IAD. iprocketlink Model Quick Start Guide

USER MANUAL MODEL IM 1/I. Ethernet Bridge Module. SALES OFFICE (301) TECHNICAL SUPPORT (301)

OPERATOR S MANUAL MODEL DSU-56SA. 56 Kbps Stand Alone CSU/DSU

USER MANUAL MODEL 1018RC. Powered High Speed Short Range Modem: Rack Mount Card

USER MANUAL. MODEL 2500 Series. Models 2500, 2510, 2520 All-Rate CSU/DSU SALES OFFICE (301) TECHNICAL SUPPORT (301)

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

EasySync Ltd. ES-R-2x01-M RS232 to RS422 / RS485 Converter. User Guide. Document Reference No.: ES_ Version draft Issue Date:

T1/E1 Channelized Gigabit Router

USER MANUAL MODEL 1095

SPL Hub TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...4

Enhanced Mini-Chansim Model VCS-232

8-Port USB-to-Serial RS232 Adapter Hub with Daisy Chain - Rack Mountable

fiber optic gateway control box

Cable and Port Specifications

USB to RS232 Adapter

D56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7

USER MANUAL. Model 2070 Series. V.24/X.21/V.35 to G.703 Interface Converter

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

SIP 3CX Based Private Branch Exchange

G.SHDSL NTU with Fixed Serial Interfaces

IC-485S /IC-485SI. If anything is damaged or missing, contact your dealer.

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

Leased-Line Extenders over IP

Interface Converter. Installation Manual IC485S IC485SGB IC485SEU. RS-232 to RS-485/422 Serial Interface Converter

1206P (CTS ME-X.21) MODEM ELIMINATOR, X.21 INSTALLATION AND OPERATIONS MANUAL. Doc #: UA Part #: 07M1206P-A

Miniature Asynchronous 4-Wire High Speed Modems

Instruction Guide. Two Port ISA Serial Card ISA2S550. The Professionals Source For Hard-to-Find Computer Parts

DATA CONNECT ENTERPRISE

Professional USB to Serial Adapter Hub with COM Retention

DeviceMaster RTS 16-Port Hardware Installation

Cable and Port Specifications

F2238A and F2245A Fiber-Optic EIA-530/MIL-STD Modem Technical Manual

Megabit Modem MM300S INSTALLATION GUIDE

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

SCADA Point-to-Point Multiplexer

ME778C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: 10-Pin RJ.

WIRESPEED ADSL MODEM (MODEL 2000) User Guide

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

Boca s Family of Ethernet Products

SeaLINK+232I USER MANUALM

Xtreme/104. PC/104 Serial Communications. User Manual

ME500A BLACK BOX SPECIFICATIONS: BOTTOM OF UNIT INTRODUCTION: CONFIGURATION: Async Sync Industrial Line Driver PWR TX RX RTS CD. DB25 Female Conn.

Cable and Port Specifications

Hardened Ethernet to VDSL2 Extender. User Guide. Revision History. Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Rev.1.

COMM+16.PCIe User Manual Part Number 7161e

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1

SeaLINK+8/USB. Sealevel Systems, Inc 155 Technology Place P.O. Box 830 Liberty, SC USA

Data Sheet SRM-3A. Ultra-Miniature Isolated Short-Range Async Modem. The Access Company

COMM+8.LPCI Users Manual Part Number 7803

DSU 5600 Data Service Unit USER MANUAL

4 Port 10/100 VDSL Ethernet Extender Kit over Single Pair - 1km

NT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2.

Ethernet Extender. EnviroNET 2100 Series. Quick Start Guide

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

Contents INTRODUCTION...1 CARD SETUP...2 INSTALLATION TECHNICAL DESCRIPTION SPECIFICATIONS... 14

Telephone Line Monitor USER GUIDE

Itona TC73yy Hardware User s Guide

Itona DxxS Hardware User s Guide

ME930C-RJ11 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-11 INTERFACE MODULE (REAR CARD) Serial: DB25 CONN. SW1 RJ-11 CONN.

TC1900 "QUICK TALK" RS-232 or Fiber Telephone Extender User's Manual

Transcription:

USER MANUAL MODEL 1052 idsl Modem with RS-232 Interface An ISO-9001 Certified Company Part# 07M1052-B Doc# 058061UB Revised 5/24/02 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007

TABLE OF CONTENTS 1.0 Warranty Information... 4 1.1 FCC Information... 4 1.2 CE Notice... 4 1.3 Service... 5 2.0 General Information... 6 2.1 Features... 6 2.2 Description... 6 3.0 Configuration... 7 3.1 Configuring the Hardware DIP Switches... 7 Configuring DIP Switch S1... 8 Switches S1-1 and S1-2: Data Rate... 8 Switch S1-3... 9 Switch S1-5: Asynchronous/Sync Operation... 9 Switches S1-6 and S1-7: System Clock Mode... 9 Switch S1-8... 10 Configuring DIP switch S2... 10 Switch S2-1: 19.2 kbps Synchronous Rate... 10 Switch S2-2: Must be set to the ON position (Reserved).... 11 Switches S2-3... 11 Switches S2-4 and S2-5: Not Assigned... 11 Switch S2-6... 11 Switch S2-8: Not Assigned... 11 4.0 Installation... 12 4.1 Connecting the Twisted Pair Interface... 12 4.2 Connecting the Connecting the Model 1052/A (RS-232)... 13 Connecting the Model 1052/A (RS-232) to a DTE Device... 13 4.3 Power Connection... 13 Universal AC Power (100 240 VAC)... 14 DC Power... 14 5.0 Operation... 15 5.1 Power-up... 15 5.2 LED Status Monitors... 15 A MODEL 1052 SPECIFICATIONS... 16 A.1 Transmission Format... 16 A.2 Transmission Line... 16 A.3 Control Signals... 16 A.4 Clocking... 16 A.5 Distance... 16 A.6 Data Rates... 16 A.7 LED Status Indicators... 16 A.8 Connectors... 16 A.9 Power... 16 2

A.10 Temperature Range... 17 A.11 Altitude... 17 A.12 Humidity... 17 A.13 Weight... 17 A.14 Line Interface... 17 B Models 1052/A Factory Replacement Parts and Accessories... 18 C Model 1052/A Interface Pin Assignments... 19 3

1.0 WARRANTY INFORMATION Patton Electronics warrants all Model 1052 components to be free from defects, and will at our option repair or replace the product should it fail within one year from the first date of shipment. This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user. 1.1 FCC INFORMATION This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 1.2 CE NOTICE The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the Union European (EU). A Certificate of Compliance is available by contacting Patton Technical Support. 4

Conformity documents of all Patton products can be viewed online at www.patton.com under the appropriate product page. Important 1.3 SERVICE All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Service at: Tel: (301) 975-1007 E-mail: support@patton.com URL: www.patton.com Note Packages received without an RMA number will not be accepted. Patton Electronics technical staff is also available to answer any questions that might arise concerning the installation or use of your Model 1052. Technical Service hours: 8AM to 5PM EST, Monday through Friday. 5

2.0 GENERAL INFORMATION Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Year parts and labor. If any questions or problems arise during installation or use of this product, please do not hesitate to contact Patton Electronics Technical Support at (301) 975-1007. 2.1 FEATURES Synchronous data rates: 19.2, 32, 56, 64, and 128 kbps Asynchronous data rates: 0 38.4 kbps Full duplex operation over a single twisted pair (2-wires) Point-to-point distances up to 5 miles (all data rates) on 24 AWG twisted pair Multi-rate symmetric DSL RS232 Interface Compatible with popular Models 1092A and 1082 Passes transmit and receive data, and one control signal in each direction Universal power options, 120 VAC and -48, -24, and -12 VDC available Front panel status indicators Small, convenient desktop unit CE marked 2.2 DESCRIPTION The Patton Model 1052 is a high speed, AC powered short range modem that is able to operate synchronously or asynchronously full duplex over a single twisted pair. Supporting data rates up to 128 kbps (synchronous) or 38.4 kbps (asynchronous), the Model 1052 is capable of point-to-point distances up to 5 miles (8 km) using 24 AWG wire. The Model 1052 supports internal, external or receive loopback clocking in synchronous mode. Data rates and asynchronous data format may be configured locally using DIP switches. The Model 1052/A provides an RS232 interface on a DB-25 female connector. Line connection is made by an RJ-45 jack. Standard versions of Model 1052 are powered by a 100 240 VAC (Universal) supply. The DC power supply options support either -12, -24, or -48 VDC. 6

ON ON S1 3.0 CONFIGURATION The Model 1052 is equipped with 16 DIP switches that enable configuration of the unit for a wide variety of applications. This section describes switch locations and explains the different config-urations 3.1 CONFIGURING THE HARDWARE DIP SWITCHES S1 and S2 each contain eight internal DIP switches (see Figure 1) that are used for configuration reset purposes only. To access switch set SW1, use a small flat blade screwdriver to open the Model 1052 s case as shown in Figure 2 on page 8. S1 S2 1 2 3 4 1 2 3 4 5 6 7 8 S2 5 6 7 8 ON Switch toggle 1 2 3 4 5 6 7 8 Push toggle up for ON position Push toggle down for OFF position ON 1 2 3 4 5 6 7 8 Figure 1. DIP switches S1 and S2 To configure the DIP switches, use a small screwdriver and gently push each switch to its proper setting. The ON and OFF positions are shown in Figure 1. 7

Figure 2. Opening the Model 1052 case Figure 1 on page 7 shows the orientation of the DIP switches in the ON and OFF positions. Configuring DIP Switch S1 DIP switch S1 is where you configure the data rate, asynchronous or synchronous data format, transmit clock source. The following table summarizes default positions of DIP switches S1-1 through S1-8. Detailed descriptions of each switch follow the table. S1 Summary Table Position Function Factory Default S1-1 Data Rate Off S1-2 Data Rate Off S1-3 S1-4 Reserved Reserved On On S1-5 Async/Sync Data Format Off S1-6 Tx Clock Source On S1-7 Tx Clock Source On S1-8 Reserved Off } } 128K Sync Internal Clock Switches S1-1 and S1-2: Data Rate. Use switches S1-1 and S1-2 to configure the asynchronous or synchronous data rate of the Model 1052. 8

Each setting represents one synchronous data rate and one asynchronous data rate. S1-1 S1-2 Sync Data Rate Async. Data Rate Off Off kbps or 19.2 kbps Reserved On On 32 kbps Reserved Off On 56 kbps Reserved On Off 64 kbps Reserved Off Off 128 kbps (see note) 0 38.4 kbps Note If the S2-1 switch is positioned in the OFF position, the 128 kbps sync data rate/0 38.4 kbps async data rate option is selected. Switch S1-3. Must be set to the On position (Reserved). S1-3 Setting On Reserved Switch S1-4: Must be set to the ON position (Reserved). S1-4 Setting On Reserved Switch S1-5: Asynchronous/Sync Operation. Use Switch S1-5 to configure the Model 1052 for async/sync operation. Switch S1-5 must be set in the Off position. There is no other valid setting. S1-5 Setting Off Async/Sync Switches S1-6 and S1-7: System Clock Mode. Use Switches S1-6 and S1-7 to configure the 1052 for internal, or receive recover clock mode. S1-6 S1-7 Clock Mode Description On On Internal System clock generated internally Off On External (DTE) System clock derived from terminal interface On Off Receive Recover System clock derived from the received line signal Off Off Hardware Reset 9

Important A pair of Model 1052s communicate synchronously across the twisted pair line connection. Therefore, you must set these switches whether your application is async or sync. For Sync or Async applications, please configure one Model 1052 for internal clock mode and the other Model 1052 for receive recover clock mode. Switch S1-8. Must be set to the Off position (Reserved). S1-8 Setting Off Reserved Configuring DIP switch S2 Use the eight DIP switches in S2 to enable 19.2 kbps synchronous operation and set the loopback modes. The following table summarizes default positions of DIP switches S2-1 through S2-8. Detailed descriptions of each switch follow the table. Table 1: S2 Summary Table Position Function Factory Default S2-1 19.2 kbps Enable Off S2-2 RESERVED Off S2-3 Reserved Off S2-4 Not Assigned Off S2-5 Not Assigned Off S2-6 Reserved Off S2-7 Compatibility Mode Off S2-8 Not Assigned Off Switch S2-1: 19.2 kbps Synchronous Rate. Enable Switch S2-1 to allow the Model 1052 to operate at the 19.2 kbps synchronous data rate. S2-1 Activation Description Off Disabled Synchronous data rate is 32 128 kbps as defined by switches S1-1 and S1-2 On Enabled Model 1052 operates at synchronous 19.2 kbps data rate 10

Switch S2-2: Must be set to the ON position (Reserved). S2-2 S2-2 Setting On Reserved Switches S2-3. Must be set to the Off position (Reserved). S2-3 Description Off Reserved Switches S2-4 and S2-5: Not Assigned. Switch S2-6. Must be set to the Off position (Reserved). S2-6 Description Off Reserved Switch S2-8: Not Assigned. 11

TXD 4.0 INSTALLATION Once the Model 1052 has been configured, it is ready to connect to the twisted pair interface, to the serial port, and to the power source. This section tells you how to make these connections. RS-232 port Gaithersburg, Maryland Model 1052/A ER idsl Model With RS-232 Interface DSL LINK NS RXD RJ-45 DSL interface Power jack Figure 3. Model 1052 Rear Panel 4.1 CONNECTING THE TWISTED PAIR INTERFACE The Model 1052 supports communication between two DTE devices at distances to 5 miles (8 km) over 24 AWG (0.5mm) twisted pair wire. Two things are essential: These units work in pairs. Both units at the end of the twisted pair DSL span must be set for the same DTE rate. To function properly, the Model 1052 needs one twisted pair of metallic wire. This twisted pair must be unconditioned, dry, metallic wire, between 19 (0.9mm) and 26 AWG (0.4mm) (the higher number gauges will limit distance). Standard dial-up telephone circuits, or leased circuits that run through signal equalization equipment, or standard, flat modular telephone type cable, are not acceptable. The RJ-45 connector on the Model 1052 s twisted pair interface is polarity insensi- 12

Gaithersburg, Maryland TM idsl Modem With RS-232 Interface ER NS NS ER TM tive and is wired for a two-wire interface. The signal/pin relationships are shown in Figure 4. Figure 4. Model 1052 twisted pair line interface 4.2 CONNECTING THE CONNECTING THE MODEL 1052/A (RS-232) The Model 1052/A supports RS-232 serial port connections. This section describes how to connect the serial ports to your RS-232 equipment. Connecting the Model 1052/A (RS-232) to a DTE Device The Model 1052/A provides an RS-232 DCE (data communications equipment) interface on a DB-25 female connector. As a DCE, this interface is designed to connect to DTE equipment, such as a router. When connecting the RS-232 interface of the Model 1052/A to your DTE device, use an RS-232 straight-through cable (see Figure 5). Appendix C on page 19 describes pin assignments and signal sources for the Model 1052/A RS-232 interface. When purchasing or constructing an interface cable, use the pin diagrams in Appendix C as a guide. Model 1052 TXD Model 1052/A RXD DSL LINK DSL Span DSL LINK RXD Gaithersburg, Maryland Model 1052/A idsl Modem With RS-232 Interface TXD Straight-through 25-pin D-sub cable Model 1052 (DCE) V.24 Router (DTE) Figure 5. Connecting the Model 1052/A to an RS-232 serial DTE 4.3 POWER CONNECTION The Model 1052 (all versions) are available with Universal AC (100 240 VAC), 120 VAC, 230 VAC or -12, -24, or -48 VDC power options. This section describes these options. 13

Universal AC Power (100 240 VAC) The Model 1052 uses a 5VDC, 2A universal input 100-240VAC, power supply (center pin is +5V). The universal input power supply has a male IEC-320 power entry connector. This power supply connects to the Model 1052 by means of a barrel jack on the rear panel. Many international power cords are available for the universal power supply (Refer to Appendix B on page 18 for country-specific power cords. The Model 1052 powers up as soon as it is plugged into an AC outlet there is no power switch.the Universal AC supply is equipped with a male IEC-320. DC Power The optional -12, -24, or -48 VDC DC-to-DC adapter supplied with the DC version of the Model 1052 plugs in a DC source (nominal -12, -24, or -48 VDC) and plugs into the barrel power supply jack on the rear of the 1052. Refer to Figure 6 to make the proper connection. To Power Supply Jack -Vin To -48VDC Source +Vin Figure 6. Connecting DC power to the 48V-PSM DC power supply WARNING There are no user-serviceable parts in the power supply section of the Model 1052. Fuse replacement should only be performed by qualified service personnel. Contact Patton Electronics Technical support at +1 (301) 975-1007, via our web site at www.patton.com, or by E-mail at support@patton.com, for more information. 14

5.0 OPERATION Once the Model 1052 is properly configured and installed, it should operate transparently. This sections describes power-up, reading the LED status monitors, and using the built-in loopback test modes. 5.1 POWER-UP Before applying power to the Model 1052, read section 4.3, Power Connection on page 13 to ensure that the unit is connected to the appropriate power source. 5.2 LED STATUS MONITORS The Model 1052 features five side panel LEDs (see Figure 7). Table 2 describes the function of each LED. Figure 7. Model 1052 side panel LEDs Table 2: LED descriptions LED TXD RXD DSL LINK NS ER Description (Active: Green) When lit, indicates data transmission. (Active: Green) When lit, indicates data transmission. (Active: Green) When lit, indicates that the end-to-end DSL framer link is up, signifying that the link across the DSL span is active. The DSL Link LED is off when the link is down. (Active: Yellow) When the No Signal LED is lit, it indicates that the local Model 1052 is not connected with the remote Model 1052 (Active: Red) Flashing red indicates that there are CRC errors on the DSL (framer) side if the DSL Link is active. ER flashes once to indicate a CRC error during normal operation 15

APPENDIX A MODEL 1052 SPECIFICATIONS A.1 TRANSMISSION FORMAT Synchronous or asynchronous A.2 TRANSMISSION LINE Single unconditioned twisted pair A.3 CONTROL SIGNALS CD and RTS A.4 CLOCKING Internal, external, or receive loopback A.5 DISTANCE Distance, max, all data rates: 10.1 miles (16.4km) on 19 AWG (0.9mm) wire 7.2 miles (11.5 km) on 22 AWG (0.64mm) wire 5.0 (8 km) on 24 AWG (0.5mm) wire 3.4 (5.5 km) on 26 AWG (0.4mm) wire A.6 DATA RATES Synchronous: 19.2, 32, 56, 64, and 128 kbps Asynchronous: 0 38.4 kbps A.7 LED STATUS INDICATORS TXD, RXD, DSL Link, NS (no signal), ER (CRC error) A.8 CONNECTORS RJ-45 on DSL line side; DB-25 female on serial interface side A.9 POWER 100 253 VAC, 50 60 Hz (universal input option); 48 VDC (optional), 5 watts 16

A.10 TEMPERATURE RANGE 32 122 F (0 50 C) A.11 ALTITUDE 0 15,000 feet (0 4,572 meters) A.12 HUMIDITY 5 95% non-condensing A.13 WEIGHT 2.01 lbs. (1.0 kg) A.14 LINE INTERFACE Transformer coupled 1500 VAC isolation 17

APPENDIX B MODELS 1052/A FACTORY REPLACEMENT PARTS AND ACCESSORIES Model # Description 1052/A RS232 idsl Modem 12V-PSM 12 VDC Power Supply Module 24V-PSM 24 VDC Power Supply Module 48V-PSM 48 VDC Power Supply Module 08055DCUI 100-240VAC (+5V ±5% reg. DC/2A) Universal Input Adapter 0805EUR European Power Cord CEE 7 ( A ) 0805UK United Kingdom Power Cord ( D ) 0805US American Power Cord ( K ) 0805AUS Australia/New Zealand Power Cord ( C ) 0805DEN Denmark Power Cord ( E ) 0805FR France/Belgium Power Cord ( F ) 0805IN India Power Cord ( G ) 0805IS Israel Power Cord ( H ) 0805JAP Japan Power Cord ( J ) 0805SW Switzerland Power Cord ( L ) 07M1052 User Manual 18

APPENDIX C MODEL 1052/A INTERFACE PIN ASSIGNMENTS RS-232 INTERFACE (DB-25 Female Connector) (DCE Orientation) Pin # Signal 1 Shield GND 2 TD (Transmit Data) (DTE Source) 3 RD (Receive Data) (DCE Source) 4 RTS (Request to Send) (DTE Source) 5 CTS (Clear to Send) (DCE Source) 6 DSR (Data Set Ready) (DCE Source) 7 SGND (Signal Ground) 8 CD (Carrier Detect) (DCE Source) 15 TC (Transmitter Clock) (DCE Source) 17 RC(Receiver Clock) (DCE Source) 18 LL (Local Analog Loopback) 20 DTR (Data Terminal Ready) (DTE Source) 21 RDL (Remote Digital Loopback) 24 XTC (External Transmit Clock) (DTE Source) 25 TM (TM (Test Mode) (DCE Source) 19

Notes Copyright 2002 Patton Electronics Company All Rights Reserved. 20