Energy 00 Installation Primary Switched Power Supply 00W EXWUID.0/LAN programmable V/I/P Ordering information Output Input Voltage Housing Dimensions see drawing Article No* EXWUID.0/LAN V = 0 - V* I = 0-0A* P = 0-00W* 00-0Vac 0x0x0mm -00-0 * Housing inside chrome plated, housing outside anodized * Delivery condition; Local Mode photo for example Overview page Ordering Informations Mechanical Dimensions Technical Data - Output Characteristics UL 090- CSA. No 090- IEC 090- Connection Assignments, Accessories Document.: 900.0 - also effective: description no 9900 9 0/0 /9
Energy 00 Installation Primary Switched Power Supply 00W EXWUID.0/LAN programmable V/I/P UL 090- CSA. No 090- IEC 090- Dimensions in mm X = Mains connection X = DC-Output connection X = Sense lead connection X = I/O-Signal connection X = Loadshare connection X = CAN connection (x) X = RS connection (x) View A = LEDs = Standby/on switch View B front side rear side configuration X X9 X X X X X X,0 0,0 X = USB connection X9 = LAN connection X = Ext. HMI,0 X 0 X 0,0* A --> <-- B.0 0.0 x M, mm thread depth for mounting 0.0 LOADSHARE X X optional X0 ANALOG SIGNAL + X + SENSE X OUTPUT OUT X CAN X IN RS X USB X9 optional SETTINGS LAN 0 Interfaceconfiguration via DIP-switch Interfaceconfiguration via EEPROM 0 --> --> ON 0 Analoginterface (optional) inactive Analoginterface (optional) active without function, X EXT. HMI X N MAINS INTERFACE 0 0 0 RS 0 0 CAN 0 0 USB 0 LAN* (optional) 0 0 reserved 0 reserved 0 reserved reserved L RESET BOOT SETTINGS CV OUT 0 --> --> RUN (CAN) BAUDRATE (kbit/s) ASCII CAN 0 0 9. 0 0 9. 0. 0. 000 CC * fixed. kbit/s FAIL ON STANDBY ON SETTINGS ERROR (CAN) Node ASCII CAN 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ON Caution Double pole / neutral fusing air intake -----> (in bottom sheet) The power supply is under voltage as soon as the mains input connector is applied with voltage. The units connectors may only be plugged or unplugged in mains-switch-off - condition. Otherwise the contacts of the plugs may be damaged..0.0.0 air outlet -----> * : Please note: plugs and connected electrical lines protrude the general outline of the unit. Please refer to the data sheets of the respective accessories. /9 0/0 Document.: 900.0 - also effective: description no 9900
Energy 00 Installation Primary Switched Power Supply 00W EXWUID.0/LAN programmable V/I/P Technical Data (Guaranteed values after a warm-up period of approx. min at nominal load, measured at the unit's output).0 Output Voltage* [Vdc] 0 - Output Current* 0-0 Output Power* [kw] of Regulation primary switched Efficiency Static 0 -.* Voltage Regulation Load Change 0 00% 0 Input Voltage Change (90-V) Load Change 0 00% RNOM [ma] 0 Input Voltage Change (90-V) [ma] Load Change inside of Vmax and Imax 0 Input Voltage Change (90-V) Current Regulation Power Regulation Dynamic Voltage Regulation Control Deviation D IO = 0 90% INOM Load Current Change dio/dt [A/µs] 00 0. Control Time for D IO = 0 90% INOM 0. Discharge Circuit Continuous Power (tol ±%) Peak Power (tol ±%) / 0 00 / 00 Programming Times V 0 Vmax Vmax 0% Vmax nominal load 0 open circuit 0 nominal load open circuit 0 Programming Times I 0 Imax V 0V (<%) 0 Imax 0 V 0V (<%) 0 * Set values below 0.% of maximum value are near the basic accuracy of the power supply. * For input voltages between 90 and 0Vac the maximum output power is limited to 000W. Document.: 900.0 - also effective: description no 9900 0/0 /9
Energy 00 Installation Primary Switched Power Supply 00W EXWUID.0/LAN programmable V/I/P UL 090- CSA. No 090- IEC 090- Technical Data (Guaranteed values after a warm-up period of approx. min at nominal load, measured at the unit's output).0 Quality Operating Frequency Ripple (00 khz) [mvpp] Superimposed Switching Spikes [mvpp] 00 [mvpp] 0 Residual Ripple (00 Hz - 00 khz) [mapp] 00 Residual Ripple (00 Hz) [mvpp] 0 Voltage Regulation Residual Ripple (00 Hz) Current Regulation Start-up Delay after Mains on Power-up Time after Standby/ON, Enable [s] < 0 Overvoltage Protection (OVP) Software Residual Voltage after Tripping 0 Sense Lead operation (load line compensation) max.. per load line Hardware (tol +.V) Input Voltage [Vac] Frequence (up to 0Hz on request) 00-0 ± 0% (90 - ) [Hz] 0-0 ± 0% ( - ) 0 Bridging Time tb 0 Prewarning Time tp In the Event of Mains Failure at Nominal Load: Buffer time tbuff Power Factor λ according to EN 000-0 0.9 Input Voltage Ieff max at Vin = /0Vac -0% /. Start Inrush Current IP for 0Vac 0 Unit Fuse (internal) x T Air inlet Temperature [ C] -0 0... +0, without derating; internal temperature regulated fan Storage Temperature Range [ C] - +0 Weight approx. [kg]. For definitions, information about electrical safety, EMC and mechanical stressability see the description. /9 0/0 Document.: 900.0 - also effective: description no 9900
Energy 00 Installation Primary Switched Power Supply 00W EXWUID.0/LAN programmable V/I/P Technical Data Programming Temperature Drift.0 [ppm/k] 0 (for all set values and actual values) V- Control Set Value Input. 0.0 0.0 max. Total Error (Dϑ K) 0. 0. absolute Error (Dϑ K) Actual Value Output (digital set value output value) (output value digital actual value). 0. 0.0 max. Total Error (Dϑ K) 0. absolute Error (Dϑ K) 0.0 I- Control Set Value Input (digital set value output value) [ma] 9. 0.0 0.0 max. Total Error (Dϑ K).0 absolute Error (Dϑ K) 0. Actual Value Output (output value digital actual value) [ma] 9. 0. 0.0 max. Total Error (Dϑ K) 0.9 absolute Error (Dϑ K) 0.9 P- Control Set Value Input (digital set value output value) [mw] 0 0.0 0.0 max. Total Error (Dϑ K).. absolute Error (Dϑ K) Actual value output (output value digital actual value) [mw] 0 0.0 0.0 max. Total Error (Dϑ K). absolute Error (Dϑ K) For set values < % of the nominal value, the unit operates in open-circuit output in two-limits mode, whereby the output ripple increases. For set value 0 the unit remains in open circuit and in the event of low load a residual voltage of lower 00mV remains at the output. Document.: 900.0 - also effective: description no 9900 0/0 /9
Energy 00 Installation Primary Switched Power Supply 00W EXWUID.0/LAN programmable V/I/P UL 090- CSA. No 090- IEC 090- Output Characteristics V/I/P - Setting ranges V/V,kW P-regulation 0 input voltage range 0Vac 0 I/A 0 /9 0/0 9 0 Document.: 900.0 - also effective: description no 9900
Energy 00 Installation Primary Switched Power Supply 00W EXWUID.0/LAN programmable V/I/P Connection Assignments Interfaces Connector accessories Mains Connection X PC /-ST-. L N Sense Lead Connection X IC./-STF-.0 I/O Signal Connection X (socket D-Sub-HD -pole) -S +S 0 Mains - Sense Lead ENABLE (A) * + Sense Lead ENABLE (K) * OUT-A (C): BO_CH00 (FS**) Neutral N Earth Loadshare Connection X MC./-STF-. DC Output Connection X IPC /-STF-0, - + V GND GND IN-C (A): BI_CH00 (QUIT FAILURE**) 9 IN-C (K): BI_CH00 (QUIT FAILURE**) 0 ENABLE (A)* ENABLE (K)* OUT-A (E): BO_CH00 (FS**) OUT-B (E): BO_CH0 (PFS**) OUT-C (E): BO_CH0 (VF**) - Output LS-GND + Output OUT-B (C): BO_CH0 (PFS**) OUT-C (C): BO_CH0 (VF**) LS Earth L (Shield) Document.: 900.0 - also effective: description no 9900 * With two Enable inputs ( and ) both Performance Level (PL) d according to EN ISO 9- and SafetyIntegrity Level (SIL) according to EN/IEC 0 are fulfilled. ** Default configuration Freely configurable signal input / output. Please refer to the chapter BIO (Binary input / output signals) in the description. 0/0 /9
Energy 00 Installation Primary Switched Power Supply 00W EXWUID.0/LAN programmable V/I/P UL 090- CSA. No 090- IEC 090- Connection Assignments Interfaces CAN Connection X (socket, x RJ) RS Connection X (Socket, x RJ) LAN Connection X9 (socket, RJ) Assignment according to IEC 0. CAN H CAN L GND-CAN GND-RS RxD TxD GND-CAN assignment according to Explanations see description. assignment according to CiA DRP0- Advice All metallic connector housings are related to protective earth. EIA- Ext. HMI X (socket, D-Sub-HD -pol.) USB Connection X (socket, type B) 0 Vcc DD+ GND /9 0/0 * s market nc may not be connected external. Internal connection Document.: 900.0 - also effective: description no 9900
Energy 00 Installation Primary Switched Power Supply 00W EXWUID.0/LAN programmable V/I/P Article-No. Mains connection with cable housing without cable housing X DC-Output connection X Sense lead connection Connector - PC /-ST-. screwable connections pole, 0. - mm² female 00--00 00-0-00 Connector - IPC /-STF-0. screwable connection pole, 0. - mm² male 00--00 X Connector - IC./-STF-.0 screwable connection pole, 0. -.mm² male 00-9-00 I/O-Signal connection X Connector D-SUB HD pole Stiftleiste solderable connections until AWG (0.mm² flex) 00-0-00 Loadshare connection X Connector - MC./-STF-. screwable connections pole, 0. -.mm² 00-0-00 CAN connection X Connector RJ (x) insulation-displacement terminal contacts, AWG - 00-0-00 RS connection X Connector RJ (x) insulation-displacement terminal contacts, AWG - 00-0-00 Kit 0 Kit consisting of: female Article-No. Article-No. mounted on device 0--00 0--0 x mounting strip x special screw M x Example unit with mounting strips 0.0 0.0 0.0 0 0.0.0 Accessories.0. 0.0 9.0 photo for example Document.: 900.0 - also effective: description no 9900 0/0 9/9