ADAPTER SERIES SST-AD60-C

Similar documents
電氣規格書 ESD NA

PRODUCT SPECIFICATION File: EA-A0601HE-12 Model: SSA-0601HE-12 Date: Apr. 17, 2015

Specification For 90 Watts Adapter Power Supply Model No: ADB002 Customer ID: 000G Revision: 4.0

PRODUCT SPECIFICATION File:SSA Model : SSA Rev:A2 Date: Nov. 29, 2010

ENGINEERING SPECIFICATION. 40W AC Adaptor. Part Number: PA W1

7.5 Watt AC-DC Switch Power Supply

FSP012(18)-DHXY3 Series

RoHS APPROVAL SHEET 15V/2.0A SERIES NO. (M04) EA1030CU CUSTOMER CUSTOMER P/N DESCRIPTION EDAC MODEL DATE REVISION 0 APPROVED DESIGN PREPARE

FSP018(24)-DHXN3 Series

ENGINEERING SPECIFICATION 90 WATT POWER SUPPLY PART NUMBER PA P1

ENGINEERING SPECIFICATION. 65W AC Adaptor. Part Number: PA P1

ENGINEERING SPECIFICATION SHEET SPEC. Revision History

SST-NJ450-SXL. Nightjar Series. The definitive small form factor fanless power supply

Safety Standards. Model Number:

Safety Standards. Model Number:

Safety Standards. Model Number:

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

ENGINEERING SPECIFICATION SHEET. Table of Contents 1 SCOPE ELECTRICAL SPECIFICATION...5

Safety Standards. Model Number: Unit Weight:

Constant Voltage Mode

Safety Standards. Model Number:

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

Safety Standards. Model Number:

ABP GROUP LIMITED SPECIFICATION FOR APPROVAL. Eckstein GmbH SAW GD. Manufacture Please check and confirm the specification

Safety Standards. Model Number:

SPECIFICATION. SFX Form Factor. SST-ST45SF 450W Switching Power Supply Active PFC Circuit Full Range Input. SFX Form Factor

POWERSOLVE ELECTRONICS LTD PSL400-XX series Conduction Cooled Power Supply Engineering Specification

RT4F-48V/50A-WAC RECTIFIER

RT4F-120V/20A-WAC RECTIFIER

LFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00

SPECIFICATION. Model: PS3038. Redundant Power Supply With Active PFC 700W + 700W

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

RT4B-110V/12A RECTIFIER

RT4F-110V/25A RECTIFIER

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

Electrical Specification for: efo Wide range AC/DC Single 12V Output 400W Power Supply Telkoor Part Number: CUSTOMER SIZE CAGE CO

Voltage Current Front-mounting bracket

CINT W Single Output Industrial Series

TFX PC Power Specifications

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Safety Standards. Model Number:

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Safety Standards. Model Number:

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 90% at 90V AC)

Power Factor Model Number Voltage Voltage

Safety Standards. Model Number:

SPECIFICATION. Model: OP650 Switching Power Supply With Active PFC PS/2 650W

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Safety Standards. Model Number:

< 50 A max. (115 VAC) / < 70 A max. (230 VAC)

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

275 Watt Medical Ultra low profile

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```


COMPUTER TECHNOLOGY CO., LTD. For Approval

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

The SFP BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD). Datacom Distributed Power Systems

RT12-240V/2.4kW Rectifier Specification

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

Series Specifications Ta= 25 C, nom. Vin, full load and after warm-up unless otherwise stated) Parameter Condition Min. Typ. Max.

AC-DC POWER SUPPLY UNIVERSAL INPUT, DESK TOP, WATTS MEDICAL APPLICATIONS MUI310-A Series

VP ELECTRONIQUE MASSY - Tel

APPROVED SIGNATURES/ 客户确认. Manufacturer/ 制造商

CPCI - 6U - AC - 600W

CINT W Triple Output Industrial Series

HEC-100RTN-48QSCA Rev A1.0

Lite-On Power ChungHo Controlled. Do Not Copy.

12-15VDC (12V±5%) 24-28VDC (24V±5%)

IS -680PD8. Switching Power Supply 680W) SPECIFICATION. Revision: 1.0

SPARKLE POWER INC. FSP120/150-AxAN2 Series AC-DC POWER SUPPLY

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

SPARKLE POWER INC. FSP096/135-AxAN2 Series AC-DC POWER SUPPLY

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

Environmental. Electrical Specifications at 25 O C E Output Constant Current

ATX-3000 Product Specification Enhance Electronics Co.,LTD

SPECIFICATION M/N: MPD-F For SWITCHING POWER SUPPLY

PRODUCT SPECIFICATION

Environmental. Electrical Specifications at 25 O C E Output Constant Current

Typical Efficiency (2) 0 ~ 12.5 A 150 W 90.0% EUV-150S012DTA(STA) 0 ~ 6.25 A 150 W 90.5% EUV-150S024DTA(STA) (4)

Parameter Condition Min. Typ. Max. Internal Input Filter. nom. Vin = 230VDC 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

IS-900R2UPD8G. Redundant Power Supply. Active PFC 900W + 900W. 80+ Gold Efficiency SPECIFICATION. Revision: 1.0

CPS Industrial Power Supply

Universal input VAC <250mW No load power consumption -25 C to +80 C Operating temperature, with derating

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

IEC/EN/UL60950 & CE certified, EN55032 Class B

SPECIFICATION FOR APPROVAL AC/DC ADAPTOR

SPARKLE POWER INC. FSP096/135-AxBN2 Series AC-DC POWER SUPPLY

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Universal input VAC <150mW No load power consumption

350A Series MDS 350 A D 701 A A. Technical Datasheet Medical ATX Power Supply ATX 12V 1U Power Supply

Over voltage protection: Output shutdown (V1 only) Weight: 730g

SPARKLE POWER INC. FSP050/065-DxAN3 Series AC-DC POWER SUPPLY

12W AC/DC interchangeable Adapter MU012-HA Series

SPARKLE POWER INC. FSP090-AxAN3 Series AC-DC POWER SUPPLY

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK

SPARKLE POWER INC. FSP096/120-AxAN3 Series AC-DC POWER SUPPLY

Transcription:

ADAPTER SERIES SST-AD60-C Compact, intelligent multi-voltage 60W USB Type-C adapter Maximum 60W 3A fast charging for USB Type-C equipped laptops, tablets, and mobile phones Intelligent detection and auto adjust to various DC voltage output of 20V / 15V / 12V / 9V / 5V 25mm thick compact and slim design for easy transport Up to 88% high efficiency Meets DoE level 6 standard for energy efficiency Multiple protection circuitry and safety certification

SPECIFICATION Adapter Series AD60-C 60W USB Type-C AC-DC Adapter 1. Input Characteristics: 1.1 Rated Input Voltage: 100Vac~240Vac 1.2 Input Voltage Range: 90Vac to 264Vac 1.3 Input Frequency Range: 47Hz to 63Hz ( ± 1Hz ) 1.4 Input Current: 100Vac, 240Vac / 3A load 2A 1.5 Efficiency: (Warm up 10minutes later) 5Vdc / 3A load 9Vdc / 3A load 12Vdc / 3A load 15Vdc / 3A load 20Vdc / 3A load 1.6 Power Saving: 115Vac, 230Vac / 5Vdc_0A load 0.1W 79% 84% 85% 85% 86% ( DC Cable 800 mm,18awg) 1.7 Inrush Current: 100Vac, 240Vac / 3A load Shall be less than the rating of adapter critical component (including rectifiers, fuse surge and current limiting device) 1.8 DOE(Level VI): (1)115Vac / 0A load (2)115Vac / 25%,50%,75%,100% load (Average Active Mode Efficiency,Warm up 30 minutes later) 5Vdc 0.1W 5Vdc 81.39%, 9Vdc 86.62%, 12Vdc 87.4%, 15Vdc 87.73%, 20Vdc 88% ( DC Cable 800 mm,18awg) 01

2. Output Characteristics: 2.1 Output Rated Voltage: 5V/9V/12V/15V/20V 2.2 Output Current: at constant voltage mode 5V/3A 9V/3A 12V/3A 15V/3A 20V/3A 2.3 Output Voltage Setting: at the output end of DC cable 5V±5% 9V±5% 12V±5% 15V±5% 20V±5% ( DC CABLE 800 MM,18AWG) 2.4 Output Voltage Ripple and Noise: (0.1uF Ceramic Cap. and 35V 47uF Aluminum Cap. Paralleled between the end of output cable) 100Vac, 240Vac / 0A~3A load 200mVp-p 2.5 Turn-On Delay Time: At 100Vac / 3A load, output voltage shall remain regulation 2.6 Hold Up Time: At 100Vac or 240Vac / 3A load, output voltage shall remain regulation 3Sec 5ms 2.7 Rise Time: At 100Vac / 3A load, DC output rise 275ms time from 5V to 9V 5V to 12V 5V to 15V 5V to 20V 2.8Fall Time At 100Vac / 3A load, DC output fall time from 9V to 5V 12V to 5V 15V to 5V 20V to 5V 275ms 2.9 Dynamic Load Change: (1) Output load step is: 1 0 % ~50 % 2 50 %~100 % 5V ± 15% 9V ± 15% 12V ± 15% (2) S/R=0.5A/us 15V ± 15% (3) Frequency is 100Hz and 1KHz 20V ± 15% 3.0 Overshoot: 100Vac, 240Vac / 0A and 3A load 5V ± 10% 02

3. Protection Characteristics: 3.1 Short Circuit Protection: When an internal fault occurs, or an external fault Shutdown and no damage is applied to the power supply, such that an overload or short circuit is applied to the output, the power supply shall shut down and enter auto-recovery mode. 3.2 Over Voltage Protection: The adapter will enter into shut down that means Shutdown and no damage no output while over voltage happened at output terminal that caused by internal fault, the output trip voltage shall not exceed 27 volts. That will be return to normal state by AC reset. 3.3 Over Power Protection: When an internal fault occurs, or an external fault is applied to the power supply, such that an overload or short circuit is applied to the output, the power supply shall shut down and enter auto-recovery mode. Shutdown and no damage 3.4 Over Temperature Protection: The power supply will enter into shut down while No fire, no smoke the abnormal thermal rise occurs. That will be return to normal state by AC reset. 3.5 Over Current Protection: 115Vac, 230Vac / Full load Output current limit : 4A(MAX) for 5Vdc / 9Vdc 12Vdc / 15Vdc / 20Vdc 03

4. Environmental Characteristics: 4.1 Electric Fast Transients: Refer to IEC61000-4-4 Impulse: 1kV applied to L,N Normal operation shall be continued 4.2 Lightning Surge: Refer to IEC61000-4-5 1kV applied differential mode Normal operation shall be continued Normal operation shall be continued 2kV applied common mode 4.3 Electron Static Discharge: (Refer to IEC61000-4-2 Energy Storage Capacitor 150pF; Discharge Resistor 330 ) Air Discharge: 8 KV Contact Discharge: 4 KV Normal operation shall be continued 4.4 Cooling: Natural air cooling 4.5 EMI: Adapter comply with the following national standards: EMI Conducted Emission EMI Radiated Emission 1.Full Load 2. The power supply with internal filter can meet. FCC PART 15J CLASS B CISPR22 EN55022 CLASS B VCCI LEVEL Π 4.6 Safety conforming: 4.6.1 Department of Energy DOE Regulated by customer Comply with DOE standard 4.7 LEAKAGE CURRENT: 264Vac / 50Hz 0.25mA 4.8 Dielectric Strength: (Hi-Pot) Between AC input and secondary applied AC 1.5KV / test time 1 minute / cut off current shall be less than 10mA 4.9 Temperature: Operating Storage 4.10 Humidity: Operating Storage 0 to 40 C -20 to +80 C 20% ~ 80% 10% ~ 90% 04

5. Mechanical Characteristics: 5.1 Dimension (Length x Width x Height): 92 X 77.3 X 25.4 mm 5.2 Adapter weight: 230g (typical) 5.3 Input AC socket Type: IEC 320-C14 Type 5.4 Vibration Test: (1)Non-operating, 0.01g 2 /Hz at 5Hz slopping to 0.02g 2 /Hz at 20Hz, And maintain 0.02g 2 /Hz from 20Hz ~ 500Hz (2)PSD=3.13grms, 15 minutes/axis (3)Vibration duration:15minutes (4)Vibration waveform:random (5)Force Direction X,Y,Z 5.5 Acoustic Noise: (1)Position the microphone 30 centimeters above the x-y center of the AC adapter (2)Input voltage:110vac/60hz 220Vac/50Hz Normal operation shall be continued. The EUT < 30dB This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions: (1) this device may not cause harmful interference,and (2) this device must accept any interference receivcd, including interference that may cause undesired operation. 05

NO. G11232611