Evolution Variable Output. With Override Pot. Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL 35033

Similar documents
I/O Expansion Box Installation & Operator s Instruction Manual

OZONE SWITCH Model OS-6. OS-6 Features

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)

CA-A480-A Elevator Controller. Reference & Installation Manual

AirTest Model CN9000 Series Sensor Controller

MICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., SUITE B-1, TEMECULA, CA PHONE (951) FAX

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

MICRO GROW GREENHOUSE SYSTEMS, INC

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Digital Lighting Systems, Inc.

TB-24P/24R/16P8R. Relay Outputs or Isolated Inputs Terminal Board Series

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

EAS DIGITAL/ANALOG OVERRIDE INTERFACE Model 988 PC Software version 1.06

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

MICRO GROW GREENHOUSE SYSTEMS, INC

2-Way Wireless I/O Expander Installation Guide

Resolver to Digital Expansion Board

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual

ACLD Channel Opto-isolated Digital Input Board

Grundfos MAGNA, GENI Module

AEXX SERIES MULTI-FUNCTION CLOCK/TIMERS

Plus-X AC-8. User Guide

ES-600 Ozone Controller Operation Manual

User's Guide. Model High Precision Quad Output DC Power Supply

SP6R Level Controller Operation Manual

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

Profibus DP Expansion Board

Card Nest Universal 12 position card nest for all K-AB cards above and all other K-AB cards.

ICM 400. Three Phase Voltage Monitor with Reset Switch. Low cost line voltage protection for 3-phase motor systems

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

Operating instructions AC010S Compact AS-i E-STOP safety module

SX2200 Series INSTALLATION INSTRUCTIONS. Electronic Systems Protection, Inc 8001 Knightdale Blvd. Suite 121 Knightdale NC 27545

FNet Repeater Installation & Operator s Instruction Manual

Digital Lighting Systems, Inc. CD400-DMX DMX512 Four Channel Dimmer and Switch module

OPERATING INSTRUCTIONS

SOLARIMMERSION IV Advanced Installation Manual v1.9

MCR 808LX RELAY MANAGEMENT MODULE

Digital Lighting Systems, Inc.

M1000 INTELLIGENT ZONE CONTROL SYSTEM

MSD Three Stage Delay Timer PN 7760

700 Series 200 Amp Clamp Meters

KBMG MULTI-SPEED BOARD

THERM-O-FLOW EC-20/40 Timer

Differential Liquid/Gas Pressure Transmitter

Suretrol Manufacturing Inc. MA052X-2. Kiln Controller User's Manual

BrewTroller Phoenix. Owners Manual. Updated - March 14, 2016 BREWTROLLER PHOENIX 1

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

INSTRUCTION MANUAL IM253 R0. AquaStart COMBINATION SOFT STARTERS START-UP MANUAL

Z-Wave Certified Wireless Lighting Control. Auxiliary Switch ZW2001 ZW2002 rev. 09/01/11

LPG STM 94442A User s Manual

TB-100 ControLynx Terminal Block

Installation & Operation

TX ph/mv Transmitter/Controller

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console. ECM Motors. ACC1-25 (Part # ) Revision:

FLAP indicator. Installation manual Version 1.10

FA-2448 SIX POSITION Filter Wheel

Chore-Tronics Mobile Server

Flex-Flo Control Unit

VSD-1MC MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override

Vocia ELD-1. Operation Manual

RLD-7.2 Two Channel Light Dimmer. (P/N: P-RLD-72 Digital) User & Installation Manual

LevCon. Liquid Level Indicator / Controller DIAL-SJE ( )

Vocia. Page Active Relay Module (PARM-1) Operation Manual

Wallstations for use with Grafik 3000 and 4000 Series Systems

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

MR52 READER INTERFACE

DCM Digital Control Modules

Digital Lighting Systems, Inc. PD405-DMX. Four Channel Dimmer and Switch Packs. DMX512 compatible. PD405-DMX-24DC DMX512 4 x 5 Amps Dimmer Pack

IOX-4. Installation Instructions. AXS-100 I/O Expander 1. INTRODUCTION 2. SPECIFICATIONS 3. MOUNTING DE6314 1

Data Reporter. Installation-Operation E rev.f

RB24 Relay Box Installation Guide For use in low voltage motorized window and skylight systems

Innovative Circuit Technology Ltd.

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1

VELOCICALC Air Velocity Meter

Digital Timer Outlet Model No.: EDT-1USA. Questions or Concerns? (855)

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

Meso LED Driver stands for an extremely flexible LED Driver, designed for fast and easy configuration.

Pure Sinewave Inverter

SINGLE READER EXPANSION MODULE

THE CTB08D LIGHT CONTOLLER

Adjustable Timing Control PN 8680

ABB Drives. User s Manual I/O Module Adapter AIMA-01

PSI DITHERLESS BIAS CONTROLLER USER GUIDE

zpen-1080p Features zpen-1080p Layout

Sonic Ruptor 400. User Manual

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

MP3 Speaker USER GUIDE

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

Transcription:

Evolution Variable Output With Override Pot, Inc. 1733 Co Rd 68 PO Box 99 Bremen, AL 3033 Part No. 4801318 Rev 703 Owners Manual Evolution Variable Output

Table of Contents Section Title Page 1. Warranty...3 2. Warnings...3 3. Introduction...4 4. Specifications...4 4.1 Part Numbers and Electrical Ratings...4 4.2 Features...4. Front Panel Features... 6. Initial Setup of Variable Output Control Board ()...6 6.1 AC Supply Connections...6 6.2 Time Clock Connections (Time Signal or Dry Contact Switch)...6 6.3 Evolution Connections...6 6.4 Variable Out Connections...6 6. Status LED...6 6.6 Sunrise Pot (Light Control Only)...6 6.7 Variable Curves Jumpers...6 6.8 Board Layout and Setting Locations...7 7. Wiring Connections...8 7.1 To Evolution 3000/3001 Wiring Connections...8 7.2 To Farm Hand Stage Master Wiring Connections...9 7.3 To Time Clock or Switch (StandAlone) Wiring Connections...10 7.4 Separating Circuits to Operate Different Equipment...11 8. Replacement Parts...12 Part No. 4801318 Rev 703 Table of Contents Evolution Variable Output

1. Warranty All products are warranted to be free from defects in material and workmanship for a period of one year from the date of purchase if installed and used in strict accordance with the installation instructions. Liability is limited to the sale price of any products proved to be defective or, at manufacturers option, to the replacement of such products upon their return. No products are to be returned to the manufacturer, until there is an inspection and/or a returngoods authorization (RGA) number is issued. All complaints should be directed first to the authorized distributor who sold the product. If satisfaction is not obtained or the name of the distributor is not known, write the manufacturer that appears below, directed to the attention of Customer Service Manager. This limited warranty is expressly in lieu of any and all representations and warranties expressed or implied, including any implied warranty of merchantability or fitness for a particular purpose. The remedy set forth in this limited warranty shall be the exclusive remedy available to any person. No person has authority to bind the manufacturer to any representation or warranty other than this limited warranty. The manufacturer shall not be liable for any consequential damages resulting from the use of our products or caused by any defect, failure or malfunction of our products. (Some areas do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.) This warranty gives you specific legal rights and you may also have other rights that vary from area to area. Warrantor: 2. Warnings HiredHand, Inc. 1733 Co. Rd. 68 PO Box 99 Bremen, AL 3033! WARNING Wiring And Connections Must Comply With All National And Local Electrical Codes. Installation By Qualified Electrician Required!! WARNING Disconnect All Electrical Power Sources To Evolution 3000/3001 Controller Or Farm Hand Stage Master Controller Before Installing! Part No. 4801318 Rev 703 Evolution Variable Output Page 3 of 12

3. Introduction The Evolution Variable Output models with Override Pot are HiredHand's latest addition to the electronic controller product line. These additional models have the same operational features as the previous models except the latest models contain the Intensity Control Pot. This Intensity Control Pot allows additional functionality over the previous versions, including the ability to override the main control system or the ability to use these units in conjunction with more primitive systems such as 24 hour time clocks for lights or thermostats for fans. The Evolution Variable Output w/override Pot is available in two versions: The 4KW/4HP model and the 8KW/8HP model. The Evolution Variable Output models can be used in conjunction with Evolution 3000/3001 Control Systems, Farm Hand Control Systems (Stage Master, etc.), 24 hour Time Clocks as a standalone unit, or to any dry contact control output for variable operation of lights or fans. 4. Specifications 4.1 Part Numbers and Electrical Ratings Part No. Model No. Outputs 66078033 w/override Pot 4KW / 4HP 2 66078034 w/override Pot 8KW / 8HP 4 DEVICE RATINGS Input Max Current (A) 1 A @ 1 VAC Fused At 1 A Outputs for Each Circuit 2 KW @ 1 VAC Fused @ A 2 h.p. @ 240 VAC Fused @ A 4.2 Features 4KW / 4HP 1 Intensity Control Pot (Controls the two output devices) 2 Manual Override Switches (3 positions: Variable Off On) w/override Pot 4 KW 4 HP 8KW / 8HP 1 Intensity Control Pot (Controls the four output devices) 4 Manual Override Switches (3 positions: Variable Off On) w/override Pot 8 KW 8 HP Intensity Control Pot Two Manual Override Switches Four Manual Override Switches Part No. 4801318 Rev 703 Evolution Variable Output Page 4 of 12

. Front Panel Features Evolution Variable Output () is used to vary the speed of fans or to vary light luminosity. To control the output, connect to a Evolution 3000/3001 controller or to a Farm Hand Stage Master Controller. See wiring diagrams for proper connections. The models with manual control can also work as a standalone unit with a customer supplied 24 hour time signal, timer clock, thermostat, or any other dry contact device. Manual Override Switch Variable allows light dimming or fan speed control. Off completely disables item operation. ON manually connects full AC power to equipment. Intensity / Speed Control Pot Allows user to vary the light intensity or fan speed depending on installation. AUTO 8 KW / 8 HP w/override Pot Model Shown NOTE: Operation is the same for the 4 KW / HP model. NOTE: While the knob is in AUTO position, control of the lights or fans is returned to the main control system (ex. Evolution 3000). If the unit is not connected to a control system, i.e. standalone operation, this would simply turn the equipment OFF. Part No. 4801318 Rev 703 Evolution Variable Output Page of 12

6. Initial Setup of Variable Output Control Board () The following subsections describe the usage and settings of each connection, jumper, and switch included on the PCB #174. The board layout with wiring/setting location references are shown in Section 6.8. 6.1 AC Supply Connections Always connect to a 1 VAC Power Supply. DO NOT connect any other voltage except 1 VAC. DANGER: 1 VAC is present when power is applied. DISCONNECT POWER prior to setup or maintenance. 6.2 Time Clock Connections (Time Signal or Dry Contact Switch) This connection must be used when an Electronic Controller (Evolution 3000/3001 or Stage Master) is NOT connected. The switch can be any normally open dry contact, such as a thermostat or a relay output from another control system. DANGER: 1 VAC is present when power is applied. DISCONNECT POWER prior to setup or maintenance. 6.3 Evolution Connections The Evolution connections must be wired to the electronic controller (Evolution 3000/3001 or Stage Master) unless an electronic controller is not used. Observe polarity connections ( to ; to ) when an electronic controller is used. This connection is not used if a 24 hour Time Signal or Dry Contact Switch is connected to the Time Clock connections. See wiring diagrams for more specific information. 6.4 Variable Out Connections The Variable Out connection is FACTORY WIRED to PCB #172. ( w/override Pot models only.) 6. Status LED GREEN Indicates the Power Supply is OK. ORANGE Flashing Indicates HeartBeat ; The PCB is functional. 6.6 Sunrise Pot (Light Control Only) The Sunrise Pot is used to allow the lights to gradually come ON when a 24 hour timer or dry contact switch is closed. The Sunrise Pot is for lights only and will function only in a standalone application with a normally open timer or dry contact switch connected. See wiring diagrams for more specific information. NOTE: The timer or dry contact switch for a standalone application is not included with the Variable Output unit. The Sunrise Pot allows settings from 0 to 30 minutes. If 0 is selected, the lights will turn ON immediately when the timer/contact switch is closed. If any other interval is selected, the lights will take the selected amount of minutes to go from low intensity to full light intensity after the contact is closed. 6.7 Variable Curves Jumpers The Variable Curve jumpers are for selecting the light setting or fan motor curves. The jumper must be placed in the appropriate position based on the equipment being varied. See Curve and Condition Table below for each jumper setting and description. Curve Condition For use with incandescent light bulbs. This curve is optimized for use with HiredHand s line of Funnel Flow that are 24 or less. Also, the line voltage must be Single Phase. This curve lends itself better to operation of 36 fans. The power distributed at each percentage is somewhat greater than that of curve 0. Therefore, the speed will be a little greater than that of Curve 0. This curve is for 3phase systems. Its purpose is to shift the voltage curve to give a much higher power from the varied phase. Conditions that would warrant the use of this curve is a variable speed fan that varies a great deal from 100% speed to 9% speed. Part No. 4801318 Rev 703 Evolution Variable Output Page 6 of 12

6.8 Board Layout and Setting Locations SUNRISE POT See Section 6.6. Copyright 03 Rev A! DANGER 1 VAC is present when power is applied. DISCONNECT POWER prior to setup or maintenance. Evolution Variable Output O SUNRISE 1 MINUTES 2 30 Evolution Connections See Section 6.3. Variable Out Connections See Section 6.4 Variable Curves Jumpers See Section 6.7. See Section 6.. Time Clock Connections See Section 6.2. AC Supply Connections See Section 6.1. Part No. 4801318 Rev 703 Evolution Variable Output Page 7 of 12

N.C. N.C. N.O. IN OUT IN Auxilliary Alarm DC Power Supply Close Close Open Close Open Close Open Close Open Open Close Open Close Aux. Com. Aux. Com. 12V U1 U1 U2 U2 AUX Com AUX AUX AUX 12V U1 U1 U2 U2 Auxilliary Inputs Relay Control Tunnel Aux. Input Vent Aux. Input Relay Control Var #1 Var #2 Natural Ventilation Module Power Ventilation Module Variable Module HHNet Termination Black Shield Black Shield Black Shield Black Shield Black Shield Black Shield Black Shield Black Shield Black Shield Sensor #1 Sensor #2 Sensor #3 Sensor #4 Sensor # Sensor #6 Sensor #7 Sensor #8 Outside L1 L2 AC Supply 12V GND Shield Local Network SUNRISE 1 O MINUTES 2 30 FA N0 FA N1 FA N2 7. Wiring Connections 7.1 To Evolution 3000/3001 Wiring Connections To control the output using an Evolution 3000/3001 controller, connect using the wiring diagrams below for proper connections. Evolution 3000 PCB 169 11 V 230 V N.O. OUT 12V V Com Close Temperature Sensors Copyright 03 Rev A O SUNRISE 1 MINUTES 2 30! DANGER 1 VAC is present when power is applied. Disconnect power prior to setup or maintenance. Temperature Sensors EVOLUTION PCB 169 VAR #1 VAR #2 Variable Module Gnd L2 1 VAC POWER SUPPLY L1 IMPORTANT NOTE: 1 VAC Power ONLY! NOTE: Either VAR #1 or VAR #2 may be used. Copyright 03 Rev A Circuit 1 Circuit 2 RED RED RED Circuit 3 Circuit 4 L1 OUT L1 IN L2 OR Breaker Panel Part No. 4801318 Rev 703 Evolution Variable Output Page 8 of 12

SUNRISE 1 2 O MINUTES 30 Black \Shield gnd L1 L2 AC Power # 1 gnd HI LO 12V HH Net Gnd Sig 12 Pressure V fan xt 1 V fan xt 2 V FAN IN V FAN OUT 7.2 To Farm Hand Stage Master Wiring Connections To control the output using a Farm Hand Stage Master controller, connect using the wiring diagrams below for proper connections. STAGE MASTER PCB 10 STAGE MASTER PCB 10 V Fan xt 1 V Fan xt 2 NOTE: Either V Fan xt1 or V Fan xt2 may be used. SENSORS 1 2 3 4 #1 #2 #1 #2 STAGES IN 34 6 7 8 9 101112 Copyright 03 Rev A O SUNRISE 1 MINUTES 2 30! DANGER 1 VAC is present when power is applied. Disconnect power prior to setup or maintenance. Gnd L2 1 VAC POWER SUPPLY L1 IMPORTANT NOTE: 1 VAC Power ONLY! Copyright 03 Rev A Circuit 1 Circuit 2 RED RED RED ACVARIABLE OUTPUT EVOLUTION FARM HAND ACVARIABLE OUTPUT EVOLUTION FARM HAND Circuit 3 Circuit 4 L1 OUT L1 IN L2 OR Breaker Panel Part No. 4801318 Rev 703 Evolution Variable Output Page 9 of 12

SUNRISE 1 2 O MINUTES 30 7.3 To Time Clock or Switch (StandAlone) Wiring Connections To control the output using a 24 hour timer or dry contact normally open contact switch (stand alone application), connect using the wiring diagrams below for proper connections. 24 Hour Time Signal with N.O. Contact NOTE: This can be any normally open dry contact, such as a thermostat or a relay output from another control system. Copyright 03 Rev A O SUNRISE 1 MINUTES! DANGER 1 VAC is present when power is applied. Disconnect power prior to setup or maintenance. 2 30 Gnd L2 1 VAC POWER SUPPLY L1 IMPORTANT NOTE: 1 VAC Power ONLY! Copyright 03 Rev A Circuit 1 Circuit 2 RED RED RED Circuit 3 Circuit 4 L1 OUT L1 IN L2 OR Breaker Panel Part No. 4801318 Rev 703 Evolution Variable Output Page 10 of 12

N.C. N.C. N.O. N.O. IN OUT IN OUT Auxilliary Alarm 12V V DC Power Supply Close Close Open Close Open Close Open Close Open Open Close Open Close Aux. Com. Aux. Com. 12V U1 U1 U2 U2 AUX Com AUX AUX AUX 12V U1 U1 U2 U2 Auxilliary Inputs Relay Control Tunnel Aux. Input Vent Aux. Input Relay Control Var #1 Var #2 Natural Ventilation Module Power Ventilation Module Variable Module HHNet Termination Black Black Black Black Black Black Shield Shield Black Shield Shield Black Shield Shie ld Black Shie ld Shield Shield Sensor #1 Sensor #2 Sensor #3 Sensor #4 Sensor # Sensor #6 Sensor #7 Sensor #8 Outside L1 L2 AC Supply 12V GND Shield Local Network 7.4 Separating Circuits to Operate Different Equipment In some cases, you may want to operate a combination of lights and fans. This may be accomplished but only one can be operated using the manual override pot. The following is an example of how one would wire two circuits for lights and then two circuits for fans while integrated into the Evolution 3000. NOTE: In this example, Manual Override using the Intensity Control Pot is only associated with the light circuit. Evolution 3000/3001 PCB 169 EVOLUTION PCB 169 NOTE: Either VAR #1 or VAR #2 may be used. VAR #1 VAR #2 Variable Module 11 V 230 V EXAMPLE CIRCUIT Com Close Tem perature Sensors Temperature Sensors Circuit 1 Circuit 2 RED Copyright 03 Rev A O SUNRISE 1 MINUTES! DANGER 1 VAC is present when power is applied. Disconnect power prior to setup or maintenance. 2 30 RED FACTORY WIRED CONNECTION RED RED IMPORTANT NOTE: 1 VAC Power ONLY! Gnd 1 VAC L2 POWER L1 SUPPLY Circuit 3 Circuit 4 Connection Example Connection Example L1 OUT L1 IN Breaker Panel L2 (2 kw Max. @ 1 VAC) (2 h.p. Max. @ 240 VAC) L2 Breaker Panel L1 IN L1 OUT Part No. 4801318 Rev 703 Evolution Variable Output Page 11 of 12

8. Replacement Parts Part No. Description 6407136 / w/qa 3010240 Fuse A Time Delay 30012869 Switch SPDT 2 HP w/tabs 6407138 / Dimmer M/A w/qa Part No. 4801318 Rev 703 Evolution Variable Output Page 12 of 12