Installing Cisco RP-Series PDUs

Similar documents
G5 PDU Installation Guide

Power Supply and Fan Module Installation

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Power Supply Installation

Panduit Basic Rack PDU

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

HPE Intelligent Power Distribution Unit Installation Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Installing a Power Supply

Panduit Basic Rack PDU with Local Meter

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Installation Job Aid for Ethernet Routing Switch 5900 Series

Installing the Cisco SFS 3504 Server Switch

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

Cisco CRS 16-Slot Chassis Power Systems

IBM. Rack Installation Instructions

Rack Installation Instructions

* * Agilent Power Distribution Unit (PDU) Installation Guide

InnoMedia Business VoIP ATA Models

Installing the PSU for the S50 and S50N

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

Installing the Cisco MDS 9020 Fabric Switch

Preparing to Install the VG248

ETERNUS DX80 S2 and DX90 S2. Hardware Installation

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications

Replacing the Power Supply

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Vertiv Local Rack Access 18.5" LED LCD Console

Installation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules

Cisco TelePresence VX Clinical Assistant TM

Installation Job Aid for Ethernet Routing Switch 3600 Series

PACSystems* RX3i IC695ACC650

Raritan PXE. Quick Setup Guide. Safety Precautions. Before You Begin. Mounting the PXE. Unpacking the PXE. Zero U Size. 1U Size

Horizontal PM PDUs. Vertical PM PDUs

Connecting Power and Ground

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

QUICK SETUP GUIDE. Raritan PXE. Safety Precautions. Before You Begin. Mounting the PDU. Unpacking the PXE. 1U Size

Instruction Manual Basic Rack PDU VP7541 and VP9571A

Rack Installation Instructions

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY.

Arion PDU : Intelligent Power Distribution User Guide for 24xC13 Outlet Monitored PDU

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x

Handset Charging Rack OpenStage WL 3 / OpenStage WL3 Plus. Installation Guide A31003-M2000-J

Vertiv VR Rack 1.0 GENERAL

SmartZone Gateway- Enabled M Series Rack PDU

hp uninterruptible power system r12000 xr models installation instructions

Switched Rack Power Distribution Unit

QuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions

16Hi HARDWARE INSTALLATION GUIDE

INSTALLATION GUIDE. AXIS 291 1U Video Server Rack ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL

Note: All of PXC data is available on the PX3 support page. Simply visit Support page > Choose a Product > select "PX3." QS Rule.

EATON Transformer Module

Three Phase Systems-International PC302-I/MTD

Solutions Guide for Cisco UCS B and C Series Servers

Installation Job Aid for VSP 4850GTS

Best Practices Guide. EMC VMAX3 Family. Best Practices Guide for AC Power Connections REVISION 2.0. August, 2015

Rack Mount Power Supplies

1. Unpacking the System

QUICK SETUP GUIDE. Raritan PX3 and PX2. Safety Precautions. Before You Begin. Unpacking the PX2/PX3. Zero U Size. 1U and 2U Size

Installation Job Aid for VSP 4450GTX-HT- PWR+

Basic PDU Modules SW Meter PDU SW Meter Switch PDU SW Three Phase PDU. How to install 11-12

BIPOLAR OPERATIONAL POWER SUPPLY

Liebert MicroPOD 230V

Installing Power Modules

Technical Specifications

HAW-SIBU. Rack Installation Guide. Version 1.0.1

Quick Start Guide S X. 1. Unpacking the Switch. 2. Identifying Your System. Front View

Quick Start Guide. C-100 Series Switches

Broadband Automatic Disconnect Switch. User Manual

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY I INTRODUCTION

BCM2 Series Branch Circuit Monitors Quick Setup Guide

E1135C PDU and Pod Upgrade Procedure

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

Three Phase Residential Solution for Australia, System Design and Installation Guidelines

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Site Preparation CHAPTER

Chassis Overview. About the Cisco NCS 4016 Chassis. This chapter provides an overview of the Cisco NCS 4016 chassis and components.

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

Instruction Manual. Rack PDU XP Series. geistglobal.com

QuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions

Safety Precautions Legrand PDU. 0U PDU Overview. Outlets. Circuits. Controller with Connector Ports: See Controller (on page 4).

Innovative Circuit Technology Ltd.

FP-PS-4. Features. Installation

Rack Installation Instructions

PRELIMINARY. CR Series. Ceiling Rack Systems with AmbiTILT Equipment Loading

Introduction. Overview

PDU Branch Current Monitoring Board Installation and Configuration

Cisco CRS-1 Carrier Routing System

Netfinity White Paper Netfinity Technology Center

LCD Drawer User Manual

INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000

Preparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Complete power quality solutions for server rooms and data centres. Pre-packaged data centre solutions

Installation Notes and Warnings for the Cisco UCS 5108 Server. The following notes and warnings apply to all installation tasks:

Transcription:

This chapter contains the following sections: Preparing to Install an RP-Series PDU, page 1 Installing a Zero-U PDU, page 1 Installing a 1RU or 2RU PDU, page 7 Preparing to Install an RP-Series PDU Before you install a PDU, plan how to route the power cable. It can be routed through the bottom of the Cisco R42612 rack, through the two knockout cabling portholes on the top enclosure of the rack, or through the large opening with brushes at the rear of the top enclosure of the rack. Installing a Zero-U PDU There are five models of PDUs that can be mounted vertically in a Cisco R42612 Rack. These PDUs can be installed on the PDU trays on both sides of the rack; the PDUs do no require any RU space, so they are also referred to a zero-u PDUs. Note The Cisco R42612 rack can accommodate up to six zero-u PDUs. When servicing Cisco UCS servers, some products may require the temporary removal of cables to provide service space for rear-facing field replaceable units (FRUs). For additional information on how to install a PDU, see the Eaton epdu G3 Installation and Connectivity Quick Start or the Eaton Enclosure Power Distribution Unit (epdu) G3 - Operations Manual. The following table provides descriptions for these PDUs. For detailed specifications and illustrations, see PDU Specifications. 1

Installing a Zero-U PDU Table 1: Zero-RU PDU Descriptions Product ID Description Plug Country RP208-30M1P-6-36 30 A, metered input, single-phase, vertical-mount PDU with 6 C19 and 36 C13 connectors L6-30P North America RP208-30M3P-6-30 30 A, metered input, three-phase, vertical-mount PDU with 6 C19 and 30 C13 connectors L15-30P North America RP208-60M3P-12-9 60 A, metered input, three-phase, vertical-mount PDU with 12 C19 and 9 C13 connectors IEC60309 460P9 North America RP230-32M1P-6-36 32 A, metered input, single-phase, button-mount (rear and sides) PDU with 6 C19 and 36 C13 connectors IEC60309 332P6 International RP230-32M3P-12-12 32 A, metered input, three-phase, button-mount (rear and sides) PDU with 12 C19 and 12 C13 connectors IEC60309 532P6 International Note The RP208-60M3P-12-9 PDU must be installed in the rear facing locations as shown in Figure 5: One Zero-U PDU Installed on the Rear-Facing Flange, on page 7. The increased size of this PDU requires the rear-facing installation to avoid interference with equipment and cabling. Statement 1073 No User-Serviceable Parts No user-serviceable parts inside. Do not open. Statement 1004 Installation Instructions Read the installation instructions before connecting the system to the power source. Statement 1005 Circuit Breaker This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 2

Installing a Zero-U PDU Statement 1024 Ground Conductor This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 328 Main Ground Connection For Nordic countries (Norway, Finland, Sweden and Denmark) this system must be installed in a Restricted Access Location, where the voltage of the main ground connection of all equipment is the same (equipotential earth) and the system is connected to a grounded electrical outlet. Statement 25 for Norway and Sweden Connect the device to a grounded power outlet. You can install up to six zero-u PDUs in the Cisco R42612 Rack. When servicing UCS servers, some products may require temporary removal of cables to provide service space for rear-facing field replaceable units (FRUs). Due to height restrictions, RP208-60M3P-12-9 must be installed facing the rear of the rack. Each PDU needs a PDU retention bracket attached to the top of the PDU. When secured to the PDU tray, the PDU retention bracket ensures that each PDU is securely held in place. With the rear of the rack open, follow these steps to install a zero-u PDU: 3

Installing a Zero-U PDU Procedure Step 1 Insert the mounting button on the back of the PDU into a key hole near the top of the PDU tray or into the top key hole of the rear-facing flange. Callout 1 in the following figure shows the mounting button and the key hole of the PDU tray on the side of the rack. Figure 1: PDU Mounting Button Step 2 Slide the PDU down slightly so that it locks into place in the key hole on the PDU tray (see callout 2 in the preceding figure) or the rear-facing flange. Step 3 Secure the lower PDU mounting button into place as in steps 1 and 2. Step 4 Install a PDU retention bracket on the top of the PDU as shown in the following figure. Secure the bracket to the PDU tray with the screws provided. Figure 2: Attaching the PDU Retention Bracket to the PDU Tray Step 5 Step 6 Route the PDU power cable either through the large access opening in the back of the rack canopy. Connect the PDU power cord to the AC power source. The following figure shows a single zero-u PDU installed in the PDU tray. 4

Installing a Zero-U PDU Figure 3: One Zero-U PDU Installed 5

Installing a Zero-U PDU The following figure shows three zero-u PDUs installed side-by-side in the PDU tray. Figure 4: Three Zero-U PDUs Installed 6

Installing a 1RU or 2RU PDU The following figure shows a single zero-u PDU installed on the rear-facing flange. Figure 5: One Zero-U PDU Installed on the Rear-Facing Flange Installing a 1RU or 2RU PDU The RP208-30M1P-4-8 PDU and the RP208-60M3P-12 PDU mount horizontally in one of the available RU spaces. For additional information on how to install a PDU, see the Eaton epdu G3 Installation and Connectivity Quick Start or the Eaton Enclosure Power Distribution Unit (epdu) G3 - Operations Manual. The following table provides the specifications for these PDUs. For detailed specifications and illustrations, see PDU Specifications. 7

Installing a 1RU or 2RU PDU Table 2: 1RU and 2RU PDU Specifications Product ID Description Plug Country RP208-30M1P-4-8 30 A, metered input, single-phase, horizontal-mount PDU with 4 C19 and 8 C13 connectors L6-30P North America RP208-60M3P-12 60 A, metered input, three-phase, horizontal mount PDU with 12 C 19 connectors IEC 60309 460P9 North America Statement 1073 No User-Serviceable Parts No user-serviceable parts inside. Do not open. Statement 1004 Installation Instructions Read the installation instructions before connecting the system to the power source. Statement 1005 Circuit Breaker This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: Statement 1024 Ground Conductor This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 328 Main Ground Connection For Nordic countries (Norway, Finland, Sweden and Denmark) this system must be installed in a Restricted Access Location, where the voltage of the main ground connection of all equipment is the same (equipotential earth) and the system is connected to a grounded electrical outlet. Statement 25 for Norway and Sweden Connect the device to a grounded power outlet. To install a 1RU or 2RU PDU, follow these steps: 8

Installing a 1RU or 2RU PDU Procedure Step 1 Step 2 Attach the four cage nuts to the interior side of the rack posts, spacing the nuts apart to the 1RU or 2RU position, depending on which PDU you are installing. Use the supplied mounting screws to secure the unit in place, as shown in the following figures. Figure 6: Mounting the RP208-30M-P-4-8 1RU PDU 9

Installing a 1RU or 2RU PDU Figure 7: Mounting the RP208-60M3P-12 2RU PDU 10