Electric Actuators and Control Systems. Established Leaders in Valve Actuation AD Instruction Manual. Publication P972E Issue 08/09

Similar documents
AD-7830 Servo Amplifier

Electric Actuators and Control Systems. Established Leaders in Valve Actuation AD-8140 & AD Instruction Manual. Publication P971E Issue 08/09

SM-1015 Digital Actuator

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Rotork Fairchild PAX1 Linear Actuator User s Manual

Service Instructions. Conductor 420

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

P216. Condenser fan speed controller. Product bulletin. Features

HART. Actuator Control. Redefining Flow Control

Proportional Control Unit (PCU)

Modbus. Serial communication and control of Rotork actuators. Established Leaders in Valve Actuation. Electric Actuators and Control Systems

P216 Series Condenser Fan Speed Controller

Resolver to Digital Expansion Board

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

Firmware Version 1.xx

Differential Liquid/Gas Pressure Transmitter

LED indicators for normal/fault operating conditions, setup mode, loss of analog signal, and solid-state motor control output.

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions

SERIES CMT CARBON MONOXIDE GAS TRANSMITTER

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

INSTALLATION AND MAINTENANCE INSTRUCTIONS For Chemline A- & Q-Series Actuator with Digital (AC) Positioner

Table of Contents 1. Overview Installation...6

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL

Power Connections: Basic Wiring:

Modbus Actuator Control

VA-7700 Series. Electric Valve Actuators. Product Bulletin

Level-Lance Model 5400A

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

SMVector Additional I/O Module Installation and Operation Manual

TPE 1464 Series Pressure Transducer

Analog Monitor Installation Manual

CDD4 Duct Carbon Dioxide Transmitter

Tempco Instruction Manual

Replacing a Precision Controller Circuit Board

Profibus DP Expansion Board

AC Tech. Variable Speed AC Motor Drives. SCN Series Installation and Operation Manual

CDD4 Series Room CO2 Transmitter Installation Instructions

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA SST7000 SST7100. Speed Switch / Transmitter

MAXIMA+ Series Rotary Level Indicator

Analog Input Installation Manual

700 SERIES DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL

ETM MD100 Drive System 1/2HP (370W) User Manual. Table of Contents. Drive Features

EZ-24 EZ-24-HTB EZ-24-HTBS. Version May Publication PR-1100

VTSC100. Transfer Switch Controller

********SERVICE MANUAL******** MODELS:

VLT 2800 DRIVE SPECIFICATIONS

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000

Master Pulse Reference/ Isolated Pulse Follower Expansion Board

MAXIMA + Series ROTARY LEVEL CONTROL

CDD Carbon Dioxide Transmitter

PS8 - II. Professional Power Sequencer. User s Manual

I ntroduction. RA Fast Running Electric Actuator. Features and Benefits

MODEL 245 / 345 High Range

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

PEAKTRONICS DHC-100 FEATURES. Digital High-Resolution Controller

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System

INSTRUCTION MANUAL IM253 R0. AquaStart COMBINATION SOFT STARTERS START-UP MANUAL

Hybrid AC Driver [GCNC-1110]

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER

User's Guide. Model W 3-in-1 Switching DC Power Supply

PowerFlex 400 AC Drive Guide Specification

V E1B Snap-in I/O Module

Shown with terminal block Supports diagnostic point fault contacts in the logic program

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

PowerFlex 40 Sample Specification

EXPRESS SETUP. PanelMate 1700 Series PanelMate Power Pro. Cutler-Hammer

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)

ASI Systems ML5740A Series

ASI Systems ML5720A Series

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

DUTY, UNIVERSAL ON/OFF & MODULATING ELECTRIC ACTUATORS

Athena Series RMC Hot Runner Controller Configuration and Operation Manual

ZC Series Zone Monitoring Controllers

TECHNICAL REFERENCE BSD V-3A Bipolar Stepper Driver

SED2 Variable Frequency Drives

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

1395 Node Adapter Board Troubleshooting

AirTest Model CN9000 Series Sensor Controller

NETRONICS HS3500 CONTROLLER

Installation, Maintenance and Operating Instructions

M-SWITCH SWITCH INPUT IN GAS CONTROL SYSTEM INSTALLATION OPERATION AND MAINTENANCE MANUAL

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT

Installation, Operation and Maintenance Manual

PG Softstarter Installation Manual for 5A, 9A and 16A Controllers

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

GS400. Electronic Auto-Ranging DIN Panel Mounted Positioner

IQM & IQML RANGE CONTROL AND MONITORING FACILITIES. Publication E420E issue 7/02

MOTOR DRIVE AMPLIFIER

BIPOLAR OPERATIONAL POWER SUPPLY

MODEL 805 USER MANUAL

MDM 011-Z1 Regen Resistor

Transcription:

Electric Actuators and Control Systems Established Leaders in Valve Actuation AD-9120 Instruction Manual Publication P972E Issue 08/09

Instruction Manual IM-0626 AD-9120 Digital Servo Amplifier Table of Contents General Information... 2 Introduction... 2 Receiving/Inspection... 2 Storage... 2 Equipment Return... 2 Abbreviations Used in This Manual... 2 General Description... 3 Actuator Compatibility... 3 Basic Models... 3 Specifications... 3 Installation Wiring... 4 Operation... 4 Set-up and Calibration... 5-6 Diagnostics... 7 Troubleshooting Guide... 8 Typical Wiring Diagrams... 9 Major Dimensions... 10-11 Due to wide variations in the terminal numbering of actuator products, actual wiring of this device should follow the print supplied with the unit.

INTRODUCTION Rotork Process Controls, designs, manufactures, and tests its products to meet many national and international standards. For these products to operate within their normal specifications, they must be properly installed and maintained. The following instructions must be followed and integrated with your safety program when installing, using, and maintaining Rotork Process Controls products: Read and save all instructions prior to installing, operating, and servicing this product. If you do not understand any of the instructions, contact your Rotork Process Controls representative for clarification. Follow all warnings, cautions, and instructions marked on, and supplied with, the product. Inform and educate personnel in the proper installation, operation, and maintenance of the product. Install equipment as specified in Rotork Process Controls installation instructions and per applicable local and national codes. Connect all products to the proper electrical sources. To ensure proper performance, use qualified personnel to install, operate, update, tune, and maintain the product. When replacement parts are required, ensure that the qualified service technician uses replacement parts specified by Rotork Process Controls. Substitutions may result in fire, electrical shock, other hazards, or improper equipment operation, and will void product warranty. Keep all product protective covers in place (except when installing, or when maintenance is being per formed by qualified personnel), to prevent electrical shock, personal injury, or damage to the actuator. WARNING - SHOCK HAZARD Installation and servicing must be performed only by qualified personnel. WARNING - ELECTROSTATIC DISCHARGE This electronic control is static-sensitive. To protect the internal components from damage, never touch the printed circuit cards without using electrostatic discharge (ESD) control procedures. RECEIVING/INSPECTION Carefully inspect for shipping damage. Damage to the shipping carton is usually a good indication that it has received rough handling. Report all damage immediately to the freight carrier and Rotork Process Controls Unpack the product and information packet taking care to save the shipping carton and packing material should return be necessary. Verify that the items on the packing list or bill of lading agree with your own. STORAGE If the product is not installed immediately, it should be stored in a clean, dry, non-corrosive environment. EQUIPMENT RETURN A Returned Goods (RG) authorization number is required to return any equipment for repair. This must be obtained from Rotork Process Controls (414/461-9200). The equipment must be shipped, freight prepaid, to the following address after the RG number is issued: Rotork Process Controls 5607 West Douglas Avenue Milwaukee, Wisconsin 53218 Attn: Service Department To facilitate quick return and handling, include: RG Number on outside of box Your Company Name, Contact Person, Phone, Fax Address Repair Purchase Order Number Brief description of the problem ABBREVIATIONS USED IN THIS MANUAL AC Alternating Current C Degrees Celsius DC Direct Current DEC Decrease DIP Dual Inline Package (switch) F Degrees Fahrenheit Hz Hertz IGBT Integrated Gate Bipolar Transistor INC Increase IPM Intelligent Power Module LED Light Emitting Diode LOS Loss of Signal ma Milliamp NC No Connection RG Return of Goods Vac Volts ac Vdc Volts dc

GENERAL DESCRIPTION The AD-9120 Digital Servo-Amplifier is designed for integral or remote mount to control appropriate Jordan Controls Actuators. A microprocessor-based control and an IGBT-based intelligent power module (IPM) is used to drive the actuator to perform highly accurate, bidirectional positioning. The Rapid Setup feature allows actuator setup using push-buttons (no potentiometers or jumpers). Self diagnostics and prompts are available through an onboard lighted display. ACTUATOR COMPATIBILITY The AD-9120 Digital Servo Amplifier can be mounted integral to all SM-5000, LA-5000 and LA-2000 Series 90 and 180 Vdc input power actuators, or installed remotely for all other 90 and 180 Vdc power actuators. BASIC MODELS AD-9120 120/208/240 Vac, single phase, 50/60 Hz input power designed for integral mounting. * AD-9120-P Same as above but plate mounted. AD-9120-R73 Same as AD-9120, but designed for remote mounting as a retrofit to the older AD-7300 Servo Amplifier. AD-9120-E Same as AD-9120-P inside a 14 x12 x6 NEMA 4 Enclosure SPECIFICATIONS Power Input: 120/208/240Vac, +/- 10%, single phase, 50/60 Hz * Power Output: Up to 90 Vdc/180 Vdc, 15 Amperes Peak Command Inputs: 4-20mA into 200 ohm shunt or 0-10 Vdc into 100k minimum impedance or 0-5 Vdc into 100k minimum impedance Position Feedback Signal: 1000 ohm potentiometer 4-20mA (optional) Position Signal Output: Loop powered, isolated, 2 wire 4-20mA signal. Shows actuator position. Other Inputs: End-of-travel limit switches (from actuator) Overtorque limits witches (from actuator) Auto/Manual switch - Selects between Automatic and Manual mode Automatic Mode: 4-20mA command input controls actuator position Manual Mode: Increase and Decrease inputs control actuator position as follows: Increase (INC)- Commands actuator to increase when in manual mode. Decrease (DEC)- Commands actuator to decrease when in manual mode. Other Outputs: Form C fault relay output Contact Rating 120 Vac, 2 Amperes Cycles On Events: Loss of 4-20mA signal Loss of position feedback signal MIN/MAX limit switch reached IPM Fault Motor stalled condition Button noise LED Indication: Power Fault Ambient Temperature Range: -40 F to 150 F (-40 C to 65 C) Approx. Weights: AD-9120-P, R73 or -R2TC: 10 lbs. AD-9120-E: 35 lbs. * 208 voltage requires a special board set. -3-

INSTALLATION WIRING Most installations locate the servo amplifier inside a Jordan Controls actuator, for ease of mounting and to protect the amplifier. This is the preferred mounting arrangement. For remote mounting, the servo amplifier and actuator should be as close to each other as possible, not exceeding 50 feet of wire lengths. Ensure all connections are correct and tight before applying power. Power, command signal, feedback signal and motor output are the minimum required connections. All wiring must be done in accordance with prevailing codes by qualified personnel. Typical wiring diagrams are shown on page 8. Due to wide variations in terminal numbering of various actuator products, actual wiring should follow the print supplied with the actuator. Over current protection compatible with motor control must be installed in line power. After installation, all conduits must be sealed to prevent water damage. All low level signal wiring must be shielded type with the shield grounded at source common. Failure to shield these terminations properly may result in inproper operation and premature failure. OPERATION Display First Character of First Line A == Automatic mode M == Manual mode S == Setup mode In automatic and manual modes, Line 1 shows position and command in percent of Span Zero range. Line 2 provides status, diagnostic or fault information. Buttons SW1 Reset clears microprocessor registers and restarts control program. Do not press during normal operation. Not required for setup. SW2 (Increase, or INC) Manual Mode: Press and hold to increase actuator position (normally Clockwise or extend) Setup Mode: Cycle through parameters to change. When SPAN, ZERO, or PRESET are selected, will increase actuator position SW3 MODE switches between Manual Mode and Setup Mode. Aborts a parameter change during setup mode SW4 ENTER in Setup Mode selects which parameter to change, then accepts the new value. SW5 (Decrease, or DEC) Manual Mode: press and hold to decrease actuator position (normally Counter-Clockwise or retract) Setup Mode: Cycle through parameters to change. When SPAN, ZERO, or PRESET are selected, will decrease actuator position. SW1 D1 POWER ISOLATED TRANSMITTER CIRCUIT BOARD SW2 INC SW3 MODE DISPLAY SW4 ENTER SW5 DEC J5 J6 J7 J4 P2 TB2 ANALOG SIGNALS TB3 TB1 D7 FAULT -4-

SETUP AND CALIBRATION 1. Place Actuator s Auto/Man switch to MAN (if supplied), or remove jumper TB3-3 from TB3-4. 2. Press MODE button on EC-10861 once to put into Setup Mode. 3. Provide the maximum command for the actuator to terminals TB2-1 (+) and TB2-2 (-) for current command, or terminals TB2-4 (+) and TB2-3 (-) for voltage command. Note: see command type setting section for more information. 4. Press ENTER to accept the maximum command calibration, or press MODE to abort the change. Span Adjustment 1. Press button until SPAN = xxxx appears on line 2 of the display. 3. Press or to move actuator to desired SPAN position. 4. Press ENTER to accept new SPAN position, or press MODE to abort changing SPAN. Zero Adjustment 1. Press or buttons until ZERO = xxxx appears on line 2 of the display. 3. Press or to move actuator to desired ZERO position. 4. Press ENTER to accept new ZERO position, or press MODE to abort changing ZERO. Deadband Adjustment Note: Suggested starting deadband value: 1.0 1. Press or buttons until DEADBAND = xx.x 3. Press or to change Deadband value. Deadband will increase or decrease by 0.1% with each press of or. 4. Press ENTER to accept new Deadband, or press MODE to abort changing Deadband. Maximum Command Calibration Note: The maximum calibration adjusts the amplifier s internal span command level to match the command given at the input terminals during this setup. 1. Press or buttons until the Max CAL = xxxx 2. Press the ENTER button. -5- Minimum Command Calibration Note: The minimum calibration adjusts the amplifier s internal zero command level to match the command given at the input terminals during this setup. 1. Press or buttons until the Min CAL = xxxx 2. Press the ENTER button. 3. Provide the minimum command for the actuator to terminals TB2-1 (+) and TB2-2 (-) for current command, or terminals TB2-4 (+) and TB2-3 (-) for voltage command. Note: see command type setting section for more information. 4. Press ENTER to accept the minimum command calibration, or press MODE to abort the change. Speed Note: Use speed 80 with SM-5480 actuators. 1. Press or buttons until SPEED = xxxx appears on line 2 of the display. 3. Press or to desired actuator run speed as a percent of maximum (maximum = 100). Each or press changes by +/-5. 4. Press ENTER to accept SPEED command calibration, or press MODE to abort changing SPEED. Input Voltage Selection Note: User must set EC-10832 to proper ac input voltage using SW1 1. Press or buttons until Input Voltage = xxx 3. Press or to change Input Voltage between 120, 208 and 240 Vac. 4. Press ENTER to accept new Input Voltage position, or press MODE to abort changing Input Voltage.

Motor Rating Selection 1. Press or buttons until Motor Rating = xxx appears on line two of the display. 3. Press or to change Motor Rating between 90 and 180 Vdc. 4. Press ENTER to accept new Motor Rating position, or press MODE to abort changing Motor Rating. Proportional Gain Constant Note: Suggested starting value: KP=4. 1. Press or buttons until KP = xx appears on line 2 of the display. 3. Press or to change KP value. Large KPs increase acceleration, while small KPs increase the proportional band and decrease oscillations around setpoint. 4. Press ENTER to accept new KP, or press MODE to abort changing KP. Command Type Calibration Note: A current command or a voltage command can be used for the control of the actuator. The appropriate type of command must be wired to the terminals, as shown in the typical wiring diagram section of this document. 1. Press or buttons until the Command = xxxxxxxx 2. Press the ENTER button. 3. Use the or buttons to toggle between Voltage and Current. 4. When the desired command type is selected press ENTER to accept the command type, or press MODE to abort the change. Loss of Signal Action Setup Note: The amplifier can either lock in place or go to a position during the loss of command signal condition. The loss of signal will go into effect when the input command is less than 2.5 % of the minimum command setting, or the input command is 10% greater than the maximum command setting. The loss of signal mode of operation is intended for the current input command, and will not work correctly for the voltage input command when the minimum command setting is less than 0.5 VDC. 1. Press or buttons until the LOS action = xxxx 2. Press the ENTER button. 3. Use the or buttons to toggle between lock and POS. Lock will cause the actuator to lock in place during a loss of signal condition. POS will cause the actuator to go to the preset position during a loss of signal condition. 4. When the desired command type is selected press ENTER to accept the loss of signal action, or press MODE to abort the change. Loss of Signal Position Setup Note: The loss of signal action must be set to position for this setting. If the loss of signal action is not set to position, the following display screens will not appear to the user. 1. Press or buttons until the LOS POS = xxxx 2. Press the ENTER button. 3. Press the or buttons to move the actuator to the desired loss of signal position. 4. Press ENTER to accept the new loss of signal position, or press MODE to abort changing the loss of signal position. Save Configuration Any parameter changes must be saved to EEPROM prior to power off. On power up, amplifier will use last saved parameters. Old parameters are lost when new parameters are saved. 1. Press or buttons until Save Parameters appears on line two of the display. 2. Press ENTER to Save Parameters, or press MODE to abort saving parameters. Setup Complete 1. Press MODE button to return to Manual mode. 2. Place Actuator s Auto/Man switch to Auto (if supplied), or place jumper TB3-3 to TB3-4. -6-

DIAGNOSTICS Diagnostics appear on line two of the display. When more than one diagnostic is active, only the highest priority will show. Fault: Increase Limit Torque Limit Switch or End of Travel Limit Switch for the increasing direction is tripped. Decrease actuator to move off limit switch. Fault: Decrease Limit Torque Limit Switch or End of Travel Limit Switch for the decreasing direction is tripped. Increase actuator to move off limit switch. Fault: IPM Power stage has over-current or overtemperature condition and has shut down. Fault: Stalled Actuator is not moving as fast as amplifier expects. Momentary stall or IPM faults are sel-resetting. Continuous or repetetive stall or IPM faults indicate an improperly loaded actuator or operation above rated duty cycle. Reduce load or duty cycle. Fault: LOS-Command Loss of command signal. Command has fallen below approximately 3.6mA, or above 21.6mA Return command signal to 4-20 ma range. Fault: LOS-Feedback Feedback pot has been disconnected, or feedback signal has risen above approximately 4.9 V. Fault: Button Noise Noise detected on buttons and/or switches. Occasional button noise has no effect on amplifier performance. excessive button noise faults indicate poor wiring or other noise. Fault: System Failure Microprocessor has detected a system failure. Reset amplifier and consult factory. Status Information During Auto or Manual Mode, line two of the display shows status information when there are no FAULTS. Press ENTER to cycle through the information. Amp Starts = xxxx Total times the amplifier has been powered up or reset. Act Starts = xxxx Total times the motor has been started since last power up. Temp. C xx Temperature in C of the amplifier (under the display). Voltage xxx Absolute value of dc motor voltage. Current +/- xx.x Motor current. IPM Faults xx The number of IPM faults that have occurred since the last power up. -7-

Troubleshooting Trouble Actuator will increase, but not decrease. LS2 is tripped Possible Cause Actuator is at ZERO (position = 0% +/- deadband) Solution Increase actuator to normal operating range. Check LS2 and ZERO setup. Actuator will decrease, but not increase. LS1 is tripped Actuator is at SPAN (position = 100% +/- deadband) Decrease actuator to normal operating range. Check LS1 and SPAN setup. Actuator will not move No actuator power Motor is not connected LS1 and LS2 are both tripped Is LED D1 on? If no, turn off power and re-check electrical connections. Connect motor as shown in wiring diagram. Verify LS1 and LS2 are set up correctly. Actuator will not move and LOS-Feedback Nothing shows on the display Position transmitter output is 0 Feedback pot is disconnected Actuator position is out of normal operating range. No power to control/logic board No power to transmitter. Check feedback pot connections Hand crank actuator to normal operation range. Is LED D1 on? Is 50 pin ribbon cable connected? Transmitter is loop powered. See wiring diagram to supply isolated power to transmitter. External wiring is bad. Transmitter is defective. Replace transmitter. Position transmitter output is >30mA Isolated loop power supply polarity is reversed. Swap transmitter power supply leads. D7 Fault LED is on A Fault has occurred. See Diagnostics on page 6. Spare Parts List 1 Driver Board 68C-038504-001 2 208 Vac Board Set 68C-038504-002 3 Interface Board 68C-038698-001 4 Ribbon Cable 25A-035285-002 5 AC Line Filter 74B-038954-003 6 Transmitter Board 68A-038691-001 -8-

Typical Wiring Diagrams With AD-9120 Integral to Actuator AD-9120 Due to wide variations in terminal numbering of actuator products, actual wiring should follow the print supplied with the unit. Notes: 1. 240 Vac input is required where actuator nameplate voltage is 180 Vdc. 2. 24 Vdc power supply is required. 3. When TB3-3 and TB3-4 are connected, actuator will run in automatic mode, which is positioning in response to input command signals. With AD-9120 Remote from Actuator AMPLIFIER IN ENCLOSURE ACTUATOR Notes: 1. 240 Vac input is required where actuator nameplate voltage is 180 Vdc. 2. For 4-20mA signal to actuator. 3. 24 Vdc power supply is required. -9-

Major Dimensions (Remote Mount) AD-9120-R Panel Style or Retro-fit for AD-7300 AD-9120-P Panel Mount -10-

Major Dimensions (Remote Mount) AD-9120-E Installed in remote enclosure NEMA 4 NOTES: 1. For use when the AD-9120 series amplifier is remotely located. 50 foot wire run maximum between amplifier and actuator. 2. Shielded wiring is required with the shield grounded at source common for all low level circuits. This includes command & feedback signals and actuator limit switches. -11-

A full listing of our worldwide sales and service network is available on our website. Electric Actuators and Control Systems UK Rotork plc tel +44 (0)1225 733200 fax +44 (0)1225 333467 email mail@rotork.com USA Rotork Process Controls tel +1 (414) 461 9200 fax +1 (414) 461 1024 email rpcinfo@rotork.com Fluid Power Actuators and Control Systems Gearboxes and Gear Operators Projects, Services and Retrofit www.rotork.com As part of a process of on-going product development, Rotork reserves the right to amend and change specifications without prior notice. Published data may be subject to change. For the very latest version release, visit our website at www.rotork.com The name Rotork is a registered trademark. Rotork recognises all registered trademarks. Published and produced in the UK by Rotork Controls Limited. POWSH0809