Think & Do Profibus Network Setup with the H0 PSCM

Similar documents
OPERATOR INTERFACE PRODUCTS APPLICATION NOTE

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

FAQ Communication over PROFIBUS

How to configure a PROFIBUS network with NetTool for PROFIBUS

TECHNICAL NOTE TNOI30

Profibus DP Driver for JMobile

While every effort was made to verify the following information, no warranty of accuracy or usability is expressed or implied.

Korea PROFIBUS/PROFINET Association 각사회사이름 각사 LOGO

Upgrading from the 1785-PFB/B to the SST-PFB-PLC5

Danfoss FCD 300 AS-i and Siemens DP/AS-i Link 20E

Catalog 1 Product Overview General Important User Information About the Gateway Function Features Tec

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO

Training document for the company-wide automation solution Totally Integrated Automation (T I A) MODULE D3

AD4404 PROFIBUS Address Map 01/Aug./2005/ Section 11 K.Hobo/C.Seddon

User Manual. Profibus DP Master to Crowcon Vortex 12 Ch. Generic. Formac Electronics Ltd. T:+44 (0) Oxford House F:+44 (0)

Universal Serial/PROFIBUS DP Gateway GT200-DP-RS User Manual V6.1 SST Automation

Configuration and Parameter Assignment Frame for the CPU 31x-2

Technical Note. Programming the SST-PB3-VME-x for a Master or Slave in a VME Controller. Version: 1.1 Document #:

Profibus DP Expansion Board

SIMATIC. S7 and Profibus- DP Configuration Guide G1026

SST-PB3-SLC User Reference Guide

TS8000. Profibus DP Slave Configuration Application Note TS8922U001

Project Example Using LookoutDirect as an OPC Client

Modicon Quantum and Siemens S7-300 PLC as DP slave System User Guide [source code]

Connecting UniOP to Simatic S7 Profibus

GW-7553 PROFIBUS/Modbus TCP Gateway

Configuration and Parameter Assignment Frame for the DP/PA link and Y link

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

Training document for the company-wide automation solution Totally Integrated Automation (T I A) MODULE D5

*** If you have a Quick Designer project skip this section ***

LB/FB8X09* / LB/FB8X05*

AutomationDirect Application Note Connecting an EZ-Text panel to a Entivity (Think & Do) Live/Studio WinPLC

PROFIBUS Adapter. 20-COMM-P FRN 1.xxx. User Manual

i-7550 PRIFIBUS to RS232/RS485/RS422

DVPPF02-SL PROFIBUS DP Slave Communication Module

Profibus Getting Started User's Manual

Profibus PLC Setup Hardware setup, jumper settings and SYCON configuration. Design Studio driver configuration and I/O sheet setup.

Connecting UniOP to K-M Profibus DP

D0 DEVNETS and Allen Bradley Set up. RSNetworx

2005/2012 Series Profibus DP Technical Manual

HO PSCM Profibus Slave Communications Module User Manual

AutomationDirect Application Note Connecting an EZ-Touch panel to a Entivity (Think & Do) Studio/Live WinPLC

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

Product Description. Altus S. A. 1

Impressum. Internet:

Murdoch University Engineering Thesis. Appendix XII. Profibus PA System Configuration Instructions

PROFI-8455 PROFIBUS Remote I/O Unit

Cover. Configuration of an IM 308-C as DP Slave to a CP as DP Master PROFIBUS DP. FAQ July Service & Support. Answers for industry.

Technical Support Note No. 105 Date August 2002 Rev. 1

VitalSensors PROFIBUS PA Instruments with Rockwell PLC and SST card. Connecting a VitalSensors PROFIBUS PA Instrument to Rockwell PLC with SST card

RM30xx Profibus Brief instructions efector400

FD67 QUICK START GUIDE PROFIBUS-DP

User s Manual DX1000/DX1000N/DX2000 PROFIBUS-DP (/CP1) Communication Interface

FESTO Valve Terminals with EMERSON DeltaV Software

What s New in Release 2.0

FNL Modbus TCP Interface

Product Family: EZ Text Number: AN-EZ-006

Connecting UniOP to Profibus DP TI

Table of Contents. Initial Configuration of Runtime Workstation SMSI Server Development System OpenHMI P/N A 1-1

PowerFlexDC & 20-COMM-P Adapter with Siemens S7-315DP PLC

BB2 Profibus DP option

Table of contents chapter 1:

Modbus/ PROFIBUS DP Gateway PM-160

PROFI-5053 PROFIBUS Remote I/O Module Quick Start Guide

User Manual for the HE693PBS106 PROFIBUS SLAVE. Second Edition 05 June 2003 MAN

APPLICATION NOTE. Product Family: Hx-CTRIO Number: AN-MISC-022. Date Issued:

This Datasheet is for the IC693PBM200. Profibus DP Master Module.

Installation and Setup

SST-PB3-CLX-RLL User Reference Guide

ProfinetCommander User Manual 3.1 March 2010

IE/PB LINK PN IO. PROFINET applications

Integration of INTERBUS Into Profinet IO The Ideal Combination

TACC HART Over PROFIBUS User Manual

PAC BI-DP BIM and 8701-CA-BI Carrier

WinPLC and Serial I/O Module Installation and Operation. Manual Number: H2-WPLC-M

Scanners. status. Germany:

CAN 300 PRO, Communication Module

^2 Accessory 55E DeviceNet Option

Getting Started. Getting Started

HO PSCM Profibus Slave Communications Module User Manual

Product Description. Ordering Information. Nexto Series. Included Items. Product Code

Classic IO Modules (M12) for Profibus DP

Anybus CompactCom 40 Diagnostic Events for PROFIBUS APPLICATION NOTE

CDN Series Displays with Profibus-DP ELEN UNI-TXT (ND) protocol PARAMETRIZATION OF PROFIBUS-DP COMMUNICATION INTERFACE

Interfacing to J1939 with PROFIBUS DP

OPERATION MANUAL. DIGIFORCE 9311 PROFIBUS Integration into TIA Portal

RMx621. Appendix to the operating manual

MELSEC STlite Series

PS69-DPS. CompactLogix or MicroLogix Platform Profibus DP Slave Communication Module USER MANUAL

3G3FV SI-P Option Card for Profibus-DP Instructions 02/16/00

Emotron Fieldbus HMS Gateway Anybus Communicator

Max Felser. PROFIBUS Manual. mmww. swwmt. A collection of information explaining. PROFIBUS networks

BridgeWay. PROFIBUS to DeviceNet Gateway User Manual. Part No. AB7605. Publication PUB-AB

RMx621 /FML621. Appendix to the operating manual

Configure an X-Gateway EtherNet/IP Adapter with RSLogix 5000

User Manual. Interface for connecting max. 31 SIKO devices with RS485 interface to Profibus DP IF09P/1

OPERATING INSTRUCTIONS. Flexi Soft. Gateways

1788HP-EN2PA-R USER MANUAL

Installation Guide. Direct

PROFIBUS DP/CAN Gateway PCA-100. User Manual

Transcription:

Think & Do Profibus Network Setup with the H0 PSCM

E 2 Think & Do Profibus Network Setup Think & Do Profibus Network Setup with H0 PSCM For those who are using the H0 PSCM as a slave with Think & Do, the following steps will guide you through the setup for your Think & Do Profibus network. Getting the T & D Network Started The first thing that will be needed for the Think & Do Profibus network is a Profibus interface card for your PC. We use the SST Interface Card for Profibus, produced by Woodhead Industries, Inc.. More information about the purchase of this card can be obtained from their website, www.mysst.com. The PC used for the setup procedure explained here uses this interface card. Whenever this card has been installed, run the SST Profibus Configuration Tool to configure the Profibus card before beginning the Think & Do setup (refer to Appendix D). The following setup uses Think & Do Studio; however, if you have Think & Do LIVE installed on your PC, you will use I/O View instead of the Connectivity Center to setup the H0 PSCM DP Slave on the network. T & D Studio setup for PC control First, be sure that the Node Address has been set to a proper address (3 to 125 for the H0 PSCM). Next, open Think & Do Studio and select File > New in the Project Center window. Use the following procedure to setup the H0 PSCM with Think & Do Studio. The procedure assumes that the Profibus cable is connected from the SST card to your Communications Module. 1. Rename the project (the example name is PROFIBUS). 2. Click on the ConnectivityCenter button. Appendix E

Think & Do Profibus Network Setup E 3 This window will appear with a note to add the I/O driver. 3. Click on Drivers > Add in the drop down window which appears. Appendix C Error Codes Appendix E

E 4 Think & Do Profibus Network Setup The Add I/O Driver window will drop down. 4. Click on the down arrow and select the Profibus driver that is installed in your PC. 5. Click OK. This installs the SST driver to Think & Do configuration. Appendix E

Think & Do Profibus Network Setup E 5 The H0 PSCM Slave must be added to the configuration next. 6. Click on Devices or the Add Device button in this window. The following window will come into view. You will see a list of companies in the window on the left. Each of these have GSD files that are supported by Think & Do. If AutomationDirect is not in the list, you will need to install the GSD file from the diskette that was supplied with this manual. 7. Click the Add button. Appendix C Error Codes Appendix E

E 6 Think & Do Profibus Network Setup When this window comes into view, insert the diskette and select the A: drive in the Look in: window slot. 7. Click on Auto0779.gsd file to select the File name, then Add. The window appears like the one shown below. 8. Click on AutomationDirect.com, then IO. This puts the available GSD file names in the window on the right. 9. Select H0 PSCM and enter the PROFIBUS Address set on the rotary switches. 10. Click on Add Slave, then Done. Appendix E

Think & Do Profibus Network Setup E 7 Note: Once the GSD file has been added, simply click the Connect button after installing the Profibus I/O driver the next time that a slave is configured. Think & Do Studio will search the network for all connected slaves and the modules for each slave. You will need to select the name for each module found. The window now displays the H0 PSCM as a block with the name and address. Now that the H0 PSCM Slave has been added to the configuration, add the read and write information. 11. Either click on Devices or on the Add Device button. Add Device button Appendix C Error Codes Appendix E

E 8 Think & Do Profibus Network Setup The Add I/O Module to Modular Slave window will drop down. Select the module for Slot 1 by clicking on the down arrow next to the I/O Module. 12. Select 2 WORD READ FROM PLC. Click the OK button. Appendix E Repeat these steps for each slot with an input module installed.

Think & Do Profibus Network Setup E 9 The configuration window now shows the H0 PSCM Slave Communications Module with the added input module. The next step is to configure the module. 13. Click on Configure I/O Layout. The Configure I/O Layout window will appear. 14. Deselect Swap Bytes, then click on Apply and OK. Appendix C Error Codes Appendix E

E 10 Think & Do Profibus Network Setup Click on Parameterize in the Configuration window. The Parameterize window will appear with a default value of 1024. 15. Change 1024 to 16640 (40400 octal). Click on Apply then OK. Add the output module(s) in the Configuration window next. 16. Click on Devices > Add.

Think & Do Profibus Network Setup E 11 17. Select 1 WORD WRITE TO PLC in the window that appears, then click OK. 18. Now click on Configure I/O Layout and deselect Swap Bytes. Click Apply then OK.

E 12 Think & Do Profibus Network Setup 19. Click on Parameterize in the Configuration window. The Parameterize window will appear with a default value of 1024. 20. Change 1024 to 16704 (40500 octal). Click on Apply then OK. The H0 PSCM Slave Communications Module can now be put on line. 21. Either click on Configuration > Connect or on the Connect button. 22. After it is connected, either click on Configuration > Scan or on the Scan button. The system should now be running.