Quick Start Guide. ELPRO 105U-L Wireless I/O Receiver Unit. man_105u-l-r_quickstart_v1-8.doc

Similar documents
Quick Start Guide. ELPRO 905U-L Wireless I/O Receiver Unit. man_905u-l-r_quickstart_v1.9.doc

Installation Manual. 105U-L Wireless I/O. Version 1.9. man_105u-l_installation_v1.9.doc

Configuration Manual. 905U-L Wireless I/O. 905U-L Wireless I/O page 1 of 108. Version 1.3

115S Serial I/O Module User Manual

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

Grundfos MAGNA, GENI Module

AnalogBridge Analog transmission system

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

S82S (3/7.5-W Models)

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

What s in the Box? Weatherproof Camera transmitter with Antenna Power Cable 3m Sticker. 2 RVS SyStemS

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

Installation Instructions Model LFMWLT450, Class 1 Series AC-DC Power Supply

TLX-400 Wireless I/O Module. User Manual

PIM-Mini Pulsed Current Source Operation Manual

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

PCM-7140 Pulsed Current Source Operation Manual

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01

POWER SERIES Plus. 3 in 1 AC Voltage. Digital Switchboard Meter. User s Manual IM2493VVV-2

2-Way Wireless I/O Expander Installation Guide

Solid State Relays with Failure Detection Function

VIP-812A DUAL NETWORKED STATION PORT

3.5 inch Hard Drive Enclosure. Model #: HDE350U. User s Manual

3.5 inch Hard Drive Enclosure. User s Manual

MicroLink Installation Operation & Specifications Manual. General Description

11Mbps Wireless LAN Smart Access Point

Installation, Operation and Maintenance Manual

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE

Model 3526-B Digi-Probe Multimeter

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

WCC100 IN-VEHICLE CHARGING CRADLE OWNER S MANUAL

One Channel and Two Channel DALI Relay Device

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Ethernet/DALI Interface 2 DALI Lines

PWRguard PLUS Spring City Drive Waukesha, WI

Lotus DX. sit-stand workstation. assembly and operation instructions. MODEL # s: LOTUS-DX-BLK LOTUS-DX-WHT

PTT- Z or PTT-AZ or PTT-UX-AZ PUSH-TO-TALK USER GUIDE

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

OPERATION MANUAL. for the BO BLASTER S OHMMETER

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

CS1W-B7A. CS-series B7A Interface Unit. It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort,

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

USER S MANUAL ENTITY. Energy Meter TRINITY. Entity Operational Manual

Page/Talk Industrial Desk Sets

Models VSP12824V & VSP12860V

SK-1011-SQ Digital Access Keypad with 5A Relay Output

PSA200 User s Manual

Features various encoder interfaces and controls multiple analog servo drives at high speeds

ENFORCER SK-1131-SQ. Digital Access Keypad with 5A Relay Output MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

OPERATION MANUAL BO BLASTER S OHMMETER

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

POWER SERIES Plus Watt / VAR / Power Factor Digital Switchboard Meter User s Manual IM2493WVP-3

EverPump Wireless Pump control system

MTP INSTRUCTION MANUAL

Model Number Structure

NJ-Series Power Supply Unit NJ-PA/PD

SOLVES-IT! 4 CHANNEL TIMER APPLICATION MODULE

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Innovative Circuit Technology Ltd.

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

RLD-7.2 Two Channel Light Dimmer. (P/N: P-RLD-72 Digital) User & Installation Manual

LCI User Manual mantracourt.com

MAXIMA+ Series Rotary Level Indicator

S66 Series Electronic Fan Speed Control

CO2 Controller Operating Instructions Models: RAD-0501, RAD-0501A, RAD-0501E 1. Product Description

PRODUCT CONTENTS... 3 II. REQUIRED MATERIALS... 3 III. OVERVIEW... 3 IV. BENCH LAYOUT...

CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL Stancliff Road Phone: (281)

550 Watt Power Supply

NX8 Pocket Toner Users Guide

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

FNet Repeater Installation & Operator s Instruction Manual

V-9908 MESSAGE/PAGE PANEL

ATX 450 and ATX 550 Watt Power Supplies

Digital Lighting Systems, Inc.

LEDsmart+ Slave Relay Device

Telephone Line Monitor USER GUIDE

RTD SAMPLER OPERATOR S MANUAL

MYRIAD RTU REMOTE TELEMETRY UNITS INSTRUCTION MANUAL

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

American Power Design, Inc.

Transcription:

Quick Start Guide ELPRO 105UL Wireless I/O Receiver Unit man_105ulr_quickstart_v18.doc

ELPRO 105UL Wireless I/O Receiver Unit Quick Start Guide About this document This document is the ELPRO 105UL Wireless I/O Receiver Unit Quick Start Guide and contains the following sections: Section Basic steps for using your unit Factory default configuration Unit components Antenna installation Resetting factory defaults Linking transmitter and receiver units Safety information Read this section if you want to Learn the basic steps for installing and using your unit. Understand how the transmitter sends information to the receiver. Understand the different parts of your unit. Learn how to install an antenna with your unit. Reset your unit to the original factory default settings. Link your units to work as a dedicated pair. Understand important safety information related to your unit. NOTE: You must read this information before installing your unit. Specifications Know technical information about your unit. For more information, see the next sections. Basic steps for using your unit This document describes how to configure your unit using the default factory configuration that lets you easily setup your network as a simple send/receive network using a dedicated pair of transmitter and receiver units. The basic steps for using your unit are: 1. Connect the antenna power supply and transducer signals using the instructions in this document. Power supply and transducer connection is described in the section Unit components and connections. Antenna connection is described in the section Antenna installation. For more information, see the 105UL Installation Manual. 2. Reset the transmitter and receiver units to the factory default configurations. 3. Link the transmitter and receiver units to work as a dedicated pair. 4. Bench test your configuration before deploying. NOTE: You can also configure your network using a userdefined customised configuration that lets you set specific information about your network. For more information on setting a userdefined customised configuration, see the 105UL User Manual on the enclosed CD. Factory default configuration When you configure the units using the configuration in this document, the inputs from the transmitter are sent to the outputs at the receiver as follows: 105ULT(Transmitter) Sends 105ULR (Receiver) Digital Input 1 Digital Output 1 Digital Input 2 Digital Output 2 Analogue Setpoint Digital Output 3 Analogue input (420 ma) Analog output (420 ma) Thermocouple Input (Not used) Setpoint Output (Local indication) System OK (On if system OK) Communication Failure (Comes on if no messages from 105ULT) System OK (On if system OK) ELPRO 105UL Wireless I/O Receiver Unit Version 1.8 page 2 of 8

ELPRO 105UL Wireless I/O Receiver Unit Quick Start Guide Unit components and connections Your 105UL receiver unit has the following components and terminal connections: Earth Wire Lug underneath Unit 24V SYSTEM OK COMMS FAIL COMMON AO POWER SUPPLY NOT USED NOT USED DO 3 DO 2 DO 1 Max. 30VDC 500mA For inductive load, use surge diodes LOAD LOAD DO 2 DO 1 DC LOAD DO 3 ANALOG OUTPUT Max. analog load 900 ohm AC LOAD POWER SUPPLY 9 30 VDC 250mA @ 12V 125mA @ 24V DO contacts are rated at 1A, 250VAC For good engineering practice, use a surge diode for DC loads and a surge capacitor (10nF 250V) for AC loads **IMPORTANT ELECTRICAL SAFETY INFORMATION** In order to comply with Electrical Safety Regulations, this module must be installed in an Electrical AND Fire enclosure. This enclosure may be a single or multiple enclosures. Access to the module is to be made by a Service Person only. In order to comply with Electrical Safety Standards, when connecting SELV AND voltages which are greater than SELV (30VAC or 60VDC) together, then Relay Output 2 must NOT be used in order to provide sufficient isolation between the outputs ELPRO 105UL Wireless I/O Receiver Unit Version 1.8 page 3 of 8

ELPRO 105UL Wireless I/O Receiver Unit Quick Start Guide front panel contains the following components: The LEDs on the front panel indicate the unit status: LED Status None OK LED Green OK LED Red RX Led Flashes CF Led ON PG LED on Output LED ON LEDs with RSSI Push Button Pressed Output LED flashing quickly Indicates No power supply. Current status of the unit OK. Fault condition detected in unit. Receiving Message. Module Communication Failure Output is active. Configuration Cable Connected. The Output LEDS (i.e. D1, D2, D3) light when the corresponding output is active. D1 D2 D3 Relay output D1 is ON (Contact Closed). Relay Output D2 is ON. Relay Output D3 is ON. When you press the RSSI push button, the unit shows the signal strength by lighting the LEDs from the bottom to the top. Signal strength is the strength of the last message received that was addressed to this station. LED Signal Strength LED Signal Strength D1 More than 85 dbm RX More than 100 dbm D2 More than 90 dbm CF More than 105 dbm D3 More than 95 dbm PG Always on during RSSI test If an output is in communication failure, the corresponding LED flashes at 5 Hz. D1 D2 D3 PG Relay Output D1 is in communication failure. Relay Output D2 is in communication failure. Relay Output D3 is in communication failure. Analog output is in communications failure. ELPRO 105UL Wireless I/O Receiver Unit Version 1.8 page 4 of 8

ELPRO 105UL Wireless I/O Receiver Unit Quick Start Guide Antenna installation ELPRO 105UL Wireless I/O Receiver Unit Version 1.8 page 5 of 8

ELPRO 105UL Wireless I/O Receiver Unit Quick Start Guide Resetting your unit to factory defaults You must reset the receiver unit to factory defaults before linking the transmitter and receiver units. To reset the default factory configuration: 1. Press and hold the RSSI push button. 2. Power on the 105UL receiver. 3. The 105UL receiver flashes all LEDs at medium flash (i.e. 1.6 Hz). NOTE: If the LEDs do not flash, you must repeat steps 1 and 2 until the LEDs flash before continuing. 4. Release the RSSI push button within 5 seconds. 5. Within a further 60 seconds, press and hold the RSSI push button for 5 seconds (until the LEDs stop flashing) and then release. 6. The 105UL receiver lights all LEDs for 2 seconds before returning to normal operation. NOTE: If the LEDs do not light, you must repeat the process from step 1 until the LEDs light before continuing. 7. You can now link the transmitter and receiver units. Linking your transmitter and receiver units You must reset the transmitter unit to factory defaults (to disable encryption) before linking the transmitter and receiver units. For more information, see the 105ULT Transmitter Quick Start Guide. NOTE: You must complete the linking process in 60 seconds. To link the transmitter and receiver units: 1. Press and hold down the RSSI Pushbutton on the receiver. 2. Power on the receiver while holding down the RSSI Pushbutton 3. Release the RSSI Pushbutton as soon as the Receiver LEDS flash (within 5 seconds of powering the receiver). 4. The receiver will flash all LEDs for a maximum 60 seconds while it tries to link to the transmitter. 5. Power on the transmitter. The transmitter sends a special Link message to allow the receiver to recognise the transmitter. 6. When the units link, the receiver lights all LEDs for 2 seconds before returning to normal operation. NOTE: If the receiver LEDs continue flashing within the 60 seconds, the units are not linked and you should retry the linking process by powering the transmitter off and on again. If you exceed the 60 seconds, you must restart the linking process from step 1. 7. You can now bench test your configuration before deploying. ELPRO 105UL Wireless I/O Receiver Unit Version 1.8 page 6 of 8

ELPRO 105UL Wireless I/O Receiver Unit Quick Start Guide Safety information Thank you for selecting the 105UL receiver for your telemetry needs. We trust it will give you many years of valuable service. To ensure your 105UL receiver enjoys a long life, doublecheck ALL your connections with the user s manual before powering on the unit. WARNING: Incorrect termination of supply wires may cause internal damage and will void warranty. Unit specifications Input/output Number Additional information Digital outputs 3 Voltagefree contacts rated at 250 VAC 1A, 30VDC 1A. 2 for digital inputs and 1 for setpoint. Status outputs 2 Separate System OK and communication failure output. Analog output 1 16bit resolution, 0.1% accuracy, singleended source output. Power supply 1 930 VDC 0.25 Amp CSA certified Class 2 power supply. For use in Class I Div 2 explosive areas, the power supply must be approved for Class I Div 2 use. WARNING: Explosion hazard do not disconnect while circuit is live unless area is known to be nonhazardous. Radio receiver 1 High sensitivity DFSK Fixed Frequency receiver. Frequency 868.525 MHz 869.875MHz Sensitivity 111 dbm At PER 8%. Actual frequency range depends on Paired Transmitter. ELPRO 105UL Wireless I/O Receiver Unit Version 1.8 page 7 of 8

ELPRO 105UL Wireless I/O Receiver Unit Quick Start Guide Document information Quick Start Guide ELPRO 105UL Wireless I/O Receiver Unit Version 1.8 ELPRO contact details Address > 9 /12 Billabong Street Stafford, QLD 4053 Telephone > 61 (0)7 3352 4533 Fax > 61 (0)7 3352 4577 Email > Website > sales@elprotech.com www.elprotech.com Copyright Copyright 2006 ELPRO Technologies Pty Ltd. All rights reserved. Limited lifetime warranty, disclaimer and limitation of remedies ELPRO products are warranted to be free from manufacturing defects for the serviceable lifetime of the product. The serviceable lifetime is limited to the availability of electronic components. If the serviceable life is reached in less than three years following the original purchase from ELPRO, ELPRO will replace the product with an equivalent product if an equivalent product is available. This warranty does not extend to: Failures caused by the operation of the equipment outside the particular product's specification, or Use of the module not in accordance with this User Manual, or Abuse, misuse, neglect or damage by external causes, or Repairs, alterations, or modifications undertaken other than by an authorized Service Agent. ELPRO s liability under this warranty is limited to the replacement or repair of the product. This warranty is in lieu of and exclusive of all other warranties. This warranty does not indemnify the purchaser of products for any consequential claim for damages or loss of operations or profits and ELPRO is not liable for any consequential damages or loss of operations or profits resulting from the use of these products. ELPRO is not liable for damages, losses, costs, injury or harm incurred as a consequence of any representations, warranties or conditions made by ELPRO or its representatives or by any other party, except as expressed solely in this document. ELPRO 105UL Wireless I/O Receiver Unit Version 1.8 page 8 of 8