Industrial SBU Product User s Manual

Similar documents
3600B Series Bench Scale

QC-3265 Checkweigher User s Manual

WI-130 WDAC User s Manual

Model Bulk Sampling Scale. User s Manual

Model 7620U. Bench Scale. User s Manual

Model 815 User s Manual

WI-125 (QTLTSC) Indicator User's Manual

Digital Bench Scale. Revision 1.2 September 14, 2000 Contents subject to change without notice.

Model 7821 Bench Scale. User s Manual

Installation / Operator / Service Manual. Bench Scales Revision 6 07/ by Fairbanks Scales Inc. All rights reserved

Installation Job Aid for Ethernet Routing Switch 3600 Series

North American Service Manual

Copyright Western Scale Co. Limited. All rights reserved.

Model 7600 Family Postal Weight Classifiers. Model Model User s Manual

Digital Bench Scale. Revision 1.2 August 24, Contents subject to change without notice.

Digital Bench Scale. Revision 8.93 August 12, 1993

Ultegra Baggage Scale. SCB-R9000-B Series 31 x 31 Baggage Scale. Operator Manual

QuickSilver Series Bench Scale

Series Amp Pad Mount Quick Connect Input and Output Power Panels

PC 150. Digital Bench Scale. Operation Manual

Piece Weight Look-Up (PWLU) Software Program for the PC-820

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

Installation Job Aid for VSP 4850GTS

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

Mounting Dimensions / Viewing 2 Mounting Options 3. Wiring Configuration 4. Quick Set up Procedure 5. Changing Intensity 6.

Weigh Legs (Static and In-Motion Scales) Installation Manual

4170 POS System Installation Guide

S7999D SOLA Operator Interface Display

E-Series Site Preparation Guide

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

PS-IN202 Weighing Indicator User Manual

Installation Job Aid for VSP 4450GTX-HT- PWR+

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Perle MCR200 Installation Guide

Installation Instructions

SERIES 208 INSTALLATION & OPERATING MANUAL

Specifications, Installation, and Operating Instructions

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Transportation Management Console

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

AUD-340 Installation Guide

MODEL: R2K-1 SEN TRONIC AG. R2K Series

Hardened Ethernet to VDSL2 Extender. User Guide. Revision History. Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Rev.1.

Digital Weight Indicator Setup / Operation Manual

Level-Lance Model 5400A

H704-42(H)(E), H704-42/1(H)(E)

ESA SERIES ELECTRONIC BALANCE

Installation Manual. Alpha 4000 RGB Signs. Before you begin

Model PC-400 Portion Control Scale

CONTROL MICROSYSTEMS Differential Analog Input Module. Hardware Manual

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

TRC-190 User s Manual

Operator Manual. Ultegra MAX. SCB-R9050 Series 21 x 21 Bench Scale by Fairbanks Scales, Inc All rights reserved Revision /15

Service Manual. Operators Manual. Ultegra Health Scale by Fairbanks Scales, Inc All rights reserved Revision 7 04/17

Calibration & Connectivity

Basketball Shot Clock Set LX2180 Manual

Models: TD3000 Series. Table Displays. 2 by 20 character display USER MANUAL

TMP1700E/420 DATASHEET

Userʼs Guide. 1200g High Precision Scale. 1200g High Precision Scale. Legal for Trade. Includes RS-232 interface port. UG Version 1.

Junos WebApp Secure 5.0 Hardware Guide

PC-150. DIGITAL BENCH SCALE Setup / Operation Manual

Installation Instructions Model LFMWLT450, Class 1 Series AC-DC Power Supply

ASTAT XB/XBm Remote Operator

AUD-220 Installation Guide

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

CONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual

FB1100 Series. Digital Instrument Products: Owner s Manual

High Power over Ethernet Midspans PD Port Model PD Port Model

BCM2 Series Branch Circuit Monitors Quick Setup Guide

1.0 Description. 2.0 Unpacking. 3.0 Installation

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

The information in this chapter will enable you to: Understand the product's basic functions & features

Installing the Cisco AS5400XM Universal Gateway

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VM-24H 2 Input 1:4 HDMI Distributor. P/N: Rev 4

Enhanced Mini-Chansim Model VCS-232

TMP3200E/420 DATASHEET

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

TI-500 Plus DIGITAL WEIGHT INDICATOR Setup / Operation Manual

DANTE BRIDGE. Operation Manual

RS-422 Code-Operated Switches

XBR V4 INSTALLATION AND USER GUIDE

Series Amp Quick Connect Input and Output Power Panels

CONTENTS. PRECAUTIONS Introduction Installation... 7

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001

Vorne Industries. 87/708 Master Clock Display User's Manual

P3-RS Remote Slave Module

Model DS100 Scale Indicator

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Model PC-400 Portion Control Scale

EPS Power Supply

solartron digital readout model no. DR600 DR700 installation manual

Optima OP-902 User Manual

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

D840/D820. Remote Display Installation Manual

iconverter 2-Module Power Chassis

MWP SERIES. High Precision

SIMATIC VPU Hardware Manual. Order Number: PPX:560/ Manual Assembly Number: Second Edition

BenchMark 320 Datasheet

Transcription:

Industrial SBU Product User s Manual

EUROPEAN COUNTRIES WARNING This is a Class A product. In a domestic environment this product may cause radio interference in which the user may be required to take adequate measures. CAUTION Risk of electrical shock. Do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel. Weigh-Tronix reserves the right to change specifications at any time. 01/29/01 BAG_U.P65 PN 7424-09051F e1 Printed in USA 2

Table Of Contents Section 1 - General Information Introduction... 1 Specifications... 1 Options... 1 Section 2 - Installation Initial Inspection... 2 Leveling the Scale... 2 Mounting Displays... 2 Electrical Requirements... 2 Display Mounting Diagram... 3 Platform Mounting Diagram... 4 Communications Protocol... 5 Section 3 - Operation Keys... 6 Indicators... 6 Normal Weighing Operations... 6 Troubleshooting... 6 3

Specifications Model* Dimensions Capacity SC-1824 18" x 24" SC-2226 22" x 26" SC-2227 22" x 27" SC-2229 22" x 29" 300 x.1 lb / 150 x 0.05 kg. SC-2424 24" x 24" or SC-2730 27" x 30" 500 x.2 lb / 250 x.1 kg. *Custom sizes available upon request. Construction: Power Requirements: Display and Indicators: Control keys: Environmental Limits: Temperature Humidity Accuracy: Options: Base: Stainless steel shroud with painted mild steel frame and molded Lexan electronics enclosure. Display: Enclosure of aluminum and a front panel of stainless steel. 117 VAC (+10%, -15%), 50/60 Hz (±3 Hz),.25 Amp. Max. Master display consists of an LCD display, a ZERO annunciator, and a lb/kg annunciator. Slave displays have an LCD display. Three membrane keys: ZERO, LB/KG, and DSPLY ON. (Slave display has no control keys.) -10 C to +40 C (14 F to 104 F) 10% to 95% relative, non-condensing Meets NTEP Class III 3000 division weighing accuracy. Consult the factory for devices which have Canadian Weights and Measures approval. Side guides for shroud RD-190 Remote Display (up to three can be used) RS-232 Output Accumulator Safety: UL 114 Section 2 - Installation 4

Section 1 - General Information Introduction The Model SC Baggage Scale is a reliable, easy to install and easy to operate weighing system designed for use in a rugged baggage check environment. The scale consists of a weighing platform and a Model WI-190 Remote Master Display. The system can also accommodate up to three additional Model RD-190 Remote Slave displays as an option. The Master Display has three control switches to allow the operator to zero the scale, select units of measure (lb. or kg.) and turn the display on and off. Section 2 - Installation Initial Inspection This scale has been calibrated and inspected for mechanical and electronic integrity prior to shipment. It should be free of defects and in perfect operating condition upon receipt. To confirm this, the scale should be inspected immediately for any physical damage incurred in transit. If the scale is damaged, contact the Weigh-Tronix Service Department at once. Installing and Leveling the Scale Place the platform on a stable, non-vibrating, level surface. Adjust the feet so that the platform is level and all four feet are in equal contact with the surface. Use the leveling bubble located on the top of the load cell to level the platform by adjusting the feet, then tighten the lock nut on each of the feet to 35-40 inch-pounds. If required, the platform can be secured using appropriate bolts (not supplied) through the hole in the middle of each base rail. Refer to figure 2. Platform mounting bolts should be installed snugly but not tight enough to deform base rails. Mounting Display Select the location for the master and slave displays keeping in mind that each display mounting surface must be accessible from the rear (for recessed mounting) and within 14 feet maximum of cable routing distance of the base. See Figure 1 for mounting instructions and dimensions. 5

Connecting Display to Base Remove shroud from scale base and route display cable under base and beneath electronics housing. Connect 8 pin phone jack to the receptacle next to the load cell connector. Failure to properly route display cable underneath the electronics housing could allow the cable to contact the shroud or load bridge causing weighment errors. Electrical Requirements The scale requires a 117 VAC, 50/60 Hz power source, isolated from electrical noise inducing equipment such as motor starters, fluorescent lighting, etc. The scale is supplied with a UL standard 3-prong plug for AC operation and must be connected to an outlet which provides a third wire earth ground to insure proper operation and safety. The ground wire must be connected to the building safety (earth) ground and neutral bus at the main fuse box. Connecting the scale to an outlet without a safety ground, by-passing the safety ground, or in any other way disrupting the safety earth ground, could make the scale an electrical shock hazard, or could affect its operation. 6

Figure 1 Mounting the Display NOTES: For recessed surface mounting follow the instructions below: 1. Determine mounting location and method. 2. Cut hole in mounting surface to dimensions shown. 3. Insert cable and display into cutout. 4. Install T-nuts into mounting holes from rear of counter. 5. Install and tighten the two hood down screws through front panel against mounting surface to secure display assembly firmly. Recessed surface mounting (Recommended for both models WI-190 and RD-190) 7

Figure 2 Scale Dimensions DIMENSION TABULATION MODEL NUMBER DIM A DIM B DIM C DIM D DIM E* DIM F DIM G SC-1824 18.00 24.00 15.50 22.00 5.38 11.00 3.00 SC-2226 22.00 25.00 19.00 23.54 5.38 11.75 3.00 SC-2227 22.00 27.00 19.00 20.00 5.38 10.00 3.00 SC-2229 22.00 29.00 19.00 25.00 5.38 12.50 3.00 SC-2424 24.00 24.00 19.00 22.00 5.38 11.00 3.00 SC-2730 27.00 30.00 24.00 25.00 5.38 12.50 3.00 * ±3/8" FOOT ADJUSTMENT 8

RS-232 Communications Communications Protocol Baud Rate Parity Data Bits Stop Bits 1200* even* Seven* 1* 2400 odd Eight 4800 9600 * Default Setting Computer commands and scale responses are ASCII character strings. (CR) is an ASCII carriage return. (LF) is an ASCII line feed. (ETX) is an ASCII end of text COMPUTER COMMAND SCALE REPONSE RESULTS W (CR) (LF)xxxxx.xlb (CR) Returns weight, and (LF)hh(CR) (ETX) returns scale status. S(CR) (LF)Shh(CR) (ETX) Returns scale status in two ASCII bytes. Z(CR) no response Zeros scale. All else (LF)?(CR) Unrecognizable command. Interpretations of Scale Status Hex Digits - High Order Byte: Bit 0: High = scale in motion Low = scale stable Bit 1: High = scale at zero Low = scale not at zero Bit 2: Not used Bit 3: Not used Low Order Byte: Bit 0: High = scale is under capacity Low = scale is not under capacity Bit 1: High = scale is over capacity Low = scale is not over capacity Bit 2: High = scale ROM program failure Low = scale ROM is OK Bit 3: Not used PIN SIGNAL DESCRIPTION DIRECTION 2 TXD Transmit Data from scale to peripheral 3 RXD Receive Data from peripheral to scale 1 SG Signal Ground 6 Chassis Ground 4 DSR Data Set Ready from peripheral to scale 5 DTR Data Terminal Ready from scale to peripheral 9

Section 3 - Operations Keys There are three keys or buttons on the baggage scale master display: ZERO - LB/KG - DSPLY ON - Press this key to zero the display and start Auto Zero Tracking. Press this key to toggle between pound and kilogram units of measure. Press this key to turn the display on or off. Indicators The display has several indicators to tell you the operating condition of the scale. ZERO - LB - -------- KG - -------- This indicator illuminates whenever the scale is within ±1/4 digit of scale zero. This indicator is illuminated when displaying weight in Avoirdupois pounds. This indicator is illuminated when displaying weight in kilograms. Upper Dashes indicate a weight exceeding the stated capacity is on the scale. Lower Dashes indicate a weight less than zero is on the scale. Normal Weighing Operation When the scale is first powered up the display will show rotest, then the model number, the software revision level, and then perform a display test. It then enters normal weighing mode. To perform a normal weighment follow these instructions: 1) Zero the scale by pressing the ZERO key. Display should read 0. 2) Place baggage to be weighed on the scale platform. The gross weight will be displayed. 3) Remove the baggage from the scale platform. Troubleshooting If you have any problems, check the items listed below before calling an authorized service representative: 1) Make sure the scale is plugged into a live power outlet. 2) Be sure the scale is stable. It should not be subject to air currents, vibration from nearby motors, or contact with nearby objects. 3) Be sure all connecting cables are firmly seating in mating connectors. 4) Make sure the scale is level and all four feet are evenly supporting the weight of the scale. 10

11

Weigh-Tronix 1000 Armstrong Dr. Fairmont, MN 56031 USA Telephone: 507-238-4461 Facsimile: 507-238-4195 e-mail: industrial@weigh-tronix.com www.wtxweb.com Weigh-Tronix Canada, ULC 217 Brunswick Blvd. Pointe Claire, QC H9R 4R7 Canada Telephone: 514-695-0380 Facsimile: 514-695-6820 Weigh Bar is a registered trademark of Weigh-Tronix Inc. Weighing Products & Systems