USB DIO High Voltage and Relay

Similar documents
USB-PDISO8 Specifications

USB-ERB24. USB-based 24-Channel Electromechanical Relay Interface Device. User's Guide. May Rev 8A Measurement Computing Corporation.

USB-PDISO8/40. USB-based Isolated Input and Relay Output. User's Guide. September Rev 6 Measurement Computing Corporation

USB-SSR08. USB-based Solid-State 8 I/O Module Interface Device. User's Guide. January Rev 6A Measurement Computing Corporation

Preface About this User's Guide... iv What you will learn from this user's guide... iv Conventions in this user's guide... iv

USB-1616FS. Analog Input and Digital I/O. Specifications

BTH-1208LS Wireless Multifunction DAQ Device

Specifications USB-1616FS

A 40-pin connector provides access to 24 DIO connections.

USB-DIO96H/50 Specifications

PCI-PDISO8. Isolated Input and Relay Output. User's Guide

USB 1608G Series USB Multifunction Devices

USB-ERB24 USB-based 24-Relay Module User's Guide

DIO-0808RN-USB. N Series for USB Isolated Digital I/O Unit(8ch Relay Output, 8ch DI) DIO-0808RN-USB 1. Ver.1.02

USB 1608G Series USB Multifunction Devices

Specifications

USB-DIO24H/37 Specifications

WLS-TC Specifications

USB-PDISO8. USB-based Isolated Input and Relay Output. User's Guide

USB-4303 Specifications

USB-DIO96H/50. High-drive Digital I/O. User's Guide. Hardware Revision 2

Specifications minilab 1008

PCIe-DIO24. Digital Input/Output. User's Guide. September Rev 3 Measurement Computing Corporation

Signal Conditioning Modules and Terminal Boards

6220 Ethernet-Based Voltage Measurement Module

PCI-DIO24H Digital I/O User's Guide

LGR-5325 Specifications

USB-201-OEM. Analog and Digital I/O. User's Guide

Features. High-precision Analog input board (Low Profile size) for PCI Express AI-1616L-LPE AI-1616L-LPE 1. Ver.1.01

USB-2527 Specifications

Chapter 1 Introducing the OM-USB Functional block diagram... 5

USB-201. Analog and Digital I/O. User's Guide. January Rev 7 Measurement Computing Corporation

USB-TC. Thermocouple Measurement. User's Guide. October Rev 10A Measurement Computing Corporation

User's Guide. CIO-PDISO8

USB-1602HS-2AO Specifications

AIO LN-USB. Features. N Series for USB Multifunction DAQ Unit (8ch AI, 2ch AO, 16ch DIO) AIO LN-USB 1. Ver.1.01

Analog Input Sample Rate

A variety of ECONseries modules provide economical yet flexible solutions. Waveform Generation

LGR-5327 Specifications

WebDAQ 316. Internet Enabled Thermocouple Logger. Remote Configuration and Monitoring. Virtually Unlimited Storage. Integrated HW and SW

Chapter 1 Introducing the OM-USB-1608FS-Plus... 6 Functional block diagram... 6

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Specifications USB-1616HS

Specifications PMD-1208FS

Specifications USB-1408FS

DT3016. High-Speed, Multifunction PCI Data Acquisition Board. Overview. Key Features. Supported Operating Systems

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

AIO UE3-PE. Features. 1MSPS 12-bit Analog I/O Board for PCI Express AIO UE3-PE 1. Ver.1.01

USB-1208LS Specifications

AD16-16(PCI)EV. Features. High-Resolution Analog Input Board for PCI AD16-16(PCI)EV 1. Ver.1.01

±500 V Isolation Protects Your Data. Sample Rate. 16 bits ±1.25 V, ±2.5 V, ±5 V, ±10 V 100 ks/s 16 2

AD12-16(PCI)EV. Features. Analog Input Board for PCI AD12-16(PCI)EV 1. Ver.1.01

Personal Daqs USB Data Acquisition Modules Models /55 & /56

Industrial USB I/O Modules

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

ADI12-16(PCI) Isolated Multi-Function Analog Input Board for PCI ADI12-16(PCI) 1. Ver.1.01

AO-1604LX-USB. Features. High-Resolution Analog Output Unit for USB AO-1604LX-USB 1. Ver.1.01

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

48-Bit Isolated Digital I/O

SPST-NO SPDT DPST-NO DPDT

Features. Specifications. Digital Output Board with independently common Relay-Isolation for PCI RRY-16C(PCI)H

Specifications

6220 Ethernet-Based Voltage Measurement Module

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

DIO-1616TB-PE. Features. Packing List. PCI Express-compliant High-Speed TTL level Opto-isolated Digital I/O DIO-1616TB-PE 1. Ver.1.

78 Series Electromechanical Relay Selection Guide

Product Manual Amp Current Sensor AC/DC

Time Counters mini "h", DC Version

Multifunction Transducer MT440

PC-CARD-DAS16/12 Specifications

USB Analog Input and Digital I/O Measurement and Control. User's Guide

ADI12-8(USB)GY. Features. Packing List. F&eIt Series Isolated Analog Input Module for USB ADI12-8(USB)GY 1. Ver.1.02

PC-CARD-DAS16/16 Specifications

Chapter 1 Introducing the OM-USB-1608G Series...6 Functional block diagram...7

NI 6521 Specifications

USB-3110 USB-based Analog Output User Guide

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

H3CR-F H3CR-F8 H3CR-F-300 H3CR-F8-300

DaqBoard/3000USB Series USB 1-MHz, 16-Bit Data Acquisition Boards

AD16-16(PCI)EV. Features. High-Resolution Analog Input Board for PCI AD16-16(PCI)EV 1. Ver.1.02

IST ULTRASTAB Power Supply for high precision transducers

A variety of ECONseries modules provide economical yet flexible solutions

USB Multifunction Measurement and Control. User's Guide

AC-DC POWER SUPPLY UNIVERSAL INPUT, DESK TOP, WATTS MEDICAL APPLICATIONS MUI310-A Series

AD12-16(PCI)EV. Features. Analog Input Board for PCI AD12-16(PCI)EV 1. Ver.1.02

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

Ultra-Accurate Measurement for Temperature and Voltage

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

DIO-1616B-PE. Features. Packing List. PCI Express-compliant Opto-isolated Digital I/O Board with On-board power supply DIO-1616B-PE 1. Ver.1.

CNT24-2(USB)GY. Features. Isolated Counter Input Module for USB 2.0 CNT24-2(USB)GY 1. Ver.1.03

User's Guide. CIO-RELAY08 CIO-RELAY16 CIO-RELAY24 CIO-RELAY32

USB1. Encoder Data Acquisition USB Device Page 1 of 6. Description. Features

SmartFan Fusion-4. Speed Control and Alarm for DC Fans CONTROL RESOURCES INCORPORATED. The driving force of motor control & electronics cooling.

PCI-DAS1602/12 Specifications

TIME DELAY RELAYS Product Summary

7511 / / / 711 / / 731 / Preset 27

Operating Manual. USB-based High-Precision 8-channel Temperature Measurement device and Data Logger MODEL NO

Classification Enclosure rating Input voltage Type of

Transcription:

DIO High Voltage and -PDISO, -ERB, and - Series -PDISO Series -ERB Series - Series Overview Measurement Computing DIO high voltage and relay product offerings include the -PDISO Series, -ERB Series, and - Series. The -PDISO Series offers eight isolated AC or DC inputs and eight electromechanical relays in a single digital I/O system. The -ERB Series enables a PC or laptop to control eight to 2 electromechanical relays. The - Series can monitor and control eight to 2 standard size solid state relay () I/O s (relays sold separately). All devices in these series come in a heavy-duty metal enclosure with integrated mounting slots, which ensures that the devices are rugged enough for any DAQ application. Contacts and Connectors -PDISO/-ERB Series Only The -PDISO and -ERB Series devices provide screw terminal connections to the relay contacts. The -PDISO/0 provides relay connections through a 0 pin connector. Each relay has a normally closed (NC), common (C), and normally open (NO) contact. s on all devices are controlled by digital I/O lines. Digital I/O Control Modules - Series Only The -0 provides mounting locations for eight digital I/O s, and the -2 provides mounting locations for 2 s. digital I/O s are relay control s that provide 000 Vrms of optical isolation. Digital input s sense AC/DC voltages from field devices and convert them to digital TTL signals. Digital output s use TTL signals to switch and control AC/DC loads. A wide selection of digital I/O s are available to switch or sense a large range of AC or DC voltages. Features -PDISO Series Form C relays isolated AC or DC inputs -ERB Series or 2 Form C singlepole double-throw (SPDT) electromechanical relays. - Series or 2 input or output channels to control and monitor solid state relays. Screw terminal or header connectors Heavy-duty chassis with integrated mounting slots Includes external power supply (required for all devices) Supported Operating Systems Windows 10//7/Vista /XP 32/6 bit The s use a standard color scheme to help quickly identify the type installed. Compatible s are available separately (refer to Digital I/O Modules on page 10). -PDISO Series, -ERB Series, and - Series Selection Chart Model Channels Contact Rating Daisy Chain Support Signal I/O Connector -PDISO Form C (SPDT) 6 amps at 20 VAC/2 VDC 0-pin screw terminal -PDISO/0 Form C (SPDT) 6 amps at 20 VAC/2 VDC 0-pin header connector -ERB0 Form C (SPDT) 6 amps at 20 VAC/2 VDC 2-pin screw terminal -ERB2 2 Form C (SPDT) 6 amps at 20 VAC/2 VDC 72-pin screw terminal -0 Solid State Modules 16-pin screw terminal -2 2 Solid State Modules -pin screw terminal Measurement Computing (50) 96-5100 1 info@mccdaq.com mccdaq.com

DIO High Voltage and Overview I/O Module Type Switch - Series devices have an onboard switch to configure each group for either input or output. Devices are shipped with all s configured for output. Input and output s cannot be mixed within a group. Positive and negative relay contacts are brought out to screw terminals for field wiring connections. Configuration Switches ERB/- Series Only - Series and -ERB Series devices have two onboard switches for configuring the relay logic polarity and output relay power-up state for each relay bank/ group. The current configuration of each switch can be read back with software. Devices are shipped with all relay banks/ groups configured for non-inverted logic and pull-up (relays/s inactive on power-up). Differential Isolated Digital Inputs -PDISO Series Only All eight inputs on -PDISO Series devices can be driven by either AC (50 Hz to 1000 Hz) or DC voltage, and can be read back as a single byte. Each input has a software-selectable filter with a time constant of 5 ms (200 Hz). The filter is required for AC inputs, and recommended for most DC inputs. Each group can be set to either input or output (default). Input and output s cannot be mixed within a group. Up to eight optically isolated (500 V) digital input connection pairs are available from the signal I/O connector on -PDISO Series devices. Each signal is applied to a bridge rectifier so that the input is not polarity-sensitive. External -PDISO Series devices require between 6.5 V and 12.5 V of external power. - Series and -ERB Series devices require between 6.0 V and 12.5 V of external power. An external power connection using the included external power supply is required to activate relays and s, and to run tests in software. -PDISO Series devices, - Series devices, and the -ERB0 are powered by a 9 VDC nominal, 1.0 A external power supply (CB-PWR-9) that ships with each device. The -ERB2 is powered by an external 9 V, 3 A regulated power supply (CB-PWR-9V3A) that ships with the device. Daisy Chaining Multiple Devices MCC high-voltage/relay DIO devices can be optionally daisy chained to connect to the bus through the high-speed hub on the host device -PDISO Series, - Series, or -ERB Series. Up to four MCC devices can be daisy chained using a single port on the PC. Use the supplied cable or an equivalent cable when daisy chaining MCC Series products. When daisy chaining MCC high-voltage/relay DIO devices, make sure adequate power is provided to each connected device. Voltage Drop A drop in voltage occurs with each device connected in a daisy chain configuration. The voltage drop between the power supply input and the daisy chain output is 0.5 V maximum. Factor in this voltage drop when configuring a daisy chain system to ensure that at least 6.0 VDC is provided to the last device in the chain. Supply Current The following devices may require addition external power adapters depending on the number of connected devices: Device -PDISO Series -ERB0 -ERB2-2 -0 External Consumption (All s/ Modules On) Draws 20 ma from the 1 A supply Draws 750 ma from the 1 A supply Draws 1.5 A from 3 A supply Draws 00 ma from the 1 A supply Draws 300 ma from the 1 A supply Some devices may require their own external power supply in a daisy chain configuration. If unsure as to how much current an application requires, MCC recommends providing separate power to each connected device. Measurement Computing (50) 96-5100 2 info@mccdaq.com mccdaq.com

DIO High Voltage and Software Software Support The -PDISO, -ERB, and - Series devices are supported by the software in the table below. DAQami Ready-to-Run Applications Data acquisition companion software with drag-and-drop interface that is used to acquire, view, and log data, and generate signals. DAQami can be configured to log analog, digital, and counter channels, and to view that data in real-time or post-acquisition on user-configurable displays. Logged data can be exported for use in Excel or MATLAB. Windows OS DAQami is included with the free MCC DAQ Software bundle (CD/download). Install DAQami and try the fully-functional software for 30 days. After 30 days, all features except for data logging and data export will continue to be available data logging and data export features can be unlocked by purchasing the software. InstaCal An interactive installation, configuration, and test utility for MCC hardware. Windows OS InstaCal is included with the free MCC DAQ Software bundle (CD/download). TracerDAQ and TracerDAQ Pro (-PDISO Series digital inputs only) Universal Library (UL) Virtual strip chart, oscilloscope, function generator, and rate generator applications used to generate, acquire, analyze, display, and export data. Supported features may vary by hardware. The Pro version provides enhanced features. Windows OS TracerDAQ is included with the free MCC DAQ Software bundle (CD/download). TracerDAQ Pro is available as a purchased software download. General-Purpose Programming Support Library for developing applications in C, C++, VB, C#.Net, VB.Net, and Python. Windows OS The UL is included with the free MCC DAQ Software bundle (CD/download). Linux driver Open-source Linux drivers are available for most MCC devices. Example programs are also provided. Application-Specific Programming Support ULx for NI LabVIEW A comprehensive library of VIs and example programs for NI LabVIEW that is used to develop custom applications that interact with most MCC devices. Windows OS ULx for NI LabVIEW is included with the free MCC DAQ Software bundle (CD/download). DASYLab MATLAB driver Icon-based data acquisition, graphics, control, and analysis software that allows users to create complex applications in minimal time without text-based programming. Windows OS DASYLab is available as a purchased software download. An evaluation version is available for 2 days. High-level language and interactive environment for numerical computation, visualization, and programming. The Mathworks Data Acquisition Toolbox allows users to acquire data from most MCC PCI and devices. Visit www.mathworks.com for more information about the Data Acquisition Toolbox. Measurement Computing (50) 96-5100 3 info@mccdaq.com mccdaq.com

DIO High Voltage and Specifications - -PDISO Series -PDISO: 2 screw terminals -PDISO/0: 0-pin connector -PDISO Series Block Diagram Differential Isolated Inputs Form C Outputs Inputs Inputs 0 to 0 to 7 7 Control Signal I/O Connector s 0 to 0 to 7 7 Control C Lo C Hi Control Registers 9 V Nominal External Monitor Regulator Controller 2.0 Interface Specifications All specifications are subject to change without notice. Typical for 25 C unless otherwise specified. -PDISO Series specifications Number: Contact configuration: FORM C (SPDT) NO, NC, and Common available at connector. Contact rating: 6 A @ 20 VAC or 2 VDC resistive (refer to Main Connector on page 5) Contact resistance: 100 mω max Operate time: 10 ms max Release time -PDISO: 5 ms max -PDISO/0: 10 ms max Vibration: 10 Hz to 55 Hz (dual amplitude 1.5 mm) Shock: 10 G (11 ms) Dielectric isolation: 500 V (1 minute) Life expectancy: 10 million mechanical operations, min on RESET state: Not energized. NC in contact to Common. Isolated inputs Number: Isolation: 500 V Resistance: 1.6 KΩ min Voltage range (DC) Input high: +5.0 VDC min or 5.0 VDC min Input low: +1.5 VDC max or 1.5 VDC max Input range: 30 VDC max Voltage range (AC with filter) Input high: 6.0 Vrms min (50 Hz to 1000 Hz) Input low: 1.5 Vrms max (50 Hz to 1000 Hz) Response Filter disabled: 20 µs Filter enabled: 5 ms Filters Time constant: 5 ms (200 Hz) Filter control: Software-selectable for each input. -up /reset: Filters disabled +5 V input voltage range:.75 V to 5.25 V +5 V supply current: All modes of operation: 10 ma max External power input: 9 V nominal External power supply (required): MCC p/n CB-PWR-9: 9 V ±10% @ 1 A Voltage supervisor limits - PWR LED 6.5 V > Vext or Vext > 12.5 V: PWR LED = Off (power fault) -PDISO Series devices monitor the external +9 V power supply voltage with a voltage supervisory circuit. If this power supply exceeds its specified limit, the PWR LED turns off, indicating a power fault condition. 6.5 V Vext < 12.5 V: PWR LED = On External power consumption All relays on, 100 ma downstream hub power: 20 ma typ, 900 ma max All relays off, 0 A downstream hub power: 200 ma typ, 230 ma max Measurement Computing (50) 96-5100 info@mccdaq.com mccdaq.com

DIO High Voltage and Specifications - -PDISO Series External power output External power output - current range:.0 A max The daisy chain power output option allows multiple MCC products with a hub output port to be powered from a single external-power source in a daisy-chain fashion. The voltage drop between the device power supply input and the daisy-chain output is 0.5 V maximum. Users must plan for this drop to assure the last device in the chain receives at least 6.5 VDC. External power output: Voltage drop between power input and daisy chain power output: 0.5 V max Compatible cable(s) for daisy chain: C-MAPWR-x: x = 2, 3, or 6 feet Specifications Type-B connector: Input device type: 2.0 (full-speed) Device compatibility: 1.1, 2.0 -PDISO: Hardware revision F and later are also compatible with 3.0. The revision is indicated on the part number label on the housing 19721X-01 where X is the hardware revision. -PDISO/0: Hardware revision C and later are also compatible with 3.0. The revision is indicated on the part number label on the housing 19722X-01 where X is the hardware revision. Type-A connector: Downstream hub output port hub type: Supports 2.0 high-speed, full-speed and low-speed operating points; self-powered, 100 ma max downstream VBUS capability Compatible products: MCC products with a hub output port cable type (upstream and downstream): A-B cable, UL type AWM 2527 or equivalent (min 2 AWG VBUS/GND, min 2 AWG D+/D-) cable length: 3 meters max Mechanical -PDISO dimensions (L W H) PCB: 30.3 121.9 20.0 mm (12.0. 0. in.) Enclosure: 32.9 125.7 5.9 mm (13.5.95 2.32 in.) -PDISO/0 dimensions (L W H) PCB: 30.3 121.9 17. mm (12.0. 0.7 in.) Enclosure: 32.9 125.7 5.9 mm (13.5.95 2.32 in.) Environmental Operating temperature range: 0 C to 70 C Storage temperature range -PDISO: -0 C to 100 C -PDISO/0: -0 C to 5 C Humidity: 0% to 95% non-condensing Main Connector -PDISO Connector type: Screw terminal Wire gauge range: 12 AWG to 22 AWG -PDISO/0 Connector type: P1: 0-pin header Compatible cables C0FF-x: 0-conductor ribbon cable, female both ends, x = length in feet. C0-37F-x: 0-pin IDC to 37-pin female D connector, x = length in feet. Compatible accessory products Using the C0FF-x cable: CIO-MINI0 Using the C0-37F-x cable: CIO-MINI37 Max current: 1 A -ERB0 Block Diagram 9.0 V External Monitor Regulator Channel 1 relay Screw terminal NC C NO driver Channel 2 7relay Channel 3 6relay NC NO 6 7 Interface Microcontroller Channel 5relay Channel 5 relay NC C NO 5 NC C NO Load driver Channel 6 3relay Channel 7 2relay NC C NO 3 NC C NO 2 Switch S1 (inv/non-inv) Switch S2 (pull-up/down) Channel 1relay NC C NO 1 Measurement Computing (50) 96-5100 5 info@mccdaq.com mccdaq.com

1 2 3 5 6 7 9 DIO High Voltage and Specifications - -ERB Series -ERB2 Block Diagram Screw terminal 2 2 driver 23 22 23 22 9.0 V External 21 20 20 21 Monitor driver 19 1 17 17 1 19 Regulator 16 15 15 16 1 1 13 13 Interface Microcontroller driver 12 11 10 10 11 12 9 Switch S1 (inv/non-inv) Switch S2 (pull-up/down) l-up/down) 7 6 driver 5 3 2 1 -ERB Series Output Specifications Number of relays -ERB0: -ERB2: 2 configuration -ERB0: 2 banks of -ERB2: 2 banks of and 2 banks of Contact configuration -ERB0: Form C (SPDT) normally open (NO), normally closed (NC) and common (C) available at screw terminals -ERB2: 2 FORM C (SPDT) NO, NC and C available at screw terminals Contact rating: 5 A @ 20 VAC or 2 VDC resistive Contact resistance: 100 mω max (initial value) Operate time: 10 ms max Release time: 5 ms max Vibration: 10 Hz to 55 Hz (dual amplitude 1.5 mm) Shock: 10 G (11 ms) Dielectric isolation Between relay open contact: 300 VAC, 50/60 Hz (1 minute) Between PCB output lines: 500 VAC, 50/60 Hz (1 minute) Life expectancy: 10 million mechanical operations, min on RESET state S2 = pull-up: Energized. NO in contact with Common S2 = pull-down: Not energized. NC in contact with Common control logic polarity: User-configurable per bank through switch S1 for invert or non-invert (default). Switch settings for polarity can be read back with software over the bus. Switch settings do not affect the power on condition. Non-invert mode: When 0 is written or read back via the bus, relays are not energized. Invert mode: When 0 is written or read back via the bus, relays are energized. Pull-up/pull-down (controls relay power on state): User-configurable per bank through switch S2 for pull-down (default) or pull-up. Switch settings can be read back with software. Pull-down puts the relays in non-energized mode on power up. Pull-up puts the relays in energized mode on power up. +5 V input voltage range:.75 V min to 5.25 V max +5 V supply current (all modes of operation): 10 ma max Voltage supervisor limits - PWR LED 6.0 V > Vext or Vext > 12.5 V: PWR LED = Off (power fault) 6.0 V Vext < 12.5 V: PWR LED = On The daisy chain power output option allows multiple MCC Series products with a hub output port to be powered from a single external power source in a daisy chain fashion. The voltage drop between the device power supply input and the daisy chain output is 0.5 V max. Users must plan for this drop to assure the last device in the chain receives at least 6.0 VDC. External power consumption All relays on, 100 ma downstream hub power -ERB0: 750 ma typ, 50 ma max -ERB2: 1.5 A typ, 1. A max All relays off, 100 A downstream hub power -ERB0: 170 ma typ, 200 ma max -ERB2 230 ma typ, 270 ma max Measurement Computing (50) 96-5100 6 info@mccdaq.com mccdaq.com

DIO High Voltage and Specifications - -ERB Series External Input External power input: +6.0 VDC to 12.5 VDC (9 VDC power supply included) External power supply (included) -ERB0 MCC p/n CB-PWR-9: 9 V ±10% @ 1 A -ERB2 MCC p/n CB-PWR-9V3A: 9 V ±10% @ 3 A External Output External power output (current range):.0 A max External power output (voltage drop between power input and daisy chain power output: 0.5 V max -ERB Series devices monitor the external +9 V power supply voltage with a voltage supervisory circuit. If this power supply exceeds its specified limit, the PWR LED turns off, indicating a power fault condition. Compatible cable for daisy chain: MCC p/n C-MAPWR-x (x = 2,3, or 6 feet ) Specifications Type-B connector: Input device type: 2.0 (full-speed) Device compatibility: 1.1, 2.0 -ERB0: Hardware revision E and later are also compatible with 3.0. The revision is indicated on the part number label on the housing 193776X-01L where X is the hardware revision. -ERB2: Hardware revision G and later are also compatible with 3.0. The revision is indicated on the part number label on the housing 193773X-01L where X is the hardware revision. Type-A connector: Downstream hub output port hub type: Supports 2.0 high-speed, full-speed and low-speed operating points; self-powered, 100 ma max downstream VBUS capability Compatible products: MCC Series devices cable type (upstream and downstream): A-B cable, UL type AWM 2527 or equivalent (min 2 AWG VBUS/GND, min 2 AWG D+/D-). cable length: 3 meters max. Contact Pull-Up/Down Option s NO contact pull-up (to +5 V)/pull-down, user installed -ERB0: R1, R3, R5, R7, R10, R12, R1, R16 -ERB2: R35, R36, R1, R3, R5, R7, R9, R51, R7, R9, R91, R93, R96, R9, R100, R102, R103, R105, R107, R109, R112, R11, R116, R11 s NC contact pull-up (to +5 V)/pull-down, user installed -ERB0: R2, R, R6, R, R9, R11, R13, R15 -ERB2: R37, R0, R2,R, R6, R, R50, R52, R, R90, R92, R9, R95, R97, R99, R101, R10, R106, R10, R110, R111, R113, R115, R117 Mechanical -ERB0 dimensions (L W H) PCB: 203.2 121 20.0 mm (.0. 0. in.) Enclosure: 21.3 125.7 5.9 mm (9.50.95 2.32 in.) -ERB2 dimensions (L W H) PCB: 31. 121 20.3 mm (17.0. 0. in.) Enclosure: 2.6 125.7 5.9 mm (19.00.95 2.32 in.) Main Connector Connector type: Screw terminal Wire gauge range: 12 to 22 AWG Environmental Operating temperature range: 0 to 70 C Storage temperature range: -0 to 100 C Humidity: 0% to 95% non-condensing -0 Block Diagram 9.0 V External Monitor Switch S1 (I/O Type) Regulator s 1 to (Port C LO) Load + - + - + - + - + - + - + - + - 2 1 7 6 5 3 s 5 to (Port C HI) Bidiectional Buffer Bidiectional Buffer Microcontroller 500 ma 2.0 Compliant Interface Screw Terminal Switch S3 (Pull-Up/Down) Switch S2 (Inv/Non-Inv) Measurement Computing (50) 96-5100 7 info@mccdaq.com mccdaq.com

DIO High Voltage and Specifications - - Series -2 Block Diagram Load Screw terminal + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - 2 1 22 21 20 19 1 17 16 15 1 13 12 11 10 9 7 6 5 3 2 23 Module 1 Module 5 Module 9 Module 13 Module 17 Module 21 Module 2 Module 6 Module 10 Module 1 Module 1 Module 22 Module 3 Module 7 Module 11 Module 15 Module 19 Module 23 Module Modules 1- (Port A) Module Module 12 Modules 9-16 (Port B) Module 16 Module 20 Modules 17-20 (Port CL) Module 2 Modules 21-2 (Port CH) Switch S1 (I/O Type) 9.0 V External Monitor Regulator Microcontroller Switch S3 (Pull-Up/Down) 500 ma 2.0 Compliant Interface Switch S2 (Inv/Non-Inv) - Series I/O Module Configuration -0 Modules 1-: Selectable with switch S1 in the CL position as either input or output (default) s. Switch settings for direction can be read back with software. Do not mix input and output s within this bank of four. Modules 5-: User-selectable with switch S1 in the CH position as either input s or output (default) s. Switch settings for direction can be read back with software. Do not mix input and output s within this bank of four. -2 Modules 1-: Selectable with switch S1 in the A position as either input or output (default) s Switch settings for direction can be read back with software. Do not mix input and output s within this bank of eight. Modules 9-16: Selectable with switch S1 in the B position as either input s or output (default) s. Switch settings for direction can be read back with software. Do not mix input and output s within this bank of eight. Modules 17-20: Selectable with switch S1 in the CL position as either input or output (default) s. Switch settings for direction can be read back with software. Do not mix input and output s within this bank of four. Modules 21-2: Selectable with switch S1 in the CH position as either input or output (default) s. Switch settings for direction can be read back with software. Do not mix input and output s within this bank of four. I/O logic polarity: Selectable with switch S2. Switch settings for polarity can be read back with software. Default to non-inverted. For input s, invert mode returns a 1 when is active; non-invert mode returns a 0 when is active. For output s, invert mode allows users to write a 1 to activate the ; non-invert mode allows users to write a 0 to activate the. Pull-up/pull-down on digital I/O lines: Configurable with switch S3 with 2.2 kω resistor network. Switch settings for pull-up/pull-down selection can be read back with software. Default to pull-up. Switch settings are applicable during power up conditions of output s only. Modules are active Low. When switch to Pull-up, s are inactive on power up. When switched to pulldown, s are active on power up. +5 V input voltage range:.75 V min to 5.25 V max +5 V supply current (all modes of operation) -0: <100 ma -2: 10 ma max External power supply (included; required for -2): MCC p/n CB-PWR-9 9 V ±10% @ 1.0 A Voltage supervisor limits - PWR LED 6.0 V > Vext or Vext > 12.5 V: PWR LED = Off (power fault) 6.0 V Vext < 12.5 V: PWR LED = On Measurement Computing (50) 96-5100 info@mccdaq.com mccdaq.com

DIO High Voltage and Specifications - - Series External power consumption All s on, 100 ma downstream hub power -0: 300 ma typ, 360 ma max -2: 00 ma typ, 950 ma max All s off, 0 ma downstream hub power -0: 10 ma typ, 220 ma max -2: 200 ma typ, 220 ma max External Input External power input: +6.0 VDC to 12.5 VDC (9 VDC power supply included) External power supply (included; required for -2) MCC p/n CB-PWR-9: 9 V ±10% @ 1 A External Output External power output (current range):.0 A max - Series devices monitor the external +9 V power supply voltage with a voltage supervisory circuit. If this power supply exceeds its specified limit, the PWR LED turns off, indicating a power fault condition. External power output (voltage drop between power input and daisy chain power output: 0.5 V max The daisy chain power output option allows multiple MCC boards to be powered from a single external power source in a daisy chain fashion. The voltage drop between the power supply input and the daisy chain output is 0.5 V max. Users must plan for this drop to assure the last in the chain receives at least 6.0 VDC. Compatible cable for daisy chain: MCC p/n C-MAPWR-x (x = 2,3, or 6 feet ) Specifications Type-B connector: Input device type: 2.0 (full-speed) Device compatibility: 1.1, 2.0 - Series revision F and later are also compatible with 3.0. The revision determined from the part number label on the housing as follows: -0: The part number label on the housing shows as 193779X-01L, where X is the hardware revision -2: The part number label on the housing shows as 9372X-01L, where X is the hardware revision Type-A connector: Downstream hub output port hub type: Supports 2.0 high-speed, full-speed and low-speed operating points; self-powered, 100 ma max downstream VBUS capability Compatible products: MCC Series devices cable type (upstream and downstream): A-B cable, UL type AWM 2527 or equivalent (min 2 AWG VBUS/GND, min 2 AWG D+/D-). cable length: 3 meters max. Digital I/O Transfer Rates Digital I/O transfer rate (software paced): System dependent, 33 to 1000 port reads/writes or single bit reads/writes per second typ. Mechanical -0 dimensions (L W H) PCB (without s):.0. 0.5 in. (203.2 121.9 22.5 mm) Enclosure: 9.50.95 2.32 in. (21.3 125.7 5.9 mm) -2 dimensions (L W H) PCB (without s): 31. 121.9 22.5 mm (17.0. 0.5 in.) Enclosure: 2.6 125.7 5.9 mm (19.00.95 2.32 in.) Main connector Connector type: Screw terminal Wire gauge range: 12 to 22 AWG Digital I/O Modules Specifications for the s available for the - Series are listed below. Digital Input Sensing Modules MCC part number Input type Isolation voltage -IAC-05 AC 000 Vrms -IAC-05A High voltage AC 000 Vrms Input voltage range 90-10 VAC/DC 10-20 VAC/DC Input current @ max line Turn-on time Turn-off time ma 20 ms 20 ms 6 ma 20 ms 20 ms -IDC-05 DC 000 Vrms 3-32 VDC 1 ma 0.20 ms 0.0 ms -IDC-05NP Non-polarized, AC or DC 000 Vrms Digital Output Switching Modules MCC part number Output type* Isolation voltage -OAC-05 AC 000 Vrms -OAC-05A AC 000 Vrms 15-32 VAC, 10-32 VDC Load voltage range 2-10 VAC 2-20 VAC 1 ma 5 ms 5 ms Load current range Turn-on time Turn-off time 0.03-3.5 A.33 ms.33 ms 0.03-3.5 A.33 ms.33 ms -ODC-05 DC 000 Vrms 3-60 VDC 0.02-3.5 A 20 µs 50 µs -ODC-05A DC 000 Vrms -200 VDC 0.02-3.5 A 75 µs 750 µs * SPST, normally open Measurement Computing (50) 96-5100 9 info@mccdaq.com mccdaq.com

DIO High Voltage and Ordering Order Information Hardware Part No. -PDISO -PDISO/0-0 -2 -ERB0 -ERB2 Description Accessories and Cables Part No. CB-PWR-9 CB-PWR-9V3A PS-9V1AEPS230V C-MAPWR-x CIO-MINI0 -based eight Form C relay and eight isolated highvoltage input interface device. Includes power supply and cable -based eight Form C and eight isolated highvoltage input interface device with 0-pin connector. Includes power supply and cable. -based solid-state eight I/O interface device. Includes power supply and cable. -based solid-state 2 I/O interface device. Includes power supply and cable. -based -channel electromechanical relay interface device. Includes power supply and cable. -based 2-channel electromechanical relay interface device. Includes power supply and cable. Description Replacement power supply, 9 V, for -PDISO Series, - Series, and -ERB0 non interchangeable US plug Replacement power supply, 9 V, for -ERB2 Replacement 230 V power supply, 9 V output, for -PDISO Series, - Series, and -ERB0 interchangeable plugs available separately Cable, daisy-chain, power, for devices with built-in expansion ports x = 2, 3, or 6 ft. Universal screw-terminal board, 37-pin Digital I/O Modules (- Series Only) Part No. -IAC-05 -IAC-05A -IDC-05 -IDC-05NP -OAC-05 -OAC-05A -ODC-05 -ODC-05A Description AC sense input, 90 to 10 VAC/VDC AC sense input, 10 to 20 VAC/VDC DC sense input, 3 to 32 VDC DC sense input, 10 to 32 VDC non-polarized AC switch output, 2 to 10 VAC, 3.5 A @ 120 VAC, SPST normally open AC switch output, 2 to 20 VAC, 3.5 A @ 20 VAC, SPST normally open DC switch output, 3 to 60 VDC @ 3.5 A, SPST normally open DC switch output, to 200 VDC @ 3.5 A, SPST normally open Software also Available from MCC Part No. DAQami TracerDAQ Pro * DASYLab Description Easy-to-use advanced data logging application to acquire, view, and log data Out-of-the-box virtual instrument suite with strip chart, oscilloscope, function generator, and rate generator professional version Icon-based data acquisition, graphics, control, and analysis software * TracerDAQ Pro only supports -PDISO Series digital inputs; it does not support -ERB Series or - Series devices. Measurement Computing (50) 96-5100 10 info@mccdaq.com mccdaq.com DS -High-Voltage--DIO June 2017. Rev 2 Measurement Computing Corporation