MRC 7000 Proven Recording Reliability that Became the Industry Standard!

Similar documents
UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

PXR Series Advanced Self-Tuning Temperature and Process Controllers

/8 DIN Motorized Valve Controller

/8 DIN Universal Process Indicator

100mm Process Indicator Recorder

SX90 Process Controller

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

MODCELL 2050R Single Loop Controllers

UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Eclipse Combustion Universal Digital Controller

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

Wall-/Pipe Mounted Universal Process Indicator

Universal power supply

C160 Wall-/Pipe Mounted Universal Process Indicator

Temperature, Process &

Inform IT Single Pen Circular Chart Recorder

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

Basic Temperature and Limit Controllers. Provide Economical Solution for a Wide Range of Applications SPECIFICATION SHEET

Basic Temperature and Limit Controllers

F 1559 % ALM RSP OUT SP Features

OLS VT10 SERIES STANDARD DUAL DISPLAY PID AUTOTUNE RAMP-TO-SETPOINT ULC, UL, CE (4810) AUTO / MANUAL 15 SECURITY OPTIONS UNIVERSAL INPUT

Trident and Trident X2 Digital Process and Temperature Panel Meter

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

Universal Process Controller

Control IT. /16 DIN Controller/Alarm Unit. Data Sheet SS/C50_7 C50. C50 the 1 /16 DIN controller to suit your simplest applications

NOW A PRODUCT! 1/4 DIN Auto/Manual Station. The Interface Solution Experts. The Interface Solution Experts. PS532 V6 March 2017

UDC1200 & UDC1700 Universal Digital Controllers Series Micro-Pro Specifications

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

SERIES 59. Microprocessor Temperature Controller with Digital Display and RTD, Thermistor or Thermocouple Sensing

Basic Analog/Digital Controllers & Indicators. General-Purpose Limit, Valve Motor Drive, Temperature & Process Controllers. Basic & High-End Profilers

The CAL range of temperature controllers

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

FICHA TÉCNICA DE PRODUTO

Tempco Instruction Manual

DPR 100 A/B Analog Scales

MLC 9000 Bus Compatible PID

Temperature/Process Controllers Manual

LAUREL ELECTRONICS, INC.

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

ABB Instrumentation. Specification DataFile. COMMANDER 1900 a rugged, reliable recorder with the full capability to meet your application needs

PRICE BOOK. September 2015

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

FICHA TÉCNICA DE PRODUTO

PRICE BOOK. January 2019

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

P/N /02 Rev. C ECO # Model 1440 Microprocessor-based Temperature Controller Installation and Operation Manual

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

General Specifications. P2-08THM Analog Input

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

Meter Scanner & Controller

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

PID with. Controllers W A T L O W CPC400 SERIES. Multi-Loop

NOTE: Controller must be mounted to minimum of 2 ft2 (0.2m2) 20 gauge metal panel with both sides radiating.

Temperature Controller E5C4

ProVU 4 Advanced Temperature & Process Controller

C1900 Series Circular Chart Recorder. C1900 a rugged, reliable recorder with the full capability to meet your needs

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

Neon pr. ph/ ORP measurement. Applications. Description

DIGITAL INDICATING CONTROLLER

3500/53 Electronic Overspeed Detection System

JUMO itron 04/08/16/32 Compact microprocessor controllers

1/4 DIN PROCESS CONTROLLER

C1300 Advanced Circular Chart Recorder. C1300 dependable recording in a rugged, functional instrument

LCI User Manual mantracourt.com

Tachometer Panel, PE3

Color Printer Microjet Recorder Series

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

West Instruments. The MLC compact multi-loop controller... MLC ends the control or integration compromise

TECHNICAL DATA SHEET. ProVU 4 Advanced Temperature Controller. Features. Description

Temperature Measurement

Strip Chart Recorders Specification Sheet

UDC 3500 FEATURES AND BENEFITS

TC 34 MICROPROCESSOR-BASED DIGITAL ELECTRONIC COUNTER

Temperature, Process &

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

PD765 TRIDENT. Trident Series Process & Temperature Meters.

CDD Carbon Dioxide Transmitter

Carbon Monoxide (CO) Gas Detection and Control System

ALM CHN RSP OUT F SP 164.8

LAUREL. MAGNA Series Large Digit Displays for Counter / Totalizer Pulse Input ELECTRONICS, INC. Features. Description

PD765 TRIDENT. Trident Series Process & Temperature Meters.

ABB MEASUREMENT & ANALYTICS DATA SHEET. C1300 Advanced circular chart recorder

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

LCI Load Cell Junction Box with Fault Monitor

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

ABB Instrumentation. Specifications. COMMANDER 505 Advanced Process Controller

Andover ContinuumTM Infinet II

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

SED2 Variable Frequency Drives

Safety Monitoring Relays

Transcription:

Data Sheet Recorder//Profiler DESCRIPTION The MRC7000 Recorder/ is a microprocessor based circular chart instrument capable of measuring, displaying, recording and controlling up to two process variables from a variety of inputs. Record and control functions, alarm settings and other parameters are easily configured via the keys on the front cover and self-prompting displays. All user entered data can be protected against unauthorized changes via the MRC7000 Enable Mode security system. APPLICATIONS: Record, profile and security functionality for reliability in diverse industry applications Process Validation Trend Analysis Regulatory Compliance Product Safety - Temperature - ph Level INDUSTRIES Oven, chamber, furnaces, heat treating, food processing, harsh water environments FEATURES/BENEFITS Micro-based recording with controller or profiler options with programming setpoint profile capability in one instrument Two displays allow you to see critical process values at the same time (on 2 pen units) Easy, straightforward programming allows you to configure your recorder with a logical step-by-step process using a simple keypad Optional true time based profiling capability puts you in control of your process Reliability maintenance free recording for years to come

Hollowshaft, Recorder//Profiler Incremental Encoders SPECIFICATIONS STANDARD FEATURES Functionality: Digital; Available in four configurations: Record only, High/Low limit optional, Controlling Recorder, Profiling Controlling Recorder. Display: One digital display (std.); 2nd display with 2 pen (optional); 0.56 high, red, seven segment LED; 3 button keypad; automatic and decimal point positioning. Two alarm indications possible per pen. Status Indicators: 7 LED status indicators Out 1, 2, Man (Ramp, Soak or Seg 1 6 for profiler option only), one green LED pen 2 indicator, ALRM1/ALRM2 with red LEDs. Chart: 10 circular chart; 100 charts furnished with each instrument. Unless otherwise specified, charts shipped with instrument are 0 100 range. 24 hour rotation default setting. Chart Drive: DC Stepper Motor. Chart Rotation: User configurable from 0.1 and 999.9 hours per revolution. Chart Range: Bottom and top of span 9999 to 9999 units. Pen Type: One or two disposable fiber tip pen. Pen Color: Pen 1 (red); Pen 2 (green). Memory Backup: Battery; 5 year normal life. Construction/Enclosure: Structural foam enclosure with plastic cover standard. OPERATING CHARACTERISTICS Operating Temp: 32 to 122 F (0 to 50 C). Storage Temp: 40 to 149 F ( 40 to 65 C). Humidity: 0% to 90% non-condensing R.H. Vibration: 0.5 to 100Hz @ 0.2g. Electro Static Discharge: No effect from 5000V static charge over the entire area. RFI: Degradation due to RF fields to recording and output accuracy to 8% at spot frequencies in the range of 100 1000MHz. PROCESS CONTROL U L LISTED 88BO ELECTRICAL Power Consumption: 25VA max. Line Voltage: 115V or 230VAC ±10%, 50 60Hz. OUTPUTS CONTROL OUTPUTS: Relay: SPST/SPDT; 115VAC 5.0A Resistive, 1/ 8HP, 250VA; 230VAC 2.5A Resistive, 1/8HP, 250VA. SSR Driver: Open collector output; short circuit protected @ 100mA max; provides 4VDC @ 20mA or 3VDC @ 40mA. Current: 0 20mA or 4 20mA; 0 650 ohm maximum load. ALARM/EVENT OUTPUTS (Options): Relay: SPST/SPDT: 115VAC 5.0A resistive, 1/ 8HP, 250VA. 230VAC 2.5A resistive, 1/8HP, 250VA. SSR Driver: Open collector output; short circuit protected @ 100mA max; provides 4VDC @ 20mA or 3VDC @ 40mA. Process Alarm: Direct (High) or Reverse (Low) 9999 to 9999 units. Deviation Alarm: Direct (Deviation above setpoint) or Reverse (Deviation below setpoint) 3000 to 3000 units. Deviation Band Alarm: 1 to 3000 units. Alarm Hysteresis: 0 300 units (width of hysteresis band). INPUTS Thermocouple: J, K, T, R, S, B, C, E, N. RTD: 100 ohm, platinum; 0.00385 ohms/ ohm/ C. Volts: 0 5 VDC or 1 5VDC. DC Millivolts: 0 25mV, 0 50mV or 10 50mV. DC Milliamps: 4 20mA or 0 20mA used with appropriate shunt resistor. Remote Setpoint Input (optional): 0 5VDC, 1 5VAC, 0 20mA, 4 20mA (recording controller only); accommodated with an internal 249 ohm jumper selectable shunt resistor. PERFORMANCE GENERAL: Input Measurement Error: Type J, K, T, E, N, C, T/ C and RTD ±0.25% of reading plus 1 degree @ 25 C; Type R, S, B, C, T/C ±0.25% of span @ 25 C. Ambient Temperature Error: 0.01% of span per degree C deviation from 25 C. Cold Junction Compensation Error: ±0.2% @ 25 C. Cold Junction Compensation Rejection: ±0.04% deviation from 25 C. Common Mode Rejection: 90dB minimum; 24VAC maximum for RTD input; 115VAC max for other inputs. Normal Mode Rejection: 85dB minimum @ 60Hz or greater. Chart Accuracy: Recording: 0.5% of span. Chart Rotation: ±0.5% of rotation time. Process Value Output Error Limit: 0.5% of span. Record Error Limit: ±0.5% of chart span or better typically; ±1.0% of chart span maximum. CONTROL PARAMETERS (optional): Proportional Band Output 1/Output 2: 1 to 3000 units. Manual Reset (Integral): 1500 to 1500 units. Auto Reset (Integral): 0.0 100.0 repeats/ minute. Rate Derivative: 0.0 10.0 minutes. Cycle Time Output 1/Output 2: 1 to 240 seconds. Position Proportioning Sensitivity: 0.0 50.0%. ON/OFF Hysteresis: 0 300 units (width of hysteresis band). First /Second Output Position: 1000 to 1000 units. Control Action: Direct or Reverse. Automatic Transfer Function: User-selectable to transfer from manual to automatic control when setpoint is reached; can be disabled. Anti-Reset Windup: Auto-reset is disabled when the process is outside of the proportional band. Auto/Manual: Bumpless transfer. Manual Output: 0 100%. Output Limiting: High/Low 0 100%. Setpoint Limiting: High/Low Limit: 9999 to 9999 units.

Hollowshaft, Recorder//Profiler Incremental Encoders SPECIFICATIONS (Continued) PERFORMANCE (continued) PROFILE PARAMETERS (optional): Programmable Profiles: 8 user-programmable profiles. Segments: 1 6 segments per profile. Ramp and Soak: 1 ramp and soak per segment. Profile Time Base: User-selectable; Choose from hours and tenths (HHH.T); hours and minutes (HH.MM) or minutes and seconds (MM.SS). Profile Interruption Action: Upon return of AC power either go to OFF mode, continue profile, go to HOLD mode, or restart profile at beginning. Profile Loop Count: 1 9999; 0 = continuous. Profile End Control: User-selectable; hold at last setpoint; Abort (all outputs off or 0%); transfer to another profile. Assured Soak: Deviation Hold after Ramp Up or Down; 1 3000 units; 0 = No Auto Hold. Pen Profiling Configuration: Pen 1 only or Pen 1 and 2. Remote Run/Hold (optional): User-selectable; override Run/Hold key; allow Run/Hold key function. Event Output(s): Up to 3 event outputs possible; each event can be set on or off for each ramp and soak. COMMUNICATIONS INTERFACES Communications Port: RS-422/485 serial, half duplex. Protocol: Partlow ASCII Bit Rate: User-configurable 300, 600, 1200, 2400, 4800 or 9600/sec. Address: User-configurable for each pen 0 99. RATINGS/AGENCY APPROVALS Safety: UL 1092 File E67237; CSA Spec C22.2 File LR39885. Immunity: Optional CE compliance. Other: ISO 9002 registered. PROTECTION NEMA 3 enclosure optional; CE compliance optional. Enable Mode security system option. PHYSICAL DIMENSIONS Width: 15.13 (384mm). Depth: 3.63 (92mm). Height: 13.19 (335mm). Weight: 20 lbs (9.1kg). OPTIONS/ACCESSORIES Choice of pen, thermocouple input and SSR driver outputs (see matrix for details). RS-485 communication option. 24V DC power supply option. 115 or 230VAC input option. NEMA 3 protection optional; CE compliance optional. Enable Mode security system option. WARRANTY 3 years.

MODELS (Recorder Only) Code 1: Model 7 MRC7000 Recorder Code 2: Pen 1 1 Recorder Only 4 High or Low Limit Code 3: Pen 2 1 Recorder Only Code 4: Relay (SPST) 1 One SPST 2 Two SPST 4 Four SPST 6 Six SPST 7 One SPDT 8 Two SPDT 9 Two SPDT and Two SPST Code 5: SSR Driver 1 One 2 Two 4 Four 6 Six 8 Eight Code 6: 4-20mA Outputs 1 One 2 Two 3 Three 4 Four Code 7: Transmitter Power Supply 1 24VDC Regulated /Isolated Required Zeros 0 0 Code 8: Digital Communications 2 RS-485 Total Access Code 9: Enclosure Options 2 Cover (Plastic Windows) 4 Door Lock** 6 Sealed Conduit Connections 7 4 & 6 Combined** Code 10: Operating Voltage 1 115VAC 2 115/230VAC CSA APPROVED 4 115VAC 5 115/230VAC NOTE: 4-20mA inputs are accommodated using the 1-5V input and a 250 ohm Shunt Resistor, P/N 64411701 or the 10-50mA input and a 2.5 ohm Shunt Resistor, P/N 64411702 Order as Separate Line Item. High/low limit device is Factory Mutual approved. Code 11: Option Suffix BLANK - None N3 NEMA AW RTD Depression on Pen 2 AD 0/100 mvdc Input AE N3 plus AW CE CE Compliance Recorder//Profiler * Total quantity of SPST Relays and SSR Drivers must be less than or equal to eight. When SPDT Relays are included, the total must be less than or equal to six. With Limit, only 1 selectable Alarm is available. ** This option comes with a structural foam cover. N3 - NEMA type protection for wet environments.

MODELS (Recording /Profiler) * Total quantity of SPST Relays and SSR Drivers must be less than or equal to eight. When SPDT Relays are included, the total must be less than or equal to six. ** Applies to Model 73XXXXXXXXXX. *** This option comes with a structural foam cover. N3 - NEMA type protection for wet environments. NOTE: 4-20mA inputs are accommodated using the 1-5V input and a 250 ohm Shunt Resistor, P/N 64411701 or the 10-50mA input and a 2.5 ohm Shunt Resistor, P/N 64411702ea. Recorder//Profiler Code 1: Model Code 2: Pen 1 Code 3: Pen 2 Code 4: Relay (SPST) 7 MRC7000 Recording/ Profile 2 Recording 3 Recording Profile 1 Recorder 1 One SPST Only 2 Two SPST 2 Recording 4 Four SPST 6 Six SPST 7 One SPDT 8 Two SPDT 9 Two SPDT and Two SPST Code 5: SSR Driver 1 One 2 Two 4 Four 6 Six 8 Eight Code 6: 4-20mA Outputs 1 One 2 Two 3 Three 4 Four Code 7: Code 8: Code 9: Transmitter Pen 1 Auxiliary Pen 2 Auxiliary Power Supply Input Input Code 10: Code 11: Digital Enclosure Communications Options Code 12: Operating Voltage 1 24VDC Regulated /Isolated 1 Position Proportioning 2 Remote Setpoint 3 Remote Run/Hold** 1 Position Proportioning 2 Remote Setpoint 2 RS-485 Total Access 2 Cover (Plastic Windows) 4 Door Lock*** 6 Sealed Conduit Connections 7 4 & 6 Combined*** 1 115VAC 2 115/230VAC CSA APPROVED 4 115VAC 5 115/230VAC Order as Separate Line Item. Code 13: Option Suffix BLANK - None N3 NEMA AW RTD Depression on Pen 2 AD 0/100 mvdc Input AE N3 plus AW CE CE Compliance

Hollowshaft, Recorder//Profiler Incremental Encoders DIMENSIONS EC1 15.1" (384.2 mm) WIDTH OF COVER 2.5" (63.5 mm) 2.6" (65.9 mm) 9 32 DIA.(7.1mm) 12.6" 7.5" (320.7 mm) (190.5 mm) 13.5" (342.5 mm) 13.9" ( 354 mm) Panel cut-out for flush mounting Made in USA. * Specifications subject to change without notice in accordance with our DBS policy of continuous improvement. All product and brand names are trademarks of their respective companies. All rights reserved. Partlow brand and are trademarks of Danaher Industrial Controls Group. All rights reserved. 2005 DICG Corp. Partlow Brand MRC 7000 Data Sheet (5/05)