ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

Similar documents
FSM-510G Series Ethernet Management Switch Quick Start Guide

8~14-Port Managed Ethernet Switch

INDUSTRIAL POE SWITCH

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000

ROCKETLINX ES8508 ES8508 ES8508F ES8508-XT ES8508F-XT QUICK INSTALLATION GUIDE

Quick Start Guide Elinx ESW500 Series. Managed Din Rail Ethernet Switch

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

3018G/4518/5012G/5018G

Entry Line Industrial Gigabit Ethernet Bridging Converter, PoE+ optional 1x 10/100/1000Base-T, 1x 100/1000 SFP

Fig. 1: Entry Line Compact Gigabit Ethernet Converter

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

5 10/100TX w/ 4 PoE Injector Industrial Switch. User Manual

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

Numerics INDEX. 10/100/1000 ports cable lengths 2-4, B-6 connecting to 2-38, B-43 described /100 ports

Managed Industrial. Ethernet Switch GLM Series User Manual

LNX-1002C-SFP Series

IMC-21GA Quick Installation Guide

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

Manual Documentation Number EIR418-2SFP-T 0912m

Stride SE2 Series Unmanaged Industrial Ethernet Switches and Media Converters

MF BASE-T to 1000BASE-X INDUSTRIAL MEDIA CONVERTER WITH SFP SUPPORT INSTALLATION GUIDE

EDR-G902/G903 Quick Installation Guide

8-Port 10/100BASE-TX Hardened Ethernet Extender Switch

28-Port L2 Managed (Gigabit) Switch

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

I(P)GS-3208MGSFP I(P)GS-3208C I(P)GS-3204MGSFP I(P)GS-3008 IP30-rated Series

Lantech I(P)GS-0008B. 8 10/100/1000T (PoE at/af) Industrial Unmanaged Ethernet Switch I(P)ES-0008B

Perle SMI Media Converter Installation Guide

IES7110-2GS Series. Managed Industrial Ethernet Switch. User manual. Summarize. Panel layout. Packing list. Feature

IWMR-3002 Industrial Multifunction VPN Router w/up to 2x WiFi 11ac + up to 2 LTE 4G + 2/4 serial ports + 2 Gigabit Ethernet Switch

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Overview. Features CHAPTER

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

LNX-0702G-SFP Series

Quick Start Guide. Physical Description. The Port Status LEDs

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

IDS-409F Hardware Installation Guide Managed Industrial Ethernet Switches

PTC-101-M12 Hardware Installation Guide

Industrial Switches. 9 Industrial. Industrial Switch, 5 Ports 100Base-TX 554 Industrial Switch, 8 Ports 100Base-TX 555

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

Lantech. IPGS-0005T /100/1000T PoE at T Industrial Unmanaged Switch. User Manual

IPS-3110 Managed Industrial PoE Gigabit Ethernet Switch

Industrial 8-Port 10/100TX 802.3at PoE+ + 2-Port Gigabit TP/SFP Combo Ethernet Switch IFGS-1022HPT. User s Manual

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual

Quick Start Guide. Physical Description.

EDR-810 Series Quick Installation Guide

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

PTC-101 Quick Installation Guide

Industrial PoE Media Converter

Industrial 5-/8-Port 10/100TX Compact Ethernet Switch. ISW-500T/ISW-800T User s Manual

Manual Elinx EIR408-T. 8 Port-10/100/1000 Unmanaged Din Rail Ethernet Switch

Stride Industrial Ethernet Switches

IDS-509 Hardware Installation Guide Managed Industrial Ethernet Switches

SICOM3170 Series Managed. Traffic Ethernet Switch

EDS-G308 Series Quick Installation Guide

EDS-G205-1GTXSFP Quick Installation Guide

Hardened PoE Ethernet Switch

Industrial Switches Industrial Switches

Industrial 6-port unmanaged Gigabit PoE Ethernet switch with 4x10/100/1000Base-T(X) P.S.E. and

6 / 8 Port Gigabit Ethernet Switch with PoE+ optional with 2x SFP Slots

LNP-0501 Series. User Manual. 5-Port Industrial PoE+ Unmanaged Ethernet Switches with 4*10/100Tx (30W/Port) + 1*10/100Tx

Industrial 3-Port Fast Ethernet Media Converter Switches

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

Gigabit Ethernet Industrial Switch 10 Port with Ring- Redundancy and PoE

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

IDS-509-SFP Hardware Installation Guide Managed Industrial Ethernet Switches

Manual Elinx EIRHP305-T. 5 Ports10/100 with 4 PoE Ports Unmanaged Din Rail Ethernet Switch

The configuration of the features can be done by the network management or the integrated configuration switches.

10 & 18 port SNMP and Modbus/TCP Capable Ethernet Switches SEC310-2SFP-T, SEC318-2SFP-T

gigabit industrial ethernet user manual Models , ,

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

Industrial 8-Port 10/100/1000T + 2-Port 100/1000X SFP Ethernet Switch (-40~75 degrees C)

Industrial 10G/5G/2.5G/1G/100M Copper to 10GBASE-X SFP+ Media Converter

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v

Installation Guide. 100BASE-TX/100BASE-FX Fast Ethernet Media Converter NC-200FT/FC. -1-iIiNC-200FT/FC P/N:

INSTRUCTION MANUAL FMX-GE-1000 ETHERNET TO OPTICAL MEDIA CONVERTER

EN port managed Ethernet switch with 8x10/100Base-T(X) and 2xGigabit combo ports, SFP socket

IMC-P111FX / IMC-P111P Series

KFC-200. Installation Guide

System-vision DDM. Network connection. Monitoring and Configuration interface

Industrial Slim Type Fast Ethernet Rail Switch

Gigabit Ethernet 10 port Industrial Switch with Ring redundancy

Transcription:

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start Version 1.0, Dec 2014 Overview The Management Ethernet Switch solutions are designed for supporting standard industrial applications. Managed switches are easily to prioritize partition and organize user s network and provide reliable and good quality services. Models FSM-510G-2F L2+ Managed Switch FSM-510G-4F Total GE Ports 10 10 10/100/1000 BaseT(X) 8 6 100/1000 Base SFP 2 4 1

Safety Instructions When a connector is removed during installation, testing, or servicing, or when an energized fiber is broken, a risk of ocular exposure to optical energy that may be potentially hazardous occurs, depending on the laser output power. The primary hazards of exposure to laser radiation from an optical-fiber communication system are: Damage to the eye by accidental exposure to a beam emitted by a laser source. Damage to the eye from viewing a connector attached to a broken fiber or an energized fiber. Technical Specifications Model Ethernet Copper RJ45 Ports SFP (pluggable) Ports FSM-510G Series 10/100/1000 Mbps speed auto-negotiation MDI/MDIX Auto-crossover 100/1000Base SFP slot Fiber port connector LC typically for fiber (depends on module) Power Power input Input voltage range Maximum Power consumption Redundant Input Terminals; Reverse power protection +12-48 VDC 10.5W Environmental and Compliances Operating temperature -40 to +75 C Storage temperature -40 to +85 C Humidity Mechanical Ingress protection Dimension (without DIN rail clip) Installation option 5 to 95% RH (non-condensing) IP30 154mm(H) x 109mm(L) x 60mm(W) DIN-Rail mounting Wall mounting 2

Faceplate 10-Port series DIN-Rail Mounting Mounting step: 1. Screw the DIN-Rail bracket on with the bracket and screws in the accessory kit. 2. Hook the unit over the DIN rail. 3. Push the bottom of the unit towards the DIN Rail until it snaps into place. 3

1 2 Wall Mounting Mounting step: 1. Screw on the wall-mount plate on with the plate and screws in the accessory kit. The graph is for all series Ethernet Interface Connecting (RJ45 Ethernet) The switches provide two types of electrical (RJ45) and optical (mini-gbic) interfaces. Connecting the Ethernet interface via RJ45: To connect to a PC, use a straight-through or a cross-over Ethernet cable, To connect the FSM-510G switch to an Ethernet device, use UTP (Unshielded Twisted 4

Pair) or STP (Shielded Twisted Pair) Ethernet cables. ICPDAS FSM-510G series switch Quick Start The pin assignment of RJ-45 connector is shown in the following figure and table. Pin Assignment 1,2 T/Rx+,T/Rx- 3,6 T/Rx+,T/Rx- 4,5 T/Rx+,T/Rx- 7,8 T/Rx+,T/Rx- Ethernet Interface Connecting (Fiber, SFP) For a 100 Mbps fiber port available, please prepare the LC connectors or SC connectors (with the use of an optional SC-to-LC adapter). For a 1000 Mbps fiber port available, please use the mini-gbic SFP. These accept plug in fiber transceivers that typically have an LC style connector. They are available with multimode, single mode, long-haul or special-application transceivers. DANGER: Never attempt to view optical connectors that might be emitting laser energy. Do not power up the laser product without connecting the laser to the optical fiber and putting the cover in position, as laser outputs will emit infrared laser light at this point. 5

Power Connecting The switch can be powered from two power supply (input range 12V 58V). Insert the positive and negative wires into V+ and V- contact on the terminal block and tighten the wire-clamp screws to prevent the wires from being loosened. Note: 1. The DC power should be connected to a well-fused power supply. First Power Supply Second Power Supply Alarm Relay and Ground Connecting The alarm relay output contacts are in the middle of the DC terminal block connector as shown in the figure below. By inserting the wires and set the DIP switch of the respective Port Alarm to ON, the relay output alarm will detect any port failures, and form a short circuit. The alarm relay out is Normal Open. Ground Connector 6

Console Connection The Console port is for local management by using a terminal emulator or a computer with terminal emulation software. DB9 connector connect to computer COM port Baud rate: 115200bps 8 data bits, 1 stop bit None Priority None flow control To connect the host PC to the console port, a RJ45 (male) connector-to-rs232 DB9 (female) connector cable is required. The RJ45 connector of the cable is connected to the CID port of IVS-500; the DB9 connector of the cable is connected to the PC COM port. The pin assignment of the console cable is shown below: 7

Connect & Login to FSM-510G 1. Connecting to FSM-510G Ethernet port (RJ45 Ethernet port). 2. Factory default IP: 192.0.2.1 3. Login with default account and password. Username: admin Password: (none) CLI Initialization & Configuration (Optional) 1. Connecting to FSM-510G Ethernet port(rj45 Ethernet port) 2. Key-in the command under Telnet: telnet 192.0.2.1 3. Login with default account and password. Username: admin Password: (none) 4. Change the IP with commands listed below: CLI Command: enable configure terminal interface vlan 1 ip address xxx.xxx.xxx.xxx xxx.xxx.xxx.xxx exit LED STATUS INDICATIONS LED Name Indicator /color Condition P1/P2 Alarm On Green Off On Red Off P1/P2 power line has power P1/P2 power line disconnect or does not have supply power Ethernet link fail alarm or power failure alarm occurs No Ethernet link fail and no power failure alarm Copper port Link/Act On Green Ethernet link up but no traffic is detected Flashing Green Ethernet link up and there is traffic detected Off Ethernet link down Copper port On Yellow A 1000Mbps connection is detected Speed Off No link, a 10Mbps or 100 Mbps connection is detected SFP port On Green Ethernet link up Link/Act Off Ethernet link down SFP port On Yellow SFP port speed 1000Mbps connection is detected. Speed Off No link or a SFP port speed 100Mbps connection is detected 8