FLEX I/O EtherNet/IP Adapter Module

Similar documents
ControlLogix Redundant Power Supply Chassis Adapter Module

FlexArmor 24V dc Sinking Input Modules

ArmorBlock MaXum Robot I/O Cable Base and Kempf Box Plate

ControlLogix DC (10-30V) Isolated Output Module

ControlLogix DC ( V) Electronically Fused Output Module

Allen-Bradley PL. ControlLogix Drive Module. Installation Instructions. (Catalog Numbers: 1756-DMD30 and 1756-DMF30)

ControlNet PCI Communication Interface Card

POINT I/O Source Input Module

ArmorBlock MaXum 4 Output Module Series B

ControlLogix Ethernet Communication Interface Module

POINT I/O Protected Output Module

POINT I/O 120/220V ac Output Module

ControlLogix Isolated Analog Voltage/Current Input Module

Installation Instructions

ControlLogix RTD Input Module

FLEX Integra 4 Input Module

ArmorBlock MaXum 8 Input / 8 Output Module Series B

FLEX Integra 2 Input/2 Protected Output Module

POINT I/O 2 Voltage Input Analog Module

ControlLogix Thermocouple Input Module

Barrel Temperature Control Module

XM-124 Standard Dynamic Measurement Module

POINT I/O RTD Input Module

Installation Instructions

ControlLogix DH-485 Communications Module

ControlLogix-XT EtherNet/IP Bridge Module

EtherNet/IP Modules. Installation Instructions

Digital Expansion Terminal Block CompactBlock LDX I/O

Ethernet Network Appliance (with Network Address Translation)

CompactBlock I/O for DeviceNet Modules Series D

ControlLogix DeviceNet Scanner Module

POINT I/O 24V DC 4-channel Discrete Input Module with Diagnostics

MicroLogix 1762-IQ16 DC Input Module

DeviceNet CompactPCI Communication Interface Card

User Manual. XM ControlNet Adapter Catalog Number 1440-ACNR

FLEX I/O 240V AC Digital Input and Output Modules

Stratix 6000 Ethernet Managed Switches

POINT I/O 120V AC Input Module

ControlLogix EtherNet/IP Bridge Module

dc (10 60V) Output Module

CompactLogix EtherNet/IP Web Server Module

POINT I/O 2 Current and 2 Voltage Input Analog Modules

ControlLogix Controller and Memory Board

POINT I/O Synchronous Serial Interface Absolute Encoder Module

MicroLogix 1762-IQ32T DC Input Module

FLEX I/O Digital Input/Output Modules

DeviceNet Analog Base Terminal Block CompactBlock LDX I/O

POINT I/O Output Module

Analog Output Module

AB PLC. CompactBlock Distributed I/O on PROFIBUS DP Series D. Installation Instructions. (Cat. No. 1791P-16B0, -0B16P, -8B8P, -4B4P, -8V8P)

MicroLogix 1762-OB32T Solid State 24V DC Source Output Module

FLEX Ex Spring Clamp Terminal Base

POINT I/O 4 Channel Analog Current Output Module

Installation Instructions

InView Marquee Message Display

FLEX I/O AC Digital Output Modules

POINT I/O 8 Channel High Density Current Input Module

Installation Instructions

POINT I/O 2 and 4 Relay Output Modules

FLEX I/O Digital DC Output Modules

Installation Instructions

1734 POINT I/O Dual Port EtherNet/IP Adapter

POINT I/O Synchronous Serial Interface Absolute Encoder Module

DeviceNet Base RTD and Thermocouple CompactBlock LDX I/O

POINT I/O EtherNet/IP Adapter

PROFIBUS DP Analog, RTD and Thermocouple Base Terminal Block CompactBlock LDX I/O

Ethernet PLC-5 Programmable Controllers

Digital ac/dc (24V) Input Module

POINT I/O 2 Current Output and 2 Voltage Output Analog Modules

CompactLogix 5370 Controllers

Installation Instructions

User Manual. EtherNet/IP and ControlNet to FOUNDATION Fieldbus Linking Devices

Do Not Copy. Important User Information For More Information... 3

1769-L31 CompactLogix Controller

Installation Instructions. FLEX I/O D-Shell Terminal Base Units and Distribution Boards

ControlLogix ControlNet Bridge Module

1719 Ex I/O. Installation Instructions

MicroLogix 1200 Isolated Relay Output Module

POINT I/O 5V DC and 24V DC Very High Speed Counter Module

1769 Compact I/O Communication Bus Expansion Cables

CompactLogix Power Supplies Specifications

XM-440 Master Relay Module

PanelView Plus/VersaView CE Terminals and Display Modules

Compact I/O ASCII Module

ArmorPoint I/O Field Potential Distributor, Series A

Micro800 8-Point Input and 8-Point Output AC Modules

Micro800 Digital Relay Output Plug-in Module

Micro820 Programmable Controllers

Installation Instructions

Micro820 Programmable Controllers

PanelView Component HMI Terminals

Compact 1769-OF4VI Isolated Analog Output Module

Solid-State Output Module

User Guide Firmware Revision SPD02-01RB

Installation Instructions

Compact 1769-OF4CI Isolated Analog Output Module

ControlNet Universal PCI Communication Interface Card

Micro830 and Micro850 Programmable Controllers

PanelView 800 HMI Terminals

1719 Ex I/O. Installation Instructions. Original Instructions

Transcription:

Installation Instructions FLEX I/O EtherNet/IP Adapter Module Catalog Numbers 1794-AENT Use this manual as a guide to install the FLEX I/O EtherNet/IP Adapter Module. Note that this manual covers hardware installation only. Refer to the FLEX I/O EtherNet/IP Adapter Module User Manual, publication number 1794-UM006, for information on configuring the module for use on your network. The following table lists the contents of this manual and where to find specific information. Topic See Page Important User Information 2 European Communities (EC) Directive Compliance 4 EMC Directive 4 Low Voltage Directive 4 Environment and Enclosure 5 Identify Module Components 6 Mounting the Adapter on a DIN Rail Before Installing Modules 7 Mounting (or Replacing) the Adapter on an Existing System 8 Wiring 10 LED Status Indicators 12 Hazardous Location Approval 14 Specifications 15 Mounting Dimensions 16 Ethernet is a trademark of Digital Equipment Corporation, Intel, and Xerox Corporation. FLEX I/O is a trademark of Rockwell Automation

2 FLEX I/O EtherNet/IP Adapter Module Important User Information Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary steps have been taken to assure that each application and use meets all performance and safety requirements, including any applicable laws, regulations, codes and standards. The illustrations, charts, sample programs and layout examples shown in this guide are intended solely for purposes of example. Since there are many variables and requirements associated with any particular installation, Allen-Bradley does not assume responsibility or liability (to include intellectual property liability) for actual use based upon the examples shown in this publication. Allen-Bradley publication SGI-1.1, Safety Guidelines for the Application, Installation and Maintenance of Solid-State Control (available from your local Allen-Bradley office), describes some important differences between solid-state equipment and electromechanical devices that should be taken into consideration when applying products such as those described in this publication. Reproduction of the contents of this copyrighted publication, in whole or part, without written permission of Rockwell Automation, is prohibited.

FLEX I/O EtherNet/IP Adapter Module 3 Throughout this manual we use the following notes to make you aware of safety considerations: WARNING! Identifies information about practices or circumstances that have the potential to create an explosion hazard. ATTENTION! Identifies information about other practices or circumstances that can lead to personal injury or death, property damage or economic loss. Warning and Attention statements help you to: identify a hazard avoid a hazard recognize the consequences We use the following note to call attention to critical information: IMPORTANT Identifies information that is critical for successful application and understanding of the product.

4 FLEX I/O EtherNet/IP Adapter Module European Communities (EC) Directive Compliance If this product has the CE mark it is approved for installation within the European Union and EEA regions. It has been designed and tested to meet the following directives. EMC Directive This product is tested to meet the Council Directive 89/336/EC Electromagnetic Compatibility (EMC) by applying the following standards, in whole or in part, documented in a technical construction file: EN 50081-2 EMC Generic Emission Standard, Part 2 Industrial Environment EN 50082-2 EMC Generic Immunity Standard, Part 2 Industrial Environment This product is intended for use in an industrial environment. Low Voltage Directive This product is tested to meet Council Directive 73/23/EEC Low Voltage, by applying the safety requirements of EN 61131-2 Programmable Controllers, Part 2 - Equipment Requirements and Tests. For specific information required by EN 61131-2, see the appropriate sections in this publication, as well as Allen-Bradley publication 1770-4.1, Industrial Automation Wiring and Grounding Guidelines.

Environment and Enclosure FLEX I/O EtherNet/IP Adapter Module 5 This equipment is intended to operate in a Pollution Degree 2 industrial control environment, in overvoltage category II applications, (as defined in IEC publication 60664-1) at altitudes up to 2000 meters without derating. It must be mounted within a system enclosure, suitably designed for those specific environmental conditions that will be present, and appropriately designed to prevent personal injury resulting from accessibility to live parts. The interior of this enclosure must be accessible only by the use of a tool. Note: See NEMA Standards publication 250 and IEC publication 60529, as applicable, for explanations of the degrees of protection provided by different types of enclosure.

6 FLEX I/O EtherNet/IP Adapter Module Identify Module Components Use the following illustration to identify the external features of the FLEX I/O EtherNet/IP adapter. 1 8 2 3 7 6 4 5 Component Identification 1 EtherNet/IP Adapter Module 2 Indicators 3 MAC ID Label 4 Network cable RJ-45 connector (underside) 5 Module locking tab 6 +24V dc connections 7 24V common connections 8 Flexbus connector

FLEX I/O EtherNet/IP Adapter Module 7 Mounting the Adapter on a DIN Rail Before Installing Modules A B Use the following procedure to mount the adapter on a new system before any I/O modules have been installed. 1. Position the EtherNet/IP adapter module (A) on a 35 x 7.5mm DIN rail (B) (A-B pt. no. 199-DR1; 46277-3; EN 50022) with the bottom rotated outward at a slight angle. 2. Hook the lip on the top rear of the adapter (A) onto the top of the DIN rail (B), and rotate the bottom of the adapter module onto the rail. 3. Press the adapter module down onto the DIN rail until flush. Locking tab (C) will snap into position and lock the adapter module to the DIN rail. 4. If the adapter module does not lock in place, use a screwdriver or similar device to pull the locking tab down while pressing the adapter module flush onto the DIN rail. Then release the locking tab to secure the adapter module in place. If necessary, push up on the locking tab. 5. Connect the adapter wiring as shown under Wiring later in this document. C

8 FLEX I/O EtherNet/IP Adapter Module Mounting (or Replacing) the Adapter on an Existing System Use the following procedure to mount or replace the adapter on an existing system. 1. If present, disconnect the RJ-45 connector from the bottom of the old adapter. 2. Disconnect any wiring jumpered to the adjacent terminal base. 3. Using a screwdriver or similar tool, open the locking tab on the back of the adjacent I/O module and remove the I/O module from its terminal base. 4. Push the flexbus connector toward the right side of the terminal base to unplug the backplane connection. Terminal base of I/O module adjacent to 1794-AENT adapter 31244-M ATTENTION! Make certain that the flexbus connector is completely clear of the adapter. The slide must be completely to the right and the raised spot on the slide visible. 5. Release the locking tab on the back of the old adapter module and remove the old adapter from its terminal base.

FLEX I/O EtherNet/IP Adapter Module 9 6. Before installing the new adapter, note the notch on the right rear of the adapter. This notch accepts the hook on the terminal base of the I/O module mounted next to the adapter. The notch is open at the bottom. The hook and adjacent connection point keep the terminal base and adapter tight together, reducing the possibility of a break in communication over the backplane. 31245-M 7. Complete the adapter mounting as shown below. Push down and in at the same time to lock the adapter on the DIN rail. When the adapter is locked onto the DIN rail, gently push the flexbus connector into the adapter to complete the backplane. C 31244-M 8. If the adapter module does not lock into place, use a screwdriver or similar device to pull locking tab C down while pressing the adapter module flush onto the DIN rail. Then release the locking tab to lock the adapter module in place. If necessary, push up on the locking tab to lock. 9. Reinstall the I/O module onto its terminal base unit.

10 FLEX I/O EtherNet/IP Adapter Module Wiring WARNING! If you connect or disconnect the Ethernet cable with power applied to the adapter or any device on the network, an electrical arc can occur. This could cause an explosion in hazardous location installations. Be sure that power is removed or the area is nonhazardous before proceeding. B D A C E 31246-M 1. Connect the Ethernet network cable to the RJ-45 connector (A) on the underside of the adapter. A 31247-M

FLEX I/O EtherNet/IP Adapter Module 11 IMPORTANT We recommend connecting the module to the network via a 100MB full duplex switch, which will reduce network collisions and lost packets and increase bandwidth. For detailed Ethernet connection information, see the following publications: Ethernet/IP Performance and Application Guide, publication ENET-AP001 Ethernet/IP Media Planning and Installation Guide, publication number ENET-IN001 2. Connect 24V common to the left side of the upper connector, terminal B. IMPORTANT When connecting wiring, torque terminal screws B, C, D, and E to 5-7 inch-pounds. 3. Connect +24V dc input power to the left side of the lower connector, terminal C. 4. Use connectors D and E to pass 24V common (D) and 24V dc power (E) to the next module in the series. IMPORTANT The 1794-AENT requires a minimum load of approximately 100mA (e.g., two FLEX I/O modules) on the Flex rail.

12 FLEX I/O EtherNet/IP Adapter Module LED Status Indicators The faceplate of the 1794-AENT adapter is provided with bi-color LED indicators that display the Module Status, Network Status, and Link Status. Module Status Network Status Link Status The following tables describe the states of the LED status indicators: Module Status State Status Description Off No Power Module does not have 24V DC power. Make sure power is being supplied to the module. Flashing Green Standby Module not configured. Green Operational Module operating correctly. Flashing Red Minor Fault A recoverable fault has been detected. This could be caused by an incorrect or inconsistent configuration. Red Major Fault An unrecoverable fault has been detected. Recycle power to the module. If this does not clear the fault, replace the module. Flashing Red and Green Self Test Module performing power-up self test.

FLEX I/O EtherNet/IP Adapter Module 13 Network Status State Status Description Off Not Powered, No IP Address Module is not powered, or does not have an IP address. Verify there is power and the module is correctly wired to the power supply. Make sure the module is configured Flashing Green No Connections Module has obtained an IP address, but has no established connections. Green CIP Connections Module has an IP address and at least one established connection. Flashing Red Connection Timeout One or more of the connections in which the module is the target has timed out. Red Duplicate IP Address Module has detected that its IP address is already in use. Configure the module with a unique IP address. Flashing Red and Green Self Test Module performing power-up self test. Link Status State Status Description Off No data transmission Module not ready to communicate. Green Ready Module is ready to communicate. Flashing Green Data transmission in progress Module is communicating over the network.

14 FLEX I/O EtherNet/IP Adapter Module Hazardous Location Approval The following information applies when operating this equipment in hazardous locations: Products marked CL I, DIV 2, GP A, B, C, D are suitable for use in Class I Division 2 Groups A, B, C, D, Hazardous Locations and nonhazardous locations only. Each product is supplied with markings on the rating nameplate indicating the hazardous location temperature code. When combining products within a system, the most adverse temperature code (lowest T number) may be used to help determine the overall temperature code of the system. Combinations of equipment in your system are subject to investigation by the local Authority Having Jurisdiction at the time of installation. WARNING! EXPLOSION HAZARD - Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous. Do not disconnect connections to this equipment unless power has been removed or the area is known to be nonhazardous. Secure any external connections that mate to this equipment by using screws, sliding latches, threaded connectors, or other means provided with this product. Substitution of components may impair suitability for Class I, Division 2. If this product contains batteries, they must only be changed in an area known to be nonhazardous. Informations sur l utilisation de cet équipement en environnements dangereux: Les produits marqués CL I, DIV 2, GP A, B, C, D ne conviennent qu à une utilisation en environnements de Classe I Division 2 Groupes A, B, C, D dangereux et non dangereux. Chaque produit est livré avec des marquages sur sa plaque d identification qui indiquent le code de température pour les environnements dangereux. Lorsque plusieurs produits sont combinés dans un système, le code de température le plus défavorable (code de température le plus faible) peut être utilisé pour déterminer le code de température global du système. Les combinaisons d équipements dans le système sont sujettes à inspection par les autorités locales qualifiées au moment de l installation. AVERTISSEMENT! RISQUE D EXPLOSION Couper le courant ou s assurer que l environnement est classé non dangereux avant de débrancher l'équipement. Couper le courant ou s'assurer que l environnement est classé non dangereux avant de débrancher les connecteurs. Fixer tous les connecteurs externes reliés à cet équipement à l'aide de vis, loquets coulissants, connecteurs filetés ou autres moyens fournis avec ce produit. La substitution de composants peut rendre cet équipement inadapté à une utilisation en environnement de Classe 1, Division 2. S assurer que l environnement est classé non dangereux avant de changer les piles.

FLEX I/O EtherNet/IP Adapter Module 15 Specifications I/O Capacity 8 modules Power Supply Note: You must use either a NEC Class 2, a Safety Extra Low Voltage (SELV) or a Protected Extra Low Voltage (PELV) power supply to comply with the CE Low Voltage Directive. A SELV supply cannot exceed 30 Vrms, 42.4 Vpeak or 60 Vdc under normal conditions and under single fault conditions. A PELV supply has the same rating and is connected to protected earth. Input Voltage Rating 24V dc nominal Input Voltage Range 19.2 to 31.2V dc (includes 5% ac ripple) Communication Rate 10/100 Mbps Indicators Module Status - red/grn Network Status - red/grn Link Status - red/grn Flexbus Output Current 640mA maximum @ 5V dc Isolation Voltage 500Vac between user power and Flexbus (test time of 1 minute) Power Consumption 400mA maximum from external 24V supply Power Dissipation 7.3W maximum @ 24.0V dc Thermal Dissipation 24.9 BTU/hr @ 24.0V dc Environmental Conditions: Operational Temperature Storage Temperature Relative Humidity Shock: Operating Non-operating Vibration Ethernet Connector RJ-45 Cat. 5 Power Conductors: Type Wire Size Category Connector Screw Torque Agency Certifications When product is marked 0 to 55 C (32 to 131 F) 40 to 85 C ( 40 to 185 F) 5 to 95% non-conducting 30 g peak acceleration, 11(+1)ms pulse width 50 g peak acceleration, 11(+1)ms pulse width Tested 5 g @ 10 500Hz per IEC 68-2-6 Copper 12 gauge (4mm 2 ) stranded maximum 3/64 inch (1.2mm) insulator maximum 3 (1) 5-7 inch-pounds Listed Industrial Control Equipment for Class I, Division 2, Groups A, B, C, D. Marked for all applicable directives Marked for all applicable acts N223 (1) For information on conductor routing refer to publications 1770-4.1, Industrial Automation Wiring and Grounding Guidelines, and ENET-IN001, EtherNet/IP Media Planning and Installation Manual.

Mounting Dimensions inches (millimeters) B 3.4 (87) 3.2 (80) 2.0 (50) 1.2 (30) 3.7 (94) 1794-AENT 3.4H x 3.7W x 2.7D (87H x 94W x 69D) A A = DIN rail B = Secure DIN rail approximately every 200mm PN 957445-31 2001 Rockwell International Corporation. Printed in USA