Anemometer, Hygrometer Light Meter, Thermometer

Similar documents
4 in 1 Anemometer, Humidity Light Meter, Thermometer

USER`S MANUAL Professional measuring instrument 4 in 1 ATE-9508

Therma-Stor LLC Model LM in-1 Pocket Thermo-Anemometer, Hygrometer, Thermometer & Illuminometer. Instruction Manual.

LIGHT METER. Model : LM-81LX. Digital Measurement Metrology, Inc Digital Measurement Metrology, Inc

LIGHT METER OPERATION MANUAL. Model : LM-81LX

Model LM-81LX. Instruction Manual. Illuminometer. reedinstruments. www. com

9 in 1 Anemometer, Humidity/Temp. meter, Light meter Pt 1000 Temp. ( optional ) Sport/Weather meter ENVIRONMENT METER Model : SP-8001

Model LM-81LX. Instruction Manual. Light Meter. reedinstruments. REED Instruments

Mini Environmental Quality Meter

Mini Environmental Quality Meter

VANE ANEMOMETER HUMIDITY/TEMP.

DIGITAL ANEMOMETER Model : AM-4203

40.00/400.0/4,000/40,000/400,000 Lux LIGHT METER

11 in 1 Environmental Meter

Mini Environmental Quality Meter

VANE ANEMOMETER BAROMETER HUMIDITY/TEMP. Model : ABH-4225

Mini Environmental Quality Meter

LIGHT METER OPERATION MANUAL. auto range 0 to 50,000 Lux, 3 ranges. Model : LX-113S

Air velocity, Air flow, Type K/J thermometer Real time data logger, Data logger no., RS232 ANEMOMETER. Model : DAF2005MDL

ANEMOMETER OPERATION MANUAL. Model : AM-4207SD. SD card real time datalogger + Type K/J thermometer

SD Card real time data recorder + type K/J TEMP. CUP ANEMOMETER

OPERATION MANUAL. auto range + type K Temp. optional Humidity, Light, Anemometer SOUND LEVEL METER Model : SL-4112

ANEMOMETER OPERATION MANUAL. metal vane + air flow. Model : AM-4206M

OPERATION MANUAL. Model : AM Wind speed measurement, pocket type, IP-65 CUP ANEMOMETER

UV LIGHT METER UVC-254

HOT WIRE ANEMOMETER. Model : 204HA

LED LIGHT METER OPERATION MANUAL. Model : LX-1148SD. SD card real time Data Recorder 10 Light Source select, Auto range 0 to 50,000 LUX

TABLE OF CONTENTS 1. FEATURES SPECIFICATIONS General Specifications Electrical Specifications...3

TA 888 Hot Wire Anemometer

Heavy Duty Mini Vane CFM Thermo Anemometer

Humidity + Temp. + Dew Point Pocket size HUMIDITY METER. Model : HT-315

INSTRUCTION MANUAL FOR TQ-8800 TORQUE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Model ST-618. Instruction Manual. Digital Thermo-Anemometer. Digital Measurement Metrology, Inc PRECISION IS OUR VISION

Anemometer SD Card Datalogger. Instruction Manual

User's Guide. Hot Wire Thermo-Anemometer. Model

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

Light Meter with Bar Graph

User's Manual. VA893 Thermo Anemometer

UVA LIGHT METER OPERATION MANUAL. Model : UVA-365SD. SD card real time datalogger + Type K/J thermometer

3 in 1, Type K/J, Pt 100 ohm, Infrared Thermometer Real time data logger, Data logger no., RS232 THERMOMETER.

CFM/CMM Hot-Wire Thermoanemometer

OPERATION MANUAL. UVA and UVB measurement UV LIGHT METER. Model : YK-35UV

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model

Hygro Thermo-Anemometer Model

12 channels TEMPERATURE RECORDER Model : BTM-4208SD

ST Model. Instruction Manual. Multi-Function Environment Meter. reedinstruments. www. com

The Specification of Hot Wire Anemometer Manual PCE-423

Torque Meter. Instruction Manual

AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

OPERATION MANUAL. UVA and UVB measurement UV LIGHT METER. Model : YK-35UV

MOISTURE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION. 3, Hagavish st. Israel Tel: , Fax:

OPERATION MANUAL. Carbon monoxide 0 to 1000 PPM, Temp. CO METER. Model : GCO-2008

User's Guide. Hot Wire Thermo-Anemometer Model Introduction

VIBRATION METER Model : VB-8213

PRESSURE METER OPERATION MANUAL. Model : PS-9302

Heavy Duty Hot Wire CFM Thermo-Anemometer

AC/DC MAGNETIC METER OPERATION MANUAL. Model : PCE-MFM G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

User's Guide. Hot Wire Thermo-Anemometer Model

MANOMETER OPERATION MANUAL mbar, differential input. Model : PM-9107

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

CONDUCTIVITY METER OPERATION MANUAL. Model : CD-4322

MANOMETER OPERATION MANUAL. 200 mbar, differential input. Model : PM-9102

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

VACUUM METER Model : VC-9200

Heavy Duty Pitot Tube Anemometer and Differential Pressure Manometer

User's Guide. Cup Thermo-Anemometer. Model AN400

Heavy Duty CFM Thermo-Anemometer Model

Visible Light SD Card Datalogger

Light Meter (Foot Candles)

User's Guide. Vane Thermo-Anemometer Datalogger. Model Introduction

OPERATION MANUAL. SD card real time datalogger 3 Channels TEMPERATURE DATA RECORDER. Model : MTM-380SD. Your purchase of this 3

VB Model. Instruction Manual. Vibration Meter. reedinstruments. www. com

ENVIRONMENT METER WITH DATALOGGING SD CARD

USER MANUAL. Light Meter. Model LT510. Additional User Manual Translations available at

CODUCTIVITY METER OPERATION MANUAL. Model : CD-4303

INSTRUCTION MANUAL. Models: H100 Light Meter

Large Vane CFM/CMM Anemometer / Psychrometer

DISSOLVED OXYGEN METER Model : YK-22DO. * 0 to 20.0 mg/l, 0 to 50.0 o C, o C/ o F. * Automatic temperature compensation.

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

Large Vane CFM/CMM Thermo-Anemometer

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

OPERATION MANUAL. Pen type, air oxygen and Temp. O2 METER. Model : PO2-250

OPERATION MANUAL. SD card real time datalogger, RS232/USB VIBRATION METER. Model : VB-8206SD

User Manual. Data Logging Anemometer. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT

DIGITAL MULTIMETER 4 1/2 digits, True RMS Model : DM-9027T

Torque Meter. Instruction Manual

AC/DC MAGNETIC METER

Datalogging Hot Wire CFM Anemometer

SOIL MOISTURE METER OPERATION MANUAL. Model : DSMM500. Your purchase of this

TU-2016 TURBIDITY METER

Manual Anemometer PCE-423

Light Meter SD Card real-time datalogger

Laser, PHOTO TACHOMETER RS

Manual Digital Thermometer PCE-T 390

TORQUE WRENCH OPERATION MANUAL. Model : TQ Kgf-cm, heavy duty, professional

User's Manual. CFM/CMM Thermo Anemometer + InfraRed Thermometer. Model AN200 UNITS NEXT AREA RECALL. cf m/cmm Anemometer Thermometer AN200

MMD7003 USER S MANUAL. DIGITAL and LED PRECISION MOISTURE METER

OPERATION MANUAL. SD card real time datalogger, RS232/USB PRESSURE METER. Model : PS-9303SD. Your purchase of this PRESSURE METER with

DISSOLVED OXYGEN METER Model : YK-22DO. * 0 to 20.0 mg/l, 0 to 50.0 o C, o C/ o F. * Automatic temperature compensation.

OPERATION MANUAL. SD card real time data Recorder, USB/RS232 SOUND LEVEL METER. Model : SL-4023SD. Your purchase of this

Transcription:

Anemometer, Hygrometer Light Meter, Thermometer

TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 2 3. FRONT PANEL DESCRIPTION... 4 3-1 Power Button... 4 3-2 Hold Button... 4 3-3 Max. / Min. Button... 4 3-4 Unit / Zero Button... 4 3-5 /, Lux/Ft-cd button... 4 3-6 Function Button... 4 3-7 Air Flow Sensor... 4 3-8 Thermocouple Input Socket... 4 3-9 R.H. Sensor... 4 3-10 Light Sensor... 4 3-11 LCD display... 4 3-12 Battery Compartment / Cover... 4 3-13 Wristlet... 4 4. MEASURING PROCEDURES... 5 4-1 AIR VELOCITY EASUREMENT... 5 4-2 TEMPERATURE MEASUREMENT (Thermocouple)... 5 4-3 RELATIVE HUMIDITY MEASUREMENT... 6 4-4 LIGHT MEASUREMENT... 6 5. OTHER FUNCTIONS... 7 6. BATTERY REPLACEMENT... 8 7. OPTIONAL THERMOCOUPLE PROBE AND OTHER ACCESSORIES... 9

1. FEATURES * 4 in 1 professional measuring instrument: Anemometer, Hygrometer, Thermometer, and Light meter. * Tiny bone shape with lightweight and small size case design are suitable for handling with one hand. * Wristlet design provides extra protection to the instrument especially for user one hand operation. * Low-friction ball bearing mounted wheel design provides high accuracy at high and low air velocity. * Exclusive photo diode and color correction filter light sensor, spectrum meets C.I.E. photopic. * High precision thin-film capacitance humidity sensor with fast response to the humidity changes. * Standard type K (NiCr-NiAl) thermocouple input jack suitable for all kinds of type K probe. * Built- in microprocessor circuit assures excellent performance and accuracy. * Concise and compact buttons arrangement, easy operation. * Memorize the maximum and minimum value with recall. * / selectable by pressing button on the front panel. * Lux/Feet-candle selectable by pressing button on the front panel. * Air velocity measuring units selectable by pressing button on the front panel for five kinds of units. * Multi channel display for relative humidity and temperature measured values or air velocity and temperature measured values at the same time. * Zero button design makes light meter calibration. * Hold function to freeze the current reading value. 1

2. SPECIFICATIONS 2-1 General Specifications Display 8 mm LCD display Measurement Anemometer, Humidity, Temperature. Light Operating Max. 80% RH. Humidity Operating 0 to 50 C (32 to 122 F) Temperature Over Input Indication of "- - - - " Display Power Supply 006P DC 9V battery (Heavy duty type) Power Approx. DC 6.2 ma Consumption Weight 160g (battery included) Dimension HWD 156x60x33 mm (6.14x2.36x1.29 inch). Standard Instruction Manual Accessory Optional Carrying case. Accessories Temperature probe ( Please refer to page 9 ). 2-2 Electrical Specification ( 23 ± 5 ) Measurement Range Resolution Air velocity ft/min 80 to 5910 ft/min 1 ft/min m/s 0.4 to 30.0 m/s 0.1 m/s km/h 1.4 to 108.0 km/h 0.1 km/h MPH 0.9 to 67.0 mile/h 0.1 MPH knots 0.8 to 58.3 knots 0.1 knots Temperature 32 to 122 0.1 ( thermister) 0 to 50 0.1 2

Measurement Range Resolution Humidity % RH 10 to 95 %RH 0.1 %RH Temperature 32 to 122 0.1 ( thermister) 0 to 50 0.1 Light Lux 0 to 2,200 Lux 1 Lux 1,800 to 20,000 Lux 10 Lux * auto range Ft-cd 0 to 204.0 Fc 0.1 Ft-cd 170 to 2,000 Fc 1 Ft-cd Temperature ( Type K ) -148 to 2372 0.1-100 to 1300 0.1 Measurement Range Accureacy Air velocity 80 to 5910 ft/min 0.4 to 30.0 m/s 20 m/s : ± 3% F.S. 1.4 to 108.0 km/h > 20 m/s : ± 4% F.S. 0.9 to 67.0 mile/h 0.8 to 58.3 knots 32 to 122 ± 2.5 0 to 50 ± 1.2 Humidity 10 to 95 %RH < 70% RH : ± 4 %RH 70% RH : : ± ( 4%rdg + 1.2 %RH ) 32 to 122 ± 2.5 0 to 50 ± 1.2 Light 0 to 20,000 Lux ± 5% rdg ± 8 dgt 0 to 2,000 Fc Temperature -148 to 2372 ± (1% rdg + 2 ) ( Type K ) -100 to 1300 ± (1% rdg + 1 ) Remark : ft/min : feet per minute m/s : meters per second km/h : kilometers per hour MPH : miles per hour knots : nautical miles per hour Ft-cd : feet candle 3

3. FRONT PANEL DESCRIPTION Fig. 1 3-1 Power Button 3-7 Air Flow Sensor 3-2 Hold Button 3-8 Thermocouple Input Socket 3-3 Max. / Min. Button 3-9 R.H. Sensor 3-4 Unit / Zero Button 3-10 Light Sensor 3-5 / Button 3-11 LCD display Lux/Ft-cd Button 3-12 Battery Compartment / Cover 3-6 Function Button 3-13 Wristlet 4

4. MEASURING PROCEDURE 4-1 Air Velocity Measurement 1) Power on the instrument by pressing the " Power Button " ( 3-1, Fig. 1 ). 2) Select the Anemometer function by pressing " Function Button " ( 3-6, Fig. 1 ). 3) Press the " Unit/Zero Button " ( 3-4, Fig. 1 ) to select unit that you want and then face the " Air Flow Sensor " ( 3-7, Fig. 1 ) to the source of wind. 4) Allow time for the reading to become stable and note the value indicated. From a practical point of view the velocity may fluctuate. 4-2 Temperature Measurement ( Thermocouple ) 1) Power on the instrument by pressing the " Power Button " ( 3-1, Fig. 1 ).. 2) Plug a type K thermocouple probe in the " Thermocouple Input Socket " ( 3-8, Fig. 1 ). 3) Select the Temperature function by pressing " Function Button " ( 3-6, Fig. 1 ) 4) Contact the Thermocouple Sensor Head with measuring object and the reading value will be displayed on the LCD display. Measuring Consideration of Temperature Measurement ( Thermocouple ) * Please make sure the polarity is correct when you plug a thermocouple probe in the Temp. input socket. 5

* The temperature difference between thermocouple probe and thermometer will cause an inaccurate measuring result. Therefore, for the best measuring and accuracy performance, whenever change a probe or plug a new probe, thermal equivalent between probe plug and meter's input socket is a necessary condition. Thermal equivalent procedure may take few minutes and apply only when the probe has been exposed to an ambient temperature different from the meter. 4-3 Humidity & Ambient Temperature Measurement 1) Power on the instrument by pressing the " Power Button " (3-1, Fig. 1). 2) Select the Relative Humidity function by pressing "Function Button " ( 3-6, Fig. 1 ). 3) At the mean time the reading value of relative humidity and temperature will be displayed on the LCD display. 4) When the meter is applied in a new environment, a few minutes are required to reach a stable condition. 4-4 Light Measurement 1) Power on the instrument by pressing the " Power Button " ( 3-1, Fig. 1 ). 2) Select the Light Measurement function by pressing the " Function Button " ( 3-6, Fig. 1 ) until the light value is displayed. The light display digits are oriented 180 from the other function displays for easy exposure and output reading of the light sensor. 3) Press the " Lux/Ft-cd Button " ( 3-5, Fig. 1 ) to select measuring unit " Lux " or " Ft-cd ". 6

Zero Offset Adjustment of Light Function : * For best results zero the light sensor prior to use in a dark environment. Placing the light sensor end of the meter under a desktop or flat surface so as to block any light can accomplish this. Then press the "Unit/Zero Button" ( 3-4, fig. 1 ) to set the meter indication to zero. * Zero point can drift due to environment temperature and battery power change as well as for other reasons. It is recommended that the zero be checked frequently using the above procedure. 5. OTHER FUNCTIONS 5-1 Hold Function Whenever press the "Hold Button (3-2, Fig. 1)" will freeze the current reading value with a "HOLD" symbol on the display. 5-2 Data Record Function 1) The Data Record function records & displays the maximum and minimum reading values. Start the Data Record function by pressing the " Max./Min. Button " ( 3-3, Fig. 1 ) once. There will be a " REC " symbol on the display. 7

2) With the REC symbol on the display : (a) Press the " Max./Min. Button " ( 3-3, Fig. 1 ) once and the " Max " symbol along with the maximum value will appear on the display. (b) Press the " Max./Min. Button " again, the " Min " symbol along with the minimum value will appear on the display. (c) To exit the memory record function, press the " Max./Min. Button " continuously for at least 2 seconds. The display will revert to the current reading. (d) Clear the Max./Min. value recorded by pressing the " Hold Button " ( 3-2, Fig. 1 ) once. Previous recorded Max./Min. value will be given up and then revert to the REC. function keep on recording. 5-3 Auto Power Off Disable In order to prolong the battery life, the instrument has "Auto Power Off " function. The meter will switch off automatically if no buttons are pressed for around 10 minutes. 6. BATTERY REPLACEMENT 1) When the LCD display shows " " symbol, it is necessary to replace the battery. However measurement may still be made for several hours after the low battery indicator appears. 2) Open the " Battery Compartment / Cover " ( 3-12, Fig. 1) and remove the battery. 3) Install a 9V battery (Alkaline or Heavy duty type) and then reinstate the cover. 8

7. OPTIONAL TEMPERATURE PROBE AND OTHER ACCESSORIES Thermocouple Probe (Type K) TP-01 * Measuring Range : -40 to 250 ( -40 to 482 ) * Max. short-term operating temperature: * It's an ultra fast response naked-bead thermocouple suitable for many general Thermocouple Probe purpose application. (Type K) TP-02A * Measuring Range : -50 to 900 ( -50 to 1650 ) Thermocouple Probe * Dimension: 10cm tube, 3.2 mm Dia. (Type K) TP-03 * Measuring Range : -50 to 1200 ( -50 to 2200 ) Thermocouple Probe * Dimension: 10cm tube, 8 mm Dia. (Type K) TP-04 * Measuring Range : -50 to 400 * surface Temp. ( -50 to 752 ) probe. * Size : Temp. sensing head - 15 mm Dia. Carrying case Probe length - 12 mm. CA-52A * High quality carrying case with sash. 9 0306-DLAF8000