PROFIBUS Technology Products

Similar documents
Technology PROFIBUS Technology Chips - Modules - Development Kits

PROFIBUS slave development

SIMATIC PROFIBUS Interface Components

SIMATIC NET IM 184 PROFIBUS Interface Module

PROFIBUS Workshop EN B U I L D I N G P R O C E S S M A N U F A C T U R I N G EUROPEAN FIELDBUS STANDARD. Chapter 1 Date 11/04/99, page 1

PA ROUTERS. The following criteria can be applied when choosing the network transition:

Supply voltage. Input current. Power loss. Memory. Battery. CPU processing times

General information. Supply voltage. Input current

DF PROFI II PC/104-Plus

Product type designation. General information. Supply voltage. Input current. Power loss

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

SIMATIC NET. S7-CPs for PROFIBUS. CP Extended for PROFIBUS. Manual Part B4

CPU 412H. Function. Parameterizable properties

Fig. 1: Industrial Network Hierarchy

Max Felser. PROFIBUS Manual. mmww. swwmt. A collection of information explaining. PROFIBUS networks

General information. Supply voltage

DF PROFI II PCIe. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II PCIe KUNBUS

DF PROFI II CPCI. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II CPCI KUNBUS

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

SIMATIC S7-400, CPU KB WORKING MEMORY (384 KB CODE, 384 KB DATA) 1. INTERFACE MPI/DP 12 MBIT/S 2.IF PROFIBUS DP, 3.

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

CPU 317F-2 DP. Page 1603 Mar 2008 Siemens ITS

Profibus DP slave. dual ported RAM 2Kbyte. Maximum length for I/O data. Maximum length for output data. Status display

Programming package STEP 7 V5.2 SP1 or higher with HSP 0126

SIMATIC NET SPC4 Siemens PROFIBUS Controller

Product type designation. General information. Supply voltage

PROFIBUS and Integrated Safety architectures in Ex areas

Intelligent Solutions for PCs CAN and PROFIBUS. Communication with PCs and PC/104

CAN 300 PRO, Communication Module

64 kbyte ; 64 KB / 21K instructions RAM (integrated) Yes ; 4 KB: bit memory, counter, times and data

CPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS

Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21.

Type IBS EVA BASIC IBS EVA ADDITION 1 IBS EVA ADDITION 2 IBS SIG PART 2 UM IBS SIG PART 2 UM E. length: 50 mm acc. to RS x 9-pin D-SUB

Product type designation. General information. Supply voltage. Input current. Power losses

IE/PB LINK PN IO. PROFINET applications

Data sheet CC 03, Commander Compact (603-1CC21)

SIMATIC. ET 200S IM CPU Interface Module. Introduction. New features 2. Technical specifications 3. Product Information 06/2007 A5E

STATUS COM FAIL CONFIGURATION ERROR READY RUN BUS HMS FIELDBUS SYSTEMS AB PILEFELTSGATAN SE HALMSTAD, SWEDEN

General information. Supply voltage. Input current

Serial communication with PCs. Multi-COM. The intelligent 6-channel serial PC board

Product type designation. General information. Supply voltage. Input current

100 ms. 30 µs; Time per I/O byte. 24 V DC No; Power supply via system power supply. Not relevant for 400 series (300 series set)

SBPC-21-PB FifeNet to Profibus Gateway

PAS 300, PROFIBUS Slave Interface Module

General information. Supply voltage. Input current

General information. Supply voltage. Input current

Product type designation. General information. CiR - Configuration in RUN. Input current. Power loss. Memory

CPU. Switch 1 Switch 2

General information. Configuration control. Display. Control elements. Supply voltage

General information. Supply voltage. Input current

PK2200 Series. Features. C-Programmable Controller. Specifications Board Size Enclosure Size Operating Temp.

DREHMO i - matic Electrical actuator with integral controls

SIPLUS CPU 313C-2DP. Function

ANTAL ELECTRONIC Field Bus and Communication Technology. Manual PDP2CL2. Version 3.08

Supply voltage. Input current. Encoder supply. Memory

General information. Display. Control elements. Supply voltage

Connect AS-I Gateways to PC for Configuration and Troubleshooting

Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:

Freelance 800F AC 800F

Introduction to Fieldbus and DeviceNetworks

Accessories. Embedded Control. Order number: Flash-RAM memory module, 128 K x 16 (for 680I) Accessories

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Product Description. Altus S. A. 1

Documentation for BK3xx0 and LC3100 Bus Couplers for PROFIBUS-DP

Bolt 18F2550 System Hardware Manual

6ES7151-8AB01-0AB0. 5/18/2011 Siemens Industry IA/DT/BT Service&S. siemens.com/ww/llisapi.dll?func=csl 1/10 ET200S, IM151-8 PN/DP CPU, 192 KB

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

Ponto Series CPUs. Product Description. Ordering Information

PACSystems* RX3i IC695PBM300

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

S7-400, M7-400 Programmable Controllers

Serial PROFIBUS Interface

Device manual Field modules DP AC2630 / AC2631 / AC2634 AC2636 / AC2637 / AC / / 2013

VersaMax IP Input Module

Integrate the Fieldbus into your device without much development effort involved! All-in-one single bus node for:

T1K MODBUS Base Controller Specifications

General information. Configuration control. Display. Control elements. Supply voltage

IM IM in the RS485 variants features: 9-pin Sub-D socket for connection to PROFIBUS DP

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

S800 I/O ABB Automation

User Manual. KE-Relay or KD-Relay Profibus DPV0 Communication Module. Page 1 / 18. KE-PROFI-DP0 Version (NE_NC-KE-PROFI-DP0_MAN_01_10_FN04)

Data sheet VIPA CPU 115DP (115-6BL22)

Distributed Control I/O System ADAM-8000 Series

PNO Test Report Slave on PROFIBUS DP

Product type designation

Documentation BX3100. Bus Terminal Controller for PROFIBUS-DP. Version: Date:

digiclip Data sheet DF31DP Special features B en

General information. Display. Control elements. Supply voltage

General information. Configuration control. Control elements. Supply voltage. Input current. Power. Power loss. Memory

EASY219 / IEC CANopen Master / Slave

MGate 4101-MB-PBS Series

Data sheet CPU 315SB/DPM (315-2AG12)

PKV 30-DPS. Protocol converter for PROFIBUS-DP slave. Device manual

General information. Display. Supply voltage. Input current

New Features New Features Date 06/10/00, Page 1

Fieldbus slave modules w/o I/Os

AC 800M for Compact Product Suite Outline of all modules

HIGH SPEED COUPLER PROFIBUS DP/PA

MOVITRAC 31.. Frequency Inverter

VPGate Manual PROFIBUS to serial

Transcription:

PROFIBUS Technology Products ASICs Interface modules Development packages Date 11/04/99, page 1

PROFIBUS concept ASPC2 PROFIBUS DP/FMS RS 485, FIBER OPTIC SPC4 SPC3 SPC3 Repeater/ OLM SPC3 LSPM2 Date 11/04/99, page 2

PROFIBUS ASICs Master ASPC2 Intelligent Slave SPC3 12 MBaud RS 485 DPC31 SPC41 + SIM 11 31.25 kbaud IEC 1158-2 Simple Slave LSPM2 SPM2 Date 11/04/99, page 3

Single Chips LSPM2 SPM2 MQFB, 80 Pin, 2cm 2 PQFB, 120 Pin, 10cm 2 Maximum Transmission Rate 12 MBaud Complete Processing of DP Protocol No processor required Data Volume: LSPM 2: 32 Bit I/O, 8 Bit Diagnosis SPM 2: 64 Bit I/O, 16 Bit Diagnosis Date 11/04/99, page 4

LSPM2 schematic Complete DP Slave block Clock Ge nerator Transm itter Receiver MS_ Port A TXD RXD I/O Shift / EEPROM re gis te r In te rfa c e ALU Port B I/O Parameter Assignment Inputs Port C Port D I/O / D ia g n osis I/O/ Diagnosis Port E Diagnosis W a tc h - dog 4x8-Bit-Ports available Date 11/04/99, page 5

Function L-/SPM2 Watchdog Timer integrated Automatic baudrate generator EEPROM interface for station address, Ident number Shift register interface I / O Interface Parameterization ports Diagnostic data is specified LSPM2/ SPM2 supports all mandatory and optional services for slave solutions Date 11/04/99, page 6

intelligent ASICs PROFIB. DP ASPC2 Application Master Layer 2 PROFIBUS FMS PROFIBUS Part 1 SPC 3 SPC 41 Application Application Slave Slave PROFIBUS DP PROFIBUS Part 1 PROFIB. DP PROFIBUS FMS PROFIBUS Part 1 + Data-Link-Layer IS + Physical-Layer Synchronous DPC 31 Application Slave DPV1 PROFIBUS DP PROFIBUS Part 1 + Data-Link-Layer IS + Physical-Layer Synchronous PROFIBUS RS 485 (max. 12MBaud) Hardware SIM 11 SIM 11 Software PROFIBUS (intrinsic safety) IEC 1158-2 (31.25 KBaud) Date 11/04/99, page 7

intelligent ASICs SPC3 SPC41 DPC31 ASPC2 Max. Transmission 12 12 12 12 Rate [Mbaud] Transm. Medium RS 485 RS485 / IEC 1158-2 (with SIM 11) RS 485 Protocol DP (DPV1) DP/FMS/PA DP/DPV1 DP/DPV1/FMS Message Buffer 1.5 1.5 6 1,000 [kbyte] external Housing PQFP, 44 Pin PQFP, 44 Pin PQFP, 100 Pin MQFP, 100 Pin Date 11/04/99, page 8

SPC3 ASIC up to 244 byte of data automatic search of baudrate 9.6kBd-12MBd 3 buffers for each: input & output data; 1 for PRM; 2 for CFG & DIAG firmware available SPC3 1.5 kbyte internal RAM DP slave protocol integrated interface to: Intel (8032, 80x86) Motorola (HC11/16/916) Siemens (80166/80167) Date 11/04/99, page 9

DPC31 ASIC up to 244 byte of data automatic search of baudrate 9.6kBd-12MBd 3 buffers for each: input & output data; 2 for PRM, CFG & DIAG firmware available DPC31 DP slave protocol integrated interface to: Intel (8032, 80x86) Motorola (HC11/16/916) Siemens (C166) Date 11/04/99, page 10

DPC31 ASIC integrated 8031 core 100 pin PQFP housing 31.25kBd synchronous firmware includes complete DPV1 synchronous serial interface up to 40 bits I/O standard interface for memory expansion 6 kbyte internal RAM Date 11/04/99, page 11

SPC41 ASIC Maximum Transmission Rate 12 MBaud Large data volumes (up to 244 Byte) Fast, since time critical functions reside in hardware Integrated part of DP functions FMS support and PA support Simultaneously Slave to ISP 3.0 (Now Part IV of PROFIBUS) 10 mw power loss (when used over IEC H1) 8 bit fixed parallel interface SPC41 Date 11/04/99, page 12

SPC41 ASIC PROFIBUS Part 4, IEC 1158-2 PROFIBUS Part 1, RS 485 SPC41 SIM11 Devices Software µp Server Software Sensor Actuator Field Device Date 11/04/99, page 13

SPC41 ASIC Free FDL access is supported by (used for DP-V1): 5 System Management Service Access Points (SAPs) Default- SAP 64 SAPs (structure specified) Supported PROFIBUS DP services realized in HW : Data-Exchange Read-Input-Data Read-Output- Data Global-Control (Sync,Freeze, Clear-Data) Diagnosis, parameter assignment, configuration is realized through the FLC -Software (Server Software) Date 11/04/99, page 14

DPC31/SPC41 - use for PA The communication block SIM 11 is intended for use in fail-safe fieldbus systems with 31.25 kbit/s and there supplies the functions of a medium attachment unit for IEC H1 (identical PROFIBUS-PA) according to IEC 1158-2 Except for the SIM 11, only few external components are needed to connect modules or field devices to a fail-safe network for PROFIBUS-PA according to the PNO Guideline Date 11/04/99, page 15

SPC41 - PA TxS TxE Transistor to Sensor and. Actuator SPC 4 Reset SIM 1 Diode Bridge RxS Resistor M M 3.3 V 5 V SIM 11 in Constant Current Mode with SPC 41 without isolation Date 11/04/99, page 16

Software ASPC2 + Master SW Protocol DP for 80165 (80 kbyte) SPC3 + Slave SW Protocol DP (6 kbyte) DPC31 Slave SW Protocol DP/DPV1 + (depends on implementation) SPC41 + Slave SW Protocol DP, FMS,PA (30 kbyte) Date 11/04/99, page 17

Modules Make the fastest PROFIBUS implementation possible Requires no SMD technology by the device manufacturer Reduces development effort Low cost solution for getting started, and low volume units PROFIBUS part is already complete Proven technique Date 11/04/99, page 18

Modules IM 184 Simple Slave module IM 183-1 Intelligent Slave module SPC3 IM 180 Master module ASPC2 IM 181 Carrier board for ISA LSPM2 Common features: 5V DC power supply 0 to 70 C permissible ambient temperature Transmission rate 12 Mbaud maximum Date 11/04/99, page 19

IM 184 PROFIBUS protocol handling by LSPM 2 ASIC 32 configurable inputs/outputs 8 separate diagnostics inputs connection: 2x34-pin connectors for connection to host network 10-pin connector for RS-485 floating RS-485 interface for PROFIBUS-DP power consumption typ. 100 ma dimensions (W x H): 85 x 64 mm / 3.3 x 2.5 in (modular design) Date 11/04/99, page 20

IM 183 PROFIBUS protocol handling by SPC 3 ASIC CPU 80C32 microprocessor 20 MHz clock frequency 32 Kbytes SRAM user memory 32 kbytes (mirrored) or 64 kbyte EPROM the host interface is the address and data bus on the interface module 50-pin connector for connection to host network 14-pin connector for RS-232 10-pin connector for RS-485 dimensions (W x H): 86 x 76 mm / 3.3 x 2.7 in Date 11/04/99, page 21

IM 180 PROFIBUS protocol handling by ASPC 2 ASIC 80C165 microprocessor 40 MHz clock frequency 2 x 128K x 8-bit RAM user memory 128K x 16-bit flash EPROM program and parameter memory 48 MHz oscillator chip for ASPC 2 16/8-bit data bus can be connected; dual-port RAM (8K x 16 bit); 64-pin connector (4 rows); optional 8/16-bit data bus connectable high integrity data exchange via dual-port RAM dimensions (W x H): 100 x 100 mm Date 11/04/99, page 22

Development Package What is a development package? Complete package with Slaves and Master and Software Only prerequisite for setup is a PC-AT Easy start for newcomers Easy to understand (Plug and Play) Included test software can be used for each Slave Information about the handling with EN 50170 Date 11/04/99, page 23

Development Package 4 IM 183-1 Int. Slave module IM 180 Master module ASPC2 IM 181 Carrier board for ISA Consists of IM 184 Simple Slave module LSPM2 + SW Suitable for master- and slave developments in 12 Mbaud technology Permits setting up, configuring, running diagnostics of a complete PROFIBUS-DP network Includes examples for user diagnostic and parameterization Handling of sync and freeze mode SPC3 Date 11/04/99, page 24

Services ASICs, DP-Modules, DP-Slave Software for SPC 3/ DPC 31 and Development Package 4 can be ordered normally DP/FMS/PA-Slave SW for SPC 4 is offered by ITEC Master SW for ASPC2 available with license agreement (object code) $19,500 Master SW (DP) Support via phone and PROFIBUS seminars at the are free of charge Date 11/04/99, page 25

ASIC prices List price for ASICs Type list price per ASIC, US$ list price per ASIC, US$ LSPM2 20.58 (40 pcs.) 13.60 (9,900 pcs.) SPM2 22.67 (24 pcs.) 19.34 (10,000 pcs.) SPC3 17.93 (96 pcs.) 10.01 (9,792 pcs.) DPC31 18.00 (60 pcs.) 10.29 (10,200 pcs.) SPC41 15.59 (96 pcs.) 13.72 (960 pcs.) SIM11 15.13 (160 pcs.) 11.74 (960 pcs.) ASPC2 32.42 (66 pcs.) 25.27 (9,900 pcs.) DP Slave-SW for SPC3 US$1,575.00 DP Slave-SW for DPC31 US$2,800.00 Date 11/04/99, page 26

Module prices List price for modules, simple PC-boards and Development Package 4 for PROFIBUS-DP Type List price, $ IM 180 (Master module) 750 IM 181(Carrier board for ISA) 270 IM 183-1 (Intelligent Slave 260 module) IM 184 (Simple Slave module) 230 Development Package 4 3,000 Date 11/04/99, page 27