NPN/PNP DISCRETE HIGH SPEED INPUT & NPN TRANSISTOR OUTPUT MODULE

Similar documents
NPN / PNP DISCRETE INPUT & NPN TRANSISTOR OUTPUT MODULE, 16 points each

BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection)

R7D-RR8 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, 8 points MODEL. (DeviceNet)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

MODEL: R2K-1 SEN TRONIC AG. R2K Series

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

R6-NC1 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL CC-Link INTERFACE MODULE MODEL. (CC-Link Ver.1.10; for 16-point analog signals)

PWR. Power Module Slots

DLS-E2 TELEMETERING UNIT BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (16 contact inputs & 16 open collector outputs)

R3-GE1 BEFORE USE... INSTALLATION POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP)

R6-NE1 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP, for 32-point analog signals)

R3-NL1 LONWORKS INTERFACE MODULE BEFORE USE... INSTALLATION POINTS OF CAUTION INSTRUCTION MANUAL. R3-nL1 MODEL

NETC01-M2. Network converter USER MANUAL. MECHATROLINK-Ⅱ compatible HM

MODEL: GR8-EM. Communication Adaptor GR8 Series

YASKAWA AC Drive-V1000 Option MECHATROLINK-III. Technical Manual

R3-NL2 INSTALLATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL LONWORKS INTERFACE MODULE MODEL. (I/O 56 points)

INSTRUCTION MANUAL 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

CONTENTS 1. BEFORE USE GENERAL DESCRIPTION POINTS OF CAUTION HARDWARE SPECIFICATIONS... 4

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

R1M-J3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL RTD & POTENTIOMETER INPUT MODULE MODEL. (8 points)

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White.

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Technical Manual. YASKAWA AC Drive-Option Card MECHATROLINK-II. Type: SI-T3

Plug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

Industrial Sensor Networking Technology for Improvement of Manufacturing Equipment Efficiency

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

Terminal block 2 A 5 X 3. Specification

Hints for Replacement of Obsolete Controller Models BY240 with New Models BY340

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

V E2B Snap-in I/O Module

Safety Mats & Area Guarding

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

MODEL: R1M-GH. PC Recorders R1M Series

KTA-250 Anemometer Alarm Card

Brushless DC Motor Driver CBM-105 FN/FP User Manual

RAD-DAIO6-IFS. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs. INTERFACE Data sheet.

USER S MANUAL. FX2N-64DNET DeviceNet Interface Block

MODEL: WL40EW2F. Wireless I/O WL40F Series

V E1B Snap-in I/O Module

EtherCAT Remote I/O Terminal GX series

Vision OPLC V TR6/V350-J-TR6

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Specifications N Termination Voltage Range Current Consumption, Max. Type Number Termination. Voltage Range. Sinking Sensor Current

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.

Programless Controller (With Stroke Study) How to Order

KCD-HP. KCD-HP200x, 300X. [Figures] Top : 1% Sensor probe Bottom left : 10% / 20% Sensor probe Bottom right : Holding bracket(optional) Measurement

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

Voltage Current Front-mounting bracket

MODEL: DL8. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.) Web Data Logger DL8

USER S MANUAL High-Speed High-Accuracy Eddy Current Digital Displacement Sensor. GP-X Series

KNX is a European Standard Protocol used for household and industrial Buliding Management System (BMS).

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes Yes Yes* USB device, mini-b Com Ports, separate order, user-installed

MODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

Instruction Manual. ICENI/MA-01 MODBUS Master Module. Pub_ Issue 1

Cat. No. W13E-EN-01. SmartSlice GRT1-Series. GRT1-PNT PROFINET IO Communication Unit OPERATION MANUAL

VIBRATION MONITOR CX-RLY

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

EXD-TEVI Economizer Controller for Tandem Compressors

Monitoring Relays can be used to monitor 3-phase power supplies with 3 or 4 wires simply by changing DIP switch settings.

SRT2-ROC08, SRT2-ROC16

WEB-ENABLED REMOTE TERMINAL UNIT Model: DL8 USERS MANUAL

FL MC 2000E (SM40) LC

INSTALLATION MANUAL For authorized service personnel only.

MODEL: M2EXM. Super-mini Signal Conditioners with Display Mini-M M2E Series

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

MODEL: M1EXM. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

SYSMAC Remote Transistor Module

CBM-103FN/FP Circuit Board

Solid-state Timer H3YN

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

V E5B Snap-in I/O Module

hipecs-cio52 CANopen I/O module with 4 analog outputs

R3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP)

Communication & Networking

H3CA-8H-AC/100/110/120

THERMO-CON. Model No. HECR002-A5. Keep available whenever necessary.

hipecs-cio56 CANopen I/O module with PT100/1000 inputs

IO-DI8-RO4, IO-DI8-RO4-L I/O Expansion Modules 8 Inputs, 4 Outputs

TABLE OF CONTENTS. Communication Functions

General Description V TR34/V130-J-TR34 V TR34/V350-J-TR34 V430J-R34 V R34/V130-J-R34 V R34/V350-J-R34

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

EX-RC1 Remote I/O Adapter

MODEL: M1EXV. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

Communications & Networking

Transcription:

R7K4JML-E-DAFC64A INSTRUCTION MANUAL NPN/PNP DISCRETE HIGH SPEED INPUT & NPN TRANSISTOR OUTPUT MODULE ( 2 points each, tension clamp terminal block, MECHATROLINK-III use ) MODEL R7K4JML-E-DAFC64A BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any problems or questions with the product, please contact M-System s Sales Office or representatives. PACKAGE INCLUDES: Discrete I/O module...(1) DIN rail mounter slider...(2) MODEL NO. Confirm that the model number described on the product is exactly what you ordered. INSTRUCTION MANUAL This manual describes necessary points of caution when you use this product, including installation, connection and basic maintenance procedures. POINTS OF CAUTION CONFORMITY WITH EU DIRECTIVES The actual installation environments such as panel configurations, connected devices and connected wires may affect the protection level of this unit when it is integrated in a panel system. The user may have to review the CE requirements in regard to the whole system and employ additional protective measures to ensure CE conformity. POWER INPUT RATING & OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below: 24V DC rating: 24V ±10%, approx. 115mA GENERAL PRECAUTIONS Before you remove the unit or mount it, turn off the power supply, input signal and output signal for safety. Before you remove the terminal block or mount it, turn off the power supply, input signal and output signal for safety. ENVIRONMENT Indoor use When heavy dust or metal particles are present in the air, install the unit inside proper housing with sufficient ventilation. Do not install the unit where it is subjected to continuous vibration. Do not subject the unit to physical impact. Environmental temperature must be within -10 to 55 C (14 to 11 F) with relative humidity within 0 to 90% RH in order to ensure adequate life span and operation. WIRING Do not install cables close to noise sources (relay drive cable, high frequency line, etc.). Do not bind these cables together with those in which noises are present. Do not install them in the same duct. Be sure to close the terminal cover for safety. AND... The unit is designed to function as soon as power is supplied, however, a warm up for 10 minutes is required for satisfying complete performance described in the data sheet. EM-800-A P. 1 / 11

89ABCDEF0124567 89ABCDEF0124567 R7K4JML-E-DAFC64A FRONT VIEW MECHATROLINK-III Connector Station Address Setting Rotary SW Status Indicator LED Operating Mode Setting DIP SW (SW1) Discrete I/O Status Indicator LED PWR CON LNK2 ERR LNK1 LNK1 LNK2 SA1 10 SA2 1 Power Supply Connector Input Connector Output Connector STATUS INDICATOR LED ID COLOR FUNCTION PWR Green Turns on when the internal power is supplied normally. ERR Red Turns on at MECHATROLINK-III communication error CON Green Turns on at MECHATROLINK-III connection is established LNK1 Green Turns on at MECHATROLINK-III LNK1 is established LNK2 Green Turns on at MECHATROLINK-III LNK2 is established STATION ADDRESS Station Address is selected between 0H and EFH in hexadecimal. The SA1 switch determines the MSD, while the SA2 switch does the LSD of the address. (Factory setting: 0H) DISCRETE I/O STATUS INDICATOR LED LED green indicators shows the signal status. ON : LED ON OFF : LED OFF POWER SUPPLY TERMINAL ASSIGNMENT Applicable connector: TFMC1,5 / 5 STF,5 (Phoenix Contact) (included in the package) Applicable wire size: 0.2 1.5 mm 2 ; stripped length 10 mm Recommended solderless terminal AI0,25 10YE 0.25 mm 2 (Phoenix Contact) AI0,4 10TQ 0.4 mm 2 (Phoenix Contact) AI0,5 10WH 0.5 mm 2 (Phoenix Contact) AI0,75 10GY 0.75 mm 2 (Phoenix Contact) A1 10 1.0 mm 2 (Phoenix Contact) A1,5 10 1.5 mm 2 (Phoenix Contact) 1245 Station Address Setting (LSD) Station Address Setting (MSD) OPERATING MODE Acquire Cycle (SW-1, 2, ) SW1-1 SW1-2 SW1- ACQUIRE CYCLE OFF OFF OFF 100 μsec. (*) ON OFF OFF 200 μsec. OFF ON OFF 400 μsec. ON ON OFF 800 μsec. OFF OFF ON 4 msec. ON OFF ON 8 msec. OFF ON ON 16 msec. ON ON ON 40 msec. Output at loss of communication (SW1-4) SW1-4 Output at loss of communication OFF Reset the output (turned off) ON Hold the output (*) (maintains the last data received normally) (*) Factory setting 1. FE 2. NC. NC 4. +24V 5. 0V Functional Earth Power Input (24V DC) Power Input (0V) EM-800-A P. 2 / 11

R7K4JML-E-DAFC64A I/O TERMINAL ASSIGNMENT Applicable connector: DFMC1,5/18-ST-,5-LR (Phoenix Contact) (included in the package) Applicable wire size: 0.2 1.5 mm 2 ; stripped length 10 mm Recommended solderless terminal: AI0,25 10YE 0.25 mm 2 (Phoenix Contact) AI0,4 10TQ 0.4 mm 2 (Phoenix Contact) AI0,5 10WH 0.5 mm 2 (Phoenix Contact) AI0,75 10GY 0.75 mm 2 (Phoenix Contact) A1 10 1.0 mm 2 (Phoenix Contact) A1,5 10 1.5 mm 2 (Phoenix Contact) CONNECTING CONNECTORS Connectors with lock & release lever To connect, push the connector until the lock is latched. To disconnect, pull the lever toward to release the lock. Remove the connector. 1 2 4 5 6 7 8 9 10111211415161718 7 8 9 40 41 42 4 44 45 46 47 48 49 50 51 52 5 54 IN OUT 19 20 21 22 2 24 25 26 27 28 29 0 1 2 4 5 6 55 56 57 58 59 60 61 62 6 64 65 66 67 68 69 70 71 72 NO. ID FUNCTION NO. ID FUNCTION 1 COM In. Common 19 COM In. Common 2 COM In. Common 20 COM In. Common X0 Input 0 21 X16 Input 16 4 X1 Input 1 22 X17 Input 17 5 X2 Input 2 2 X18 Input 18 6 X Input 24 X19 Input 19 7 X4 Input 4 25 X20 Input 20 8 X5 Input 5 26 X21 Input 21 9 X6 Input 6 27 X22 Input 22 10 X7 Input 7 28 X2 Input 2 11 X8 Input 8 29 X24 Input 24 12 X9 Input 9 0 X25 Input 25 1 X10 Input 10 1 X26 Input 26 14 X11 Input 11 2 X27 Input 27 15 X12 Input 12 X28 Input 28 16 X1 Input 1 4 X29 Input 29 17 X14 Input 14 5 X0 Input 0 18 X15 Input 15 6 X1 Input 1 NO. ID FUNCTION NO. ID FUNCTION 7 V+ External excitation 55 V+ External excitation 8 V Out. Common 56 V Out. Common 9 Y0 Output 0 57 Y16 Output 16 40 Y1 Output 1 58 Y17 Output 17 41 Y2 Output 2 59 Y18 Output 18 42 Y Output 60 Y19 Output 19 4 Y4 Output 4 61 Y20 Output 20 44 Y5 Output 5 62 Y21 Output 21 45 Y6 Output 6 6 Y22 Output 22 46 Y7 Output 7 64 Y2 Output 2 47 Y8 Output 8 65 Y24 Output 24 48 Y9 Output 9 66 Y25 Output 25 49 Y10 Output 10 67 Y26 Output 26 50 Y11 Output 11 68 Y27 Output 27 51 Y12 Output 12 69 Y28 Output 28 52 Y1 Output 1 70 Y29 Output 29 5 Y14 Output 14 71 Y0 Output 0 54 Y15 Output 15 72 Y1 Output 1 EM-800-A P. / 11

R7K4JML-E-DAFC64A MOUNTING INSTRUCTIONS DIN RAIL MOUNTING Mounting 1 ) Set the upper hook at the rear side of the unit on the DIN rail. 2 ) Push in the lower. SURFACE MOUNTING 1 ) Insert the two DIN rail mounter sliders until it clicks once, as shown below. 1 1 2 2 ) Mount the unit with M4 screws referring the Mounting Requirements. (Torque: 1.4 N m) 1 Dismounting 1 ) Push down the DIN rail mounter slider with tip of a minus screwdriver. 2 ) Pull the lower of the unit. ) Remove the upper hook of the unit from the DIN rail. 2 1 1 1 EXTERNAL DIMENSIONS unit: mm (inch) 25 (9.25) 220 (8.66) 210 (8.27) 65 (2.56).5 (0.14) 5 (0.20) 50 (1.97) 2-4. dia. 4 deep (2-1.17 dia. 0.16 deep) DIN RAIL 5mm wide [4 (.16)] EM-800-A P. 4 / 11

R7K4JML-E-DAFC64A CONNECTION DIAGRAM Connect the unit as in the diagram below. COM COM X0 X1 X2 X X4 X5 X6 X7 X8 X9 X10 X11 X12 X1 X14 X15 COM COM X16 X17 X18 X19 X20 X21 X22 X2 X24 X25 X26 X27 X28 X29 X0 X1 1 2 4 5 6 7 8 9 10 11 12 1 14 15 16 17 18 19 20 21 22 2 24 25 26 27 28 29 0 1 2 4 5 6 MECHATROLINK-III CONNECTOR MECHATROLINK-III CONNECTOR 4 5 2 1 INPUT CONNECTION EXAMPLES * PNP Connection NPN Connection 7 V+ + + COM 1 COM 1 8 V COM 2 COM 2 9 Y0 COM 19 COM 19 40 Y1 COM 20 COM 20 41 Y2 X0 X0 42 Y * 4 Y4 24V DC 0V NC NC FE 44 Y5 45 Y6 46 Y7 47 Y8 48 Y9 49 Y10 50 Y11 51 Y12 52 Y1 5 Y14 54 Y15 55 V+ 56 V- 57 Y16 58 Y17 56 Y18 60 Y19 61 Y20 62 Y21 6 Y22 64 Y2 65 Y24 66 Y25 67 Y26 68 Y27 69 Y28 70 Y29 71 Y0 72 Y1 OUTPUT CONNECTION EXAMPLES V+ 7 V+ 55 V- 8 V- 56 Y0 9 Y1 72 X1 6 + X1 6 * The network cable can be connected to either one. Note: In order to improve EMC performance, bond the FE terminal to ground. Caution: FE terminal is NOT a protective conductior terminal. EM-800-A P. 5 / 11

R7K4JML-E-DAFC64A MOUNTING REQUIREMENTS unit: mm (inch) 2 - M4 220 (8.66) MECHATROLINK-III COMMUNICATION Transmission cycle:125 µsec., 250 µsec., 500 µsec., 1 64 msec. (with 1 msec. increments) Communication cycle: 125 µsec. through 64 msec. Applicable profile: Standard I/O profile (cyclic communication) Event-driven communication acquiring ID profile (event-driven communication) Transmission bytes: 16 bytes Station address: 0H through EFH (set with rotary switches) Cyclic communication: Available Event-driven communication: Available Slave monitoring: None MECHATROLINK-III COMMAND Commands available with this unit are the following. PROFILE COMMAND CODE FUNCTION Common command NOP 00H No operation command ID_RD 0H Read ID command CONFIG 04H Setup device command ALM_RD 05H Read alarm or warning command ALM_CLR 06H Clear alarm or warning command CONNECT 0EH Establish connection command DISCONNECT 0FH Release connection command Standard I/O profile DATA_RWA 20H Transmit I/O data NOP (00H) Does nothing except sending back current status 0 NOP (00H) NOP (00H) No operation command 4 00H 00H Reserve ID_RD (0H) Reads the product ID. 0 ID_RD (0H) ID_RD (0H) Read ID command 4 ID_CODE ID_CODE Refer to ID_CODE 5 OFFSET OFFSET OFFSET: designates the place to read data 6 SIZE SIZE SIZE: specify the size of data to read 7 8 00H ID Product's ID EM-800-A P. 6 / 11

CONFIG (04H) No parameter to set for this unit. Immediately response with completion. 0 CONFIG (04H) CONFIG (04H) Setup device command R7K4JML-E-DAFC64A 4 00H 00H Recalculation of parameters and set up. Other than 00H is not supported. 5 00H 00H Reserve ALM_RD (05H) Reads alarm or warning 0 ALM_RD (05H) ALM_RD (05H) Read alarm or warning command 4 0000H 0000H Read current alarm or warning. 5 12 points max. (2 bytes in 8th to 1st byte) Other than 0000H is not available. 6 0000H 0000H 0 7 8 00H 00H 0 ALM_CLR (06H) Clears alarm or warning 0 ALM_CLR (06H) ALM_CLR (06H) Clear alarm or warning command 4 0000H 0000H Clear current alarm or warning. Other than 0000H is not 5 6 00H 00H available. Reserve CONNECT (0EH) Starts communication with master station. 0 CONNECT (0EH) CONNECT (0EH) Establish connection command 4 0H 0H MECHATROLINK application layer: 0H 5 00H 00H Communication mode: Asynchronous, single transmission, subcommand disabled 6 COM_TIME COM_TIME Communication cycle: Multiple of transmission cycle. E.g. Transmission cycle: 0.5 msec, communication cycle: 2 msec. Set 4 (=2/0.5) 7 0H or 01H 0H or 01H Profile type 0H: Standard I/O 01H: Event-driven 8 00H 00H Reserve DISCONNECT (0FH) Stops communication with master station. 0 DISCONNECT (0FH) DISCONNECT (0FH) Release connection command 1 00H 00H Reserve EM-800-A P. 7 / 11

DATA_RWA (20H) Transmits I/O data to master station. Data allocation is following. Data size is 16 bytes. 0 DATA_RWA (20H) DATA_RWA (20H) Transmit data R7K4JML-E-DAFC64A 4 CH0 OUT LO CH0 IN LO CHx OUT: Output data: See 'Output Data of 'I/O DATA' 5 CH0 OUT HI CH0 IN HI CHx IN: Input data: See 'Input Data' of 'I/O DATA' 6 CH1 OUT LO CH1 IN LO 7 CH1 OUT HI CH1 IN HI 8 CH2 OUT LO CH2 IN LO 9 CH2 OUT HI CH2 IN HI 10 CH OUT LO CH IN LO 11 CH OUT HI CH IN HI 12 00H 00H Not used 14 00H 00H Not used 15 00H 00H Not used [ I/O DATA ] Input data Input data to be sent from the slave to the master are set in the response. CH0 IN LO CH0 data low 8 bits Bit 0 through 7 of the input data are set CH0 IN HI CH0 data high 8 bits Bit 8 through 15 of the input data are set CH1 IN LO CH1 data low 8 bits Bit 16 through 2 of the input data are set CH1 IN HI CH1 data high 8 bits Bit 24 through 1 of the input data are set CH2 IN LO CH2 data low 8 bits Bit 0 through 7 of the data, which reads back the input data, are set CH2 IN HI CH2 data high 8 bits Bit 8 through 15 of the data, which reads back the input data, are set CH IN LO CH data low 8 bits Bit 16 through 2 of the data, which reads back the input data, are set CH IN HI CH data high 8 bits Bit 24 through 1 of the data, which reads back the input data, are set Output Data Output data to be sent from the master to the slave are set in the command. Not used for input module. CH0 OUT LO CH0 data low 8 bits Not used CH0 OUT HI CH0 data high 8 bits Not used CH1 OUT LO CH1 data low 8 bits Not used CH1 OUT HI CH1 data high 8 bits Not used CH2 OUT LO CH2 data low 8 bits Bit 0 through 7 of the output data are set CH2 OUT HI CH2 data high 8 bits Bit 8 through 15 of the output data are set CH OUT LO CH data low 8 bits Bit 16 through 2 of the output data are set CH OUT HI CH data high 8 bits Bit 24 through 1 of the output data are set EM-800-A P. 8 / 11

R7K4JML-E-DAFC64A CMD_CTRL CMD_CTRL command area is following. BIT FUNCTION REMARKS 0-2 Reserve Not used ALM_CLR 0: Clear alarm/warning disabled 1: Clear alarm/warning triggered 4-5 Reserve Not used 6-7 CMD_ID Not used in the standard I/O command profile 8-15 Reserve Not used CMD_STAT CMD_STAT response area is following. BIT FUNCTION REMARKS 0 D_ALM Not used 1 D_WAR Not used 2 CMDRDY 1: Command reception enabled 0: Other ALM_CLR_CMP 1: Completion of execution of ALM_CLR 0: Other Cancellation of ALM_CLR_CMP causes ALM_CLR of CMD_CTRL to 0. 4-5 Reserve Not used 6-7 RCMD_ID Not used in the standard I/O command profile 8-11 CMD_ALM Warning 0: Normal, 1: Invalid data Alarm 8: Unsupported command received, 9: Invalid data, A: Command execution condition error, B: Subcommand combination error, C: Phase error 12-15 COMM_ALM Warning 0: Normal, 1: FCS error, 2: Command data not received, : Synchronous frame not received Alarm 8: FCS error, 9: Command data not received, A: Synchronous frame not received, B: Synchronization time interval error, C: WDT error EM-800-A P. 9 / 11

R7K4JML-E-DAFC64A ID_CODE ID_CODE is following. ID_CODE NAME SIZE (BYTES) SUPPORT VALUE (HEXADECIMAL) REMARKS 01 H Vendor ID Code 4 Yes 0x00000021 M-SYSTEM CO., LTD. 02 H Device Code 4 Yes 0x0000060 R7K4JML E DAFC64A 0 H Device Version 4 Yes Firmware version E.g. 1.00 -> 0x0064 04 H Device Definition File version 4 Yes 0x00001000 05 H Extended Address Setting 4 Yes 0x00000001 06 H Serial No. 2 Yes Unit serial number E.g. AB12456-> 0x214241 0x654 10 H Profile Type 1 4 Yes 0x0000000 Standard I/O profile 11 H Profile Version 1 4 Yes 0x00000100 12 H Profile Type 2 4 Yes 0x000000FF Indicates the unit does not support 1 H Profile Version 2 4 Yes 14 H Profile Type 4 Yes 0x000000FF Indicates the unit does not support 15 H Profile Version 4 Yes 16 H Min.Transmission Cycle 4 Yes 0x00000D4 125 µsec. 17 H Max.Transmission Cycle 4 Yes 0x0061A800 64 msec. 18 H Increments of Transmission Cycle 4 Yes 0x00000001 Available to 1.25, 62.5, 125, 250, 500 [µsec.] & 1 64 [msec.] (1 msec. increments) 19 H Min. Communication Cycle 4 Yes 0x00000D4 125 µsec. 1A H Max. Communication Cycle 4 Yes 0x0061A800 64 msec. 1B H Transmission Bytes 4 Yes 0x00000002 16 Bytes 1C H Transmission Bytes (Current Setting) 4 Yes 0x00000002 16 Bytes 1D H Profile Type (Current Selection) 4 Yes 0x00000001 / 0x0000000 Event-driven communication / Cyclic communication 20 H Supported Communication Mode 4 Yes 0x0000000 Event-driven communication / Cyclic communication 21 H MAC Address 4 No 0 H List of Supported Main Commands 8 H List of Supported Sub Commands 2 Yes 0x0000C079 0x00000001 2 No 40 H List of Common Parameters 2 No 80 H Main Device Name 2 Yes 0x44B752 0x4C4D4A 0x442D452D 0x644641 0x0000414 90 H Sub Device 1 Name 4 No 98 H Sub Device 1 Version 2 No A0 H Sub Device 2 Name 4 No A8 H Sub Device 2 Version 2 No B0 H Sub Device Name 4 No B8 H Sub Device Version 2 No ALM_CLR, ALM_RD, CONFIG, ID_ RD, NOP, DISCONNECT, CONNECT, DATA_RWA "R7K4JML E DAFC64A" EM-800-A P. 10 / 11

R7K4JML-E-DAFC64A I/O DATA DESCRIPTION DISCRETE I/O 15 0 Input 0 Input 1 Input 2 Input Input 16 Input 17 Input 18 Input 19 Output 0 Output 1 Output 2 Output Output 16 Output 17 Output 18 Output 19 Input 7 Input 8 Input 2 Input 24 Output 7 Output 8 Output 2 Output 24 Input 15 Input 1 Output 15 Output 1 0 OFF 1 ON EM-800-A P. 11 / 11