Flow Measurement SITRANS F C

Similar documents
Flow Measurement SITRANS F C

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

SITRANS F flowmeters. SITRANS F C Transmitter MASS 6000 for 19" insert/19" wall mounting. 4/134 Siemens FI

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Flow Measurement SITRANS F M. Transmitter MAG 5000/ /34 Siemens FI Overview

SITRANS F flowmeters. SITRANS F C System information MASSFLO coriolis mass flowmeters. 4/110 Siemens FI Overview

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F C

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/221

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M

5 Fieldbus Technology

PN DN FIG. 660D-BATT+670D-BATT 661D-BATT+670D-BATT SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE KAT KAT-06...

InCos-P Pressure sensor 20 Pa Pa

Level Measurement Continuous level measurement - Ultrasonic transmitters

MIC-2 MKII, Multi-instrument DATA SHEET

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

RHE27. Rack/Panel Mount Multifunction Coriolis Flow Transmitter

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

Level Measurement Continuous level measurement - Ultrasonic controllers

Flow Measurement SITRANS F US Clamp-on

Level Measurement Continuous level measurement Ultrasonic controllers

CPU module for zone 2 Series 9442/35

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

MIC-2 Multi-instrument DATA SHEET

Flow Measurement SITRANS F C

SITRANS T measuring instruments for temperature

Operating instructions. Switching amplifier DN0210 DN / / 2015

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level sensor Stainless steel version Model RLT-1000, for industrial applications

100mm Process Indicator Recorder

Electro-Magnetic Flowmeters Converters

RHE28. Field and Wall Mount Multifunction Coriolis Flow Transmitter

MID approval no. DE-08-MI004-PTB004 Date of release

Wall-/Pipe Mounted Universal Process Indicator

Flow Measurement SITRANS F C

Flow Measurement SITRANS F M. Transmitter MAG 5000/6000 4/33. Overview

RHE27 Rack/Panel Mount Multifunction Coriolis Flow Transmitter

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

RHE26. Rack/Panel Mount Multifunction Coriolis Flow Transmitter

Supplementary Components WirelessHART products

Technical Information RIA15

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Digital electropneumatic positioner

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

SITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview

VersaFlow TWC 9000/TWC 010 Coriolis Mass Flow Converter Technical Datasheet. Specification. The high-performance solution. Industries.

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Enclosures for Remote I/O System I.S. 1

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Continuous level measuring system NB 3000 Selection list

Flow Measurement SITRANS F US Clamp-on

RHE26. Rack/Panel/DIN Rail Mount Multifunction Coriolis Flow Transmitter

Online data sheet DUSTHUNTER SB100 SCATTERED LIGHT DUST MEASURING DEVICES

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

Micro Motion Model 2400S Transmitters with MVD Technology

Temperature Measurement SITRANS TS300

Flow Measurement SITRANS F US Clamp-on

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

/8 DIN Universal Process Indicator

Technical Information Fieldgate SFG500

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

the Interactive Catalog

PI-EX-ME-2NAM/COC-24VDC

SITRANS L Level instruments

SITRANS F flowmeters SITRANS F US. SITRANS FUE950 energy calculator. 4/240 Siemens FI

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

Immersion Temperature Sensors

Process Analysis Systems. Stratos Pro A4 MSPH/MSPH. Chem Energy Pharm Food Water. Connection

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Rotary Measuring Technology Absolute encoders, Singleturn, Profibus-DP

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

InBin-P Pressure switches from 5 Pa Pa

Digital electropneumatic Process Controller

Level Measurement Continuous level measurement - Ultrasonic controllers

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

MiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A...

Level Measurement Continuous level measurement - Ultrasonic controllers

Operating instructions. Speed monitor D / / 2014

Series 255. Flow Averaging Transmitter TECHNICAL SPECIFICATIONS

TRICOR Series TCM Coriolis Mass Flow Meters

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Tank-Display TA 1010 Content measurement for different formed tanks by hydrostatic pressure or distance measurement Features

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

SITRANS F Coriolis Flowmeters SITRANS FCT030 transmitter Quick Start

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

C160 Wall-/Pipe Mounted Universal Process Indicator

Rotary Measuring Technology Absolute encoders, Multiturn, Profibus-DP

Transcription:

Overview MASS 6 is based on digital signal processing technology engineered for high performance, fast flow step response, fast batching applications, high immunity against process noise, easy to install, commission and maintain. The MASS 6 transmitter delivers true multiparameter measurements i.e. mass flow, volume flow, density, temperature and fraction. The MASS 6 IP67 transmitter can be compact mounted on all sensors of type MASS 21 DI to DI 15, and can be used in remote version for all types of MASS 21 and FC sensors. Note Due to RoHs directives active from July 22 nd 217, MASS 6 transmitters of any model and variants are not for sale within EU, EU candidate countries, Norway, Switzerland, Iceland, Croatia, and Turkey. Replacement products: 7ME461.-..., 7ME462.-..., 7ME471.-... and 7ME481.-... Repair parts for MASS 6 (all models and variants) are available. See spare part list. Benefits Dedicated mass flow chip with the latest ASIC technology Fast batching and flow step response with an update rate of true Hz Superior noise immunity due to a DFT (Discrete Fourier Transformation) algorithm. Front end resolution better than.5 ns improves zero point stability and enhances dynamic turn-down ratio on flow and density accuracy. Advanced diagnosis and service menu enhances troubleshooting and meter verification. Built-in batch controller with compensation and monitoring comprising 2 built-in totalizers Multi-parameter outputs, individual configurable for mass flow, volume flow, density, temperature or fraction flow such as Brix or Plato Digital input for batch control, remote zero adjust or forced output mode All outputs can be forced to preset value for simulation, verification or calibration purposes. User-configurable operation menu with password protection - lines, 2 characters display in 11 languages - Self-explaining error handling/log in text format - Keypad can be used for controlling batch as start/stop/hold/reset SENSORPROM technology automatically configures transmitter at start-up providing: - Factory pre-programming with calibration data, pipe size, sensor type, output settings - Any values or settings changed by users are stored automatically - Automatically re-programming any new transmitter without loss of accuracy - Transmitter replacement in less than 5 minutes. - True "plug & play" 4-wire Pt1 temperature measurement ensures optimum accuracy on mass flow, density and fraction flow. Fraction flow computation based on a rd-order algorithm matching all applications. USM II platform enables fitting of add-on bus modules without loss of functionality. - All modules can be fitted through true "plug & play" - Module and transmitter are automatically configured through the SENSORPROM. Installation of the transmitter to the sensor is simple "plug & play" via the sensor pedestal. Application mass flowmeters are suitable for all applications within the entire process industry, where there is a demand for accurate flow measurement. The meter is capable of measuring both liquid and gas flow. The main applications for the MASS 6 IP67 transmitter can be found in: Food and beverage industries Pharmaceutical industries Automotive industry Oil and gas industry Power generation and utility industry Water and waste water industry Design The transmitter is designed in an IP67/NEMA 6 compact polyamide enclosure which can be compact mounted on the MASS 21 sensor range DI to DI 15 (1/8" to ½") and remote mounted for the entire sensor series. The MASS 6 IP67 is available as standard with 1 current, 1 frequency/pulse and 1 relay output and can be fitted with addon modules for bus communication. Function The following functions are available: Mass flow rate, volume flow rate, density, temperature, fraction flow 1 current output, 1 frequency/pulse output, 1 relay output, 1digital input All outputs can be individually configured with mass, volume, density etc. 2 built-in totalizers which can count positive, negative or net Low flow cut-off Density cut-off or empty pipe cut-off, adjustable Flow direction adjustable Error system consisting of error-log, error pending menu Display of operating time Uni/bidirectional flow measurement Limit switches with 1 or 2 limits, programmable for flow, density or temperature Noise filter setting for optimization of measurement performance under non-ideal application conditions Full batch controller Automatic zero adjustment menu, with zero point evaluation feed back Full service menu for effective and straight forward application and meter troubleshooting /214 Siemens FI 1 218

Technical specifications Measurement of Current output Mass flow [kg/s (lb/min)], volume flow [l/s (gpm)], fraction [%], Brix, density [kg/m, (lb/ft )], temperature [ C ( F)] Enclosure Material Fibre glass reinforced polyamide Rating IP67/NEMA 6 Mechanical load 18... 1 Hz random,.17 g RMS, in all directions Current... 2 ma or 4... 2 ma Supply voltage Load < 8 24 V version Time constant Digital output Frequency Time constant Active Passive Type Load Functions Digital input Functionality Galvanic isolation Cut-off Low-flow Limit function Totalizer Display.... s adjustable... 1 khz, 5 % duty cycle.... s adjustable 24 V DC, ma, 1 K R load 1 K, short-circuit-protected... V DC, max. 11 ma, 25 R load 1 K Change-over relay 42 V/2 A peak Error level, error number, limit, flow direction 11... V DC (R i = 1.6 k ) Start/hold/continue batch, zero point adjust, reset totalizer 1/2, force output, freeze output All inputs and outputs are galvanically isolated. Isolation voltage: 5 V to supply 5 V between outputs.... % of maximum flow Mass flow, volume flow, fraction, density, sensor temperature Two eight-digit counters for forward, net or reverse flow Background illumination with alphanumerical text, 2 characters to indicate flow rate, totalized values, settings and faults. Time constant as current output 1 Reverse flow indicated by negative sign Supply 18... V DC 2... V AC 2 V version Supply 87... 25 V AC, 5... 6 Hz Power consumption 24 V DC 6 W 24 V AC 1 VA 2 V AC VA Fuse 2 V version T 4 ma, T 25 V (IEC 127) - not replaceable by operator 24 V version T 1 A, T 25 V (IEC 127) - not replaceable by operator EMC performance Emission EN 5511/CISPR-11 (Class A) Immunity EN/IEC 6126-1 (Industry) NAMUR Within the value limits according to "General requirements with error criteria A in accordance with NE 21 Environment Environmental conditions acc. to Altitude up to 2 m IEC/EN/UL 611-1: POLLUTION DEGREE 2 Maintenance The flowmeter has a built-in error log/pending menu which should be inspected on a regular basis. Cable glands Two types of cable gland are available in polyamide in the following dimensions: M2 or ½ NPT Note Due to RoHs directives active from July 22 nd 217, MASS 6 transmitters of any model and variants are not for sale within EU, EU candidate countries, Norway, Switzerland, Iceland, Croatia, and Turkey. Zero point adjustment Via keypad or remote via digital input Replacement products: 7ME461.-..., 7ME462.-..., 7ME471.-... and 7ME481.-... Ambient temperature Operation -2... +5 C (-4... +122 F), max. rel. humidity 8 % at 1 C (87.8 F) decreasing to 5 % at 4 C (14 F) according to IEC/EN/UL 611-1 Repair parts for MASS 6 (all models and variants) are available. See spare part list. Storage -4... +7 C (-4... +158 F) (Humidity max. 5 %) Communication Add-on modules: HART, PROFIBUS PA and DP, Modbus RTU RS 485,, FOUNDATION Fieldbus H1 Siemens FI 1 218 /215

Selection and Ordering data MASS 6 transmitter 7 M E 4 1 1 - Transmitter for wall mounting with wall mounting bracket, fibre glass reinforced polyamide (1 current 7 A A 7-7 7 A 7 output, 1 frq./pulse output, 1 relay output and connection board/pcb) Click on the for the online configuration in the PIA Life Cycle Portal. Version Remote IP67/NEMA 6 enclosure 2 Supply voltage 115/2 V AC, 5... 6 Hz 1 24 V AC/DC 2 Display/Keypad with display 1 Serial communication No communication A HART B PROFIBUS PA Profile F PROFIBUS DP Profile G Modbus RTU RS 485 E H FOUNDATION Fieldbus H1 J Cable glands M2 1 ½ NPT 2 Operating instructions for MASS 6 IP67 A5E716 All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation Accessories Cable glands, screwed entries type in polyamide (1 C (212 F)) black, 2 pcs. M2 A5E8224 ½ NPT A5E82251 Sun lid for MASS 6 transmitter (Frame and lid) A5E228485 Add-on module HART 1) PROFIBUS PA Profile 1) PROFIBUS DP Profile Modbus RTU RS 485 FOUNDATION Fieldbus H1 1) 1) FDK:85U226 FDK:85U26 FDK:85U27 FDK:85U24 A5E25425 FDK:85U22 Modules are rated Ex i when used with MASS 6 Ex d. Operating instructions for SITRANS F add-on modules HART PROFIBUS PA/DP Modbus FOUNDATION Fieldbus A5E878 A5E72617 A5E12642 A5E7574 A5E8262 A5E218728 A5E2488856 A5E872 All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation Spare parts for compact or remote IP67 version MASS 6 transmitter IP67/NEMA 6 Fibre glass reinforced polyamide and without connection board 1 current output 1 frq./pulse output 1 relay output 115/2 V AC, 5/6 Hz 7ME411-1AA1-1AA 24VAC/DC 7ME411-1AA2-1AA Wall mounting unit for IP67/NEMA 6 version with wall bracket, without connection board but with 4 x M2 cable glands FDK:85U118 4 x ½ NPT cable glands A5E1164211 Connection board/pcb Supply voltage: 115/2 V/24 V AC/DC FDK:8H426 /216 Siemens FI 1 218

Terminal box kit with M2 cable glands A5E828 ½ NPT cable glands A5E8242 Change from remote to safe area compact mounting of MASS 6 IP67/NEMA 6 with MASS 21. The kit consists of a terminal box in polyamide incl. connection board, cable and connector between PCB and sensor pedestal, PCB, seal and screws (4 pcs.) for mounting on sensor. Not approved for hazardous locations Terminal box, in polyamide, inclusive lid M2 cable glands FDK:85U15 ½ NPT cable glands FDK:85U152 Not approved for hazardous locations Terminal box lid in polyamide FDK:85U1 Display and keypad Siemens Front FDK:85U1 Add-on spare parts required due to RoHs directives and EoL for EU and EU related countries MASS 6 IP67 2 V 24 V MASS 6 1"/IP2 1 current output 2 V current outputs 2 V 1 current output 24V current outputs 24 V MASS 6 1"/IP2 Ex 1 current output 2 V current outputs 2 V 1 current output 24V current outputs 24 V MASS 6 Ex d, Spare part PCB Stainless steel, without module A5E4171818 A5E4171846 A5E422618 A5E4226145 A5E4226154 A5E4226168 A5E4226277 A5E422642 A5E4226441 A5E4226455 FDK:8H61 MASS 6 Ex d, Spare part barriere Stainless steel A5E4171872 MASS 6 1"/IP2, Barriere PCB, Ex A5E4171866 MASS 6 Ex d, Connection board Stainless steel A5E41718522 MASS 6 IP2, Front plate Without display A5E4171865 MASS 6 IP2, Front plate, Ex Without display A5E4171876 Siemens FI 1 218 /217

Dimensional drawings Compact with MASS 6 IP67 Schematics Electrical connection Grounding must be connected due to safety class 1 power supply. Mechanical counters When mounting a mechanical counter to terminals 57 and 58 (active output), a 1 µf min. 5 V electrolytic capacitor must be connected to the terminals 56 and 58. Capacitor + is connected to terminal 56 and capacitor - to terminal 58. Output cables If long cables are used in a noisy environment, it is recommended to use shielded cables. Transmitter Dimensions in mm (inch) MASS 21 with MASS 6 IP67 compact Sensor size [DI (inch)] L H 5 H 6 H 5 + H 6 N L N 1) 15-2 V AC L 2) 1 2 18 - V DC 2 - V DC (1/8) 75 (2.5) 82 (.2) 6 (12.4) 88 (15.28) 6 (¼) 62 (2.44) 72 (2.8) 16 (12.44) 88 (15.28) 15 (½) 75 (2.5) 87 (.4) 26 (12.8) 41 (16.26) Transmitter MASS 6 IP67 wall mounted Current output 1 2 44 45 46 shown in de-energised condition /4-2 ma Load 8 Ω V AC / 2 A V AC / 2 A 71 (2.8) Passive output max. V/11 ma 56 56 57 57 Ø8 (.1) Ø12 (.47) Ø8 (.1) 1 (.51) 1 (.51) 71 (2.8) 24 (.45) 155 (6.1) 12 (4.2) Digital input 58 77 78 MASS 6 IP67 24 V 58 11 - V DC MASS FC 155 (6.1) (1.18) 5 (2.) 17 (6.7) Driver 81 82 Brown Red MASS 21 1 2 Dimensions in mm (inch) TEMP.SENSE IN 8 84 Orange Yellow 4 TEMP.SENSE OUT Pick-up 1 8 85 86 White Black Green Blue 5 6 Pick-up 2 87 88 Violet Gray 7 8 /218 Siemens FI 1 218