Posi-Lok Plugs and Panels

Similar documents
Arrow Hart. Mission critical power when and where you need it. Lorem ipsum dolor sit amet Lorem ipsum dolor sit amet

M-Line Series MN Multi-Pin Plugs and Receptacles Vac, Vdc

Standard Buccaneer BUCCANEER FOR POWER

Amphenol Miniature Cylindrical Proprietary/MIL-C-26482, Series 1

EFP SERIES FLAMEPROOF ELECTRICAL CONNECTORS FOR HAZARDOUS ENVIRONMENTS

Cord- Mounted Female. Mounted Male. Strain relief clamp # needs to be ordered separately w/cord-mounted connections.

Summary of shell housings and accessories Shell housing A Shell housing D EMC housing

E1135C PDU and Pod Upgrade Procedure

Amphenol Miniature Cylindrical Proprietary/MIL-C-26482, Series 1

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS

ASCO 920 Remote Control (RC) Switches

2013 ESL Power Systems, Inc. All Rights Reserved.

Time Delay Values (E-Series)

DIN Molded Cable Assemblies

Industrial Ethernet Panel-Mount Adaptors for PROFINET or EtherNet/IP Applications

CONNECTORS & RECEPTACLES

920 Remote Control (RC) Switches

1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist.

JAN 16 Rev B

PV Rapid Shutdown device

industrial panel lamps

Sensor Connectivity Introduction Global Plus Connector Cables Multi-Connector Blocks. Product Selection Guide...

Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and gold plated contacts available High

SAVE THESE INSTRUCTIONS

Instruction Sheet Board Style Low Water Cutoff

SERVICE PARTS MANUAL

Switch rated plugs and receptacles with NEMA 4X protection

Inductive Proximity Sensors E51 Limit Switch Style, Modular

TABLE OF CONTENTS. IEC and IEC Pin and Sleeve Devices. IEC and IEC Mechanical Interlocks. Manual Disconnect Switches

CONNECTOR AND RECEPTACLE WIRE/CABLE ASSEMBLY INSTRUCTIONS

Connector System for Fluorescent Lighting Fixtures. Connectors for In-Line Mounting of Fluorescent Lighting Fixtures. Fully Polarized Connectors

07. har-link Interface Connectors

M12 Field Wireable Connectors. M12 CAT.6A Field Wireable Connectors. M12 Field Wireable Connectors for PROFINET

Modular plugs, accessories and tooling

EPIC Circular Connectors CIRCON M23 Series

PRO REMOTE 25 LV CAPACITANCE PROBE

C-Series. Circuit Breaker

v1.0 JL10 Series Circular Waterproof Connector Connector Training Module Copyright 2015 JAE Electronics, Inc.

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

ASCO SERIES 300 Manual Transfer Switch Solutions

BUSBAR CONNECTIVITY QUICK REFERENCE GUIDE

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158

Power Base AI. Power Base AI. Technical Sheets

C-Series. Circuit Breaker

ANSI C Dimming Receptacles

E-Series General Specifications

IP68 Sealed - Mini USB Buccaneer

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Pile Driver Weld Immune Sensors

2M Series Selection Table. 2M801, 2M803, 2M804 and 2M805

07. har-link INTERFACE CONNECTORS

FDS / FDS-R / FDS-PS

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

PN PSTK-120 PowerSwitch Tail 120vac Kit PN PSTK-240 PowerSwitch Tail 240vac Kit

Ringlock is a range of robust circular

USB Buccaneer BUCCANEER

This Datasheet is for the IC693CBL300. I/O Bus Expansion Cables.

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

49 Series Connectors and Receptacles. A Comprehensive Line of Rugged, High Amperage Electrical Connections for the Most Demanding Environments

Ground Power Modules. And Accessories For Healthcare Facilities. Technical Bulletin NAE /

AX SERIES XLR CABLE CONNECTORS

Bulletin 871D Cylinder Position Inductive Style

EXTreme Guardian Power Connector System

Adapter Kit - QSI Electronics to G-Series Meter Installation Instructions

Standard Products Assembly Equipment Table 3M Electronic Products Division

07. har-link Interface Connectors

CONNECTORS & RECEPTACLES

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

RECTANGULAR POWER CONNECTORS

EPIC LS1 Series Circular Power & Mixed Power Connectors

Microinverters And The Solar Industry

Combo 2 Port Usb Receptacle 15A 125V Iv 15A 125V 2P IV USB RECEPT COMBO 2 PORT USB RECEPTACLE 15A 125V IV

Terminals, Lugs, and Fasteners

SERVICE PARTS MANUAL

Photoelectric Sensors Enhanced 50 Series

Zenith Series DPB Distributed Power Busway

B Y R N E 8 - T R A C O V E R V I E W. 1) Introduction. 2) Universally Recognized. 3) Circuitry/Keying

ArmorConnect Power and Control Media

WINSTA. Full Line Catalog 2008/2009

Revised: Page 1

EN3 SERIES WEATHERTIGHT CONNECTORS NEW PRODUCT BULLETIN 602

versatile connectors for any application

SERVICE PARTS MANUAL

Panduit Basic Rack PDU

APL/UPL, 205/295 Series Magnetic Circuit Protectors

Connecting Power and Ground

Special Purpose Plugs and Receptacles

High Current Products Catalog Revised 4-01

High Current Products Catalog Revised onlinecomponents.com

CW INDUSTRIES IDC SELECTION GUIDE

POSEIDON SCIENTIFIC INSTRUMENTS PTY LTD 17 QUEEN VICTORIA ST, FREMANTLE WA PHONE (08) FAX (08) MWA-3014

Photoelectric Sensor

Electrical Test voltage (Vrms) Service sea level at m M I II

LZ Series Multi-Pin Connectors

Ethernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 12

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

Installation manual for for Schleifenbauer DPM3

LED. Sign Module. Assembly Manual

Progressive Industries, Inc. EMS Electrical Management System

Compact, Low Profile High Rendering, 100% Diffusion

Transcription:

THE SAFEST ELECTRICAL SYSTEM FOR HIGH AMPERAGE CONNECTIONS, POSI-LOK IS PART OF THE CAM-LOK FAMILY OF CONNECTORS. THE GROUND ALWAYS MAKES FIRST AND BREAKS LAST ALL POSI-LOK SYSTEMS ARE UL LISTED AND CSA CERTIFIED. PATENT #4,767,347 UL FILE NUMBER E67181 CSA FILE NUMBER LR13963-48 Posi-Lok Connectors The Posi-Lok Power Distribution System from Cooper Interconnect brings a new level of safety to electrical power applications. Now there s no need to haul around python-sized, multi-conductor cables. Posi-Lok Power Distribution Systems let you use lighter, single conductor cables rated at higher amperages. Designed to meet Article 520-53 Section K and Article 530-22 Section A (NEC) standards, Posi- Lok s built-in safety features require the user to connect or disconnect each plug in sequence. Protective covers cannot be raised until the preceding plug is locked into position. The disconnect sequence is reversed. Posi-Lok plugs feature recessed electrical contacts that are protected by shatter-resistant synthetic rubber insulators and impact-resistant molded sleeves. NEC IS A REGISTERED TRADEMARK OF THE NATIONAL FIRE PROTECTION ASSOCIATION INC. The same plugs that connect to panels also connect to each other so that you can use long runs of cable. Polarity is assured because each plug is uniquely keyed and color-coded for easy, positive connecting. IN-LINE PLUGS MAKE CABLE EXTENSIONS QUICK AND EASY 76 4758 Washington Street LaGrange, NC 28551 252-566-3014 www.cooperinterconnect.com

SPECIFICATIONS There is a Posi-Lok system for every application The Cam-Lok double cam principle provides a positive vibration-proof connection. Just 1/3 of a turn assures a high pressure contact with minimum electrical resistance. The self-wiping action maintains clean contact surfaces. The patented design is self-compensating for wear. COOPER INTERCONNECT OFFERS UL LISTED AND CSA CERTIFIED POSI-LOK SYSTEMS IN THE SIZES YOU NEED MOST...200, 315, AND 400 AMPERES. YOU CAN ORDER OPTIONAL SIX-POSITION PANELS WHICH INCLUDE A DOUBLE NEUTRAL POSITION TO SOLVE HARMONIC PROBLEMS IN YOUR DISTRIBUTION SYSTEM. THESE SYSTEMS WERE DESIGNED WITH THE USER IN MIND. THE 315 AND 400 AMP PANELS CAN BE INSTALLED INTO A STANDARD 19-INCH RACK. THE 200 AMP PANEL REQUIRES AS SMALL AS A 13.5-INCH WIDE SPACE. SEE PAGES 81 AND 91 FOR MOUNTING DIMENSIONS. CONSULT FACTORY FOR ADDITIONAL POLARIZING CONFIGURATIONS. Posi-Lok panels are Lockout-Tagout compatible. - Lock the grounding cover and the entire panel system cannot be used. - Lock the fourth cover when single phase, 3-wire system is desired. - Lock fifth cover when 4-wire system is desired. 77 Cooper Interconnect 4758 Washington Street LaGrange, NC 28551 252-566-3014

SPECIAL FEATURES MORE THAN 20 YEARS OF FIELD TESTING HAS PROVEN THAT THE UNIQUE SYNTHETIC RUBBER, TAPERED INSULATOR ALLOWS MAXIMUM FLEXING WITH MINIMUM BREAKAGE. THERE ARE NO METAL CLAMPS OR GROMMETS TO CAUSE CABLE FAILURE. Termination barrel (set screw version shown). Crimp style also available O-Ring Contact retaining nut Built-in strain relief reduces cable strand breakage Cable jacket retaining wire Impact-resistant polarizing sleeve Recessed contacts Standard Materials SERIES NUMBER RECEPTACLES PER PANEL AMP RATING MAXIMUM VOLTAGE CONTACT MATERIAL MAXIMUM CABLE SIZE CABLE TERMINATION TEMP RATING E0200 3, 4, 5, or 6 200 600 AC/DC (UL) 600 AC (CSA) Silver Plated Copper 2/0 Crimp and Set Screw 1050C The E0200 Series male connector is typically the output side. 78 4758 Washington Street LaGrange, NC 28551 252-566-3014 www.cooperinterconnect.com

FEMALE PANEL PART NUMBERS RECEPTACLES PER PANEL FEMALE PANELS COVER COLOR CODE 3 E0200-1685 GR, WH, BK 4 E0200-1686-NN GR, BK, RD, BU 3, 4, 5 OR 6 WIRE SYSTEM, RATEDUPTO 200 AMPS, CONTINUOUS, 600 VOLTS, 105 0 C. 4 E0200-1696 GR, WH, BK, RD 4 E0200-1892-NN GR, BRN, ORG, YEL 5 E0200-1687 GR, WH, BK, RD, BU 5 E0200-1890 GR, WH, BRN, ORG, YEL 6 E0200-1885 GR, WH, WH, BK, RD, BU GR = Green WH = White BK = Black RD = Red BU = Blue BRN = Brown ORG = Orange YEL = NN = Panel without Neutral Other Color Codes available; consult factory. Add LS suffix to end of part number to order panels with a limit switch. Available on last position only. Example: E0200-1687LS. Limit switch ratings are 5A, 250VAC. Plugs must be ordered separately. See below. Male Plug Assembled length is 8 3/4 MALE PLUG DESCRIPTION POSITION MALE COMPLETE MALE CONTACT ONLY MALE INSULATOR POLARIZING SHELL Crimp Green E0200-141 A201293-5 A201315-3 #2-2/0 White E0200-142 A201293-5 A201315-2 Black E0200-143 A201293-5 A201315-1 #2=190 AMPS Red E0200-144 A201293-5 A201315-5 #1=200 AMPS Blue E0200-145 A201293-5 A201315-4 #1/0=200 AMPS Brown E0200-147 A201293-5 A201315-9 E0200-148 E0200-149 A201293-5 A201293-5 A201315-10 A201315-8 Double Set Screw Green E0200-181 A201315-3 #2-2/0 White Black E0200-182 E0200-183 A201315-2 A201315-1 #2=190 AMPS Red E0200-184 A201315-5 #1=200 AMPS Blue E0200-185 A201315-4 #1/0=200 AMPS Brown E0200-199 A201315-9 E0200-195 E0200-192 A201315-10 A201315-8 NOTES: AMPACITY IS BASED ON CABLE SIZE OR CONTACT RATING, WHICHEVER IS LESS. PANEL DOES NOT INCLUDE ENCLOSURE OR BREAKERS. POSI-LOK SYSTEM MUST BE INSTALLED PER LOCAL AND NATIONAL STANDARDS. PANEL RECEPTACLES HAVE LOCK WASHERS, FLAT WASHERS AND JAM NUTS INCLUDED. 79 Cooper Interconnect 4758 Washington Street LaGrange, NC 28551 252-566-3014

3, 4, 5 OR 6 WIRE SYSTEM, RATED UP TO 200 AMPS, CONTINUOUS, 600 VOLTS, 105 0 C. MALE PANEL PART NUMBERS RECEPTACLES PER PANEL MALE PANELS COVER COLOR CODE 3 E0200-1660 GR, WH, BK 4 E0200-1661-NN GR, BK, RD, BU 4 E0200-1672 GR, WH, BK, RD 4 E0200-1893-NN GR, BRN, ORG, YEL 5 E0200-1662 GR, WH, BK, RD, BU 5 E0200-1891 GR, WH, BRN, ORG, YEL 6 E0200-1860 GR, WH, WH, BK, RD, BU GR = Green WH = White BK = Black RD = Red BU = Blue BRN = Brown ORG = Orange YEL = NN = Panel without Neutral Other Color Codes available; consult factory. Add LS suffix to end of part number to order panels with a limit switch. Available on last position only. Example: E0200-1662LS. Limit switch ratings are 5A, 250VAC. Plugs must be ordered separately. See below. Female Plug Assembled length is 8 3/4 FEMALE PLUGS NOTES: AMPACITY IS BASED ON CABLE SIZE OR CONTACT RATING, WHICHEVER IS LESS. PLUGS AND PANELS HAVE SILVER PLATED COPPER CONTACTS. PANEL DOES NOT INCLUDE ENCLOSURE OR BREAKERS. POSI-LOK SYSTEM MUST BE INSTALLED PER LOCAL AND NATIONAL STANDARDS. PANEL RECEPTACLES HAVE LOCK WASHERS, FLAT WASHERS AND JAM NUTS INCLUDED. DESCRIPTION POSITION FEMALE COMPLETE FEMALE CONTACT ONLY FEMALE INSULATOR/ POLARIZING SHELL Crimp Green E0200-241 A201292-5 A201315-27 #2-2/0 White Black E0200-242 E0200-243 A201292-5 A201293-5 A201315-26 A201315-25 #2=190 AMPS Red E0200-244 A201292-5 A201315-29 #1=200 AMPS Blue E0200-245 A201292-5 A201315-28 #1/0=200 AMPS Brown E0200-247 A201292-5 A201315-33 E0200-248 E0200-249 A201292-5 A201292-5 A201315-34 A201315-32 Double Set Screw Green E0200-281 A201315-27 #2-2/0 White Black E0200-282 E0200-283 A201315-26 A201315-25 #2=190 AMPS Red E0200-284 A201315-29 #1=200 AMPS Blue E0200-285 A201315-28 #1/0=200 AMPS Brown E0200-288 A201315-33 E0200-289 E0200-286 A201315-34 A201315-32 80 4758 Washington Street LaGrange, NC 28551 252-566-3014 www.cooperinterconnect.com

.51.65 3.11 2.68 1.25 Limit Switch Available In Last Position Only 1.47 2.68 3, 4, 5 OR 6 WIRE SYSTEM, RATEDUPTO 200 AMPS, CONTINUOUS, 600 VOLTS, 105 0 C. 12.05 Inside For 6 Position Panel 13.41 Overall Length for 6 Position Panel 1.00.25.33 3.28 4.53 3/8-16 Thread.51.65 3.11 1.25 2.78 10.07 Inside For 5 Position Panel 11.43 Overall Length for 5 Position Panel 1.00.25.33 3.28 4.53 3/8-16 Thread 8.09 Inside For 4 Position Panel 9.45 Overall Length for 4 Position Panel 6.11 Inside For 3 Position Panel 7.47 Overall Length for 3 Position Panel All measurements are in inches 81 Cooper Interconnect 4758 Washington Street LaGrange, NC 28551 252-566-3014