INDIAN INSTITUTE OF TECHNOLOGY DEPARTMENT OF CIVIL ENGINEERING

Similar documents
RAIN GAUGE TIPPING BUCKET TYPE

WHIRLYBIRD AUTOMATIC WEATHER STATION. Whirlybird Electronics Pvt Ltd 140, 2 nd Cross 13 th Main, BTM-I Bangalore

A EX I. Automatic Weather Station:

IMS4 AMS 111 II M. Automatic Mobile Weather Station for military usage AMS 111 II M

GS828-H. GPRS Data Logger

Advancement of Community Weather Information Network through the Use of Low cost Automatic Weather Station

IMS AMS 111 II. Automatic Weather Station. Easy and reliable weather monitoring anywhere

AWA6223S Sound Level Calibrator. Instruction Manual HANGZHOU AIHUA INSTRUMENTS CO., LTD

GS828. GPRS Data Logger

SHAILRON Technology SOLAR MONITORING SYSTEM

PTU300 Combined Pressure, Humidity and Temperature Transmitter

Hydrological Information System

UNIVERSITY OF CALCUTTA Centre for Research in Nanoscience and Nanotechnology JD-2, Sector-III, Salt Lake City Kolkata

PROFESSIONAL WIRELESS WEATHER STATION. Operation Manual - 1 -

PRO11. Weather Station CaipoBase

The framework of next generation automatic weather station in China

AUTOMATIC AND AUTONOMOUS REMOTE WATER LEVEL AND WATER QUALITY MONITORING STATION

Datalogger Gealog SG. Datalogger Gealog SG. Gealog SG with graphic display

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

DCT7088 Portable Digital Correlation Transit Time Flowmeter

In North America call toll free: Fax

DATA LOGGER APPLICATION DEVELOPMENT USING MICROCONTROLLER ATMEGA 128 FOR A WEB-BASED GPRS COMMUNICATION

Low Power Modbus GPRS Data Logger

AANDERAA. DATALOGGERS 3634 and 3660

icp 1000 Wireless GSM Based Remote Monitoring Unit for Transformer Rectifier Unit

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values

Supply voltage. Input current. Encoder supply. Memory

INVITATION FOR QUOTATION. TEQIP-II/2015/KL1G17/Shopping/152

Sub: Invitation of sealed quotations for Procurement of UPS systems for MDI Gurgaon

Interface BL232 with RS232/422/485 MODBUS and 0-10V outputs. Interface BL232

HW4 Software version 3. HP23 Humidity Temperature Indicator

HD32MT.1. Programmable Data Logger ENGLISH

General information. Display. Supply voltage. Input current. Encoder supply. Output current

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation

( F L O W I Z F A M I L Y )

HD HD [ GB ] Probes for soil volumetric water content measurement. Temperature. Humidity PART OF G H M GROUP TELEMETRIE & AUTOMATION

TSM - Temperature Sensor Meter

GOVERNMENT OF ASSAM. JORHAT : , ASSAM Ph : INVITATION FOR QUOTATION. TEQIP-III/2019/jejc/Shopping/20

and/or b. an optional internal Iridium satellite modem.

NATIONAL INSTITUTE OF TECHNOLOGY, TIRUCHIRAPPALLI INVITATION FOR QUOTATION. TEQIP-III/2017/NITT/Shopping/44

Integrating Digiquartz MET3 and MET3A Broadband Meteorological Systems with a Trimble NetRS GPS Receiver

Multi-range pressure and differential pressure transmitter

blueberry Intelligent data acquisition for wind energy, meteorology and industry Capturing the Future

Indian Institute of Technology, Kharagpur Kharagpur , WB, India

GPS Vehicle Tracker (GPS+GSM+SMS/GPRS) User Manual (A5E-3)

MULTI PARAMETER WATER QUALITY SENSORS

THE WORLD OF WEATHER DATA

Department of Mechanical Engineering, Indian Institute of Technology Madras Chennai 36

Data Sheet. RS Datascan data acquisition system

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

INVITATION FOR QUOTATION. TEQIP-II/2017/UK1G01/Shopping/84

Digital Humidity & Temperature Sensor. With Two-Wire Interface

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

TEMPERATURE - HUMIDITY ELEKTRONIK EE08

GPRS-T1. Monitoring Converter. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

NX21 USER MANUAL. Telemetry Unit. Version 1.5

General information. Display. Supply voltage. Input current

CNC Tube Bending Machine & its Software (On Turn key basis) SL. NO. DESCRIPTION OF REQUIREMENT REQUIRED 1 Scope

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

ETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

General information. Display. Supply voltage. Input current

TECHNICAL SPECIFICATION OF GPRS based MODEM (Part 1)

General information. Display. Supply voltage. Input current. Encoder supply. Output current

HL20-A Measurement and Control System

General information. Display. Supply voltage. Input current. Encoder supply. Output current

REQUIREMENTS FOR WIRELESS, WEB-BASED MONITORING EQUIPMENT AND SERVICES FOR PUMP STATION APPLICAITONS

log TM Humidity. Temperature. Voltage. Current. Radiation. Pulse. Light. Pressure. DATA LOGGING. SIMPLY.

Real Time Data Acquisition System for Flood Forecasting

EC 600 Electronic Volume Corrector

User's Guide. Vane Thermo-Anemometer Datalogger. Model Introduction

ERNAKULAM DISTRICT. Quotation for supply of Laptop to Head Office on buy-back scheme

Meter Scanner & Controller

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

PRO194. IrriWave Wireless Irrigation Control

DS BAS 08/99 UNC 532

IWMI Mobile Weather Station

RAJIV GANDHI UNIVERSITY OF KNOWLEDGE TECHNOLOGIES BASAR Nirmal District, Telangana Ref: RGUKT-B/Proc/Firewall/Q104/2016, dated

HOBO Energy Monitoring. Product Selection Guide

INVITATION FOR QUOTATION. TEQIP-III/2019/iiit/Shopping/56/5302. Sub: Invitation for Quotations for supply of Desktop Computers.

Wide measurement range Temperature operating range is 10 to 65ºC (15 to 150ºF); RH range is 0 to 99% non-condensing.

HUMLOG 10. Manual. Status V4 (02/2010)

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Quotations invited. 2. The supplied hardware should have 5 years comprehensive onsite warranty (24 x 7 call logging) from OEM directly.

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

ULTRALOW POWER 24-BIT DUAL SEISMIC DATA RECORDER WITH INTERNAL SCU CONTROLLER Model DR4050-A-SCU/IF

IP68. Autarkic Data Loggers - MT-051 / MT-713 / MT-723

General information. Display. Supply voltage. Input current

Please note that your offer should be only in the enclosed format duly signed by the authorised signatory on each page along with seal of your firm.

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

St. Edmund s College

Department of Electrical Engineering

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

General information. Display. Supply voltage. Input current

Transcription:

INDIAN INSTITUTE OF TECHNOLOGY DEPARTMENT OF CIVIL ENGINEERING Sub: Quotation for supply of Weather Station Enquiry letter for Weather Station Reference: IITK/SERB/2017-3-1 Dated 31.03.2017 Sir / Madam, With reference to the subject mentioned above, you are invited to submit the quotation in a sealed cover for supply and installation of an automatic weather station with the following items. Technical specification of the items are given in Annexure 1 and 2: a. Rain-gauge, wind speed, wind direction, pressure sensor, solar radiation and evaporation sensors (1 unit) b. Relative humidity and temperature sensors (2 units) c. Solar powered data logger(s) based system with Data Shuttle and PC interface kit. d. Gsm Gprs based telemetry The weather station has to be installed at IIT Kanpur in Kanpur district of Uttar Pradesh. The quotation should have the following details: 1. The rates should include all taxes, installation and commission of the station, along with AMC for a minimum of three year. 2. Cost of each item/sensor separately 3. Technical specifications in detail 4. Warranty period 5. Educational discount considering end use for research and teaching 6. Payment terms 7. Proprietary Certificate, if applicable 8. Any other relevant details Terms and conditions:- 1. Sealed Quotation must reach to us till 13 th April, 2017 before 5.00PM 2. Prices should be in Indian Rupees. 3. Normal payment terms for the Institute will be applicable (90% on delivery of the items and remaining 10% after satisfactory installation/inspection). 4. For providing after sales service for the AWS. The vender should have proper service support at the observatory. The vendor should have adequate service persons, spares & standby AWS facility.

5. Single point of contact for support: Vender has to provide details of single point of contact viz. Designation, address, and email address, telephone/mobile no. Escalation matrix for support should also be provided with full details. Richa Ojha Assistant Professor Department of Civil Engineering Indian Institute of Technology Kanpur 208016 Tel. 0512-259-6564 E-mail: richao@iitk.ac.in

Annexure 1: Technical specification of the sensors Sl. Parameter Feature Specification No. 1 Air Temperature Range -10 C to +60 C Accuracy ±0.2 C or better (with radiation shield) Resolution ±0.1 C Response Time 10 sec or better 2 Wind Speed Range 0 to 60m/s or better Sustainability Up to 75 m/sec Accuracy ±0.5 m/s or better Resolution 0.1 m/s Threshold 0.5 m/s or less Response time 10 sec. or better 3 Wind Direction Range 0360 Accuracy ±5 or better Resolution 1 deg. Threshold 0.5 m/s or better Response Time 10 sec or better Damping Ratio Max 0.25 4 Pressure Sensor Range (With single sensor) Accuracy Resolution Response time Operating Temperatures 600 to 1100 hpa ±0.2 hpa or better 0.1 hpa 10 Sec. or better - 40 C to + 60 C 5 Evaporation Sensor Range 30 to 300mm Accuracy ±1% or better Resolution 1 mm Response time 30 Sec or better Operating temperature -10 to 60 C 5 Relative Humidity Sensor Range 0 to 100% RH Accuracy ±3% or better Resolution 1% Response Time 10 sec. or better Settling Time Max 500 ms Temperature max ±0.05% RH/ C Dependence 6 Rainfall sensor Range 0 to 1023 mm/hr

Accuracy ±5% or better Resolution 0.5 mm 7 Global Radiation Sensor Range 0 to 1500 W/m 2 Accuracy ±5% or better Resolution 5 W/m 2 Data Acquisition and telemetry: Annexure 2 a) The system shall automatically collect the observations from attached sensors, process the same and store them into its memory as per the pre programmed procedure. b) The system shall also send the values of meteorological parameters (user selectable) to a remote display unit or a webserver accessible via the internet. c) The number of analog/digital/ SDI channels in the data logger must be compatible to the sensors being supplied. Atleast four additional analog and digital channels each, extra RS-232, RS-485 and SDI -12 channels must be available to interface other types of sensors. The type and the number of extra channels provided in the data logger must be specified. d) The sensor's signal conditioning unit should be an integral part of the system. e) The system shall have provision to easily include and change the following information as mandatory requirements: o Unique station identification code o Time of observation o Sensor identification. f) The system shall have an integrated microprocessor based data acquisition and storage system having adequate hardware configuration and software support to serve as an interface between sensors and the communication link to perform tasks of data logging, AWS health monitoring and telemetry. g) Providing necessary electrical power to the sensors and conversion of electrical output signals from the sensors into engineering values based on calibration equations stored in the memory. Full compatibility with all types of sensors provided in the packages shall be mandatory. h) Storage of observed data along with time for all the parameters in the memory. Memory capacity to retain at least one year s data is required. Data shall be available even if the power supply to the system has failed (RAM Backup battery) for one year i) The stored data shall be retrievable via serial port to a PC/laptop and a PCMCIA card or any other compact and commercially available solid state memory device. Additionally, a serial port should make the latest data accessible for alternate telemetry devices. j) The system should be stand-alone and all programming functions/set-ups to be carried out through system keypad and display independent of a PC/Laptop.

k )The system should be capable of continuous updating of the values of sensed weather parameters and post processing the instantaneous values into average values over a specified period of time for transmission to the AWS earth station. l) Management of AWS transmitter to optimize the battery consumption. m) The system shall provide a complete health status of the battery, transmitter and other components. n) The health data shall be stored as a log record and shall be capable of being retrieved and displayed when required. o) The system shall have in-built sensor simulation system options to conduct tests on the system for field installation, two-point calibration/re-calibration and maintenance of the sensors. p) The system shall have a weather-proof housing. q) The system shall have self-diagnostic facility and be capable of displaying Station ID/Sensor ID codes and messages on the display panel for general identification of the fault. Facility to monitor these codes and other health status through an external lap top/pc. r) The system shall be provided with a keypad option and at least 16 character display in the front panel. Setup shall be organised in a tree of menus and sub-menus. Protection of setup parameters and data through password should be supported by the system. In addition, the AWS shall support the manual entry of data through keypad and its display. Analog to digital converter: Resolution 16 bit or better Conversion Accuracy ± 1 LSB System clock: Stability Long-term 1 ppm/year or better Stability (Temperature) 3 ppm or better from -40 C to 55 C Other features: Operating Temperature range -10 C to + 55 C Internal Memory 1 MB RAM minimum Battery Backup (internal) Lithium Battery, storage: 2 years Real-Time Clock GPS synchronised Watchdog Timer System Reset upon microprocessor failure Sample Intervals 1 sec. to 24 hr. in 1 second increments (user selectable) Visual display 16 Character or more, alphanumeric LED/LCD to operate in temp. range -10 C to +55 C Power consumption Average over an hour shall be less than 0.5 A at 12V D.C. including that of sensors, GPS and transmitter. Power Supply: Battery Single 12V chargeable maintenance-free battery 65 AH capacity Charge controller Solar panel Internal or External Rated capacity 30W, Open circuit voltage: 21V, Short circuit current 2.4 A