> Port size: /4 (ISO G or NPT), G/ > Working from 0 bar up > Short switching times > Suited for fine vacuum down to,33 x 0 - mbar > For a.c. solenoid systems with integrated rectifier (40... 60 Hz) > Variable valve solenoid combination Technical features Medium: For neutral gaseous and liquid fluids contaminated fluids, upstream installation of a dirt trap is recommended) Operation: Direct solenoid operated poppet valve Operating pressure: 0... 40 bar (0... 580 psi) Orifice:,5... mm Port size: G/4, G/, /4 NPT Flow direction: Fixed Mounting position: Optional, preferably with solenoid on top Ambient/Media temperature: NBR: -5... +80 C (-3... +76 F) FPM: -0...+0 C (+4... +48 F) Water +95 C (+03 F) EDPM: -40... +40 C (-40... +84 F) FFPM: -0...+40 C (+4... +84 F) PTFE: -50...+80 C (-58... +356 F) Depending on solenoid system and seal materials. Air supply must be dry enough to avoid ice formation at temperatures below + C (+35 F). Material: Housing: brass.040 (Ms 58) Seals: NBR other see option selector Inner parts: stainless steel.404 (0 F), brass.040 (Ms 58) Further versions Operating pressure to 50 bar; Seat seals FPM, EPDM, FFPM, PTFE, Rubin; Assembled oil and grease-free Flow conversion: Cv US Gallon/min (water) = l/min (air) x 0,00 Kv m³/h (water) = l/min (air) x 0,000906 Technical data Housing: Brass, Seals: NBR -5... +80 C (-3... +76 F) Symbol Port size Orifice Flow Operating pressure Weight Dimension Solenoid Model (mm) (l/min) (bar) (psi) (kg) (lbs) No. group *) G/4,5 70 0... 40 0... 580 0, 0.46 3B 950000 G/4 0 0... 35 0... 507 0, 0.46 3B 950000 /4 NPT 0 0... 35 0... 507 0, 0.46 3B 950300 G/4 3 00 0... 0 0... 45 0, 0.46 3C 9500300 0 /4 NPT 3 00 0... 0 0... 45 0, 0.46 3C 9503300 G/4 4 350 0... 0... 74 0, 0.46 3D 9500400 /4 NPT 4 350 0... 0... 74 0, 0.46 3D 9503400 G/4 6 550 0... 5 0... 7 0,5 0.55 6D 950600 /4 NPT 6 550 0... 5 0... 7 0,5 0.55 6D 9504600 G/ 700 0... 0... 4 0,8.76 4 6D 950700 0 G/4 00 0... 0 0... 90 0, 0.46 3 3B 9500 G/4 3 60 0... 0 0... 45 0, 0.46 3 3B 95030 *) When ordering please indicate solenoid, voltage and current type (frequency). without notice, the specifications given in this document. (008-50g) 05 Norgren GmbH en 5.4.304.0
Option selector 950x x.. Orifice (mm) Substitute,5 3 3 4 4 6 6 7 Material seat seal Substitute NBR 0 EDPM FPM PTFE only orifice,5... 4 NC 3 FFPM 4 Rubin only orifice... 3 NC 5 Voltage Substitute 4 V d.c. 0400 30 V a.c. 3050 Solenoid Substitute See solenoid table en 5.4.304.0 without notice, the specifications given in this document. (008-50g) 05 Norgren GmbH
Solenoids group 3B, standard voltages Power consumption Rated current Protection class IP/NEMA Ex-Protection (ATEX-Category) Temperature Ambient/ Media Electrical connection Drawing Circuit diagram Model 4 V DC 30 V AC 4 V DC 30 V AC (W) (VA) (ma) (ma) ( C) No. No. 8,0 33 IP65 *) 046 9, 40 IP65 *) 7 306 8,0 33 IP65-9, - 40 IP65 T0 C/T0 C/T30 C Dc T0 C/T0 C/T30 C Dc 6,9-89 - IP66 II G Ex mb IIC T4 Gb II D Ex mb IIIC T0 C Db -0... +60 Special 36-0... +60 Special 6 38-0... +60 Cable length 3 m 5 4 09-8,7-34 IP66 II G Ex mb IIC T4 Gb II D Ex mb IIIC T0 C Db -0... +60 Cable length 3 m 5 7 093 3,9-6 - IP66-5,3-3 IP66 3,9-6 - IP66-5,3-3 IP66 3,9-6 - IP66 5,3 3 IP66 II G Ex eb mb IIC T4/ T6 Gb II G Ex eb mb IIC T4/ T6 Gb M0 x,5 *) 6 4 40 M0 x,5 *) 6 7 4 / NPT *) 7 0 460 / NPT *) 7 46 M0 x,5 *) 7 0 46 M0 x,5 *) 7 463 5,5 8 4x Cl. I, Div., Gr. A - D Cl. II/III, Div., Gr. E - G T3C (60 C) 8 37 5,9 6 4x Cl. I, Div., Gr. A - D Cl. II/III, Div., Gr. E - G T3C (60 C) 8 5 373 Standard voltages (±0%) 4 V d.c., 30 V a.c., other voltages on request. Design according to VDE 0580, EN 5004/5008. 00% duty cycle. *) /cable gland is not scope of delivery, see table»accessories«attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb. Approvals Model Approvals Datasheet ATEX IECEx FM 09x KEMA 0 ATEX 347 X IECEx DEK 3.004X en 7..505 3x, 38x EC-Declaration of Conformity en 7..570 37x, 38x CSA-LR 576-6 en 7..575 4xx KEMA 98 ATEX 445 X IECEx KEM 09.0068X en 7..580 46xx PTB 0 ATEX 085 X IECEx PTB.0094X en 7..585 without notice, the specifications given in this document. (008-50g) 05 Norgren GmbH en 5.4.304.03
Solenoids group 3C, standard voltages Power consumption Rated current Protection class IP/NEMA Ex-Protection (ATEX-Category) Temperature Ambient/ Media Electrical connection Drawing Circuit diagram Model 4 V DC 30 V AC 4 V DC 30 V AC (W) (VA) (ma) (ma) ( C) No. No., 504 IP65 DIN EN 7530-803, *) 000,3 49 IP65, 504 IP65,3 49 IP65 T0 C/T0 C/T30 C Dc T0 C/T0 C/T30 C Dc 0,7 446 IP66 II G Ex mb IIC T4 Gb II D Ex mb IIIC T0 C Db DIN EN 7530-803, *) 6 304-0... +60 Special 37-0... +50 Special 6 39-0... +40 Cable length 3 m 5 4 090,4 54 IP66 II G Ex mb IIC T4 Gb II D Ex mb IIIC T0 C Db -0... +40 Cable length 3 m 5 7 09 8,9 369 IP66 II G Ex eb mb IIC T4/T5 Gb T4: -40... +65 T5: -40... +55-40... +65 M0 x,5 *) 6 4 40 0,0 IP66 II G Ex eb mb IIC T4/T5 Gb T4: -40... +65 T5: -40... +55-40... +65 M0 x,5 *) 6 7 4 8,9 369 IP66 T4: -40... +70 T6: -40... +40-40... +70 / NPT *) 7 0 460 0,0 IP66 T4: -40... +70 T6: -40... +40-40... +70 / NPT *) 7 46 8,9 369 IP66 T4: -40... +70 T6: -40... +40-40... +70 M0 x,5 *) 7 0 46 0,0 IP66 T4: -40... +70 T6: -40... +40-40... +70 M0 x,5 *) 7 463 8,9 369 4x Cl. I, Div., Gr. A - D Cl. II/III, Div., Gr. E - G T3C (60 C) 8 374 9,5 4 4x Cl. I, Div., Gr. A - D Cl. II/III, Div., Gr. E - G T3C (60 C) 8 5 375 Standard voltages (±0%) 4 V d.c., 30 V a.c., other voltages on request. Design according to VDE 0580, EN 5004/5008. 00% duty cycle. *) /cable gland is not scope of delivery, see table»accessories«attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb. Approvals Model Approvals Datasheet ATEX IECEx FM 09x KEMA 0 ATEX 347 X IECEx DEK 3.004X en 7..505 3x, 38x EC-Declaration of Conformity en 7..570 37x, 38x CSA-LR 576-6 en 7..575 4xx KEMA 98 ATEX 445 X IECEx KEM 09.0068X en 7..580 46xx PTB 0 ATEX 085 X IECEx PTB.0094X en 7..585 en 5.4.304.04 without notice, the specifications given in this document. (008-50g) 05 Norgren GmbH
Solenoids group 3D, standard voltages Power consumption Rated current Protection class IP/NEMA Ex-Protection (ATEX-Category) Temperature Ambient/ Media Electrical connection Drawing Circuit diagram Model 4 V DC 30 V AC 4 V DC 30 V AC (W) (VA) (ma) (ma) ( C) No. No. 6,9 703 IP65 *) 3 0700 9,5 75 IP65 *) 4 6 3703,4 475 IP66 5, 66 IP66,4 475 IP66 5, 66 IP66,4 475 IP66 5, 66 IP66 II G Ex eb mb IIC T4/ T5 Gb II G Ex eb mb IIC T4/ T5 Gb M0 x,5 *) 6 4 0 M0 x,5 *) 6 7 / NPT *) 7 0 4630 / NPT *) 7 463 M0 x,5 *) 7 0 463 M0 x,5 *) 7 4633 3,6 567 4x Cl. I, Div., Gr. A - D Cl. II/III, Div., Gr. E - G T3C (60 C) 8 376 5,7 68 4x Cl. I, Div., Gr. A - D Cl. II/III, Div., Gr. E - G T3C (60 C) 8 5 377 Standard voltages (±0%) 4 V d.c., 30 V a.c., other voltages on request. Design according to VDE 0580, EN 5004/5008. 00% duty cycle. *) /cable gland is not scope of delivery, see table»accessories«attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb. Approvals Model Approvals Datasheet ATEX IECEx FM 3x, 38x EC-Declaration of Conformity en 7..570 37x, 38x CSA-LR 576-6 en 7..575 4xx KEMA 98 ATEX 445 X IECEx KEM 09.0068X en 7..580 46xx PTB 0 ATEX 085 X IECEx PTB.0094X en 7..585 without notice, the specifications given in this document. (008-50g) 05 Norgren GmbH en 5.4.304.05
Solenoids group 6D, standard voltages Power consumption Rated current Protection class IP/NEMA Ex-Protection (ATEX-Category) Temperature Ambient/ Media Electrical connection Drawing Circuit diagram 4 V DC 30 V AC 4 V DC 30 V AC (W) (VA) (ma) (ma) ( C) No. No. 6,9 703 IP65 *) 3 0800 Model 7,3 75 IP65 *) 4 6 3803 6,9 703 IP65 7,3 75 IP65,4 475 IP66 T0 C/T0 C/T30 C Dc T0 C/T0 C/T30 C Dc II G Ex eb mb IIC T4/T5 Gb -0... +55 Special -0... +45 Special 3 387 4 6 389 M0 x,5 *) 6 4 480 5, 66 IP66 II G Ex eb mb IIC T4/T5 Gb M0 x,5 *) 6 7 48,4 475 IP66 / NPT *) 7 0 4680 5, 66 IP66 / NPT *) 7 468,4 475 IP66 M0 x,5 *) 7 0 468-5, 66 IP66 M0 x,5 *) 7 4683 3,6 567 4x Cl. I, Div., Gr. A - D Cl. II/III, Div., Gr. E - G T3C (60 C) 5,7 68 4x Cl. I, Div., Gr. A - D Cl. II/III, Div., Gr. E - G T3C (60 C) 8 386 8 5 387 Standard voltages (±0%) 4 V d.c., 30 V a.c., other voltages on request. Design according to VDE 0580, EN 5004/5008. 00% duty cycle. *) /cable gland is not scope of delivery, see table»accessories«attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb. Approvals Model Approvals Datasheet ATEX IECEx FM 37x, 38x CSA-LR 576-6 en 7..575 4xx KEMA 98 ATEX 445 X IECEx KEM 09.0068X en 7..580 46xx PTB 0 ATEX 085 X IECEx PTB.0094X en 7..585 en 5.4.304.06 without notice, the specifications given in this document. (008-50g) 05 Norgren GmbH
Partnumbers for international approval Land/Approval Coil/Code 09x 3x/38x 37x/38x 4xx 46xx 48xx Europa/ATEX Standard x x x x x International/IECEx Standard x x x x x China/NEPSI -0 x x Brasilien/INMETRO -0 x x Korea/KOSHA -03 x x x Russland, Kasachstan & Weißrussland/TR-CU 0-04 x x x x Indien/CCOE Standard x x Taiwan/ITRI Standard x x USA/FM Standard x Kanada/CSA Standard x Example: 00000004700400-04 (Coil: 470; Voltage: 4V DC; Approval: TR-CU 0) Accessories Electrical connection Cable gland Protection class Ex e, Ex d (ATEX), Nickel plated brass/ Stainless steel Page 7 Ambient For solenoid Thread Cable Ø (mm) Material Protection class (ATEX) temperatur limitation *) Model 4xx M0 x,5 7,0,0 Plastic II G Ex e / II D Ex t See table 0589735 4xx M0 x,5 0,0 4,0 Plastic II G Ex e / II D Ex t See table 0589736 4xx M0 x,5 6,0,0 Plastic II G Ex e / II D Ex t See table 0589737 46xx M0 x,5 5,0 8,0 Nickel plated brass II G Ex e / II D Ex t - 058889 46xx M0 x,5 0,0 4,0 Nickel plated brass II G Ex d / II D Ex t - 058885 46xx / NPT 7,5,9 Nickel plated brass II G Ex d / II D Ex t - 058895 46xx, 48xx M0 x,5 9,0 3,0 Stainless steel.457 II G Ex e / II D Ex t - 0589385 46xx, 48xx M0 x,5 7,0,0 Stainless steel.4404 II G Ex d / II D Ex t - 0589395 46xx, 48xx M0 x,5 0,0 4,0 Stainless steel.4404 II G Ex d / II D Ex t - 0589387 *) The limitation of the temperature range to the mentioned range is due to the self-heating of the solenoid. For Ambient temperatur limitation solenoid 4xx solenoid 0589735 & 0589736 *) 0589737 4x/46x T4 & Dust Ex: -35 C + 80 C T4 & Dust Ex: -40 C + 65 C T6: -35 C + 55 C T6: -40 C + 55 C 4x/47x T4 & Dust Ex: -35 C +65 C T4 & Dust Ex: -40 C + 6 C T5: -35 C + 55 C T5: -40 C + 55 C x/48x T4 & Dust Ex: -35 C +50 C T4 & Dust Ex: -40 C +50 C T5: -35 C +40 C T5: -40 C +40 C *) Tested for the lower level of mechanical risk (4 joule), an additional protection against impacts might be needed. DIN EN 7530-803 057075 () without notice, the specifications given in this document. (008-50g) 05 Norgren GmbH en 5.4.304.07
8 8 Dimensions in mm Projection/First angle 75,5 8 9 ~ 0 8 7 9 9,5 ~ 0 8,5 9,5 36 36 G /4 Drawings - Valve 6 3 4 8 8 7 9 9,5 46,5 7 9 9, ~ 0 ~ 86 ~ 40 75 G / ~ 5,4 ~ 0 36 M4 x 6 mm deep en 5.4.304.08 without notice, the specifications given in this document. (008-50g) 05 Norgren GmbH
Drawings - Solenoid Weight: 0,5 kg Weight: 0,6 kg Dimensions in mm Projection/First angle 38 7 46 79 3 4 53,5 49 86,5 5 63,5 59 96,5 34 7 M6 x,5 8 7 5 Weight: 0,5 kg 6 07 33 4 8,5 89 54,5 34 48 M6 x,5 8 9,5 4,5 5,5 M6 x,5 8 7 M6 x,5 9,5 8 8 8 Weight: 0,7 kg Weight: 0,3 kg 7 Weight: 0,4 kg 64,5 7 0 4 63,5 9,5 73 can be indexed by 4 x 90 ø 6 or 3 spacer tube) without notice, the specifications given in this document. (008-50g) 05 Norgren GmbH en 5.4.304.09
7 Weight: 0,8 kg 70,5 8 Weight: 0,5 kg Dimensions in mm Projection/First angle / NPT 0 53 4,5 4,5 59 56 63 84 33,5 6 4 Circuit diagrams 9 ø 6 or 3 spacer tube) 3 M0 x,5 or / NPT 4 Flying leads AWG 8 (460 mm long) 4 5 6 7 0 T T Cable gland C B A D C B 058895 only EN - Englisch Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features/data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI Precision Engineering, Norgren GmbH. A D A B C ø D Model M0 x,5 0 40 7,0...,0 4 0589735 M0 x,5 0 0,0... 4,0 7 0589736 M0 x,5 0 40 6,0...,0 4 0589737 M0 x,5 9 36 5,0... 8,0 058889 M0 x,5 4 39 0,0... 4,0 4 058885 / NPT 5 58 7,5...,9 4 058895 M0 x,5 6,5 7,5 9,0... 3,0 0589385 M0 x,5 4 39 7,0...,0 4 0589395 M0 x,5 0 34 0,0... 4,0 4 0589387 Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. en 5.4.304.00 without notice, the specifications given in this document. (008-50g) 05 Norgren GmbH