KTC. Preset Counter/ Timer. Programmable Type. Model Number Legend SALIENT FEATURES. Sensing. Digital Panel Meters

Similar documents
DMW. Digital Weighing Meter. Model Number Legend SALIENT FEATURES. Sensing

FMF. Miniature Photoelectric Sensor. Flat Type. Model Number Legend SALIENT FEATURES. Sensing. Photoelectric

4. Sensing Distance. 2: 2 mm. 4: 4 mm 8: 8 mm 15: 15 mm 16: 16 mm 20: 20 mm

Monitoring Relays can be used to monitor 3-phase power supplies with 3 or 4 wires simply by changing DIP switch settings.

02/11/2015

Model Number Structure

Timer, Counter & Display

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Inductive Proximity Sensor

PRCMT18-5DO PRCMT18-5DC PRCMT18-5DO-I PRCMT18-5DC-I

Chapter. In This Chapter...

Self-Powered Counters H7EC

Model Number Structure

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)

Amplifiers, Counters, Timers & Controls

Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range.

Counting On Your Process Preset Counters

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)

Tachometers TC-4B-V TC-6A-V Electronic cam-operated switching devices FC-21-V... 50

Thread length (overall length) material

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Combine Relays and P7TF Block Bases to match your application requirements. Use the table below to configure Relay Blocks.

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

Digital Counter H7CZ. Easy to Use and Easy to Read. Features. Basic Features Better Readability Character Height of 10 mm with a Wide Viewing Angle.

E2K-C25MY1 E2K-C25MY2

FEATURES DESCRIPTION FEATURES

PRD/PRDW Series. Long Distance Type

H7BX CSM_H7BX_DS_E_4_4

FEATURES DESCRIPTION SPECIFICATIONS

Product Discontinuation Notices. Discontinuation Notice of Compact proximity sensor TL-M series (for china area only)

Chip Immune Inductive Prox E2EZ

Displays Transducers. Displays and transducers

02/11/2015

H3CR-F H3CR-F8 H3CR-F-300 H3CR-F8-300

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Programmable Relay ZEN V2 Units

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Solid-State Counter/Timer

KCN-S/KCN-W. Merits. Single/Dual Preset Counters for Addition and Subtraction. Electronic. Counters

SENSORS SR23. Fork Sensors - SR23. High efficiency fork sensor for booklet and multilayer labels detection APPLICATIONS

-ment Ambient humidity 35 to 95%RH, Storage :35 to 95%RH

Smart Sensors (with Ultra-High-Speed CCD Camera) ZFV Series

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Bulletin 700-SH Solid-State Relays. Overview/Product Selection. Bulletin 700-SH. Product Selection

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

2. Actuator B: Ball type P: Pin type F: Flat type

H3CA-8H-AC/100/110/120

CPU Units with 20 I/O points

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

Solid-state Counter. Power supply Output No voltage input (short/open circuit) Voltage input (high/low voltage) 30 cps 1 kcps 30 cps 1 kcps AC

Terminal block 2 A 5 X 3. Specification

Model Number Structure

Despite its ultra-slim design, a CPM2C system can provide up to 192 I/O points!

EE-SPX74/84. Ordering Information. Compact Sensor for High-Density Mounting with Easy Snap-In Connector. H Connector features a built-in safety

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features

TIMERS FOR ALL APPLICATIONS

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

Process displays For current and voltage

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Appearance Connection method Sensing distance 1 E3MC-A11 E3MC-A41. 60±10 mm 4 E3MC-MA11 E3MC-MA41

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

Suitable for detecting transparent films or transparent bottles

Inductive Proximity Sensor

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm

LASER. Laser Displacement Transducer. Series LAH-G1. Key-Features:

E2K-X4ME1 2M E2K-X4ME2 2M

Zelio Count - Counters RC87610

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Optimum sensing capability for LCD manufacturing

KCH-B KCH-B. Merits. Application examples. Counters for Display of High-speed Addition and Subtraction. Counters. switches to write settings

G9SX-LM. Low-speed Monitoring Unit. Low-speed Monitoring Function Ensures Safety for Maintenance Work. Model Number Structure.

BWPK Series. Picking sensor. Features. Specifications

Item SM35-J-TA22 SM43-J-TA22 SM70-J-TA22

Samba PLC+HMI SM35-J-RA22

M4Y/M4W/M5W/M4M Series

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

H7ER H7ER-V H7ER-V1 H7ER-V2 H7ER-V3

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

Product Description. Contents. Fusion Series. New Information December 2003

EtherCAT Remote I/O Terminal GX series

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features

Model Number Structure

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs

Operation mode. Output configuration. Relay DC SSR. Light-ON Dark-ON (switch selectable) Relay DC SSR. Relay DC SSR

DIN 48 SIZE DIGITAL TIMER. Compact, Easy-to-read, Easy-to-use... A digital timer made to meet the market s needs.

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Rotary Encoder. Output configuration Open collector Voltage Line driver (see note 3)

Solid-state Timers H3DK

02/11/2015

MICREX-SX Series Renewal Tool Announcement of Release of MICREX-F Size I/O Module

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

Syr-line TMR48D Digital Timer

Syr-line TMR48D Digital Timer

ZEN V2 Units. Features. Programmable Relay. Ph: Fax: Website:

E2Q4 Square Proximity Sensor

Transcription:

Preset Counter/ Timer Programmable Type Model Number Legend SALIENT FEATURES 6 Digits PV, SV Universal Input Dual alarm output MODBUS via RS-485 High Speed - 10 KCPS Multiple output modes Batch Counting, Prescale 1 2 3 4 1. Series 2. Size S: 48 x 48 mm DIN W: 96 x 48 mm DIN M: 72 x 72 mm DIN 3. Output Type R: Relay Output M: Relay + RS-485 Output 4. Power Supply 24DC: 24V DC 230AD: 230V AC/ DC #. Accessories included Panel Mounting Kit : 1 Set Example: -SM-230AD Series - 48*48mm Din Size, 2 Relay Output type with RS-485 Communication - 110-230V AC/ DC Power Supply NOTE: Contact us for models not shown in catalogue. 01

Product Highlights 6 Digit LED display! High- brightness six digit PV & SV LED display in both -S & -W. Universal Input The accepts both No-voltage (NPN) input and voltage (PNP) input. The input logic selection can be done directly through the front panel keys. Batch Counting Batch Counting function is provided in both timer and counter modes. Batch reset using external trigger is enabled. Also Power-off hold function built in the series enables the counter to retain the state of the output value even if power is interupted. COUNTING MODE Batch alarm output when counting quantity is equal to the batch setting value. When batch control output is used, the time interval must be larger than 10ms. TIMING MODE Batch alarm output when the time quantity is equal to or greater than the batch time setting value. BATCH OUTPUT Batch alarm output is ON, until batch reset signal is applied externally. Batch output is held even if power is reset. Prescale Function The series has built in pre-scale function capability. Prescale function is used in places where multiple input pulses need to be combined as one. Application Pulse number P is a number of pulse created by rotary encoder, L is the measured length. Prescale value equals L divides P. π x Diameter of the roller (D) Prescale Value = Pulse numbers per 1 revolution of the encoder 3.1416 x 22 = 1000 = 0.069 mm/ pulse. Set the prescale value at 0.069 in the settings. High Speed input The series counter accepts high speed pulse input of upto 10KCPS. Dual Function The series can function as Timer/ Counter. The same can be set and changed using the front panel keys. Multiple Output Modes Multiple output modes are provided in the series. One-shot output, Hold output and Simultaneous output types are provided. RS-485 Ouptut The provides multiple output options in one compact package. Relay Alarm Output & RS-485 with read and write functions are provided. The diameter of the roller connected to the rotary encoder is 22mm The pulse number per revolution of the encoder is 1000 02

Ratings and Specifications Output Type Relay Output Relay + RS-485 Output 48 x 48 mm -SR-24DC -SR-230AD -SM-24DC -SM-230AD Models Power Supply 96 x 48 mm -WR-24DC -WR-230AD -WM-24DC -WM-230AD 72 x 72 mm -MR-24DC -MR-230AD -MM-24DC -MM-230AD 24 VDC 100-240 VAC/ DC 24 VDC 100-240 VAC/ DC Ripple ±10% (FS) Power Consumption Display Input Voltage Input No- voltage Input 35mA at 220 VAC Dual Line 6 digit LED (PV- Red; SV- Green) Input impedance 5.4KΩ; H- 5~30VDC, L~2VDC Short- circuit impedance 1KΩ Residual Voltage max. 2VDC Min. Signal Width INA, INHIBIT, RESET, BATCH, RESET selectable 1 or 20ms Max. Counting Speed Timer 1, 30 Hz, 1, 5, 10 KHz (selectable) max. ±0.01% ; ±0.05 secomd Data Retention 10 Years Auxilary Voltage Output 12 VDC, 100mA One- shot Output Output Type Control Output Specification 10/ 50/ 100/ 200/ 500/ 1000/ 2000/ 5000 ms 2 Relay 2 Relay + RS-485 250 VAC, 3 A (Resis ve Load) Contact Life max. 100,000 mes (NO: 250 VAC, 3A; NC: 25- VAC, 2A) Dielectric Strength Dielectric Interferance (AC Power) min. 100MΩ at 500 VDC At power terminals 2000 VAC, 50Hz, 1 min ±2kV Square- wave generator interference (width of pulse:1 μs Vibration Resistance Shock Resistance 0.75mm amplitude, 10-55 Hz in X, Y, Z direc ons for 10 minutes ll destruc on 10 G (X, Y, Z in each direc on for three mes) Ambient Ambient Humidity Protection Class Opera on: -10 ~ 50 C; Storage: -25 ~ 65 C (non- freezing; non- condensing) Opera on: 45 ~ 80% RH; Storage: 35 ~ 85% RH (non- condensing) IP20, Front panel IP65 Weight 48 x 48: 149 g; 96 x 48: 159 g; 72 x 72: 253 g Material Front Panel: PU Housing: ABS or Equiv. Note: Configuration options differ for 48 x 48mm, 48 x 96mm & 72 x 72mm. 4 front panel keys are available in 48 x 48mm model; 6 front panel keys are available in 48 x 96mm & 72 x 72mm models. Start-up time of minimum 3 seconds are to be accounted for during power on. IP 65 rating for front panel is valid only when a panel washer is used between the bezel and panel surface. 03

OUT 1 OUT 2 PS 1 PS 2 LOCK Dimension Drawing -S _- _ 97.5 i Panel Cut-out -W _- _ 109 96 COUNTER / TIMER OUT 1 OUT 2 BA.O PS 1 PS 2 LOCK BA.S -W i Panel Cut-out 48 COUNTER / TIMER MD -S RST MD BAT 48 RST 45.5 +0.5 48 45.5 +0.5 90 +0.5 3 3 i Panel Adapter 45 +0.5 94.5 97.5 94.5 Terminal Block 45 Terminal Block 44.5 All dimensions are in mm 04

Dimension Drawing -M _- _ 85 97.5 72 TIMER / COUNTER 3 94.5 Terminal Block PS1 PS2 BA.S 72 67 LOCK OUT1 OUT2 BA.O CNT TMR RST BAT MD -M i Panel Cut-out 67.5 +0.5 67.5 +0.5 All dimensions are in mm Component Names and Function -S Output 1 ON Output 2 ON Keypad Lock ON Output 1 Setting Output 2 Setting Mode/ Function Process Value Set Value Reset Parameter/ Value Change 05

Component Names and Function -W Process Value Output 1 ON Output 2 ON Batch Output ON Output 1 Setting Output 2 Setting Keypad Lock -M Output 1 Setting Output 2 Setting Keypad Lock Output 1 ON Output 2 ON Reset Mode/ Function Connections Input Connection (NPN) Sensor Input Connection (PNP) Sensor 5.4kΩ 5.4kΩ 5.4kΩ Mode/ Function Parameter/ Value Change Reset Set Value Process Value Set Value Counter Mode ON Timer Mode ON Batch Output ON Parameter/ Value Change 06

Connections Output Connection Relay Output SSR Output Load Load Power * Load Load Power (DC) Note - * Use proper load and power for load not to exceed ON/OFF capacity (30VDC max.; 100mA max.) of solid state output. Be sure not to apply reverse polarity to power. When using inductive load, a surge absorber (diode, varistor etc.,) must be connected between both sides of the load. Terminal Connections -S -M -W Cat. No. -C12 Exclusively Represented by: Intech Systems Chennai Pvt Ltd S-2, Guindy Industrial Estate Chennai - 600 032. Ph: 4353 8888 Email: info@intechchennai.com www.inno.sg INNO, Rights Reserved In the interest of continious product improvement specifications are subject to change without notice 07