DICOM Conformance Statement Application: Linkverse DICOM Provider 2.0

Similar documents
Medical Imaging Consultants, Inc.

NumaStore 1.0 DICOM 3.0 Conformance Statement

DICOM Conformance Statement

Conformance Statements for DICOM PaCentric Connect / Traveler

DICOM CONFORMANCE STATEMENT. BrainLAB PatientBrowser 1.0

MediPlus TM PACS&RIS Version 2.6

NumaLink-3.0 DICOM 3.0 Conformance Statement

Patterson DICOM Imaging. DICOM Conformance Statement

DICOM Conformance Statement. CharruaPACS

Version 7 DICOM Conformance Statement. Document Version 3.02, June 2009

PACSMail. DICOM Conformance Statement. Sybermedica Ltd St John s Innovation Centre Cowley Road Cambridge CB4 0WS

PACSware Migration Toolkit (MDIG)

Version 9 DICOM Conformance Statement. Version 3.05, September 2015

StellarPACS DICOM Conformance Statement. Version 1.3, August 2008 SoftTeam Solutions

Caseaccess 1.0 DICOM Conformance Statement

DICOM 3.0 Conformance Statement

DICOM Conformance Statement. isite PACS 4.1. CREF Nov 23. Philips Healthcare Informatics

VM PACS DICOM Conformance Statement

Inobitec DICOM Server (PACS) Conformance Statement. Version: 1.4.x

Abstract. XrayVision DICOM Conformance Statement. Abstract Abstract

Matrix Server and Client DICOM Conformance Statement

Surgimap. DICOM Conformance Statement. Revision 2.0

STaR. DICOM Conformance Statement. September 2009 Version NO COPIES PERMITTED

DE32-DCM DentalEye 3.2. DICOM conformance statement

Abstract DCV DICOM CONFORMANCE. XrayVision DCV DICOM Conformance Statement. Abstract

Dx Server for Windows NT DICOM 3.0 Conformance Statement

Dx Server for Windows NT DICOM 3.0 Conformance Statement

AVIA (Dx MM) DICOM 3.0 Conformance Statement

Perennity DICOM edition DICOM Conformance Statement

JiveX Web-enabled solutions for medical imagecommunication

SIEMENS. DICOM Conformance Statement

POP-Net Essential DICOM Conformance Statement

DICOM CONFORMANCE STATEMENT. BrainLAB PatXfer 5

Image Display DICOM Conformance Statement EasyViz 7.2

Infinity Medical Soft, Inc ,Higashinaganuma,Inagishi, Tokyo JAPAN

dicom PACS 5 Version 5.2

Punctual Dicom Workstation

ETIAM Nexus. DICOM Conformance Statement.

SYNAPSE 3D Conformance Statement FUJIFILM SYNAPSE 3D V3.0. Conformance Statement. Revision Z45N

ClearCanvas Workstation DICOM Conformance Statement. Document Version: 1.5

DICOM Conformance Statement Product Name HCP DICOM Net Version

AGFA HEALTHCARE DICOM Conformance Statement

Hologic Physician s Viewer 5.0 DICOM Conformance Statement

Technical Publication. DICOM Conformance Statement. DICOM Proxy 4.0. Document Revision 11. May 18, Copyright Brainlab AG

Dx Server for Windows NT DICOM 3.0 Conformance Statement

DICOM Conformance Statement. Version: 2.X

AGFA HEALTHCARE DICOM Conformance Statement

DICOM Conformance Statement DragonflyPACS - Rev. 004 Page 3 / 33

DICOM Conformance Statement for PenFetch

Image Display DICOM Conformance Statement

Perennity AccessBox DICOM Conformance Statement

InstaPACS / InstaRISPACS / InstaViewer (v Release) DICOM Conformance Statement. Meddiff Technologies Pvt. Ltd.

Visbion Limited. DicomConnector 3.7 DICOM Conformance Statement. Issue 3 7 December Public. Visbion Limited

1 Introduction Scope and audience References Acronyms and abbreviations 3. 2 Implementation model... 4

iconnect Cloud Gateway V. 1.2

CoActiv, LLC CoActiv Medical Business Solutions EXAM-PACS Conformance Statement

DICOM Conformance Statement. isite PACS 3.6. CREF Apr Philips Medical Systems Radiology Informatics

Technical Publications

QPC XSCAN32 DICOM 3.0 Conformance Statement Document Version October 2004

WINRAD-32 Teleradiology System Conformance Claim

No. MIIMS0009EA DICOM CONFORMANCE STATEMENT FOR MODEL TFS-3000 (MIIMS0009EA) TOSHIBA CORPORATION 2001 ALL RIGHTS RESERVED

AGFA HEALTHCARE DICOM Conformance Statement

Visbion Limited. Image Viewer 4.1 Dicom Conformance Statement DCS-IV-Iss1. Issue 1 21 March Commercial in Confidence

Philips Medical Systems. Xcelera R1.1L1. Document Number XPR July 2003

CHILI CHILI PACS. Digital Radiology. DICOM Conformance Statement CHILI GmbH, Heidelberg

Carl Zeiss Surgical GmbH

Carl Zeiss Meditec AG

Carl Zeiss Surgical GmbH

Carl Zeiss Meditec AG

DICOM Conformance Statement

DICOM Conformance Statement (DCS) Rev 1.1. Surgimap Nemaris Inc. 475 Park Ave S, 11 th Fl. New York, NY 10016

Integrity Medical Image Import Station

CADstream DICOM Conformance Statement

SonoWin Picture Archiving System

DICOM Conformance Statement

Acuo VNA. DICOM Conformance Statement Version 6.0 March 2018

DICOM Conformance Statement

Philips Medical Systems DICOM Conformance Statement. Inturis Suite R2.2

DICOM Conformance Statement

DICOM Conformance Statement

XPACS DICOM 3.0 Conformance Statement Document Version October 2004

ClearCanvas Workstation DICOM Conformance Statement

Merge iconnect Enterprise Archive V. 9.4

RamSoft. PowerServer. DICOM Conformance Statement

Visbion Limited. DICOM Conformance Statement DicomConnector 4.1 DCS-IA-Iss6. Issue 6 21 March Commercial in Confidence

Mach7 Enterprise Imaging Platform v DICOM Conformance Statement

ImageBroker 4.1. DICOM Conformance Statement V 1.0. As of Copyright medigration GmbH All rights reserved

DICOM 3.0 Conformance Statement. For. DCM v2.93. Revision 1.0 October 23, 2003

DICOM Conformance Statement (DCS) Rev 1.2. Surgimap Nemaris Inc. 475 Park Ave S, 11 th Fl. New York, NY 10016

Digital Lightbox 1.0

Health Engine DICOM Conformance Statement. Internal document number: Date:

1 CONFORMANCE STATEMENT OVERVIEW

DICOM V3.0 Conformance Statement. SenoIris 1SP2

Integrity Medical Image Import Station

DICOM Conformance Statement

Beschreibung Gesamt / Total Description

DICOM Conformance Statement

GEMINI DICOM Conformance Statement 16 Power PET/CT Imaging System Configuration

DICOM Conformance Statement IDS5 7.2, WISE 7.2, ImageServer/s 7.2

ClearCanvas Workstation DICOM Conformance Statement

Transcription:

DICOM Conformance Statement Application: Linkverse DICOM Provider 2.0 Document Version: 1.5 (April 4, 2008) Linkverse S.r.l. Linkverse S.r.l. Viale della Piramide Cestia 1/B 00153 Roma P.IVA/CF 09836921008 REA 1192082

Table of Contents 1 Introduction...3 1.1 About this document...3 1.2 Notes...3 2 Implementation Model...4 2.1 Application Data Flow Diagram...4 2.2 Functional Definition of AEs...5 2.2.1 Functional Definition of DICOM Server AE...5 2.3 Sequencing of Real World Activities...5 3 AE Specification...6 3.1 DICOM Server AE...6 3.1.1 SOP Classes...6 3.1.2 Association Policies...8 3.1.2.1 General...8 3.1.2.2 Number of Associations...8 3.1.2.3 Asynchronous Nature...8 3.1.2.4 Implementation Identifying Information...8 3.1.3 Association Initiation Policy...8 3.1.3.1 Data Query/Retrieve Real-World Activity...9 3.1.3.1.1 Description and Sequencing...9 3.1.3.1.2 Proposed Presentation Contexts...9 3.1.3.1.3 SOP Specific Conformance for SOP Classes...11 3.1.4 Association Acceptance Policy...12 3.1.4.1 Verification Real-World Activity...12 3.1.4.1.1 Description and Sequencing...12 3.1.4.1.2 Accepted Presentation Contexts...12 3.1.4.1.3 SOP Specific Conformance for SOP Classes...12 3.1.4.2 Real-World Activity...12 3.1.4.2.1 Description and Sequencing...12 3.1.4.2.2 Accepted Presentation Contexts...12 3.1.4.2.3 SOP Specific Conformance for SOP Classes...15 3.1.4.3 Data Query/Retrieve Real-World Activity...16 3.1.4.3.1 Description and Sequencing...16 3.1.4.3.2 Accepted Presentation Contexts...17 3.1.4.3.3 SOP Specific Conformance for SOP Classes...17 3.1.4.4 Information Query/Retrieve Real-World Activity...18 3.1.4.4.1 Description and Sequencing...18 3.1.4.4.2 Accepted Presentation Contexts...18 3.1.4.4.3 SOP Specific Conformance for SOP Classes...18 4 Communication Profiles...20 4.1 TCP/IP Stack...20 4.1.1 Physical Media Support...20 5 Configuration...21

1 Introduction Linkverse DICOM Provider is an storage and/or communication software for Medical Imaging related data, which is able to store, search and retrieve data from its archives, using the specifications of the DICOM-3.0 standard protocol (thereafter called DICOM, see 1.1 for more information). Linkverse DICOM Provider represents one of the core elements of the Linkverse Black-Box and Black- products. Thanks to the DICOM compliance Linkverse DICOM Provider is able to communicate with DICOM compatible devices using TCP/IP networks. 1.1 About this document This document provides the DICOM Conformance Statement for the Linkverse DICOM Provider implementation of the DICOM standard. The Conformance Statement is a document which defines which parts of the DICOM standard the software complies to. The DICOM standard has been developed by a joint comitee of ACR (American College of Radiology) and NEMA (National Electrical Manufacturers Association) and can be obtained from: NEMA Publication 2101 L Street, N.W., Suite 300 Washington, DC 20037 USA Phone: +1 202 4578474 Or from the NEMA Medical internet web site: http://medical.nema.org This document will refer to the DICOM standard terms and definitions, and has been composed following the DICOM PS 3.2 2008. 1.2 Notes Please note that this Conformance Statement is not intended to be a DICOM compliance certification, while it is meant to help the integration with other DICOM-enabled products. It is upon the user responsibility that proceeds with the integration to carefully perform the appropriate tests to completely, and not partially, determine the services that successfully work with other packages and then that the product can be considered compliant to the user project specifications. Any evolution from the current version of DICOM standard (DICOM PS 3 2008), may require changes to the current Linkverse DICOM Provider application (and therefore an upgrade of the products that implement it). The conformance with the standard may change as well as the standard specifications change.

2 Implementation Model The Linkverse DICOM Provider application implements the DICOM standard to allow to DICOMenabled devices and/or softwares to send, query and retrieve data from it. 2.1 Application Data Flow Diagram The Linkverse DICOM Provider application provides the following Application Entity (AE): DICOM Server The DICOM Server Application Entity provides the following services: (a) Verification. It allows a remote system to check the communications. AE answers an acknowledge as soon as it receives the verification request. (b). It allows a remote system to send data to it. AE store received data in the local data storage. (c) Query. It allows a remote system to query information about stored data and modality worklists. AE performs search queries on the local data storage and provides results to the remote system. (d) Query/Retrieve. It allows a remote system to query and retrieve stored data. AE locates data in the local data storage and sends it back to a remote system.

Figure 1: Functional Overview 2.2 Functional Definition of AEs 2.2.1 Functional Definition of DICOM Server AE DICOM Server AE provides services through the implementation of the following DIMSE messages: (a) C-ECHO as Service Class Provider, for Verification Real-World Activity; (b) C-STORE as Service Class Provider, for Real-World Activity; (c) C-FIND as Service Class Provider, for Information Query/Retrieve Real-World Activity and Modality Worklist Information Query/Retrieve Real-World Activity; (d) C-MOVE as Service Class Provider with related C-STORE as Service Class User, C-GET as Service Class Provider both for Data Query/Retrieve Real-World Activity. To access services, a regular Association should have been established (see DICOM PS 3.8 2008). 2.3 Sequencing of Real World Activities Not Applicable.

3 AE Specification 3.1 DICOM Server AE 3.1.1 SOP Classes DICOM Server AE provides conformance to the DICOM standard to the following SOP Classes as a Service Class Provider (): SOP Class UID Name SOP Class UID Value Verification 1.2.840.10008.1.1 Computed Radiography Image Digital X Ray Image For Processing X-Ray Radiofluoroscopic Image Digital Mammography X Ray Image For Presentation Digital Mammography X Ray Image For Processing Digital Intra Oral X Ray Image For Presentation Digital Intra Oral X Ray Image For Processing Computed Tomography Image 1.2.840.10008.5.1.4.1.1.1 1.2.840.10008.5.1.4.1.1.1.1 1.2.840.10008.5.1.4.1.1.1.1.1 1.2.840.10008.5.1.4.1.1.1.2 1.2.840.10008.5.1.4.1.1.1.2.1 1.2.840.10008.5.1.4.1.1.1.3 1.2.840.10008.5.1.4.1.1.1.3.1 1.2.840.10008.5.1.4.1.1.2 Magnetic Resonance Image 1.2.840.10008.5.1.4.1.1.4 Enhanced Magnetic Resonance Image Magnetic Resonance Spectroscopy Image Ultrasound Multi-Frame Image (retired) Ultrasound Multi-Frame Image 1.2.840.10008.5.1.4.1.1.4.1 1.2.840.10008.5.1.4.1.1.4.2 1.2.840.10008.5.1.4.1.1.3 1.2.840.10008.5.1.4.1.1.3.1 Ultrasound Image (retired) 1.2.840.10008.5.1.4.1.1.6

SOP Class UID Name SOP Class UID Value Ultrasound Image 1.2.840.10008.5.1.4.1.1.6.1 Secondary Capture Image 1.2.840.10008.5.1.4.1.1.7 Multi-Frame Single Bit Secondary Capture Image Multi-Frame Grayscale Byte Secondary Capture Image Multi-Frame Grayscale Word Secondary Capture Image Multi-Frame True Color Secondary Capture Image 1.2.840.10008.5.1.4.1.1.7.1 1.2.840.10008.5.1.4.1.1.7.2 1.2.840.10008.5.1.4.1.1.7.3 1.2.840.10008.5.1.4.1.1.7.4 X-Ray Angiographic Image 1.2.840.10008.5.1.4.1.1.12.1 X-Ray Radiofluoroscopic Image 1.2.840.10008.5.1.4.1.1.12.2 Nuclear Medicine Image 1.2.840.10008.5.1.4.1.1.20 VL Endoscopic Image 1.2.840.10008. 5.1.4.1.1.77.1.1 VL Microscopic Image 1.2.840.10008. 5.1.4.1.1.77.1.2 VL Slide Coordinates Microscopic Image 1.2.840.10008. 5.1.4.1.1.77.1.3 VL Photographic Image 1.2.840.10008. 5.1.4.1.1.77.1.4 PET Image 1.2.840.10008.5.1.4.1.1.128 RT Image 1.2.840.10008.5.1.4.1.1.481. 1 Patient Root Query/Retrieve Information Model FIND Patient Root Query/Retrieve Information Model MOVE Study Root Query/Retrieve Information Model FIND Study Root Query/Retrieve Information Model MOVE 1.2.840.10008.5.1.4.1.2.1.1 1.2.840.10008.5.1.4.1.2.1.2 1.2.840.10008.5.1.4.1.2.2.1 1.2.840.10008.5.1.4.1.2.2.2

SOP Class UID Name Patient/Study Query/Retrieve Information Model FIND Modality Worklist Information Model - FIND Patient/Study Query/Retrieve Information Model MOVE Patient Root Query/Retrieve Information Model GET Study Root Query/Retrieve Information Model GET Patient/Study Query/Retrieve Information Model GET Grayscale Softcopy Presentation State Color Softcopy Presentation State Pseudo-Color Softcopy Presentation State Blending Softcopy Presentation State SOP Class UID Value 1.2.840.10008.5.1.4.1.2.3.1 1.2.840.10008.5.1.4.31 1.2.840.10008.5.1.4.1.2.3.2 1.2.840.10008.5.1.4.1.2.1.3 1.2.840.10008.5.1.4.1.2.2.3 1.2.840.10008.5.1.4.1.2.3.3 1.2.840.10008.5.1.4.1.1.11.1 1.2.840.10008.5.1.4.1.1.11.2 1.2.840.10008.5.1.4.1.1.11.3 1.2.840.10008.5.1.4.1.1.11.4 Commitment Push Model 1.2.840.10008.1.20.1 Table 1: Supported SOP Classes as 3.1.2 Association Policies 3.1.2.1 General DICOM Server recognizes the following Application Context Names: Application Context Name Application Context UID Standard DICOM Application Context Name 1.2.840.10008.3.1.1.1 Table 2. Supported Application Context PDU size can be negotiated up to 131072 bytes (128 kb). 3.1.2.2 Number of Associations DICOM Server supports number of association limit setup. The maximum number of associations

accepted as configuration depends on the system on which the application runs. 3.1.2.3 Asynchronous Nature DICOM Server doesn't support asynchronous messages. 3.1.2.4 Implementation Identifying Information DICOM Server use the following Implementation Identifying Information: Description Value Implementation Class UID Implementation Version Name 1.3.76.31.10.1.x.y.z where x.y.z is the DICOM library version DICOMPROVIDER_yyyymmdd where yyyymmdd is the release date 3.1.3 Association Initiation Policy Table 3. Implementation Identifying Information DICOM Server initiates an Association when performing a Real-World Activity of Data Query/Retrieve. 3.1.3.1 Data Query/Retrieve Real-World Activity 3.1.3.1.1 Description and Sequencing When a Real-World Data Query/Retrieve operation is performed, a C-MOVE operation (Real- World Data Query) is initiated with the DICOM Server by a remote system. DICOM Server performs the data query embedded in the received C-MOVE Request command. If the query succeeds, it initiates an association to a specified destination AE (which AE Title is provided in the C-MOVE Request command). If the association succeeds, a C-STORE operation (Real-World Data Retrieve) is initiated with the specified destination by the DICOM Server, prepared with data resulting from the successful query. 3.1.3.1.2 Proposed Presentation Contexts During C-STORE operation, DICOM Server will propose presentation contexts according to stored data to be transferred: in particular, Abstract Syntax will be proposed depending on the SOP Class of each object to be sent. The list of possible proposed Presentation Contexts is reported in the following table: Abstract Syntax Name Abstract Syntax UID Transfer Syntax Role Extended Negotiation Computed Radiography Image Digital X Ray Image For Processing 1.2.840.10008.5.1.4.1.1.1 See Table 5 SCU 1.2.840.10008.5.1.4.1.1.1.1 See Table 5 SCU

Abstract Syntax Name Abstract Syntax UID Transfer Syntax Role Extended Negotiation X-Ray Radiofluoroscopic Image Digital Mammography X Ray Image For Presentation Digital Mammography X Ray Image For Processing Digital Intra Oral X Ray Image For Presentation Digital Intra Oral X Ray Image For Processing Computed Tomography Image Magnetic Resonance Image Enhanced Magnetic Resonance Image Magnetic Resonance Spectroscopy Image Ultrasound Multi-Frame Image (retired) Ultrasound Multi-Frame Image Ultrasound Image (retired) Ultrasound Image Secondary Capture Image 1.2.840.10008.5.1.4.1.1.1.1.1 See Table 5 SCU 1.2.840.10008.5.1.4.1.1.1.2 See Table 5 SCU 1.2.840.10008.5.1.4.1.1.1.2.1 See Table 5 SCU 1.2.840.10008.5.1.4.1.1.1.3 See Table 5 SCU 1.2.840.10008.5.1.4.1.1.1.3.1 See Table 5 SCU 1.2.840.10008.5.1.4.1.1.2 See Table 5 SCU 1.2.840.10008.5.1.4.1.1.4 See Table 5 SCU 1.2.840.10008.5.1.4.1.1.4.1 See Table 5 SCU 1.2.840.10008.5.1.4.1.1.4.2 See Table 5 SCU 1.2.840.10008.5.1.4.1.1.3 See Table 5 SCU 1.2.840.10008.5.1.4.1.1.3.1 See Table 5 SCU 1.2.840.10008.5.1.4.1.1.6 See Table 5 SCU 1.2.840.10008.5.1.4.1.1.6.1 See Table 5 SCU 1.2.840.10008.5.1.4.1.1.7 See Table 5 SCU Multi-Frame Single Bit Secondary Capture Image 1.2.840.10008.5.1.4.1.1.7.1 See Table 5 SCU

Abstract Syntax Name Abstract Syntax UID Transfer Syntax Role Extended Negotiation Multi-Frame Grayscale Byte Secondary Capture Image Multi-Frame Grayscale Word Secondary Capture Image Multi-Frame True Color Secondary Capture Image X-Ray Angiographic Image X-Ray Radiofluoroscopic Image Nuclear Medicine Image 1.2.840.10008.5.1.4.1.1.7.2 See Table 5 SCU 1.2.840.10008.5.1.4.1.1.7.3 See Table 5 SCU 1.2.840.10008.5.1.4.1.1.7.4 See Table 5 SCU 1.2.840.10008.5.1.4.1.1.12.1 See Table 5 SCU 1.2.840.10008.5.1.4.1.1.12.2 See Table 5 SCU 1.2.840.10008.5.1.4.1.1.20 See Table 5 SCU VL Endoscopic Image 1.2.840.10008. 5.1.4.1.1.77.1.1 See Table 5 SCU VL Microscopic Image 1.2.840.10008. 5.1.4.1.1.77.1.2 See Table 5 SCU VL Slide Coordinates Microscopic Image 1.2.840.10008. 5.1.4.1.1.77.1.3 See Table 5 SCU VL Photographic Image 1.2.840.10008. 5.1.4.1.1.77.1.4 See Table 5 SCU PET Image 1.2.840.10008.5.1.4.1.1.128 See Table 5 SCU RT Image 1.2.840.10008.5.1.4.1.1.481.1 See Table 5 SCU Grayscale Softcopy Presentation State Color Softcopy Presentation State Pseudo-Color Softcopy Presentation State 1.2.840.10008.5.1.4.1.1.11.1 See Table 5 SCU 1.2.840.10008.5.1.4.1.1.11.2 See Table 5 SCU 1.2.840.10008.5.1.4.1.1.11.3 See Table 5 SCU

Abstract Syntax Name Abstract Syntax UID Transfer Syntax Role Extended Negotiation Blending Softcopy Presentation State 1.2.840.10008.5.1.4.1.1.11.4 See Table 5 SCU Table 4. Proposed Presentation Contexts for Data Query/Retrieve Real-World Activity For each Abstract Syntax, all transfer syntaxes from the following table are proposed: Transfer Syntax Name Transfer Syntax UID Implicit VR Little Endian 1.2.840.10008.1.2 Explicit VR Little Endian 1.2.840.10008.1.2.1 Explicit VR Big Endian 1.2.840.10008.1.2.2 JPEG Lossless Non-Hierarchical* 1.2.840.10008.1.2.4.57 JPEG Lossless Non-Hierarchical 1st order prediction* 1.2.840.10008.1.2.4.70 Table 5. DICOM Server Supported Transfer Syntaxes (* Where applicable) 3.1.3.1.3 SOP Specific Conformance for SOP Classes During a Data Query/Retrieve Real-World Activity, C-STORE command responses are handled as follows: Service Status Further Meaning Error Code Behavior Success Commited storage operation has been successfully completed 0000 Log success for SOP Instance UID If a next SOP Instance UID has to be processed: Report progress within the C-MOVE operation Proceed with next SOP Instance Otherwise: Report success within the C-MOVE operation Exit association Other Error / Warning / Other events Not 0000 Log error for SOP Instance UID Report error to C-MOVE command Exit association Table 6. C-STORE Response Status Handling for Data Query/Retrieve Real-World Activity

No extended negotiation is supported. If the C-STORE operation cannot be completed (e.g. the association is aborted before the end of the transaction), the C-MOVE operation will end and fail. There is no timeout implementation in such process: C-MOVE operation doesn't end until an association is unexpectedly released or aborted (or the connection is dropped), or the procedure terminates correctly. 3.1.4 Association Acceptance Policy DICOM Server doesn't have any application limit for association acceptance. Access restrictions can be set through the Operating System or through the binding interface specification during the configuration process. 3.1.4.1 Verification Real-World Activity 3.1.4.1.1 Description and Sequencing When a Real-World Verification Activity is performed, a C-ECHO operation is performed. 3.1.4.1.2 Accepted Presentation Contexts Any Presentation Context of the following table will be accepted: Abstract Syntax Name Abstract Syntax UID Transfer Syntax Role Extended Negotiation Verification 1.2.840.10008.1.1 Any Transfer Syntax of Table 5 Table 7. Verification Real-World Activity Accepted Presentation Contexts 3.1.4.1.3 SOP Specific Conformance for SOP Classes DICOM Server provides conformance to the DICOM Verification Class as an for Verification SOP Class (1.2.840.10008.1.1). 3.1.4.2 Real-World Activity 3.1.4.2.1 Description and Sequencing When a Real-World Activity is performed, a C-STORE operation is performed. 3.1.4.2.2 Accepted Presentation Contexts Any Presentation Context of the following table will be accepted: Abstract Syntax Name Abstract Syntax UID Transfer Syntax Role Extended Negotiation Computed Radiography Image 1.2.840.10008.5.1.4.1.1.1 Any Transfer

Abstract Syntax Name Abstract Syntax UID Transfer Syntax Role Extended Negotiation Digital X Ray Image For Processing 1.2.840.10008.5.1.4.1.1.1.1 Any Transfer X-Ray Radiofluoroscopic Image 1.2.840.10008.5.1.4.1.1.1.1.1 Any Transfer Digital Mammography X Ray Image For Presentation 1.2.840.10008.5.1.4.1.1.1.2 Any Transfer Digital Mammography X Ray Image For Processing 1.2.840.10008.5.1.4.1.1.1.2.1 Any Transfer Digital Intra Oral X Ray Image For Presentation 1.2.840.10008.5.1.4.1.1.1.3 Any Transfer Digital Intra Oral X Ray Image For Processing 1.2.840.10008.5.1.4.1.1.1.3.1 Any Transfer Computed Tomography Image 1.2.840.10008.5.1.4.1.1.2 Any Transfer Magnetic Resonance Image 1.2.840.10008.5.1.4.1.1.4 Any Transfer Enhanced Magnetic Resonance Image 1.2.840.10008.5.1.4.1.1.4.1 Any Transfer Magnetic Resonance Spectroscopy Image 1.2.840.10008.5.1.4.1.1.4.2 Any Transfer Ultrasound Multi-Frame Image (retired) 1.2.840.10008.5.1.4.1.1.3 Any Transfer Ultrasound Multi-Frame Image 1.2.840.10008.5.1.4.1.1.3.1 Any Transfer Ultrasound Image (retired) 1.2.840.10008.5.1.4.1.1.6 Any Transfer Ultrasound Image 1.2.840.10008.5.1.4.1.1.6.1 Any Transfer Secondary Capture Image 1.2.840.10008.5.1.4.1.1.7 Any Transfer

Abstract Syntax Name Abstract Syntax UID Transfer Syntax Role Extended Negotiation Multi-Frame Single Bit Secondary Capture Image 1.2.840.10008.5.1.4.1.1.7.1 Any Transfer Multi-Frame Grayscale Byte Secondary Capture Image 1.2.840.10008.5.1.4.1.1.7.2 Any Transfer Multi-Frame Grayscale Word Secondary Capture Image 1.2.840.10008.5.1.4.1.1.7.3 Any Transfer Multi-Frame True Color Secondary Capture Image 1.2.840.10008.5.1.4.1.1.7.4 Any Transfer X-Ray Angiographic Image 1.2.840.10008.5.1.4.1.1.12.1 Any Transfer X-Ray Radiofluoroscopic Image 1.2.840.10008.5.1.4.1.1.12.2 Any Transfer Nuclear Medicine Image 1.2.840.10008.5.1.4.1.1.20 Any Transfer VL Endoscopic Image 1.2.840.10008. 5.1.4.1.1.77.1.1 Any Transfer VL Microscopic Image 1.2.840.10008. 5.1.4.1.1.77.1.2 Any Transfer VL Slide Coordinates Microscopic Image 1.2.840.10008. 5.1.4.1.1.77.1.3 Any Transfer VL Photographic Image 1.2.840.10008. 5.1.4.1.1.77.1.4 Any Transfer PET Image 1.2.840.10008.5.1.4.1.1.128 Any Transfer RT Image 1.2.840.10008.5.1.4.1.1.481.1 Any Transfer Grayscale Softcopy Presentation State 1.2.840.10008.5.1.4.1.1.11.1 See Table 5

Abstract Syntax Name Abstract Syntax UID Transfer Syntax Role Extended Negotiation Color Softcopy Presentation State Pseudo-Color Softcopy Presentation State Blending Softcopy Presentation State 1.2.840.10008.5.1.4.1.1.11.2 See Table 5 1.2.840.10008.5.1.4.1.1.11.3 See Table 5 1.2.840.10008.5.1.4.1.1.11.4 See Table 5 Table 7. Real-World Activity Accepted Presentation Contexts 3.1.4.2.3 SOP Specific Conformance for SOP Classes During a Real-World Activity, DICOM Server returns the Status in C-STORE Responses with the following policy: Service Status Further Meaning Error Code Reason Success Success 0000 Data has been successfully stored and indexed Failure Failure 0110 Error found in data storage or indexing Table 8. Real-World Activity C-STORE Response Status policy DICOM Server gives a Level 2 Conformance to the following SOP Classes: SOP Class Name Computed Radiography Image Digital X Ray Image For Processing X-Ray Radiofluoroscopic Image Digital Mammography X Ray Image For Presentation Digital Mammography X Ray Image For Processing Digital Intra Oral X Ray Image For Presentation SOP Class UID 1.2.840.10008.5.1.4.1.1.1 1.2.840.10008.5.1.4.1.1.1.1 1.2.840.10008.5.1.4.1.1.1.1.1 1.2.840.10008.5.1.4.1.1.1.2 1.2.840.10008.5.1.4.1.1.1.2.1 1.2.840.10008.5.1.4.1.1.1.3

SOP Class Name Digital Intra Oral X Ray Image For Processing Computed Tomography Image SOP Class UID 1.2.840.10008.5.1.4.1.1.1.3.1 1.2.840.10008.5.1.4.1.1.2 Magnetic Resonance Image 1.2.840.10008.5.1.4.1.1.4 Enhanced Magnetic Resonance Image Magnetic Resonance Spectroscopy Image Ultrasound Multi-Frame Image (retired) Ultrasound Multi-Frame Image 1.2.840.10008.5.1.4.1.1.4.1 1.2.840.10008.5.1.4.1.1.4.2 1.2.840.10008.5.1.4.1.1.3 1.2.840.10008.5.1.4.1.1.3.1 Ultrasound Image (retired) 1.2.840.10008.5.1.4.1.1.6 Ultrasound Image 1.2.840.10008.5.1.4.1.1.6.1 Secondary Capture Image 1.2.840.10008.5.1.4.1.1.7 Multi-Frame Single Bit Secondary Capture Image Multi-Frame Grayscale Byte Secondary Capture Image Multi-Frame Grayscale Word Secondary Capture Image Multi-Frame True Color Secondary Capture Image 1.2.840.10008.5.1.4.1.1.7.1 1.2.840.10008.5.1.4.1.1.7.2 1.2.840.10008.5.1.4.1.1.7.3 1.2.840.10008.5.1.4.1.1.7.4 X-Ray Angiographic Image 1.2.840.10008.5.1.4.1.1.12.1 X-Ray Radiofluoroscopic Image 1.2.840.10008.5.1.4.1.1.12.2 Nuclear Medicine Image 1.2.840.10008.5.1.4.1.1.20 VL Endoscopic Image 1.2.840.10008. 5.1.4.1.1.77.1.1 VL Microscopic Image 1.2.840.10008. 5.1.4.1.1.77.1.2 VL Slide Coordinates Microscopic Image 1.2.840.10008. 5.1.4.1.1.77.1.3 VL Photographic Image 1.2.840.10008. 5.1.4.1.1.77.1.4

SOP Class Name SOP Class UID PET Image 1.2.840.10008.5.1.4.1.1.128 RT Image 1.2.840.10008.5.1.4.1.1.481.1 Grayscale Softcopy Presentation State Color Softcopy Presentation State Pseudo-Color Softcopy Presentation State Blending Softcopy Presentation State 1.2.840.10008.5.1.4.1.1.11.1 1.2.840.10008.5.1.4.1.1.11.2 1.2.840.10008.5.1.4.1.1.11.3 1.2.840.10008.5.1.4.1.1.11.4 Table 9. DICOM Server Level 2 Conformance SOP Classes list DICOM Server gives a conformance to Signature Level 1. There is no timeout implementation in such process. 3.1.4.3 Data Query/Retrieve Real-World Activity 3.1.4.3.1 Description and Sequencing When a Data Query/Retrieve Real-World Activity is performed, a C-MOVE operation is performed. 3.1.4.3.2 Accepted Presentation Contexts Any Presentation Context of the following table will be accepted: Abstract Syntax Name Abstract Syntax UID Transfer Syntax Role Extended Negotiation Patient Root Query/Retrieve Information Model MOVE 1.2.840.10008.5.1.4.1.2.1.2 Any Transfer Syntax of Table 5 Study Root Query/Retrieve Information Model MOVE 1.2.840.10008.5.1.4.1.2.2.2 Any Transfer Syntax of Table 5 Patient/Study Query/Retrieve Information Model MOVE 1.2.840.10008.5.1.4.1.2.3.2 Any Transfer Syntax of Table 5 Table 10. Data Query/Retrieve Real-World Activity Accepted Presentation Contexts 3.1.4.3.3 SOP Specific Conformance for SOP Classes DICOM Server provides conformance to the DICOM Query/Retrieve Service Class as an for

the following Service SOP Classes: Service SOP Class Name Patient Root Query/Retrieve Information Model MOVE Study Root Query/Retrieve Information Model MOVE Patient/Study Query/Retrieve Information Model MOVE Patient Root Query/Retrieve Information Model GET Study Root Query/Retrieve Information Model GET Patient/Study Query/Retrieve Information Model GET Service SOP Class UID 1.2.840.10008.5.1.4.1.2.1.2 1.2.840.10008.5.1.4.1.2.2.2 1.2.840.10008.5.1.4.1.2.3.2 1.2.840.10008.5.1.4.1.2.1.3 1.2.840.10008.5.1.4.1.2.2.3 1.2.840.10008.5.1.4.1.2.3.3 Table 11. Data Query/Retrieve Real-World Activity DICOM Query/Retrieve Service Class Conformance Service SOP Classes list During a Data Query/Retrieve Real-World Activity, DICOM Server returns the Status in C-MOVE Responses with the following policy: Service Status Further Meaning Error Code Reason Success Success 0000 Data has been successfully sent to the destination Failure Failure A701 Error found while sending data Table 12. Data Query/Retrieve Real-World Activity C-MOVE Response Status policy 3.1.4.4 Information Query/Retrieve Real-World Activity 3.1.4.4.1 Description and Sequencing When an Information Query/Retrieve Real-World Activity is performed, a C-FIND operation is performed. 3.1.4.4.2 Accepted Presentation Contexts Any Presentation Context of the following table will be accepted:

Abstract Syntax Name Abstract Syntax UID Transfer Syntax Role Extended Negotiation Patient Root Query/Retrieve Information Model FIND 1.2.840.10008.5.1.4.1.2.1.1 Any Transfer Syntax of Table 5 Study Root Query/Retrieve Information Model FIND 1.2.840.10008.5.1.4.1.2.2.1 Any Transfer Syntax of Table 5 Patient/Study Query/Retrieve Information Model FIND 1.2.840.10008.5.1.4.1.2.3.1 Any Transfer Syntax of Table 5 Table 13. Information Query/Retrieve Real-World Activity Accepted Presentation Contexts 3.1.4.4.3 SOP Specific Conformance for SOP Classes DICOM Server provides conformance to the DICOM Query/Retrieve Service Class as an for the following Service SOP Classes: Service SOP Class Name Service SOP Class UID Patient Root Query/Retrieve Information Model FIND Study Root Query/Retrieve Information Model FIND Patient/Study Query/Retrieve Information Model FIND 1.2.840.10008.5.1.4.1.2.1.1 1.2.840.10008.5.1.4.1.2.2.1 1.2.840.10008.5.1.4.1.2.3.1 Table 14. Information Query/Retrieve Real-World Activity DICOM Query/Retrieve Service Class Conformance Service SOP Classes list During an Information Query/Retrieve Real-World Activity, DICOM Server returns the Status in C- FIND Responses with the following policy: Service Status Further Meaning Error Code Reason Success Success 0000 Query successfully completed Failure Failure A700 Error while performing query Table 15. Information Query/Retrieve Real-World Activity C-FIND Response Status policy Beyond unique and mandatory search keys, the following optional keys are supported for Patient Root, Study Root and Patient/Study C-FIND queries:

Key Tag Level Key Description 0010,0030 Patient Patient Birthdate 0010,0040 Patient Patient Sex 0008,1030 Study Study Description 0008,0061 Study Modalities in Study 0008,0021 Series Series Date 0008,103e Series Series Description Table 16. C-FIND Optional Keys C-FIND-CANCEL is not supported. 3.1.4.5 Modality Worklist Query/Retrieve Real-World Activity 3.1.4.5.1 Description and Sequencing When a Modality Worklist Query/Retrieve Real-World Activity is performed, a C-FIND operation is performed. 3.1.4.5.2 Accepted Presentation Contexts Any Presentation Context of the following table will be accepted: Abstract Syntax Name Abstract Syntax UID Transfer Syntax Role Extended Negotiation Modality Worklist Information Model FIND 1.2.840.10008.5.1.4.31 Any Transfer Syntax of Table 5 Table 13. Modality Worklist Query/Retrieve Real-World Activity Accepted Presentation Contexts 3.1.4.5.3 SOP Specific Conformance for SOP Classes DICOM Server provides conformance to the DICOM Query/Retrieve Service Class as an for the following Service SOP Classes: Service SOP Class Name Service SOP Class UID Modality Worklist Information Model FIND 1.2.840.10008.5.1.4.31 Table 14. Modality Worklist Query/Retrieve Real-World Activity DICOM Query/Retrieve Service Class Conformance Service SOP Classes list During a Modality Worklist Query/Retrieve Real-World Activity, DICOM Server returns the Status in C-FIND Responses with the following policy:

Service Status Further Meaning Error Code Reason Success Success 0000 Query successfully completed Failure Failure A700 Error while performing query Table 15. Modality Worklist Query/Retrieve Real-World Activity C-FIND Response Status policy Beyond unique and mandatory search keys, the following optional keys are supported for Modality Worklist C-FIND queries: Key Tag Key Description 0040,0006 Scheduled Performing Physician's Name Table 16. Modality Worklist C-FIND Optional Keys C-FIND-CANCEL is not supported.

4 Communication Profiles Linkverse DICOM Provider provides DICOM TCP/IP network communication support according to DICOM PS 3.8 2007. 4.1 TCP/IP Stack Linkverse DICOM Provider relies on the TCP/IP Stack of the Operating System. 4.1.1 Physical Media Support Linkverse DICOM Provider can be used with the physical medium the Operating System does support.

5 Configuration Configurable features: TCP Binding Port Number TCP Binding Address Application Entity Profiles (AE Title, SQL Indexing DB Name, FS Area Location) Remote Systems Profiles (AE Title, IP Address, TCP Port Number)