PMOD Features dedicated to Oncology Research

Similar documents
n o r d i c B r a i n E x Tutorial DSC Module

White Paper. EQ PET: Achieving NEMAreferenced. Technologies. Matthew Kelly, PhD, Siemens Healthcare

Automated segmentation methods for liver analysis in oncology applications

syngo.pet&ct Oncology CT Tutorial

Norbert Schuff VA Medical Center and UCSF

fmri/dti analysis using Dynasuite

Workbook for PMOD Version 3.9

13 CP Addition of Measurement Report Root Template for Planar and Volumetric ROIs

IDL Tutorial. Working with Images. Copyright 2008 ITT Visual Information Solutions All Rights Reserved

Medical Image Viewer Guide

Available Online through

13 CP Addition of Measurement Report Root Template for Planar and Volumetric ROIs

n o r d i c B r a i n E x Tutorial DTI Module

IDL Tutorial. Contours and Surfaces. Copyright 2008 ITT Visual Information Solutions All Rights Reserved

RADIOMICS: potential role in the clinics and challenges

HYBRID VIEWER. HERMES Data Analysis Applications. Hand book CD500.3_P31V 2.0C-2.1C. Template: T

Workbook for PMOD Version 3.5

Tutorial Visualization and Interaction

RT_Image v0.2β User s Guide

Voxar 3D ColonMetrix. Reference Guide

WorkstationOne. - a diagnostic breast imaging workstation. User Training Presentation. doc #24 (v2.0) Let MammoOne Assist You in Digital Mammography

Abbie M. Diak, PhD Loyola University Medical Center Dept. of Radiation Oncology

multimodality image processing workstation Visualizing your SPECT-CT-PET-MRI images

PMOD Image Segmentation Tool (PSEG)

3D Body. Summary. Modified by Admin on Sep 13, Parent page: Objects

Learn Image Segmentation Basics with Hands-on Introduction to ITK-SNAP. RSNA 2016 Courses RCB22 and RCB54

VIEW PRO 4D. four dimensions in one workstation

BrainMask. Quick Start

Chapter 11: Time Dependent Analysis(TDA) for Flow Analysis

Deviceless respiratory motion correction in PET imaging exploring the potential of novel data driven strategies

IMPAX Volume Viewing 3D Visualization & Segmentation

PMOD 3D Rendering Tool (P3D)

Chemotaxis Data Processing: Creating an Analysis Job

A New GPU-Based Level Set Method for Medical Image Segmentation

Visage 7 Clinical Training Basic Features

Interactive segmentation of vascular structures in CT images for liver surgery planning

Brain Mask User s Guide

3DMMVR REFERENCE MANUAL V 0.81

Saturn User Manual. Rubén Cárdenes. 29th January 2010 Image Processing Laboratory, University of Valladolid. Abstract

Norbert Schuff Professor of Radiology VA Medical Center and UCSF

Magnetic Resonance Elastography (MRE) of Liver Disease

Martin A. Lodge PET Center, Johns Hopkins Hospital, Nelson B1125, 1800 Orleans Street, Baltimore, MD 21287, USA

Automatic Lesion Detection for Measuring Response using Dynamic FDG-PET

Ambra User Guide. If you need help. Ambra Support (any time)

Opal RAD User Manual

BrainMask. Quick Start

Walk Through of CERR Capabilities. CERR: Introduction. Outline. Getting CERR: Control Panel. Documentation Support Community

Texture. Frequency Descriptors. Frequency Descriptors. Frequency Descriptors. Frequency Descriptors. Frequency Descriptors

Fluorescence Tomography Source Reconstruction and Analysis

Sante DICOM Editor 3D

Improvement of contrast using reconstruction of 3D Image by PET /CT combination system

ClinicalConnect TM eunity TM Training Guide

BoA Tools Page 1 / 31

Tutorial BOLD Module

Chapter 3 Image Registration. Chapter 3 Image Registration

Quantitative imaging for clinical dosimetry

Factors influencing image quality and quantification: optimization of PET parameters

SISCOM (Subtraction Ictal SPECT CO-registered to MRI)

icatvision Quick Reference

ECE 176 Digital Image Processing Handout #14 Pamela Cosman 4/29/05 TEXTURE ANALYSIS

AEMLog Users Guide. Version 1.01

syngo.mr Neuro 3D: Your All-In-One Post Processing, Visualization and Reporting Engine for BOLD Functional and Diffusion Tensor MR Imaging Datasets

VieW 3D. 3D Post-Processing WorKstation THE THIRD DIMENSION. Version 3.1

XD 3.6 Release Notes

DEVELOPMENT OF GEOMETRICAL MODELS OF HARD-ALPHA INCLUSIONS

µ = Pa s m 3 The Reynolds number based on hydraulic diameter, D h = 2W h/(w + h) = 3.2 mm for the main inlet duct is = 359

Hybrid Approach for MRI Human Head Scans Classification using HTT based SFTA Texture Feature Extraction Technique

TexRAD Research Version Client User Guide Version 3.9

Quantitative Analysis and Visualization with 3D Slicer

Gamepad Controls. Figure 1: A diagram of an Xbox controller. Figure 2: A screenshot of the BodyViz Controller Panel. BodyViz 3 User Manual 1

RTx Release Notes. Communicate any known limitations for the RTx release. Provide information on certain product features.

Tutorial Handling image data

JASCO CANVAS PROGRAM OPERATION MANUAL

Positron Emission Tomography (PET) Tumor Segmentation and Quantification: Development of New Algorithms

Quick Guide Software Version 4.4

Virtual MODELA USER'S MANUAL

PET/CT multimodality imaging for radiotherapy planning in lung cancer The medical physicist point of view Isabelle Gardin Rouen CHB and Quant.I.

Greenville County Internet Mapping System User s Guide

Semi-Quantitative Metrics in Positron Emission Tomography. Michael Adams. Department of Biomedical Engineering Duke University.

VisualSonics Application Protocol 3D Tumor Imaging using the MicroMarker Non-Targeted Contrast Agents

Norbert Schuff Professor of Radiology VA Medical Center and UCSF

User Manual Portable Laptop Console Crash Cart Adapter

CTA HEAD Perfusion AqONE without and with IV Contrast

SeeSnake HQ User Guide

The Anatomical Equivalence Class Formulation and its Application to Shape-based Computational Neuroanatomy

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

Technical Publications

button in the lower-left corner of the panel if you have further questions throughout this tutorial.

Algorithm User Guide:

Help Guide. mm Copyright Mirada Medical Ltd, Mirada Medical RTx 1

Stroke Quantification Tool (Sonia) Ver User Manual

Computational Medical Imaging Analysis Chapter 4: Image Visualization

Clinical Training for Visage 7 PET/CT

Getting Started with DADiSP

Using Web Camera Technology to Monitor Steel Construction

MEDICAL IMAGE NOISE REDUCTION AND REGION CONTRAST ENHANCEMENT USING PARTIAL DIFFERENTIAL EQUATIONS

Exploring Data. This guide describes the facilities in SPM to gain initial insights about a dataset by viewing and generating descriptive statistics.

Instructions for Display of Imaging Studies Using Stentor isite

Corridor4DM Feature List

HOW TO SETUP AND RUN SHIVA...

Transcription:

While brain research using dynamic data has always been a main target of PMOD s developments, many scientists working with static oncology data have also found ways to leverage PMOD s unique functionality. However, their needs and workflows have not been specifically addressed by PMOD so far. This is changed in the latest 3.9 version, which significantly improves functionality and usability for oncology research. This application note briefly illustrates 10 of the most salient new features. Please refer to the documentation for full coverage. 1. Global Oncology Configuration A new Oncology switch in the On Start section of the main configuration indicates to the program that high uptake lesion outlining, and assessment, will be the main application. As a result, the preferred use of SUV units is preset for image viewing and statistics. Outlined VOIs will be assumed to represent segmented lesions. Correspondingly, MTV (Metabolic Tumor Volume) and TLG (Total Lesion Glycolysis) will be output in the results of calculated statistics. For convenience and proper documentation, patient name and ID will by default appear in the image overlays. 2. SUV-based Image Viewing The default Oncology display unit is the widely used SUV based on body mass. However, as illustrated below, additional SUV variants are available, including the Janmahasatian formula for obese patients, and can easily be selected from a drop-down list. The color table settings and regional statistics will be based on the selected display unit. Color tables with a fixed SUV range for consistent image viewing can easily be configured. The first step is to select the appropriate SUV type as described above and define the lower and upper thresholds (e.g. 0-10 [g/ml]). Next, the definition can be saved via the button between the upper and lower image thresholds. PMOD Technologies, 2018 Revision: March 15, 2018 1 / 8

Finally, the tool configuration utility is opened and the color table set as default for PET data. From then on, all DICOM PET images loaded will be displayed using the defined color table setting. 3. Lesion Segmentation and Statistics Typically, oncologic lesions show up in PET images as bright areas of high uptake. Extensive literature exists on methods for delineating such lesions. In general, iso-contouring is applied in a box enclosing the lesion using either an absolute threshold, in SUV units, or a threshold relative to the SUV max or SUV peak. This can now easily be accomplished using hot-keys within the PMOD VOI functionality. The required specifications are located in the VOI Settings tab of the data inspector panel. PMOD Technologies, 2018 Revision: March 15, 2018 2 / 8

The VOI statistics in overlay section within the inspector panel allows a number of major VOI statistics to be automatically displayed in the image overlay. Once enabled, the results for the currently selected VOI(s) are overlaid. This functionality is intended to facilitate the documentation of results using screen captures illustrating lesion segmentation and calculated statistics. 4. Hot-key based Lesion Assessment Three types of VOIs can be generated by pointing the cursor at a lesion and using a keyboard hot-key combination. Their configuration parameters are defined in the VOI defined by hotkeys section in the inspector dialog. Essentially, a default bounding space around the location pointed out by the user must be defined, combined with a threshold methodology for the iso-contouring. The options are: 1. Spherical Peak VOI (Ctrl+Q). Specification: Diameter of an enclosing sphere. 2. Iso-contouring VOI within a bounding space at a specified level (Ctrl+L). Specifications: Enclosing box or sphere dimension; contouring value defined as Threshold in % of Max or % of Peak in the enclosing space, or absolute SUV. Frequently used configurations are 50% of SUV peak and 42% of SUV max. In case an absolute SUV threshold is used, the corresponding SUV display unit should be selected for image viewing. 3. Iso-contouringing VOI according to PERCIST recommendation at a threshold level obtained from a reference VOI in the liver (Ctrl+Shift+U, Ctrl+U, see below). A regiongrowing algorithm is applied from the seed point, connecting all pixels above the threshold. When using hot-key lesion segmentation, working in the orthogonal planes mode is recommended, with sufficient zoom and a maximum intensity projection (MIP) image. This layout makes it easy to point out the lesions. If the MIP image is not shown, it can be enabled and configured as illustrated below. Note the decreased upper threshold and the inverted gray color table. In order to apply hot-key iso-contouring once configured, the VOI functionality must be active. This means that the VOI definition tools need to be present. If they are not shown, the button switches them on. The user interface should look something like this: PMOD Technologies, 2018 Revision: March 15, 2018 3 / 8

5. Spherical Peak VOI in Bounding Sphere (Ctrl+Q) A lesion assessment introduced by the PERCIST methodology [1,2] is Peak VOI generation. In this method 1ml spheres are placed in the lesions such that their average is maximized. Naturally, this functionality is tailored for human data. For the quick assessment of lesion peak SUV in PMOD, proceed as follows: Click on a lesion in the MIP so that the image display triangulates on the lesion. Then click in the image planes until the plane intersection indicated by the blue lines is approximately central to the lesion of interest. Finally apply the keyboard shortcut Ctrl+Q. A bounding sphere is set and then the location of the 1ml peak sphere is optimized for maximum average. The resulting peak sphere VOI is shown in the image, together with the bounding VOI in dashed strokes. If overlay statistics are enabled, they also appear in the display. For example: This procedure can be repeated until all relevant lesions have been assessed. PMOD Technologies, 2018 Revision: March 15, 2018 4 / 8

6. Iso-Contouring VOI in Bounding Box (Ctrl+L) For quick iso-contouring, triangulate the lesion center as described above, then activate the keyboard shortcut Ctrl+L. The defined bounding box is set and iso-contouring is performed within, using the configured methodology. The resulting contour is shown in the image, together with the bounding VOI. The example shown below used a bounding box and isocontouring at 42% of the maximum value in the box. 7. PERCIST-type Iso-contouring VOI based on Liver VOI (Ctrl+Shift+U, Ctrl+U) Instead of basing iso-contouring on the values in the lesion itself or an absolute SUV, the threshold can be obtained from the uptake in a reference tissue. PERCIST (PET Response Criteria in Solid Tumors) [1,2] obtains the background activity from a 3-cm diameter sphere placed in the right side of healthy liver, midway between the dome and inferior margin, excluding central ducts and vessels. The procedure for a PERCIST-conformant assessment is as follows: 1. Triangulate the point in the liver as described above. Activate keyboard shortcut Ctrl+Shift+U to place the 3cm diameter reference sphere. The minimal level of tumor uptake is calculated as 1.5*Average liver +2*StandardDeviation liver. This value is used as isocontouring threshold in the subsequent lesion assessment. 2. Triangulate the center of each lesion, then activate Ctrl+U. A region-growing algorithm is applied and the pixels above the threshold are outlined. The configured statistics are calculated and displayed. If uptake in the lesion remains below the minimal tumor level, no iso-contouring VOI is found and the lesion is not measurable with PERCIST. PMOD Technologies, 2018 Revision: March 15, 2018 5 / 8

Each lesion can be documented by screen capture as described below. Note the Peak value, which is the relevant outcome for PERCIST. 8. Sorting of Segmented Lesions Once the lesions have been segmented, they can be ordered according to different criteria, such as size, MTV, SUV mean, SUV peak, SUV max. In this way, the most relevant lesions are easily brought to the top of the list for further evaluation and documentation. In contrast to RECIST, which employs the largest diameter in the measurement plane to quantify lesion size, PMOD supports the longest oblique diameter in three-dimensional space. 9. Documentation of Segmented Lesions In order to document the segmentation and the resulting statistics, screen capturing has been improved. It can be called using the Ctrl+E keyboard shortcut or the corner button indicated below. The output is defined in the dialog window that appears. PMOD Technologies, 2018 Revision: March 15, 2018 6 / 8

Active area only captures the content of the selected quadrant, whereas Full Display captures the whole image area, including MIP. The output format is selected in the upper part: Either a DICOM secondary capture image can be saved or directly sent to a PACS system (C-Store), or a graphic image file format can be specified for saving. Note the new Console output, which sends the capture to an image buffer in the console. When opening the console later on, the captured images can be inspected and the relevant ones saved. PMOD Technologies, 2018 Revision: March 15, 2018 7 / 8

10. Texture Analysis Texture analysis quantifies the variability of the pixel intensities within a structure such as a tumor. There is a plethora of texture metrics, any of which may facilitate in vivo lesion characterization and provide predictive information about the tumor malignancy. PMOD provides a collection of 25 indexes that have been found to be most valuable in the context of PET imaging. Six are based on the pixel histogram within a VOI, and 19 based on the gray level co-occurrence matrix (GLCM). Once the lesions are segmented, texture analysis can simply be called from the statistics menu. The resulting table lists the texture values for each defined lesion, and supports data export for further evaluation and research. References [1] Wahl RL, Jacene H, Kasamon Y, Lodge MA: From RECIST to PERCIST: Evolving Considerations for PET response criteria in solid tumors. J Nucl Med 2009, 50 Suppl 1:122S- 150S. [2] O JH, Lodge MA, Wahl RL: Practical PERCIST: A Simplified Guide to PET Response Criteria in Solid Tumors 1.0. Radiology 2016, 280(2):576-584. PMOD Technologies, 2018 Revision: March 15, 2018 8 / 8