VARAN Bus Coupler Module VBC 021 For connecting two VARAN bus systems

Similar documents
VARAN Splitter Module VSV 043

VARAN Splitter PROFINET VSP 042

VARAN Splitter Module VSV 041

VARAN Splitter PROFINET VSP 044

DIAS Interface Module VARAN DIV 511

C-DIAS VARAN Control Module CIV x VARAN-In 1 x VARAN-Out (Optional Ethernet (VtE))

VARAN Manager PCI Insert module PCV 521 Versatile Automation Random Access Network

VI 021 S-DIAS VARAN Control Module

VARAN Digital Combined Module VDM 086

Protected VARAN Digital Mixed Module PVDM 086

VARAN Client Board VEB 011/012 Versatile Automation Random Access Network

VARAN-INTERFACE VAC 012

C-IPC Expansion VM 052 (C-IPC VARAN Manager 052) Versatile Automation Random Access Network

C-DIAS Digital Input Module CDI 161 with 16 inputs

Expansion Module HZS 541-1S

C-DIAS EtherNet/IP Slave CIP 022

ISE 021 S-DIAS Interface Module RS232 / RS485

to 12a Added Standard and Electrical requirements for UL table 1.1

ICA 012 S-DIAS Interface Module CAN

C-DIAS Temperature sensing module CAI x temp. inputs C 8 x digital outputs +24V

Technical Data. C-DIAS-MULTI l/o MODULE CIO 013

HZS Internal Controller Expansion

PC 521 Data Recording PC

SE 051 S-DIAS Splitter Ethernet

TSY 041 Training System Extension Motion

PS 101 S-DIAS Power Supply Module

TO 161 S-DIAS Digital Output Module

RO 051 S-DIAS Relay Output Module

AO 081 S-DIAS Analog Output Module

C-DIAS Analog Module CAO 086 For eight ±10 V Outputs

SI 021 S-DIAS SSI Interface Module

C-DIAS Serial Interface CSI 021

C-DIAS Analogue Output Module CAO 081 for eight 10V DC outputs

AI 046 S-DIAS Analog Input Module

Auxiliary Board MP-Bus HZS 562

Added Standard and Electrical requirements for UL table Switching-off inductive loads 1.2

Internal Buffer/Boiler Module HZS 534

C-DIAS Analogue Output Module CAO 082 for eight ±10V DC respectively eight 0 20mA DC outputs

DM 161 S-DIAS Digital Mixed Module

C-DIAS-Temperature Recording module CAI x Temp. inputs 50 C to +150 C

KL 181 S-DIAS +24 V Potential Distributor Module

C-DIAS Analogue Conversion Module CAM 124 for eight 0 10V DC inputs and four 10V outputs

DC S-DIAS Axis Module

TAE 1921 Touch Display Unit

HZS Solar Module

C-DIAS Profibus DP Slave module CPB 021

Profibus DP slave. dual ported RAM 2Kbyte. Maximum length for I/O data. Maximum length for output data. Status display

ETT 312 Build-In Touch Terminal

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O

TAE 1921 Touch Display Unit

ETT 352 Touch Operating Panel

Connection Cables for Operating Devices

C-DIAS Analog Input Module CAI 086 For eight, ±10V voltage inputs

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

Keyboard Unit Sigmatek

HZS 352 Touch Room Unit

GIN-SAM4. Hardware User Manual. Version: 1.02 Date: Language: English

PC 400 Control Cabinet PC

C-DIAS Analogue Conversion Module CAM 011 for 3 x 0-10V DC inputs 2 x PT100 inputs and 1 x ±10V output

Industrial Ethernet Switch

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

AO561 Analog Output Module

Operating instructions Diagnostic electronics for vibration sensors VSE002 / VXE002 / VXE003 VYE001 / VYE002 / VYE003 / VYE /01 05/2015

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

gigabit industrial ethernet user manual Models , ,

Rugged Industrial Media Converter

AI561 Analog Input Module

IST ULTRASTAB Power Supply for high precision transducers

User Manual Gateway component for EtherNet/IP

TF501, TF521 Terminal Bases

DI572 Digital Input Module

DX561 Digital Input/Output Module

Ha-VIS mcon 3000 Next Generation Introduction and features

HZS 351 Room Touch Control Panel

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

CM597 Ethernet Communication Module

DI561 Digital Input Module

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 480 a at 40 C Mission Time (T M ) L 10

DC562, digital input/output module,

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

TM241CE24T controller M IO transistor PNP Ethernet

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

Documentation. CU20xx, CU22xx. Ethernet Switch. Version: Date:

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

IPC 221 Industrial PC

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

F1000 User's Manual. (Version: V1.01)

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 480 a at 40 C Mission Time (T M ) L 10

RMCN22BD Analog Converter ma - for Zelio Analog

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

MINI-PS AC/10-15DC/8

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

TM258LF42DT compact base M I/O - 24 V DC - CANopen

MobileView Junction Box

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Micropulse Transducers

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Hardened Ethernet Switch. Signamax Connectivity Systems. Hardened Ethernet Switch. Model G Series. User s Guide

Transcription:

VARAN BUS COUPLER MODULE VBC 021 VARAN Bus Coupler Module VBC 021 For connecting two VARAN bus systems VARAN 1: VARAN 2: 1 x VARAN In 2 x VARAN Out 1 x VARAN In 1 x VARAN Out 1 x ETHERNET Port VARAN transmits Ethernet (VtE) This bus coupler module is used to connect two independent VARAN bus systems. Data can be exchanged between the two bus systems over VtE and two double buffers (synchronous and asynchronous). The VBC 021 also ensures that both bus systems synchronize. until HW 1.x since HW 2.x Technical Data Performance data Interface connections 1 x ETHERNET Port VtE (RJ45) 10/100MBit VARAN1: 1 x VARAN In (RJ45) 2 x VARAN Out (RJ45) VARAN2: 1 x VARAN In (RJ45) 1 x VARAN Out (RJ45) (maximum length VARAN: 100 m) Internal data memory (SPI-Flash) 4 MBit/s 10.04.2018 Page 1

VBC 021 VARAN BUS COUPLER MODULE Electrical requirements Supply voltage Current consumption of voltage supply 18 30 V DC Typically 200 ma (at + 24 V) (until HW 1.x) Typically 120 ma (at + 24 V) (since HW 2.x) Only suitable for connection to secondary isolated power supply rated 24 V DC. Fuse in accordance with UL248 shall be connected in the field between the supply source and device terminals. Uniquement pour la connexion à une alimentation isolée secondaire de tension nominale 24 V DC. Un fusible conforme UL248 doit être placé entre la source d'alimentation et les bornes de l'appareil. Miscellaneous Article number 16-054-021 Hardware version 1.x, 2.x Environmental conditions Storage temperature -20 +85 C Environmental temperature 0 +60 C Humidity EMC stability *) EMC noise generation 0-95 %, uncondensed According to EN 61000-6-2 (industrial area) According to EN 61000-6-4 (industrial area) Shock resistance EN 60068-2-27 150 m/s² Protection Type EN 60529 IP 20 *) Control box mounting required Page 2 10.04.2018

Mechanical Dimensions until HW 1.x VARAN BUS COUPLER MODULE VBC 021 10.04.2018 Page 3

VBC 021 VARAN BUS COUPLER MODULE Mechanical Dimensions since HW 2.x Page 4 10.04.2018

VARAN BUS COUPLER MODULE VBC 021 Connector Layout Connector Layout until HW 1.x Connector Layout since HW 2.x 10.04.2018 Page 5

VBC 021 VARAN BUS COUPLER MODULE X1: ETHERNET Port (VtE) Pin 1 TX/RX + 2 TX/RX - 3 RX/TX + 4-5 not connected 6 RX/TX - 7 8 GND LEDs Yellow Green ACTIVE LINK LED Color Description ACTIVE Yellow Lights when data is exchanged over the ETHERNET LINK Green Lights when the connection between the two PHs is established Green Blinks when data is received over the ETHERNET X2: VARAN 1 IN Pin 1 TX/RX + 2 TX/RX - 3 RX/TX + 4-5 not connected 6 RX/TX - 7 8 GND LEDs Yellow Green ACTIVE LINK LED Color Description ACTIVE Yellow Lights when data is exchanged over the VARAN bus LINK Green Lights when the connection between the two PHs is established Green Blinks when data is received over the VARAN bus Page 6 10.04.2018

VARAN BUS COUPLER MODULE VBC 021 X3: VARAN 2 IN Pin 1 TX/RX + 2 TX/RX - 3 RX/TX + 4-5 not connected 6 RX/TX - 7 8 GND LEDs Yellow Green ACTIVE LINK LED Color Description ACTIVE Yellow Lights when data is exchanged over the VARAN bus LINK Green Lights when the connection between the two PHs is established Green Blinks when data is received over the VARAN bus X4: VARAN 1 OUT1 Pin 1 TX/RX + 2 TX/RX - 3 RX/TX + 4-5 not connected 6 RX/TX - 7 8 GND LEDs Yellow Green ACTIVE LINK LED Color Description ACTIVE Yellow Lights when data is exchanged over the VARAN bus LINK Green Lights when the connection between the two PHs is established Green Blinks when data is received over the VARAN bus 10.04.2018 Page 7

VBC 021 VARAN BUS COUPLER MODULE X5: VARAN 2 OUT Pin 1 TX/RX + 2 TX/RX - 3 RX/TX + 4-5 not connected 6 RX/TX - 7 8 GND LEDs Yellow Green ACTIVE LINK LED Color Description ACTIVE Yellow Lights when data is exchanged over the VARAN bus LINK Green Lights when the connection between the two PHs is established Green Blinks when data is received over the VARAN bus X6: VARAN 1 OUT2 Pin 1 TX/RX + 2 TX/RX - 3 RX/TX + 4-5 not connected 6 RX/TX - 7 8 GND LEDs Yellow Green ACTIVE LINK X7: Power plug Pin 1 +24 V supply 2 GND Useable connectors Connector with spring clamp: Phoenix Contact: FK-MCP 1.5/ 2-ST-3.5 The complete C-DIAS plug set CKL 141 with spring clamp is available from SIGMATEK with the article number 12-600-141. Page 8 10.04.2018

VARAN BUS COUPLER MODULE VBC 021 Detailed Description General The VBC 021 appears in each of the VARAN bus systems as an independent VARAN client. Synchronizing VARAN bus systems In combination with the hardware classes, the VBC 021 ensures that both bus systems are synchronized with one another. As soon as the isochronous task has started in both VARAN bus systems, the VBC 021 starts to measure the phase offset between the two bus systems. The hardware class ensures that in VARAN bus 2, the VARAN-Manager regulates its bus cycle so that both systems are synchronized. CAUTION! In a VARAN system with the VBC 021, all nodes must support VARAN protocol version v1.4.0, since individual clients can be asynchronous with the manager. The VBC 021 function for synchronizing two VARAN systems is provided starting with VARAN protocol version v1.4.0! CAUTION! The VARAN 2 side of a VBC 021 must only be present once within a VARAN bus system, otherwise conflicts will occur during synchronization. For CPUs with multiple VARAN Managers, this applies to both VARAN Managers. Synchronous double buffer The synchronous double buffer (1kbyte) ensures that data exchange between the two bus systems is possible through the synchronous bus cycle without the danger of inconsistent data. Asynchronous double buffer The asynchronous double buffer (1kbyte) ensures that data exchange between the two bus systems is possible through the asynchronous bus cycle without the danger of inconsistent data. 10.04.2018 Page 9

VBC 021 VARAN BUS COUPLER MODULE VARAN transmits ETHERNET (VtE) The VARAN bus provides the possibility to transmit Ethernet packets. Some VARAN clients have an Ethernet port. The incoming Ethernet packets are distributed, as with a HUB, to all other Ethernet ports in the VARAN bus and the VARAN- Manager (and therewith the CPU) using VtE. With the VBC 021 Ethernet packets in a VARAN bus are not only provided using VtE in the Ethernet port, but also transmitted to the other VARAN bus and from there, distributed with VtE to the Manager and all other clients with a VARAN Ethernet port. Page 10 10.04.2018

Bust Structure on the VBC 021 VARAN BUS COUPLER MODULE VBC 021 The VARAN bus can be configured in a tree and/or linear structure. The advantage of the tree structure is shorter response times from the farthest VARAN clients that with a linear structure. The VBC 021 allows the configuration of a tree structure on the VARAN 1 side; on the VARAN 2 side, the continuation of a linear structure is possible. 10.04.2018 Page 11

VBC 021 VARAN BUS COUPLER MODULE Recommended Shielding for VARAN The VARAN real-time Ethernet bus system exhibits a very robust quality in harsh industrial environments. Through the use of IEEE 802.3 standard Ethernet physics, the potential between an Ethernet line and sending/receiving components are separated. In the event of an error, the VARAN Manager resends messages to a bus participant immediately. It is principally recommended that the shielding guidelines below be followed. For applications in which the bus is run outside the control cabinet, the correct shielding is required. This is especially important, if due to physical requirements, the bus cables must be placed next to sources of strong electromagnetic noise. It is recommended that whenever possible, to avoid wiring VARAN-Bus lines parallel to power cables. SIGMATEK recommends the use of CAT5e industrial Ethernet bus cables. For the shielding variants, an S-FTP bus line is recommended. An S-FTP bus is a symmetric, multi-wire cable with unshielded pairs. For the total shielding, a combination of foil and braiding is used. A non-laminated variant is recommended. The VARAN cable must be secured at a distance of 20 cm from the connector for protection against vibration! Page 12 10.04.2018

VARAN BUS COUPLER MODULE VBC 021 1. Wiring from the Control Cabinet to an External VARAN Component If the Ethernet lines are connected from a VARAN component to a VARAN node located outside the control cabinet, the shielding should be placed at the entry point to the control cabinet housing. All noise can then be deflected from the electronic components before reaching the module. 10.04.2018 Page 13

VBC 021 VARAN BUS COUPLER MODULE 2. Wiring Outside of the Control Cabinet If a VARAN bus cable must be placed outside of the control cabinet only, no additional shield connection is required. This requires that only IP67 modules and connectors be used. These components are very robust and noise resistant. The shielding for all sockets in IP67 modules are internally connected to common bus or electrically connected to the housing, whereby the deflection of voltage spikes does not flow through the electronics. Page 14 10.04.2018

VARAN BUS COUPLER MODULE VBC 021 3. Shielding for Wiring Within the Control Cabinet Sources of strong electromagnetic noise located within the control cabinet (drives, Transformers, etc.) can induce interference in a VARAN bus line. Spike voltages are deflected over the metallic housing of a RJ45 connector. Noise is conducted through the control cabinet housing without further action from the electronic components To eliminate sources of noise during data transfer, it is recommended that the shielding for all electronic components be connected within the control cabinet. 10.04.2018 Page 15

VBC 021 VARAN BUS COUPLER MODULE 4. Connecting Noise-Generating Components With the connection of power components, which generate strong electromagnetic interference, it is also critical to ensure correct shielding. The shielding should be placed before a power component (or a group thereof). Page 16 10.04.2018

5. Shielding Between Two Control Cabinets VARAN BUS COUPLER MODULE VBC 021 If two control cabinets must be connected over a VARAN bus, it is recommended that the shielding be located at the entry points of both cabinets. Noise can be thereby stopped from reaching the electronics within the control cabinet. 10.04.2018 Page 17

VBC 021 VARAN BUS COUPLER MODULE Page 18 10.04.2018