FieldLink process networking

Similar documents
JM - Junction Enclosure Modules for Communication Networks

Dual Module VCT. 5. Lexan Enclosure is Water & Corrosion Proof Contaminants will not affect the module as long as terminal strip is not immersed.

FieldLink process networking. Pricing January 2, 2018

AS-interface Network Card

Advanced I/O Module with AS-Interface Protocol

IHP24. Intelligent Hydraulic Positioner D HP- PL

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

Intellis Network Control Monitors

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

New FOUNDATION Fieldbus Interface Techniques Increased Availability and Reduced Costs. Andreas Agostin Pepperl+Fuchs

Diagnostics (Physical)

Installation and Operating Instructions

SmartWire-DT In panel and on machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators

Industrial Electric Actuators AC and DC Voltages Nm/ inch lbs

INTELLIS. WESTLOCK Network Systems Group NETWORK SYSTEMS FOR VALVE AUTOMATION. ModBus, DeviceNet, AS-interface Profibus, Foundation Fieldbus

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 NPT

FEATURES DESCRIPTION

F101, F102, F104. Relcom Installation Instructions. Fieldbus Power Supply F101-PS

INSTALLATION INSTRUCTIONS

Diagnostics (Logical) Diagnostics (Physical)

Installation & Operation Manual

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Level-Lance Model 5400A

FOOD AND BEVERAGE AUTOMATION & ELECTRICAL SOLUTIONS

AccuTank ULTRASONIC LEVEL MONITORING SYSTEM

SmartWire-DT In-panel and on-machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

ERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

Electrical Demand Specification (Reference SOP: )

Trusted Strategic Partners in Process Automation. Alliance Member

VALVE NETWORKING MONITORING AND CONTROL. Monitoring and Control Products & CApabilities

Electric actuator for quarter-turn valves. For output torques to 17,700 lb. in.

Level instruments. Point level measurement - Capacitance switches. Pointek CLS300 5/31

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

Vibration Switches viib

Flow Measurement SITRANS F M

SS2200 Remote Controller

PRODUCT INFORMATION. AUMA Actuators, Inc. Pittsburgh PA USA. Triple Play Digital Communications Board DeviceNet / Modbus CDN455

Type 330SA High-Performance Electric Actuator

Distributed Intrinsically Safe Fieldbus Applications

Model 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications.

M-series Intrinsically Safe I/O

ArmorConnect Power and Control Media

MIGHTY INSTRUMENTS. Installation and Maintenance Manual

Submersible Liquid Level Transmitter Series: PT-500

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

Skilmatic SI-1Q. Keeping the World Flowing. Spring-Return Electric Quarter-Turn Actuator (65 to 480 Nm)

Product Data. Model 675 Shark Cage Submersible Level Transmitter ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Process Valve Networking 101: What, Why and How Much?

FLEX Ex Spring Clamp Terminal Base

Remote Process Actuation Control System AirLINE PHOENIX INLINE

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

Roxar CorrLog High Accuracy Corrosion Monitoring

Discrete I/O connected direct onto. Input and Output Function Blocks. Two built-in Solid State Relay Outputs. Discrete Function Blocks in the field

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

2-IQ Series Smart Valve Positioners

remote I/O future inside

CONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Revolutionizing control wiring

S-series Electronic Marshalling

PD ProtEX-MAX Analog Input Feet & Inches Meter. IECEx MAX

Flow Measurement SITRANS F M

System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters

VALVE ACCESSORIES & CONTROLS V100 POSITIONER VAC V100 SERIES POSITIONER SIMPLE DURABLE RELIABLE

APPLICATION GUIDE. Interface Modules IM Series.

LTM IntelliGage Series Magnetostrictive Level Transmitters

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

PCG550, PCG552, PCG554

PROFIBUS-PA Positioner Type 3785

Level gauges Series LS Level indicator, switch and transmitter for liquids

Trident and Trident X2 Digital Process and Temperature Panel Meter

ICO3S - 2/2, 3/2 or 5/2 poppet valves Electromagnetically actuated, direct solenoid operated

Versatile Safety Interlock Switch with Guard Door Locking

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

SITRANS F flowmeters SITRANS F US

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

SCADAPack Modbus multivariable transmitter

S-series Electronic Marshalling

MAXIMA + Series ROTARY LEVEL CONTROL

SVI II ESD. SIL3 Partial Stroke Test Device October 2007 BW5000-ESD. The only SIL3 Smart ESD device that is live during and after a shutdown.

Level instruments. Point level measurement - Capacitance switches. Pointek CLS200 5/15. Overview. Configuration

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

On-Machine Modular I/O

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

Roxar SandLog High Accuracy Sand/Erosion Monitoring

PD ProtEX-MAX TM Explosion-Proof Process Meter. IECEx MAX

Remote Process Actuation Control System AirLINE PHOENIX INLINE

PSG550, PSG552, PSG554

Honeywell Model 700/800 Signal Processor and Viewing Head

Foundation Fieldbus. actuator control. Established Leaders in Actuation Technology. Foundation Fieldbus. Freedom to Choose, Power to Integrate

Safety Instructions Cerabar S PMP71, PMP75

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

Operating pressure (bar)

THE FULL RANGE FOR PROCESS AUTOMATION. This document provided by Barr-Thorp Electric Co., Inc

Transcription:

FieldLink process networking Enclosures Junction module (JM) StoneL s Junction Module (JM) enclosure is an environmetally hardened platform which is suitable for use in the most extreme corrosive and hazardous process environments. The JM features a wide variety of bus networking capabilities for protocols used in the process industries. Because of its flexibility and functionaiity it has become an essential building block for bus network users in the processing industries. No seal-offs in Division 1 & 2 hazardous areas Eliminate costly seal fittings in Class I & II Division 1 & 2 areas when installing bus networks using StoneL s JM enclosures. Because the JM enclosure has passed special pressure piling tests simulating the extreme pressures caused by remote conduit ignition, no seal offs are required in either Div 1 or Div 2 areas. Keep bus energized during maintenance in Division 1 areas FM approved factory-sealed leads are available for the drop leg of the switched drop connector. In Division 1 areas the conduit must not be opened to atmosphere when wires are energized. However, with factory-sealed leads no energized wires are exposed to the atmosphere when the drop leg is opened or JM with switched drop removed for maintenance even though the bus trunk remains energized. Features 7 6 4 5 3 1. Rugged enclosure This enclosure is constructed of durable, marine grade anodized aluminum with two coats of epoxy. Optional clear polycarbonate cover enables observation of circuit status without opening the enclosure. 2. Hazardous approval ratings JM may be used in explosionproof and general purpose applications. 1 2 3. Quick access Screw-on cover enables convenient access to the enclosure. 4. Vapor tight and submersible Rated for IP67 and NEMA 4, 4X and 6, the JM withstands rigorous washdowns and corrosive environments. 5. Wide variety of functions Select from drop connectors, switched drop connectors, relay modules, I/O modules, power conditioners, and special module configurations. 6. Compact design JM s size minimizes space requirements for wiring and conduit layout. 7. Convenient wiring Experience quick and secure wiring with the clearly labeled, top insertion terminal strips. 1.218.739.5774 140 StoneL.com

Enclosures process networking FieldLink JM enclosure functions Drop connectors Drop connectors enable individual spurs to be conveniently wired to the bus trunk. They are available in either passive or protected versions. Passive drop connectors directly connect bus and spur wiring via standard pre-labeled wire terminals. Protected drop connectors include a solid state protection circuit which detects a fault condition on the spur and isolates the spur from the bus. Bus operation is unaffected yet the bus master will be able to detect the faulted spur. Local LED indication may be viewed through the clear Lexan cover indicating a fault condition. Specifications Protocols Passive Protected Protected (2 drops) Maximum voltage Maximum current (trunk) Voltage drop (trunk) Voltage drop (drop) Trip current (drop) Holding current (after trip) Reset current level Maximum devices per drop Current consumption AS-Interface, DeviceNet, Foundation Fieldbus, Profibus-PA, Profibus-DP and Modbus JMT models (AS-i, DN, MB/PB-DP and FF/PB-PA) JMP models (AS-i and FF/PB-PA) JMD models (AS-i and FF/PB-PA) 35VDC 8 amps Negligible Passive: negligible Protected: <1V Passive: no trip current (AS-i, FF/PB-PA and MB/PB-DP) Protected: 40mA (FF/PB-PA) Protected: 240mA (AS-i) Protected: 28mA Protected: current falls below 28mA Passive: no limit Protected: 1 None Switched drop connectors Each spur may be individually energized or de-energized using the switched drop connector. Protection circuitry comes standard in the drop connection providing fault protection for the bus while the spur is energized. The JM switched drop connector may be locked and/or tagged out assuring safe working conditions for the maintenance of field device(s) attached to the spur while the bus remains energized. The bold on and off labeling may be seen clearly up to 20 feet away, making bus status clearly viewable in the plant environment. Specifications Protocols Protected Power protected Maximum voltage AS-Interface, DeviceNet, Foundation Fieldbus, Profibus-PA, Profibus-DP, & Modbus JMS models (AS-i & FF/PB-PA) JMS models (DN & MB/PB-DP) 35VDC Maximum current (trunk) 8 amps Voltage drop (trunk) Negligible Voltage drop (drop) <1V Trip current (drop) 40mA (FF/PB-PA) 240mA (AS-i) 200mA (DN & MB/PB-DP) Holding current (after trip) 28mA Reset current level Current falls below 28mA Maximum devices per drop 1 Current consumption None StoneL.com 141 1.218.739.5774

FieldLink process networking Enclosures JM enclosure functions I/O modules Interface field devices into the bus network in hazardous environments with JM I/O modules. Connect analog 4 to 20mA instrumentation inputs and outputs or discrete inputs and outputs to the module and take advantage of incredible installation savings. Specifications for I/O modules Protocol Models AS-Interface profile Discrete inputs Discrete outputs Analog input Analog output JMM96 JMM97 (extended addressing) JMM96: ID = F, I/O = 7 (4DI, 4DO) JMM97: ID = A, I/O = 7 (4DI, 3DO) (4) 3mA @ 28VDC gold contact JMM96: (4) 28VDC (4 Watts total power available) JMM97: (3) 28VDC (4 Watts total power available) JMM92 (2) 7mA @ 24 VDC gold contact (2) 24 VDC (4 watts total power available) (1) Analog (4-20mA) input 10-bit JMM93 (bus powered) JMM94 (externally powered) (2) 6.5 VDC <.045mA, must be low power dry contact capable of operating at <.045mA @ 6.5VDC or solid state pnp capable of operating at 6.5VDC and <1mA JMM93: (2) 6.5 VDC 2mA. Suitable for StoneL piezo valve JMM94: (2) 24 VDC (4 watts total power) JMM94: (1) analog (4-20mA) input 10-bit JMM94: (1) analog (4-20mA) output 10-bit Operating voltage AS-Interface voltage 24 VDC via DeviceNet voltage 9 to 32 VDC via Foundation Fieldbus voltage Current consumption Indication External voltage <40mA (with no outputs energized) <60mA (with no outputs energized) <17mA status (red/ green) JMM94: 24 VDC via external power JMM95 (2) 7mA @ 24 VDC gold contact (2) 24VDC (4 watts total power available) (1) analog (4-20mA) input 10-bit 24 VDC <20 ma (no outputs energized and no analog input) Data rate 167 kb/s 125, 250, 500 kb/s 31.25 kb/s 9,600, 19,200, 38,400 baud (software settable) 1.218.739.5774 142 StoneL.com

Enclosures process networking FieldLink JM enclosure functions Relay modules Independent or Interlocked relay modules are integrated with each of the I/O modules to provide high power output switching capabilities. (AS-Interface, DeviceNet, Modbus and Foundation Fieldbus externally powered I/O modules are available with relay outputs.) The 2-DO from the I/O modules drive the two relays providing high power switching operation to separate high power circuits. All other functions of the I/O modules remain the same. Specifications for relay modules Protocol Models: independent Models: interlocking AS-Interface profile Discrete inputs Discrete outputs (relay) independent interlocking Bus powered outputs Analog input Analog output JMR96 JMR97 (extended addressing) JMI96 JMI97 (extended addressing) JM_96 ID = F, I/O = 7 (4DI, 4DO) JM_97 ID = A, I/O = 7 (4DI, 3DO) (4) 3mA @ 28VDC gold contact (2) 120/250VAC fused @ 2A independent for other AC loads (2) 120/250VAC fused @ 2A interlocked for motor operation 96: (2) 28VDC (4 Watts total power available) 97: (1) 28VDC (4 Watts total power available) JMR92 JMR94 (externally powered) JMR95 JMI92 JMI94 (externally powered) JMI95 (2) 7mA @ 24 VDC gold contact (2) 120/250VAC @ 2A independent for other AC loads (2) 120/250VAC @ 2A interlocked for motor operation (1) analog (4-20mA) input 10-bit (2) 6.5 VDC <.045mA, must be low power dry contact capable of operating at <.045mA@6.5VDC or solid state pnp capable of operating at 6.5VDC and <1mA (2) 120/250VAC @ 2A independent for other AC loads (2) 120/250VAC @ 2A interlocked for motor operation (1) analog (4-20mA) input 10-bit resolution (0.1%) (1) analog (4-20mA) output 10-bit Operating voltage AS-Interface voltage 24 VDC via DeviceNet voltage 9 to 32 VDC via Foundation Fieldbus voltage Current consumption Indication External voltage (analog I/O) External voltage (relay outputs) <40mA (with no outputs energized) <60mA (with no outputs energized) <17mA status (red/ green) 24 VDC via external power (2) 7mA @ 24 VDC gold contact (2) 120/250VAC @ 2A independent for other AC loads (2) 120/250VAC @ 2A interlocked for motor operation (1) analog (4-20mA) input 10-bit 24 VDC <20 ma (no outputs energized and no analog input) Up to 250 VAC; 30 VDC Up to 250 VAC; 30 VDC Up to 250 VAC; 30 VDC Up to 250 VAC; 30 VDC StoneL.com 143 1.218.739.5774

FieldLink process networking Enclosures JM enclosure functions I/O modules with integral solenoid valve An integral Cyclone pneumatic valve may be selected that is electrically sized to be compatible with the I/O module outputs. An ultra low power piezo valve which may be driven directly from the bus-powered Foundation Fieldbus module is also available. Total power consumption with the piezo and FF module is less than 16mA, maximizing the number of units on any one segment! Specifications, JMM models Configuration Flow rating Porting Operating pressure Operating life Valve body material Solenoid pilot Current requirement Single pilot, 5-way 2-position spring return or double pilot, 5-way 2-position shuttle piston 0.7 Cv (10.7 Kv) 1/4 NPT 25 to 120 psi (1.7 to 7.5 bar) 1 million cycles 360 brass or 303 stainless steel 75mA @ 24VDC Schematics Spring return Shuttle piston Operating temperature -18 to +50 C (-4 to 122 F) Filtration requirement 40 micron Piezo pilot Current requirement 2mA @6.5 VDC Operating temperature -10 to +60 C (+14 to 140 F) Filtration requirement Approvals 5 micron, Dried Ex ia IIC T6 Special modules, JMX models A variety of other functions are available with the JM. The following options provide essential networking capabilities in hazardous or general purpose environments. Bus-powered Foundation Fieldbus with Hawkeye sensors StoneL has developed ultra-low power Hawkeye sensors which are fully functional with the FF buspowered module. For applications with linear operators, or for those requiring point sensing discrete inputs in the process environment, this is an ideal solution. AS-Interface combination repeater and power conditioner AS-Interface combination repeater and power conditioner extends your network length easily in hazardous and general purpose locations. AS-Interface power conditioner Power for two-wire bus networks must be decoupled from the communication signal for proper operation. With the JM power conditioner, the power supply may be located in a safe area with the power conditioner located in the field. Distance from the power supply to the power conditioner does not add to effective bus length. AS-Interface repeater This repeater extends the usable length of the AS-Interface network by 100 meters. The repeater requires one (1) AS-Interface power supply or an AS-Interface power conditioner. Specifications Foundation Fieldbus with Hawkeye sensors Models Discrete inputs Discrete outputs Operating voltage Current consumption Indication AS-Interface power conditioner Models Connection Max voltage Max current Input voltage JMX04 (2) 6.5 VDC <.045mA, must be low power dry contact capable of operating at <.045mA @ 6.5VDC or solid state pnp capable of operating at 6.5VDC and <1mA (2) 6.5 VDC 2mA. Suitable for StoneL piezo valve 9 to 32 VDC via Foundation Fieldbus voltage <17mA JMX01 and JMX02 (redundant) JMX05 and JMX06 (daisy chain) Redundant inputs (diode protection) Daisy chain inputs (common terminals) 35 VDC 3 amps 26 VDC to 32 VDC Indication Green LED indicates bus power is good (>= 26V) Red LED indicates bus power is low (<26V) AS-Interface repeater Models Operating voltage Operating current JMX00, JMX01 and JMX06 AS-Interface voltage 60mA (per segment) 120mA total AS-Interface cycle time 0.15ms X (AS-Interface slaves +1) Indication Green LED indicates bus power on each segment 1.218.739.5774 144 StoneL.com

Enclosures process networking FieldLink JM specifications and ratings Materials of construction Housing and cover Elastomer seals Fasteners Clear cover Marine grade anodized aluminum with epoxycoating Buna-N Stainless steel Lexan Polycarbonate Enclosure protection NEMA 4, 4X, 6 and IP 67 Hazardous area ratings Class I Groups B, C, D Division 1 and 2 Class II Groups E, F, G Division 1 and 2 Approvals Most models FM approved; CSA approved Dimensions (mm) Standard enclosure Temperature ratings Switched drop connectors, drop connectors, and power conditioners I/O and relay modules I/O w/pneumatic valve Special modules -40 to +80 C (-40 to +176 F) -40 to +80 C (-40 to +176 F) See pneumatic valve section See special modules section Warranty Complete assemblies Two years Switched drop connector enclosure Enclosure with pneumatic valve StoneL.com 145 1.218.739.5774

FieldLink process networking Enclosures Model selector SERIES JM Junction Module FUNCTION Drop connectors Passive T01 AS-i; 1-2 T03 DeviceNet; 1-2 T05 Modbus & Profibus-DP; 1-2 T07 FF-H1 & Profibus-PA; 1-2 Protected P01 FF & Profibus-PA; 1-1 P03 AS-i (240mA); 1-1 D11 (2) FF & Profibus-PA; 1-1 D13 (2) AS-i (240mA); 1-1 P04 DeviceNet; 1-1 (power protected) Switched protected S01 FF & Profibus-PA (40mA); 1-1 S03 AS-i (240mA); 1-1 S04 DeviceNet; 1-1 (power protected) S05 Modbus & Profibus-DP; 1-1 (power protected) PNEUMATIC VALVE 11 No pneumatic valve COVER TYPE C Clear Lexan E Epoxy-coated aluminum CONDUIT ENTRIES 3 (3) 1/2 NPT 6 (3) M20 9 (3) 3/4 NPT Z (3) 1/2 NPT with potted drop leads N (4) 1/2 NPT M (4) M20 T (4) 3/4 NPT Model selector SERIES JM Junction Module FUNCTION I/O modules M92 DeviceNet; 2-DI, 2-DO, 1-AI M93 FF-H1 (bus powered); 2-DI, 2-DO M94 FF-H1 (externally powered); 2-DI, 2-DO, 1-AI, 1AO (select pneumatic valve option 11) M95 Modbus; 2-DI, 2-DO, 1-AI M96 AS-i; 4-DI, 4-DO M97 AS-i; 4-DI, 3-DO (extended addressing) PNEUMATIC VALVE 11 No pneumatic valve 2H 1-Solenoid, 2-position, 5-way, brass 1 2B 1-Solenoid, 2-position, 5-way, stainless steel 1 2L 2-Solenoid, 2-position, 5-way, brass 1 2E 2-Solenoid, 2-position, 5-way, stainless steel 1 3G 1-Piezo, 2-position, 5-way, brass 2 3A 1-Piezo, 2-position, 5-way, stainless steel 2 1 Use with M92, M95, M96 or M97 functions 2 Use with M93 functions COVER TYPE C Clear Lexan E Epoxy-coated aluminum CONDUIT ENTRIES 3 (3) 1/2 NPT 6 (3) M20 9 (3) 3/4 NPT N (4) 1/2 NPT (select pneumatic valve option 11) M (4) M20 (select pneumatic valve option 11) T (4) 3/4 NPT (select pneumatic valve option 11) MODEL NUMBER Partnership ID* MODEL NUMBER Partnership ID* *Some models may include 5-digit suffix for partnership identification. Model number example: JM T01 11 E N (optional) *Some models may include 5-digit suffix for partnership identification. Model number example: JM M93 3G C 3 (optional) 1.218.739.5774 146 StoneL.com

Enclosures process networking FieldLink Model selector SERIES JM Junction Module FUNCTION Relay modules Independent relays R92 DeviceNet; 2-DI, 2-DO (relay), 1-AI R94 FF (externally powered); 2-DI, 2-DO (relay), 1-AI, 1-AO R95 Modbus; 2-DI, 2-DO (relay), 1-AI R96 AS-i; 4-DI, 2-DO, 2-DO (relay) R97 AS-i; 4-DI, 1-DO, 2-DO (relay) (extended addressing) Interlocking relays I92 DeviceNet; 2-DI, 2-DO (relay), 1-AI I94 FF (externally powered); 2-DI, 2-DO (relay), 1-AI, 1-AO I95 Modbus; 2-DI, 2-DO (relay), 1-AI I96 AS-i; 4-DI, 2-DO, 2-DO (relay) I97 AS-i; 4-DI, 1-DO, 2-DO (relay) (extended addressing) PNEUMATIC VALVE 11 No pneumatic valve COVER TYPE C Clear Lexan E Epoxy-coated aluminum CONDUIT ENTRIES 3 (3) 1/2 NPT 6 (3) M20 9 (3) 3/4 NPT N (4) 1/2 NPT M (4) M20 T (4) 3/4 NPT Model selector SERIES JM Junction Module FUNCTION Special function modules X00 AS-i; repeater X01 AS-i; (1) repeater and (1) power conditioner (redundant) X02 AS-i; power conditioner (redundant) X04 FF (bus powered); I/O module with (2) FF Hawkeye point sensors X05 AS-i; power conditioner (daisy chain) X06 AS-i; (1) repeater and (1) power conditioner (daisy chain) 000 empty housing B12 (12) point terminal block PNEUMATIC VALVE 11 No pneumatic valve COVER TYPE C Clear Lexan E Epoxy-coated aluminum CONDUIT ENTRIES 3 (3) 1/2 NPT 6 (3) M20 9 (3) 3/4 NPT N (4) 1/2 NPT M (4) M20 T (4) 3/4 NPT MODEL NUMBER Partnership ID* MODEL NUMBER Partnership ID* *Some models may include 5-digit suffix for partnership identification. Model number example: JM R92 11 C N (optional) *Some models may include 5-digit suffix for partnership identification. Model number example: JM X04 11 C N (optional) StoneL.com 147 1.218.739.5774