Non-conventional instrument transformers Advanced GIS substations with IEC LE process bus

Similar documents
This webinar brought to you by the Relion product family Advanced protection and control IEDs from ABB

Digital Substation Overview of Technology, Industry

POWER GRIDS. We are bridging the gap. Enabling Digital Substations.

Benefits, offering and references

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

Substation Automation Products. Line differential protection RED670 Relion 670 series

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series

Deploying Digital Substations: Experience with a Digital Substation Pilot in North America. Harsh Vardhan, R Ramlachan GE Grid Solutions, USA

ABB Digital medium-voltage switchgear

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

IEEE 1588v2 Time Synchronization in Energy Automation Applications Case Studies from China

Digital substations. Introduction, benefits, offerings

Electrical Integration with Smart Communication

Substation Automation based on IEC Claes Rytoft ABB Power Systems

Automation System Solutions

Jim McGhee, Utility Market Manager, RuggedCom Inc.

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series

How smart can the grid really be?

Digital Substation Unrestricted Siemens AG 2017 siemens.com/digital-substation

Hugo E. Meier, Heidelberg, Germany, June 2014 Integrator Partner Seminar2014 Substation automation trends

Christian Pinzon, ABB Power Grids The power of one solution for distributed busbar protection What s new in Relion REB500 version 8?

Innovation on Medium Voltage Switchgear

We are bridging the gap Enabling Digital Substations

Power Systems Communications Implementation of IEC61850 in a Substation Environment

Alessandro Motta HV Instrument Transformers, Italy>

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

Thiago Lopes Gerente Regional de Ventas Protección, Contról y Comunicaciones.

Products Portfolio. Pole mounted Vacuum Recloser

Relion 630 series. Load-shedding controller PML630 High performing load-shedding solution for industrial and utility power networks

/ Charlie Hsu, Sales, PSAC, Power System Division, TWABB, June.2013 IEC The Approach and the Standard. ABB Group July 1, 2013 Slide 1

The debut of Relion 2.2 The new IEDs generation A suitable portfolio for your digital substation

JULIO OLIVEIRA, ABB POWER GRIDS GRID AUTOMATION, DECEMBER 01 ST ABB Ability - Digital Substations. FISE 7a Edición

ABB AG - EPDS. Gas-insulated switchgear Type ZX2

Trends in Station Bus and Process Bus Communications Via the Several IEC Protocols. Schweitzer Engineering Laboratories, Inc.

Mission Possible Easy Upgradable and Cost-Efficient Distribution Substation

COMMUNICATION NETWORKS. FOX615/612 TEGO1 IEC GOOSE Proxy Gateway interface module.

IEC Edition 2. From substation automation to power utility automation

Performance considerations in digital substations

ABB AG Calor Emag Medium Voltage Products Gas-insulated switchgear Type ZX2. ABB Gas-insulated switchgear type ZX2 1

Content REF615 Technical Presentation

Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation

ABB Substation Automation Products Relion 670 series Ver. 2.0, IEC & ANSI What s new?

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation

Designing a new IEC substation architecture

SPECIAL REPORT FOR STUDY COMMITTEE B5 (Protection and Automation)

Experience with a Digital Substation Pilot in North Ame rica

Bus Bar Protection Relay B-PRO 4000

Grid Automation packaged solutions Optimal automation of medium voltage grids

ELG4125: System Protection

Substation automation products. MicroSCADA Pro for substation automation

Research on Technologies in Smart Substation

Advanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating

IEC meets Industrial IT

Perfect protection smallest space

Grid Automation Controller COM600 How it fits into the Smart Grid?

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power Transformers

ISIO 200. Binary Input/Output (I/O) terminal with IEC interface

EXPERIENCE WITH IEC IN THE REFURBISHMENT OF AN IMPORTANT EUROPEAN 380 KV SUBSTATION. Switzerland

Products for digital substations SIPROTEC 6MU805. Merging Unit for conventional instrument transformer. Integrated PRP, HSR. siemens.

IEC Test Equipment Requirements

DRTS 33. The new generation of advanced three phase relay test set

IEC unites low-and medium-voltage

Utilization of IEC GOOSE messaging in protection applications in distribution network

Protection relays.

Blueprint Data Center

Power Transmission Division Link between power generation and distribution

Impact of Measurement and Communication Aspects on Protection of MTDC Grids

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector

Grid Automation Products. MicroSCADA Pro Substation automation applications.

EPDS Digital Switchgear concepts for MV Applications Take full advantage of IEC and enable digital switchgear

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

ELECTRICAL, INSTRUMENTATION & CONTROL SYSTEMS

FITNESS GB s Pilot Multi-Vendor Digital Substation - Architecture and Design Philosophy

Identify and understand the operation of common bus. After this presentation you will be able to: Identify common bus arrangements

SIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations

Experience with IEC based Systems

Protection, Automation, and Control System. Combine subcycle line protection with complete substation bay control

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Control and Protection System Win-TDC

p. 1 p. 9 p. 26 p. 56 p. 62 p. 68

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

SAFE, FLEXIBLE, EASY CURRENT TRANSFORMER CURRENT TRANSFORMERS FOR THE SAFE MEASUREMENT OF HIGH CURRENTS

Entergy Development and Deployment of IEC Protection and Control Including Process Bus

SIPROTEC 7SC805. Merging Unit for conventional instrument transformer. Products for digital substations.

Grid Automation Products. SAM600 Process Bus I/O System Operation Manual

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)

High and Medium Voltage Substation Design, Testing and Maintenance. KSA, Jeddah, Holiday Inn Jeddah Gateway Hotel.

MicroSCADA Pro Substation automation applications.

Laurent Sowazi, EPMV-DA/ Africa Channel Partner event, 2016 ABB Distribution Automation Making Grids Smarter. ABB November 23, 2016

Jehanpour Ranjkesh, Integrator Partner Seminar 2012 Station level product news Automation Controller COM600

Process Bus overcoming the complexity of process bus adoption to drive down design, implementation and operation costs

Development trends in Substation Design

CONNEX. The Plug-in Connection System for Power Transformers and Gas-Insulated Switchgear. the power connection THE PFISTERER GROUP

Simplifying Protection System Design for Distribution Substations

SEL Time-Domain Link (TiDL ) Technology

Transmission Infrastructure Investment & Development in Vietnam

Relion 605 series. Self-powered feeder protection REJ603 Product Guide

Transcription:

Non-conventional instrument transformers Advanced GIS substations with IEC 61850-9-2LE process bus

Content Towards the digital GIS substations Optimized substation design NCIT for gas-insulated switchgears 2 Non-conventional instrument transformers (NCITs) and IEC61850-9-2LE process bus for GIS substations 3 Transmission substations with NCITs and process bus for sampled analog values 5 ABB s ELK-CP14 and ELK-CP3 non-conventional instrument transformers Protection and control portfolio with IEC 61850-9-2LE 7 Relion 670 series feeder protection and control devices 8 REB500 busbar and breaker failure protection system Protection and control concepts 9 Enhanced substation automation, protection and control systems with IEC61850-9-2LE Technical data 11 The most important technical data of ELK-CP14 and ELK-CP3 and the CP-MU merging units 2 Non-conventional instrument transformers Advanced GIS substations with IEC61850-9-2LE process bus

On the way to digital GIS substations Non-conventional instrument transformers (NCITs) and IEC 61850-9-2LE process bus for gas-insulated switchgear substations By providing complete solutions with IEC 61850-9-2LE 1 process integration, as part of substations with non-conventional instrument transformers (NCIT), ABB proves its market and technology leading position in high-voltage substations and substation automation systems. With more than ten years of in-service experience with NCITs for transmission level applications and the largest installed base of IEC61850 substation automation systems, ABB combines the two technologies in its offerings with NCIT and process bus for sampled analog values. As defined by IEC61850-9-2, sampled analog values are transmitted by so-called merging units (MUs). The MU time correlates and merges analog data from individual phases or measuring points in the substation before transmitting them via the Ethernet network, where the data can be accessed by protection and control devices. In the case of ABB s gasinsulated switchgear (GIS) installations, the merging units receive their data through optical connections from the NCITs. Because this connection is optical, the location of the MU is virtually independent of the cable length. One of ABB s NCIT and IEC61850-9-2LE process bus pilot installations 1 IEC61850-9-2LE is used to denote the implementation guideline for the digital interface to instrument transformers using IEC61850-9-2, published by UCA International Users Group. The guideline describes an application profile of IEC61850-9-2, facilitating implementation and interoperability. The UCA International Users Group is a non-profit corporation focused on assisting users and vendors in the deployment of standards for real-time applications for industries sharing common requirements. Advanced GIS substations with IEC61850-9-2LE process bus Non-conventional instrument transformers 3

Optimized substation design Transmission level substations with NCITs and process bus for sampled analog values Substations are key nodes in transmission and distribution networks. ABB has the specialist knowledge and global experience necessary to build, upgrade and extend substations, wherever they are needed. To optimize the performance of transmission substations ABB has introduced new NCITs and process bus solutions. The ELK-CP series of NCITs, for GIS substations, and process bus solutions, for sampled analog values according to IEC61850-9-2LE, bring the benefits of the most economic and modern technologies. IEC61850-9-2LE is fully integrated in ABB s REB500 and Relion series protection and control devices. The fully redundant, combined current and voltage NCITs and process bus bring multiple benefits, as demonstrated in numerous installations around the world. Enhanced operational safety By replacing conventional current and voltage transformers with non-conventional equipment, operational safety is elevated to new levels. One example is the connecting of NCITs to protection and control devices via fiber optic cables. This isolates the devices from the process and therefore no secondary CT and VT circuits need to be handled. Reduced life-cycle costs and increased availability Permanent real-time system-wide supervision of all electronic components in the complete measuring chain lowers routine maintenance requirements and enables fast and exact fault finding accross the entire station automation, protection and control system. Information on system health can be transferred to remote control and maintenance centers, supporting efficient management and maintenance of resources. 4 Non-conventional instrument transformers Advanced GIS substations with IEC61850-9-2LE process bus

The primary sensor s lifetime and availability goes far beyond those of conventional equipment, especially of voltage transformers. ABB s well-designed and redundant sensor electronics (secondary converter) allow replacement without the need to interrupt power, re-configure or re-calibrate, helping to reduce outage time and increase system availability. The ability to adjust nominal values of the NCIT using software, dramatically reduces the efforts and costs associated with rating changes. Highest accuracy for protection and metering With linear characteristics across the complete measurment range of voltages and currents, ABB s NCITs combine the wide dynamic range required for protection with the high accuracy for metering applications in a single device. The transmission of sampled values according to IEC 61850-9-2LE, through a fiber optic network, guarantees permanently supervised communication that is immune to electro-magnetic disturbances and virtually independent of the cable length. Space-saving design Installing NCITs in place of conventional equipment reduces the total weight of equipment and minimizes space requirements of the switchgear. Reduced copper cabling The optical connections between NCITs and merging units and the fiber optic Ethernet network of the process bus, eliminate parallel copper wiring for current and voltage measurement. This reduces not only the number of copper cables in the substation, it also allows the use of narrower cable trenches. Additional environmental benefits Thanks to the compact design of ABB s NCITs, the required volume of SF 6 gas is considerably reduced. On-site gas handling can also be reduced, because the NCIT can be installed in the factory and it does not need to be dissembled for HV testing. Compared to conventional current and voltage transformers, the NCITs and merging unit suffer lower the power losses in substations and therefore safe energy during their entire life time. Advanced GIS substations with IEC61850-9-2LE process bus Non-conventional instrument transformers 5

NCITs for gas-insulated switchgears ABB s ELK-CP14 and ELK-CP3 non-conventional instrument transformers a b GIS feeder showing two alternative arrangements of the ELK-CP NCIT: (a) after the circuit breaker, and (b) in the cable termination. The features of the ELK-CP14 and ELK-CP3 NCITs are proof of ABB s extensive expertise in the field of highvoltage technology and non-conventional instrument transformers. Fully redundant combined current and voltage NCITs ABB s NCITs are based on two independent sets of Rogowski coils for current measurement and capacitive sonsors for voltage measurement. The redundant measuring path is complemented by two independent, ruggedized sensor electronics, the so-called secondary converters. Integral part of ABB s GIS Designed for ABB s ELK-14 and ELK-3 single-phase encapsulated GIS, the ELK-CP14 and ELK-CP3 are some of the cornerstones of ABB s enhanced NCIT and process bus systems. They cover nominal voltages ranging 170kV to 550kV and nominal currents up to 4,000A. Highest accuracy ABB s ELK-CP14 and ELK-CP3 combined current and voltage sensors feature the highest accuracy and linearity throughout the entire measuring range, supporting protection as well as revenue metering applications. Seamless maintenance The redundant secondary converter (sensor electronics) can be replaced during normal operation with no need for re-calibration or re-configuration. Efficient configuration Software-configurable ratios support efficient design of the switchgear, independent of CT and VT calculations. Configurable current ratings enable future adaptation of CT ratios without needing to replace CT cores or to open gas compartments. 6 Non-conventional instrument transformers Advanced GIS substations with IEC61850-9-2LE process bus

PPL 1 IEC 61850-9-2LE CP-MU The CP-MU merging unit connects up to three 3-phase measuring points IEC61850-9-2 LE compliance certificate Vast experience Over 300 of ABB s ELK-CP NCITs have been in continuous service for more than a decade. This installed base is an invaluable source of experience in the field of non-conventional instrument transformers. The first UCA certified merging unit The merging unit time-correlates and merges sampled values from individual phases and/or measuring points in the substation before transmitting them via the Ethernet network to the protection and control devices. ABB s CP-MU merging unit is the first to be verified by an independent test lab and certified as IEC61850-9-2LE compliant by the UCA International Users Group. The CP-MU follows the IEC 61850-9-2 implementation accoring to the UCA International Users Group s implementation guideline, also refered to as IEC61850-9-2LE One merging unit for ELK-CP14 and ELK-CP3 The CP-MU merging unit is designed for ABB s ELK-CP14 and ELK-CP3 NCITs. It can interface with up to three independent three-phase voltage and current measuring points, allowing for optimal system design with a minimum of components in 1½-breaker- as well as double-busbar-switchgear arrangements. Built-in flexibility The design of protection and control systems can be optimized, thanks to the large number of IEC 61850-9-2LE ports of the merging unit, and the flexibility of sample synchronization. The merging unit can act as time master, where it autonomously generates a 1PPS 2 signal, or it can work as time slave, if the synchronisation is performed elsewhere eg, by a GPS clock. Further more, the merging unit is capable of calculating summated currents from any NCIT inputs and dispatch them via its Ethernet ports to protection and control devices. 1 PPL: Point-to-point link, the optical connection between NCIT and merging unit. 2 1PPS: One pulse per second, used to synchronized sampling by different devices Fit for retrofit Applying non-conventional instrument transformers in substation retrofits simplifies the process and therefore reduces outage times, by avoiding the need to change ratios. Advanced GIS substations with IEC61850-9-2LE process bus Non-conventional instrument transformers 7

Protection and control portfolio Feeder protection and control with IEC 61850-9-2 LE process bus REC670 Bay control Function examples CP-MU MU 1 Local and remote control Interlocking Measurement Backup protection RET670 Group 1 protection Transformer differential protection Overcurrent protection Thermal overload protection Disturbance recording ELK-CP redundant U/I NCIT CP-MU MU 2 RET670 Group 2 protection Overcurrent protection Overvoltage protection Overexitation protection Disturbance recording REB500 Busbar protection Busbar differential protection Breaker failure protection End-fault protection Disturbance recording Conventional parallel wiring IEC 61850-9-2 LE Application example, transformer protection with IEC61850-9-2LE process bus ABB s portfolio of IEC61850-9-2LE compliant protection and control IEDs includes the Relion 670 series of advanced protection and control IEDs, as well as the decentralized REB500 busbar protection system. With these products and systems ABB comprehensively covers all protection and control applications using IEC61850-9-2LE. Relion 670 series protection and control IEDs The Relion 670 series of protection and control IEDs provides versatile functionality, and maximum flexibility and performance to meet the highest requirements in generation and transmission protection systems. Relion 670 series IEDs are: Equipped with functionality specifically required in transmission applications, eg, series compensation and 1- and 3-phase tripping, voltage control, extended disturbance recording, as well as binary and analog data transfer between IEDs Capacity for GOOSE 1 messaging for horizontal communication Equipped with powerful and flexible hardware. The following Relion 670 series protection and control IEDs fully support IEC61850-9-2LE: Bay control IED Line distance protection IED Line differential protection IED Transformer protection IED REC670 REL670 RED670 RET670 For synchronized sampling all IEDs feature a one-pulse-persecond (1PPS) input. All devices support mixed configuration with IEC61850-9-2LE and conventional CT and VT interfaces. This is used, for example, in transformer differential protection applications with NCITs on the high-voltage side and conventional CTs and VTs on the low-voltage side, as shown in the diagram above. Line differential protection runs with both conventional as well as IEC61850-9-2LE-based remote-end substations. 1 GOOSE: Generic object oriented substation event, for the fast exchange of information between IEC61850 servers. 8 Non-conventional instrument transformers Advanced GIS substations with IEC61850-9-2LE process bus

Busbar and breaker failure protection with IEC61850-9-2LE process bus Function examples Busbar differential protection REB500 bay unit REB500 bay unit REB500 bay unit REB500 bay unit Breaker failure protection End-fault protection Disturbance recoding Conventional parallel wiring IEC 61850-9-2 LE REB500 busbar protection system with IEC61850-9-2 LE process bus, combined with conventional CTS and VTs REB500 decentralized busbar protection system REB500 IEDs provide reliable and proven busbar protection for different switchgear configurations. The IEC61850 enabled REB500 IED is designed to support different protection philosophies. Distributed protection solutions with bay units assigned to dedicated bay cubicles are supported, as are integrated solutions where all necessary functionality is contained within a single cubicle. The versatile hardware and distributed functionality of REB500 IEDs enables its application in all types of switchgear configurations, including single-, double- and triple-busbar plus transfer bus-, quadruple-busbar arrangements and 1½-breaker schemes. In addition to low-impedance busbar differential protection, REB500 integrates comprehensive backup protection functionality, including both breaker failure and end-fault protection, reducing both wiring and cabling. REB500 busbar protection system is fully compliant with IEC61850-9-2LE. The seamless combination of bay units with IEC61850-9-2LE and conventional bay units in a single system allows the flexible extensions of conventional substations. Advanced GIS substations with IEC61850-9-2LE process bus Non-conventional instrument transformers 9

SYS 600C Protection and control concepts Enhanced substation automation, protection and control systems with IEC61850-9-2LE Station computer / HMI Maintenance center Remote control center GPS/ Time server Workstation Firewall/ VPN Router/ firewall/vpn Gateway Station LAN Process bus Station bus IEC61850-8-1 Decentralized ring Substation automation, protection and control system with IEC61850 station bus and IEC61850-9-2 LE process bus Extensive experience in high-voltage substations, combined with in-depth expertise in IEC61850 technology make ABB a leading supplier of substation automation, control and protection systems. Building on this sound base, ABB offers complete NCIT and IEC61850-9-2LE solutions for transmission level GIS substations. Worldwide experience substation automation with IEC61850 More than a thousand IEC61850 compliant substation automation systems delivered for new installations and retrofit projects worldwide make ABB the leading provider of enhanced automation, control and protection solutions for substations of all voltage levels. Protection and control concepts, meeting your needs ABB provides safe, reliable and efficient solutions to meet your performance needs and your regulatory requirements. ABB can design protection and control solutions for any voltage level, accommodating a broad range of operational philosophies and different environmental conditions. Enhancing automation, protection and control systems with IEC61850-9-2LE process bus Building on our long experience in substation automation, control and protection, ABB builds complete system solutions with NCITs, IEC 61850-9-2LE process bus and leading-edge protection and control devices. ABB s substation automation systems: more than IEC61850 compliant ABB s advanced station level solutions are designed for maximum safety, efficiency and reliability in local as well as remote control and monitoring of your substation. The solutions benefit from ABB s global presence in this domain, vast expertise in IEC61850 and proven system integration capabilities. 10 Non-conventional instrument transformers Advanced GIS substations with IEC61850-9-2LE process bus

System 1 System 2 Protection and control Metering Metering Protection IEC 61850-9-2LE IEC 61850-9-2LE merging units merging units PPL PPL NCIT protection and metering system 1 on DC supply 1 NCIT protection and metering system 2 on DC supply 2 Full redundancy, from primary sensor to protection and metering Full redundancy across the complete metering, control and protection chain The fully redundancy of ABB s combined current and voltage NCIT is the basis for designing completely independent systems for main 1 and main 2 protection functions. This maximizes system availability by avoiding interdependency between the redundant devices. Permanent supervision of the entire system minimizes maintenance requirements All-embracing supervision of all intelligent components of the complete measuring and automation, protection and control systems allows periodic maintenance activities to be reduced to a minimum. Efficient system design with minimum components Thanks to the number of communication ports available on the merging unit, on both the NCIT and the IEC61850-9-2LE side, efficient solutions can be designed with a minimum of external Ethernet switches in the process bus network. This enables the number of components to be limited and availability is optimized. Safe access to all analog values increases operational safety IEC 61850-9-2LE makes all analog values available on an Ethernet network. For analysis purposes, PC-based tools can simply be connected to the network, eg, to one of the ABB merging unit s numerous Ethernet ports. Once connected, the current and voltage values of all phases are available at once, without touching any CT or VT circuits. Safe process isolation, minimizing outage requirements The distribution of analog values through the process bus Ethernet network allows simple isolation of individual pieces of equipment without disturbing the transmission of current and voltage values to other parts of the substation. This enables more accurate maintenance of individual system components without disruption of service. By replacing of copper cables with optical fibers for the transmission of current and voltage measurements, the secondary equipment can be fully isolated from the primary process, rendering manipulation of CT terminals obsolete. Advanced GIS substations with IEC61850-9-2LE process bus Non-conventional instrument transformers 11

Technical data Non-conventional instrument transformers and merging units Non-conventional instrument transformer ELK-CP3 ELK-CP14 General Highest voltage for equipment (U m ) kv 550 300 Rated lightning impulse withstand voltage (peak) kv 1,550 1,050 Rated switching impulse withstand voltage (peak) kv 1,250 850 Rated frequency (f r ) Hz 50/60 50/60 Measurement bandwidth (-3dB) Hz 1,000 1,000 Rated continuous thermal current (metering) A 4,000 3150 Rated continuous thermal current (protection/control) A 6,300 4,000 Rated short-time thermal current (I th, RMS) ka 63 63 Rated dynamic current (I dyn, peak) ka 170 170 Ambient temperature range C -40 +40-30 +40 Weight kg 250 100 Protection class of housing IP65 IP65 Current measurement (IEC60044-8) Protection data link Rated primary current Ipr (configurable) A (with metering) 100 4,000 100 4,000 A (without metering) 100 6,300 100 4,000 Accuracy class 5P TPE 5TPE Rated extended primary current factor (K pcr ) 1.0 1.0 Rated symmetrical short-circuit current factor (K ssc ) Configuration-dependent Configuration-dependent Rated primary time constant (t pr ) ms 60TPE/120TPZ 60TPE/120TPZ Rated duty cycle No limitation No limitation Metering data link Rated primary current Ipr (configurable) A 100 4,000 100 4,000 Accuracy class for metering 0.2 (0.2S for Ipr > 400 A) 0.2 (0.2S for Ipr > 300 A) Rated phase offset (ϕ or ) 0 0 Rated wake-up time none none Voltage measurement (IEC60044-7) Rated primary voltage U pn (configurable) kv/ 3 330 550 170 300 Protection data link (PPL1) Accuracy class for protection 3P 3P Metering data link (PPL2) Accuracy class for metering 0.2 0.2 Merging Unit CP-MU Number of inputs (PPL) 9 Output interface IEC61850-9-2 Sampling rate (for 50 and 60 Hz) sample/cycle 80 Number of independent measuring points (configurable) 1 3 Rated delay time ms 0 3 Ethernet medium 100BaseFx Ambient temperature range C -5... +55 Protection class of housing IP40 Standards IEC60044-7, IEC60044-8, IEC61850-9-2 1KHA - 001 182 - SEN 1000-05.12 - Printed in Switzerland ABB Switzerland Ltd, May 2012. The right to modifications or deviations due to technical progress is reserved. For more information please contact: ABB Switzerland Ltd Power Systems Bruggerstrasse 72 CH-5400 Baden, Switzerland Phone: +41 58 585 77 44 Fax: +41 58 585 55 77 E-Mail: substation.automation@ch.abb.com www.abb.com/substationautomation