User Guide. TP3016M Series Switching Mode DC Power Supply

Similar documents
User s Manual PROGRAMMABLE DC POWER SUPPLY

User s Manual PROGRAMMABLE DC POWER SUPPLY APS-7303/7303L/7305/7305L

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

3700 SERIES USER MANUAL

80W (16V/5A) Power Supply with USB Output. User Manual

Multiple Output Linear DC Power Supply

Operating Instructions. LSP-KONSTANTER Series 32K Laboratory Power Supply 8/10.13

L300 user manual. Programmable DC Electronic Load CONTENTS. Electronic Load Software CAUTION...2 SAFETY NOTES...2

RIGOL Data Sheet. DP1308A Programmable Linear DC Power Supply. May 2009 RIGOL Technologies, Inc. Product Overview. Easy to Use Design.

USER S MANUAL Linear Programmable DC Power Supply APS

NTP-6621 / 6631 / 6661 SWITCHING MODE POWER SUPPLY with USB REMOTE CONTROL

USER S GUIDE Programmable DC Power Supply Model EA-PSI 6000 Series

Laboratory Switch Mode Power Supply Series. Instruction Manual

LABORATORY GRADE. REMOTE PROGRAMMING SWITCHING MODE DC regulated Power Supplies

Multi-Range Programmable DC Power Supplies 9115 Series

Universal AC Power Source + AC Power Analyzer

LABORATORY GRADE REMOTE PROGRAMMING SWITCHING MODE DC REGULATED POWER SUPPLIES SDP / 3636 / User Manual

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

High Precision Quad Output DC Power Supply

USER S MANUAL DC REGULATED POWER SUPPLY

TC100 Precision Thermocouple Calibrator

USER S GUIDE Programmable DC Power Supply Model IT6322

User's Guide. Model High Precision Quad Output DC Power Supply

Series Watt DC Power Supplies

USER S MANUAL DC REGULATED POWER SUPPLY DIGITAL CONTROL DC REGULATED POWER SUPPLY

User's Guide. Model W 3-in-1 Switching DC Power Supply

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

Agilent E3640A E3649A Programmable DC Power Supplies. Data Sheet

Series 2200 Multichannel Programmable DC Power Supplies User Manual

RIGOL. User s Guide. DP1116A Programmable DC Power Supply. Mar RIGOL Technologies, Inc.

Programmable DC Power Supplies XLN Series

99 Washington Street Melrose, MA Phone Toll Free Visit us at INSTRUCTION MANUAL

TP3005P EN PROGRAMMABLE DC LAB POWER SUPPLY 0-30V/ USB 2.0

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

RIGOL. User s Guide. DP1308A Programmable Linear DC Power Supply. Aug RIGOL Technologies, Inc.

1. Installation. 2. Configuration - Operation. 3. Specifications. Safety

Programmable Digital Controlled DC Power Supplies

Programmable Switching DC Power Supply

HCS-3200/3202/3204 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

PS-5030 (5A) OPERATION MANUAL

ODP Series Linear Programmable DC Power Supply User Manual

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

CALYS 50. Field multifunction calibrator for basic use. Calibration measurement

Model A Mini AC/DC Clamp Meter. User's Guide

I. PANEL DESCRIPTION... 1

PS-1030 (30V) OPERATION MANUAL

Transducers for Pt-100/1000, Resistors

Programmable DC power supplies

Agilent U8000 Series Single Output DC Power Supplies. Data Sheet

Agilent E3640A E3649A Programmable DC Power Supplies

User Manual for Models HG2, HP2, PSM and PSL. Version 1.0. User Manual. June 18, Version 1.0 P/N??? Page 1/17

Operation Instruction For Temperature Simulator

Model R5005. Instruction Manual. True RMS Industrial Multimeter. reedinstruments. www. com

AC/DC TRUE RMS CLAMP METER ACM-2036

SPECIFICATIONS. Input Output Agency Approvals 0 ~ 62.5A. toll-free (603)

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Trend-1 Vibration Data Logger. User Manual

CIRCUIT-TEST. Switching Mode Power Supply with USB Remote Control PSC VDC / 5A PSC VDC / 3A PSC VDC / 1.

1-36V, 0-3A DC Power Supply

360W and 720W Programmable DC Power Supplies

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Instruction manual Wattmeter CLM1000 Standard

USER MANUAL. RND 320-KA3000 Series

Multi-Range DC Power Supply

V /06/ Velleman nv

DP700 Series. Programmable Linear DC Power Supply. Batter Fly s.r.l. - Tel

Keysight U8030 Series Triple-Output DC Power Supplies

PQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES

-auto Power Off- T1/T2/T1-T2

ODP3031 Linear Programmable DC Power Supply User Manual

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 658 MULTI-OUTPUT DC/DC CONVERTER POWERED BY 2-CELL, USB OR WALL ADAPTER

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply PSC-6118 PSC-6136 PSC A 5A 2.5A

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Model DCP42 160W Laboratory Grade Constant Power, Switching Mode Power Supply

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

LVDT Test Device. Product Manual (Revision B) Original Instructions. Testing and Calibration of LVDT Feedback Devices on PG Governors

OPERATING INSTRUCTION

ODP Series Dual Output Linear Programmable DC Power Supply User Manual

SPECIFICATIONS: PSAK650

Optima OP-900-LD Score Board Indicator (with Remote Control) User Manual

1 INSTRUCTION 2 SPECIFICATIONS 3 USER GUIDE 1. Output voltage 0-32V Output current. 0-1A( CA19101DH) 0-3A( CA19103DH) 0-5A( CA19105DH) Source effect

AC Power Sources. APT...The Power of Value! NEW! 300XAC Series. Manual Automated - Modular. Modular AC Power Sources. Automated AC Power Sources

Operation Instruction For RTD Calibrator

Programmable Dual-Range DC Power Supplies 9170 & 9180 series

Single-output and dual-output power supplies. TOE 8840 up to 160 W TOE 8850 up to 320 W. In-phase regulation

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

Programmable Dual-Range DC Power Supplies 9170B & 9180B Series

midi LOGGER 220 GL220-UM-251

midi LOGGER 200 SERVICE MANUAL GL200-UM-251 GL200-UM

HI-POT TESTER. User s Manual

FG-7000 Digital Force Gauge Operation Manual

Industrial Power Supplies

OPERATING INSTRUCTION. Pen-Type Digital Multimeter

MC 11 EB-2 Power supply cabinet with external bus, AC version

TH2683 Insulation Resistance Meter. User s Mannual

E36300 Series Triple Output Bench Power Supply DATA SHEET

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

1. Chapter 1 24/48/110/220VDC Power Supply System

1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6.

Transcription:

User Guide TP3016M Series Switching Mode DC Power Supply 1

Introduction I. Quick Start 1.1 Front Panel Description 1.2 Pre-Checking 1.3 Quick Start 1.4 Output Checking II. Specifications 2.1 Major Specification 2.2 Supplementary Characteristic III. Operation 3.1 Keypad 3.2 Front Panel 3.3 Voltage Setting 3.4 Current Setting 3.5 Output Switch 3.6 Data Saving Operation 2

3.7 Recall Saving Operation 3.8 USB Power Charging IV. Calibration 4.1Voltage Calibration 4.2 Current Calibration 3

Introduction Thank you for selecting the TP3016M Switching DC Power Supply, please read this user guide before the operation. Safety This manual contains important safety and operation instructions for correct use of power supply. Read through the manual and pay attention to the markings and labels of this unit to be connected. Do not install the substituted spare parts or operate the modification without permission, please send the unit back for A/S to our authorized dealers or factory for guaranty of the stability of the unit. Pay special attention to the information of WANRINGS or CAUTIONS to avoid the damage to power supply or connected equipment and human injured. Please contact the trained technicians for repair service. Safety Marks WARNING: 4

Failure to observe this warning may cause injury to persons and damage to power supply or connected equipment. CAUTION: Failure to observe this warning may result in damage to equipment and improper functioning of power supply. Grounding High Voltage Attention on the Warning or Caution Specification Compliance TP3016M Switch mode DC Power Supply is compliance with the specification described in this manual. The content or specification of this manual is subject to change, without prior notice. Product Features 5

TP3016M is the single output switch mode DC power supply with max. 30V output voltage, 1.6A output current and max. output power as 50W. TP3016M is integrating the AC/DC and DC/DC 2nd level voltage regulator technology, the AC/DC input is adapting the worldwide voltage range. The DC/DC is using the synchronous buck mode, which with the high efficiency and high speed dynamic response performance. TP3016M can be set the voltage and current through the keypad of front panel and save the setting groups for further performance. TP3016M also has the 4 digit voltage and current meter, as well as the fantastic handheld size. The TP3016M is perfect for solving a variety of loading conditions and applications. Please find the following main features of TP3016M: Handheld design Without noise of fan 4 digits LCD display Output short circuit protection High speed dynamic response Once power cut-off, automatically protect under power off status The output has the automatic recognition of USB charging port Can be calibrated via software operation 6

I. Quick Start This chapter describes the basic check points on TP3016M for making sure the proper operation, as well as the functions of TP3016M. 1.1 Front Panel Description 1 Current Setting Indicator 2 Voltage Setting Indicator 3 Measured Value Display 4 Keypad 5 USB Charging Ports 6 DC Output Terminals 7

1 2 3 4 5 6 8

1.2 Pre-Checking Before the operation, please check the accessories are fully included, if any missing, please contact the local distributor. Power Cord 1PC (Compliance with the standard voltage of the region) User Guide 1PC Connect with power and switch on TP3016M, the unit start the self-system checking, the LCD displays 0.5s, date of manufacturing, production lot, model number version number in turn. 1.3 Quick Start OUT Button Press and light OUT button, the power supply is under output status and read the measuring value of voltage or current in the display. Press again OUT button to exit output function. 9

UP Arrow Key + DOWN Arrow Key Press UP arrow key to activate the LCD backlit Press DOWN arrow key to exit the LCD backlit LEFT Arrow Key + RIGHT Arrow Key Press LEFT arrow key to decrease the contrast of LCD Press RIGHT arrow key to increase the contrast of LCD V/A Key Press the V/A key to activate voltage measurement and read the voltage value from display. Push the V/A key again to switch current measurement and read the current value from the display USB Button Push and light the USB button and adjust voltage to 5.2V and the current as 3A to enter USB 10

power charging mode; then, push and light the OUT button, the TP3016M is working as power charger. Push the USB button again and USB button lights out to exit USB power charging mode. SET Button + V/A Button + Direction Arrow Keys Push the SET button, by pressing the direction arrow keys to adjust the voltage value setting, Push the V/A button to switch the current value setting mode, by pressing the direction arrow keys to measured current value. 1.4 Output Checking 1.41 The output voltage regulation mode check This is for checking the functions of power supply under non-load voltage stability. 1) Switch on the product, the power is off and the indicators of CC & CV are light off. 11

2) Push and light the OUT button, the indicator of CV is light on at LCD display. 3) Setting the voltage of power supply Push the V/A button and shift to voltage display mode, adjust various voltage values then, check the voltage value displayed at LCD is approaching the settled voltage value and within the tolerance, current value is showed as 0A. 4) Make sure the voltage can be adjusted from 0.5V to max. 30V. 1.42 The output constant current mode check This is for checking the functions of power supply under constant current mode. 1) Switch on the product, the power is off and the indicators of CC & CV are light off. 2) Adjust voltage value as 30V. 3) Connect the resistance (3Ω/50W) between output terminals. 4) Push and light the OUT button, the indicator of CC is also light. 5) Setting the current of power supply Push V/A button and shift to current display mode, adjust various current values, then, check the current value displayed at LCD is approaching the settled current value and within the tolerance. 6) Make sure the current can be adjusted from 0A to the max. value. 1.43 The output short circuit protection check This is for checking the function of short circuit protection of output. 12

1) Switch on the product, the power is off and the indicators of CC & CV are light off. 2) Adjust voltage value is over 5V and current value is over 1A. 3) Push and light the OUT button. 4) Connect the output terminals by wire for short circuit, the light of OUT button is off and output off. 1.44 The USB charging function check This is for checking USB charging function. 1) Switch on the product, the power is off and the indicators of CC & CV are light off. 2) Push and light the USB button. Adjust the voltage as 5.1V and current as 2.0A. 3) Push and light OUT button. 4) Make sure the power supply under CV mode, the CV indicator is light in LCD. 5) Setting the current value and make sure the current value can be adjusted from 0A to the max. value of measuring range. Do not adjust voltage. II. Specification 2.1 Major Specification 13

Input Voltage Input Current Output Rating Line Regulation ±%of output + offset Load Regulation ±%of output + offset Measurement Accuracy Measured Value Accuracy @ 25 ±%of output + offset Measurement Speed Setting Value Accuracy @ 25 ±%of output + offset Ripple and Noise 20HZ-20MHZ Temperature Coefficient @ 0~40 ±%of output + offset Dimensions Weight (Net) 110AC~ 60Hz 1A Voltage range Current range Voltage Current Voltage Current Voltage Current Voltage Current Voltage Current Voltage Current Voltage Current Voltage Current 185x88x38 mm 370g 0.5V~30V 0~3.75A CV 0.01%+3mV CC 0.01%+3mA CV 0.02%+3mV CC 0.02%+3mA 10mV 1mA 0.05%+5mV 0.05%+5mA 100ms/ones 100ms/ones 0.05%+5mV 0.05%+5mV 10mVrms/100mVp-p 10mVrms/100mVp-p 0.05% 0.1% 14

2.2 Supplementary Characteristic Build-in EEPROM Recommended Calibration Time:1 Time/Year AC Input Power: 110VAC, 60 Hz Operating Temperature: 0 to 40 Storage Temperature: -20 to 70 III. Operation Check the rating label of the power supply and ensure that it complies with the AC mains voltage that is to be used. Connect the power supply to the AC minas using the provided power cord. 3.1 Keypad Description OUT V/A USB Output check Voltage & Current Shift 5V Cell Phone Charging 15

SET/ENTER STORE/RECALL UP DOWN LEFT RIGHT Voltage & Current Setting/Enter Data Saving/Recall Direction Arrow Keys 3.2 Front Panel After power on, the panel operation mode is the default setting of power supply and all the functional buttons can be operated. 3.3 Voltage Setting The voltage setting range is from 0.50V to 30V; follow the setting steps as below: 1. Switch on the power supply 2. Push the OUT button to stop the output setting and light off OUT button 3. Push and light the SET/ENTER button, the max. value position is flickering of voltage setting area 4. Push the LEFT or RIGHT arrow keys to move the cursors 5. Push the UP or DOWN arrow keys to change the settings 6. Push SET/ENTER button and light off this button to exit voltage setting mode UP ENTER OUT SET 00.00 V ------------- >3 0.00 V ---------------> OK 16

Remark: I. It is possible to set voltage values once the outputs are valid. However, for protection of the load, it is recommended to stop output before voltage setting. II. Due to the total power limit, current settings might be decreased automatically once voltage setting increasing. 3.4 Current Setting The current setting range is from 0.000A to 1.66A, follow the setting steps as below: 1. Switch on the power supply 2. Push the OUT button to stop the output setting and light off OUT button 3. Push and light the SET/ENTER button, the max. value position is flickering of voltage setting area. 4. Push the V/A button, the max. value position of current setting is flickering and current setting is activated 5. Push the LEFT or RIGHT arrow keys to move the cursors 6. Push the UP or DOWN arrow keys to change the settings 7. Push SET/ENTER button and light off this button to exit current setting mode 17

UP ENTER OUT SET V/A 0. 000 A ---------> 2.000 A ------------ > OK Remark: I. It is possible to set current values once the outputs are valid. However, for protection of the load, it is recommended to stop output before current setting. 3.5 Output Switch Under the panel operating mode, by pushing OUT button to shift output status. Once OUT button lighted, the measured values displayed at LCD; push OUT button again to exit output mode. 3.6 Data Saving Operation 1. Under the voltage setting or current setting mode, push the STORE button to save the values of voltage or currents into memory of power supply for future recall purpose. (as below steps) 2. Refer 3.3 or 3.4 for voltage or current setting mode. 3. Push STORE button to enter data saving mode, the min. value position is flickering and displayed STORE icon in LCD. 4. Move UP or DOWN arrow keys to select storage group serial number. 5. Click ENTER button to confirm data saving, click STORE button to exit data saving mode. 18

UP SET STORE 1 2 ENTER -----> OK 3.7 Recall Saving Operation Under the panel operating mode, push the RECALL button for getting the saved data from memory; follow the setting steps as below: 1. Switch on the power supply 2. Push RECALL button to enter data recall mode, the min. value position is flickering and displayed RECALL icon in LCD. 3. Move UP or DOWN arrow keys to recall the stored group serial number, the default values from voltage or current setting mode displayed in LCD. 4. Click ENTER button to confirm data recall, click STORE button to exit data recall mode. UP RECALL 1 2 ENTER --------> OK 19

3.8 USB Power Charging Push the USB button and light the green indicator, the default setting is voltage @ 5.1V and current @ 2.0A, the LCD will display 5.1V, current value also can be as 0A. Connect the mobile phone via USB cable for power charging. The USB ports are suitable for both android mobile phone and l Iphone, with automatic check function, the product can set the proper charging current automatically. 1. Push and light the OUT button to activate output mode. 2. Push the USB button and USB indicator is off to exit USB charging mode. USB OUT OK 20

IV Calibration Follow the below chart, connect the 5 digit displayed volt meter, current meter, resistance (10Ω/100W) into the output terminals, calibration follow the steps start from point of zero voltage - voltage coefficient current zero current coefficient. 5 6 Hold the SET button to switch on power supply till REF displayed in LCD to enter calibration mode. 21

4.1 Voltage Calibration At the power supply displayed 2.000A & 05.00V in setting area of LCD and **.**V displayed in main part of LCD. Connect the output terminal with an external reference voltage meter and shift to CV mode. Hold the LEFT or RIGHT arrow keys to move the cursors to left or right and push the UP or DOWN arrow keys to adjust the values same as readings of external reference voltage meter, then click ENTER button to finish the voltage bias calibration. At the power supply displayed 2.000A & 30.00V in setting area of LCD, hold the LEFT or RIGHT arrow keys to move the cursors to left or right and push the UP or DOWN arrow keys to adjust the values same as readings of external reference voltage meter, then click ENTER button to finish the voltage gain calibration. 4.2 Current Calibration Push the V/A button and power supply displayed 0.500A & 20.00V in setting area of LCD and *.***A displayed in the main part of LCD. Connect the output terminals with the external reference current meter and the load (6Ω/100W), shift to CC mode. Hold the LEFT or RIGHT arrow keys to move the cursors to left or right and push the UP or DOWN arrow keys to adjust the values same as readings of the external reference current meter, then click ENTER button to finish the current bias calibration. 22

At the power supply displayed 3.000A & 20.00V in the setting area of LCD, hold the LEFT or RIGHT arrow keys to move the cursors to left or right and push the UP or DOWN arrow keys to adjust the values same as readings of external reference voltage meter, then click ENTER button to finish the current gain calibration. Push OUT button to exit and restart the power supply to complete the calibration function. 23