Belimo ZoneTight TM QCV 2-way characterised control valves and 3-way change-over ball valves. Table of Contents. Notes for project planning

Similar documents
BELIMO ENERGY VALVE. Transparent energy monitoring with the Belimo Cloud.

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Products no longer available

Functional data Factory settings Variable Setting Torque Inhibiting torque

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

Technical data sheet

Radiator Valves. Building Technologies HVAC Products. NF norm, for 2-pipe heating systems

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Ready for the volumetric flow systems of tomorrow.

Power consumption In operation At rest For wire sizing

3-PORT SEAT VALVES PN16 WITH EXTERNALLY THREADED CONNECTIONS STAZ-16, STBZ-16, STCZ-53 DATASHEET

Technical data sheet. Technical data

Technical data sheets

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Overview of types. Technical data

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

Brief description. Type overview

Brief description. Type overview

Products no longer available

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

Electrical Actuators

Electrical Actuators

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

Rotary actuator for ball valves KNX / PL-Link

Belimo Gateway MP to Modbus RTU - UK24MOD

C200 VALVE WITH UM ELECTRIC ACTUATOR

Radiator Lockshield Valves ADN.. AEN..

VAV system solution for non-pressure dependent applications in enclosed spaces

Functional data Position indication reflective visual indicator (snap on) Communicative control Cloud: (call for clientapi )

s Spring return C / max C

Control system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication

A 101 A B C. Variable flow-control valve, series DXC. Dynamic Flow Networking. Description. Content

Electrical Actuators

Control engineering information VARYCONTROL VAV Units VAV Compact flow rate controller BC0 BF0

Rotary actuators for ball valves

Belimo Gateway MP to Modbus RTU - UK24MOD

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

B 201 A B C. dynamx variable flow-control valves, series DXMB_C. Dynamic Flow Networking. Description. Content

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Control equipment EMBL

Electromotoric actuator

Installation VAV-Compact Retrofit Set

Control equipment EMBL

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

Technical data. PRCA-BAC-S2-T en-gb subject to changes 1

5/2 and 5/3 Directional-control valves, Series TC 15, G 1/4

Differential pressure sensor For ventilation and air-conditioning Model A2G-50

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

M3P..G/A, M3P..F/A Modulating control valves (PN16) for chilled and hot water systems

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Thermal Mass Flowmeter Sensyflow FMT200-D

Wall-mounted Heat Interface Unit HIU Instantaneous domestic hot water production Mechanical control

Electromotoric actuators

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

SideControl Positioner

Belimo Gateway MP to LONWORKS - UK24LON

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

2-PORT SEAT VALVES PN16 WITH FLANGED CONNECTIONS STAZ-16, STBZ-16, STCZ-52 DATASHEET

NOVAZONE BALL MOTOR-DRIVEN BALL VALVE ADVANTAGES. Control of volume flows for different fluids in HVAC systems SYSTEM/BASIC DIAGRAM

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

SPCH/ Big bottle blowing block

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

Application program: description and examples

Fast running actuators for air dampers

Bus solutions from Belimo. The best connection.

Belimo Energy Valve Communication Document

Electrical actuators

Actuator ABNM A5 LOG/LIN for AB-QM, 0-10 V Proportional

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

Digital Positioner 8049

Room Temperature Controllers

FANCOIL CONTROLLER UNIT TC17B01KNX. Product Handbook

Temperature sensors and accessories for heat and cooling measurement points

Belimo Energy Valve Solving Low Delta T Leveraging IoT.

Operating instructions. Standstill monitor A / / 2011

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

Brief description. Service tool ZTH, PC-Tool service socket: locally pluggable or via PP connection.

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Desigo RXA Room controllers without bus communications Range overview. CA2S3880en_ Building Technologies

Product information. Technical data. Safety notes. Definitions

RA Electric Rotary Actuator 20 Nm to 60 Nm for butterfly valves

BUS. Adaptive control system for pressure applications (STP) Table of contents

Temperature Controller

QUICK-START EMU M-BUS CENTER ENGLISH

Electromotoric actuators

Communicative controller for VAV systems

FCU-4 FAN COIL CONTROLLER

A 602 A B C. dynamx flow-control valves, series DXN6_B. Dynamic Flow Networking. Description. Content

Type Electrically Actuated 3-way Ball Valves

T EN TROVIS Electropneumatic Positioner

Immersion Temperature Sensors

Electric Actuators with Process Controllers

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Transcription:

Belimo ZoneTight TM QCV -way characterised control valves and -way change-over ball valves Table of Contents Introduction Type key Product features Adjustable angle of rotation k v setting Adaption Operating range Selection and dimensioning Selection table for -way characterised control valves Calculation diagram for -way characterised control valves Table of dimensions for -way change-over ball valves www.belimo.com -way zone valve-qcv en 0.0 Subject to changes /

Notes for project planning Introduction, type key and product features Introduction The valve-actuator combination QCV (= Quick Compact Valve) is a Belimo ZoneTight TM Room & Zone Solution. The QCV, comprised of the -way characterised control valves and the -way change-over ball valves of the nominal sizes DN and DN 0 and the CQ... actuators, have impressive properties: Tight-sealing ball valve prevents circulation losses Minimum power consumption during operation and in standby mode Compact overall structure Lightning-fast manually adjustable flow rates with the -way characterised control valves Automatic adaption to the set k v value Rotary valves protected against soiling and seizing thanks to form-fit valve-actuator connection Actuator installed without any tools Compatible with V, 0 V, open-close/-point, modulating control and MP-Bus. Type code Valve C Q - J Actuator CQ C K A - SR - T C = Compact, internal thread = Internal thread, -way characterised control valves = Internal thread, -way change-over ball valves = External thread, -way characterised control valves = External thread, -way change-over ball valves = DN 0 = DN 0 Q = Actuator installed without any tools H = Flow rate value range... m /h J = Flow rate value range... m /h K = Flow rate value range.7... m /h F = Flow rate range 0... m /h CQ = Compact, low torque C = No details: running time 7 s C = Running time s D = Running time s K = Actuator with emergency control function (SuperCap) = AC/DC V / 0 = AC 0 V A = New actuator generation SR = No details: open-close, -point SR = Modulating control, operating range...0 V SZ = Modulating control, operating range 0...0 V MPL = Belimo MP-Bus light T = Version with clamp Product features Adjustable angle of rotation The rotary actuator can be changed in. increments with the use of a clip. This is used to set the k v value (maximum flow rate of the valve). k v setting Remove end stop clip and put into desired position (without end stop clip k vs value of the valve ). Each time the kv setting is changed using the end stop clip, with the modulating actuators an adaption has to be triggered. N Adaption Push button Press button: Switches on angle of rotation adaption, followed by standard mode No N Adaption When the supply voltage is switched on for the first time, i.e. at the time of commissioning, the CQA-SR(-T), CQA-SZ(-T) and CQA-MPL(-T) actuators with modulating control carry out an adaption. This also has to be done when the end stop clip is adjusted. / -way zone valve-qcv en 0.0 Subject to changes www.belimo.com

Product features Product features Position number CQ.. actuators N ) ) CQ-F k v [m /h] 0.09 0. 0. 0. 0. 0.7. CQ-J k v [m /h] 0. 0...9. C0Q-K k v [m /h] 0. 0.9...9.7 CQ-J k v [m /h] 0. 0...9..7. C0Q-K k v [m /h] 0. 0.9...9.7 7. ) without end stop clip ) factory setting Operating range The ball valve has an operating range in its direction of opening of...90 as a result of its design, which means that the air tight range with the ball valve is at. A hysteresis of also is obtained as a result of the design, which means that the ball valve is not air bubble tight in the direction of closing until it reaches. At the smallest k v value that can be set (Position number ), the angle of rotation of the ball valve is still.. This means that the actuator adapts to the angle 0..., of which is the air tight range, meaning % at this flow value setting. If the actuator has the operating range 0...0 V (for 0... ), then the effective operating range of the valve is between. and 0 V. The running time of the actuator is 7 s / 90, i.e. this results in a running time of 0 s for the. at the Position number setting. The operating ranges of the valves with the respective position numbers are: Modulating control actuators CQA-SR(-T) Operating range DC...0 V CQA-SZ(-T) Operating range DC 0...0 V Position number CQ.. actuator Completely open position at [ ] Running time [s] Combination operating range in the direction of opening [V] Number of control steps Combination operating range in the direction of opening [V] Number of control steps. 0...0...0 7 7.7...0 70.7...0....0 7...0 90 9 9.0...0 0.9...0 9....0...0 9 7...0...0 0 N....0 7...0 0 ) 90 7...0 9...0 0 ) without end stop clip Calculation of actuator control steps: Operating range (e.g..... 0 V) 0 V. V =. V Response sensitivity: 7 mv = 0.07 V Actuator control steps:. V / 0.07 V = 7 steps Opening limit angle (tight not tight): approx. in the direction of opening Hysteresis combination:... Closing limit angle (not tight tight): approx. in closing direction Running time of actuators: 7 s / 90 Recommendation for the smallest k v values (Position numbers and ): The QCV should not be used with a P controller (persistent control deviation) The QCV should be used only in a closed control loop with PI or PID control In case of doubt, use the QCV only as an open-close unit For special applications, the 0 V version of the open-close, -point actuator can be used with a running time of s (CQC0A) or s (CQD0A). www.belimo.com -way zone valve-qcv en 0.0 Subject to changes /

Selection and dimensioning Selection table for -way characterised control valves Permissible working pressure p s Max. differential pressure p max Medium temperature 00 kpa 0 kpa...90 C Valve Actuator CQ-F CQ-J C0Q-K CQ-J C0Q-K Position No. CQ.. actuator CQA-SR(-T) CQA-SZ(-T) CQA(-T) CQ0A(-T) CQA-MPL(-T) CQKA(-O) CQKA-SR(-O) CQC0A CQD0A Valve design Valve characteristic curve k v k v k v k v k v 0.09 0. 0. 0. 0. 0. 0. 0.9 0. 0.9 0... kv 0..... H 0..9.9.9 0.7.9..7.7.7 N... 7. ) DN 0 0 internal thread ISO 7- - external thread - ISO - ) without end stop clip / -way zone valve-qcv en 0.0 Subject to changes www.belimo.com

Selection and dimensioning Calculation diagram for -way characterised control valves DN Application These characterised control valves are used in closed cold and hot water systems for modulating water-side control of air handling units and heating systems. Media Medium temperatures Cold and hot water, water with glycol up to max. 0% vol....90 C p v00 [bar] 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0. 0. 0. 0. 0. 0. 0. 0 0. 00 [m /h] 0 0. 0. 0. 0. DN kv.0..0..7..9. 0.7 0. 0...9.0....7.. 0. 0. 0. 0. 0.7 0. 0. 00 [l/s] 0. 0. 0. 0. 0. 0. 0. 0.09 pmax 0.0 0.0 0.0 0 0 0 0 0 0 p v00 [kpa] 0 00 00 00 00 00 00 00 000 p max Maximum permissible differential pressure for long service life across control path A AB, with reference to the whole opening range. p v00 Differential pressure for ball valve opened up to k v value setting 00 Nominal flow rate with p v00 Formula k v k v [m /h] 00 [m /h] p v00 [kpa] k v = 00 p v00 00 www.belimo.com -way zone valve-qcv en 0.0 Subject to changes /

Selection and dimensioning Calculation diagram for -way characterised control valves DN 0 Application These characterised control valves are used in closed cold and hot water systems for modulating water-side control of air handling units and heating systems. Media Cold and hot water, water with glycol up to max. 0% vol. Medium temperatures...90 C p v00 [bar] 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0. 0. 0. 0. 0. 0. 0. 0 0. 0 0 7. DN kv 0.0 0.7 0.0...7.. 0. 00 [m /h] 0. 0. 0. 0. 0. 0. 0. 0.9 0. 0 0. 0 0.9 0. 0. 0. 0.7 0. 0. 0.0 0.0 00 [l/s] 0. pmax 0.0 0 0 0 0 0 0 p v00 [kpa] 0 00 00 00 00 00 00 00 000 p max Maximum permissible differential pressure for long service life across control path A AB, with reference to the whole opening range. p v00 Differential pressure for ball valve opened up to k v value setting 00 Nominal flow rate with p v00 Formula k v k v = k v [m /h] 00 [m /h] p v00 [kpa] 00 p v00 00 Table of dimensions for -way change-over ball valves Differential pressure p max [kpa] Flow rate 00 [m /h] 0..0.0 0.0 k vs [m /h] DN [mm] connection 0.0 0. 0. 0.. CQ-H internal thread 0. 0. 0.9. 0 C0Q-J internal thread 0.07 0. 0. 0.7. CQ-H external thread 0. 0. 0... 0 C0Q-J external thread Formula 00 k vs [m /h] 00 [m /h] p v00 [kpa] 00 = k vs pv00 00 / -way zone valve-qcv en 0.0 Subject to changes www.belimo.com

www.belimo.com -way zone valve-qcv en 0.0 Subject to changes 7 /

All-inclusive. -year warranty On site around the globe A complete range of products from one source Tested quality Short delivery times Comprehensive support Belimo Europe BELIMO Automation AG Brunnenbachstrasse CH-0 Hinwil, Switzerland Tel. + Fax. + info@belimo.ch www.belimo.ch Belimo worldwide: www.belimo.com