Laser Calibration Check

Similar documents
TABLE OF CONTENTS Introduction For Your Safety Components How to Use the Laser System Powering the Laser Turning On/Off the Laser Turning On/Off the

TABLE OF CONTENTS Introduction For Your Safety Components How to Use the Laser System Powering the Laser Turning On/Off the Laser Laser Setup

TABLE OF CONTENTS Introduction For Your Safety Components How to Use the Laser System Powering the Laser Turning On/Off the Laser Laser Setup

Operating Instructions TPL 50 HV

HV101. Руководство пользователя

TABLE OF CONTENTS Introduction For Your Safety Components How to Use the Laser System Powering the Laser Turning On/Off the Laser Laser Setup

TEL: / FAX:

Operating Manual. AdirPro HV8RL Red Beam Horizontal/Vertical Laser level

LAR 350 rotation laser: Tough DUAL SLOPE laser kit Made in Germany. World s first MOTION CONTROL

Laser Operations Guide

GL622/GL612 GL622/GL Kellenburger Road Dayton, Ohio , USA USA Phone

Instructions. Remote Controlled Rotator RCR

Instruction Manual. Electronic Horizontal & Vertical Self-Leveling Rotary Laser Level Model Nos , ,

Auto-leveling Rotating Laser (RL430G)

UL 633 UL Dayton, Ohio

QUAD 1000 OWNERS MANUAL OPERATION GUIDE

Self-leveling Laser Marker (4V1HXL)

LA 90L / LA 180L. Operating instructions

Self-Leveling Cross Line Laser Level with 3 Vertical Lines Model No Instruction Manual

from P.R.Engineering Ltd Tel:

LS516/LSG516 Self-leveling Rotating Laser Instruction Manual ( )

Dear user, Thank you very much for purchasing LS533H rotary laser. Please read this instruction manual before operating it.

Instruction Manual. Electronic Self-Leveling Dual Grade Horizontal / Vertical Rotary Laser Model No

HV601/HV602 for General Construction

Aligning Continuous Casters and Steel Mill Rolls

Centralite CT Moving Laser Patient Positioning System (MRR-1)

LINE LASERS Product Guide

Leica DISTO X3 Designed for tough, rugged conditions

Leica Lino Accurate, self-levelling point and line lasers

Machine Tool Alignment Boring Mills, Gantries, Machining Centers, VTLs

Leica Rugby CLA & CLH. The first upgradable lasers. Built to transform. leica-geosystems.com

Primus-H. Primus-HV. Primus-HVA. Precise surveying and measuring. Made in Germany

CE 260 SURVEYING CHAPTER 5 THEODOLITES

862 PROLASER CROSS LINE LASER

ECOLINE EL 515 PLUS EL 515 PLUS SET

Laserliner. Innovation in Tools. MultiBeam-Laser MBL 3. Bedienungsanleitung Operating instructions Gebruiksaanwijzing

MultiBeam-Laser MBL 5

Rotary Laser Service Manual

Mk II 3DR MULTI-LINE LASER INSTRUCTION MANUAL

2LS products are high quality positioning. tools that bridge the gap between. do-it-yourself laser gadgets and industrial

Tripods, levelling ling staffs and fasteners

How to use Leica DISTO D510

Geometry Measurements

USER GUIDE. Differential Thermometer Datalogger. Model HD200

LAR 350. Operating Instructions.

Geo3X HP BEDIENUNGSANLEITUNG USER MANUAL MODE D EMPLOI

Laser Rotators. Ready for the most challenging sites

If ( ) is approximated by a left sum using three inscribed rectangles of equal width on the x-axis, then the approximation is

NEDO X-LINER SERIES. Dot and line lasers for interior finishing X-LINER SERIES

Experiment 6. Snell s Law. Use Snell s Law to determine the index of refraction of Lucite.

What s So Great About RF Technology?

1. PRECAUTIONS. Thank you for choosing RUIDE theodolite Disteo 23. Please read this manual carefully before use.

1. Safety instructions

LSL250. Laser light! Do not stare into the beam or view directly with magnifiers. Class 2 laser EN :

The world s most versatile pipe laser

How to use Leica DISTO X310

Greenline-Laser 3P / 5P

LINE LASERS Product Guide

Portable equipment N130/N330 QUICK GUIDE BASIC OPERATIONS

Study Guide and Review

Spectra Precision. Laser DDS300/DD300-1 Depth Display System USER GUIDE

Instruction Manual EN

Single-Axis Lasers for Flatness and Leveling Applications. Laser Systems for Flatness and Leveling L-730/L-740 Series

Alignment Software for Linear Guides

The Nureva Span ideation system. Installation guide. Single panoramic system

Instruction Manual EN

DG813 RC803 SF803 DG613

Chapter M01: Measuring Devices for Distances, Heights, Moisture, Temperature

Measuring systems. Measuring Systems. Hilti. Outperform. Outlast.

Leica 3D Disto PROJECTOR function for stair case applications

DE EN FR. S-Digit multi + BEDIENUNGSANLEITUNG USER MANUAL MODE D EMPLOI

Further Information can be found at

Receiver REC 300 Digital. Operating instructions

Module 7 Defining Coordinate Systems

E D I T I O N PRODUCT LIST SURVEY PRODUCTS LTD

The FaroArm. The world s best-selling measurement arm

Standard Equation of a Circle

Theodolite Instructions

O T Rotating Laser Target System.

User s guide. November LSE S.r.l. All rights reserved

Rotary laser for outdoor areas

Three-Dimensional Laser Scanner. Field Evaluation Specifications

Agilent 10706B High Stability Plane Mirror Interferometer

POINT & LINE LASERS Product Guide

Construction. Product Guide

Leica DISTO X4 Designed for bright, outdoor environments

HOW TO SETUP RAPSODO BASEBALL? A QUICK USER GUIDE

Measurement solutions. for construction and surveying.

Waiting Room Network Installation Manual

USER MANUAL. Turbine Blade Tip-to-Casing Cold Clearance. Wireless Measurement Kit CMS Model

Leica Geosystems Construction Products The right tools for any site

VZ series Camera Calibration

Leica Rugby 810, 820 & 840 The toughest construction lasers on site

Green Rotary Laser Level

Laser measuring tools and surveying equipment

12 Feb 19. Images and text courtesy of John Bean, University of Virginia

MultiLine Please read these instructions before operating the product. 5 - Beam Self-Leveling Multi-Line Laser

11.0 Measurement of Spindle Error Motion

Solving with Seesaws

CLLi Please read these instructions before operating the product. 2 - Beam Self-Leveling Cross Line Laser

Transcription:

Laser Calibration Check Checking Calibration of the Y- and X-Axes 1. Set up the tripod 15 m (50 ft) from a wall and make sure the tripod head is leveled. 2. Attach the laser to the tripod with the handle pointing into the opposite direction of the wall. Note: Make sure that all three plastic or rubber feet are touching the tripod head. 3. Turn on the laser and allow it to level. Note: Let the laser run for 5 minutes to warm up the leveling system. 4. If the green LED starts flashing every 4 seconds, the calibration check can be performed.

Laser Calibration Check 5. Raise/lower the receiver until you get an ongrade reading for the +Y axis. 6. Using the on-grade marking notch or the flat surface on top (right above the photocell) as a reference, make a mark on the wall. Note: For increased precision, use the finesensitivity setting (1,5 mm//1/16 in.) on the receiver. In order to avoid wrong markings caused by the deadband of the receiver, always adjust the receiver to the on-grade position coming from the same side (bottom or top)!

Laser Calibration Check 7. Rotate the laser 180 (-Y axis toward the wall) and allow the laser to re-level. Note: Make sure that all three plastic or rubber feet are still touching the tripod head. 8. Raise/lower the receiver until you get an ongrade reading for the Y axis and make a second mark on the wall. 9. The distance between the two marks (Y1 and Y2) determines the calibration error. If they differ more than 3 mm//1/8 in. (HV101/LL100) at 15 m (50 ft), the laser needs calibrating on the Y-axis. ------------- Y2 >3 mm (>1/8 in.) ------------- Y1 10. After checking the Y-axis, rotate the laser 90. Repeat the above starting with the + X axis facing the wall. 11. When made the mark for the +X axis, rotate the laser again 180 (-X axis toward the wall) and allow the laser to re-level. Make the next mark at the wall and check the difference between the two X axis marks.

HV101 Entering the Service Mode For best result, place the unit on a level platform or a leveled tripod to begin calibration. The unit must be leveled on both X- and Y-axes before proceeding to calibration mode. Turn the unit on and allow it to level, then turn it off after both axes are leveled. 1. To get the unit into service mode make sure the unit has been turned off. HI/Man-LED Level-LED Rotation button 2. Press and hold the Power and then press and release the Rotation two times 3. Release the Power in less than 1 second after the Rotation button has been released. Note: The unit is now in the service mode. Note: All LEDs start flashing once a second to confirm the service mode has been entered. Battery-LED Power

HV101 Calibration Procedure (X-Axis) The unit must be leveled on both X- and Y-axes and has to run in rotation mode with 600 rpm before proceeding with calibration mode. 1. To get the unit into X-axis calibration mode, press and release the Up button at the laser or remote control. (Laser beam is off, the battery LED is flashing in a rate of 2 seconds.) After starting the X-axis calibration mode, the compensator will drive from the current position to one end of the X-axis limit then back to the other and stop at the center position. (Laser beam is flashing until the rotor stops at the center position, then the beam is on.) Wait 10 seconds until the unit starts the rotation (600rpm). Now you can start calibrating the unit. 2. To have access to the calibration change, press and release the rotation button (Laser beam is on, battery LED is on). Up Arrow Battery-LED Rotation Power

HV101 Calibration Procedure (X-Axis) 3. To correct a calibration error, mark a new line at the midpoint of the distance between the first and second readings of the X-axis, and calibrate the unit to that point pressing repeatedly the Up and Down buttons on the laser or the remote control. Up and Down Arrow 4. If the beam has been adjusted correctly, press and release the rotation button at the laser or remote control (laser beam turns off, unit needs four seconds to check and store the new calibration data). If the calibration was inside the calibration range, the unit goes back to the service menu (laser beam off, all LEDs flash). If the laser beam and the battery LED flash two times a second, the unit is outside of the field calibration range and can only be calibrated at an authorized service center. ------------- X2 correct ------------- X1

HV101 Calibration Procedure (Y-Axis) Note: If calibration is not required, press and release the power button and the previous calibration value will be maintained. 1. To get the unit into Y-axis calibration mode press and release the Down button at the laser or remote control. (The laser beam is off, the battery LED is flashing in a rate of 2 seconds.) After starting the Y-axis calibration mode, the compensator will drive from the current position to one end of the Y-axis limit then back to the other and stop at the center position. (Laser beam is flashing until the rotor stops at the center position, then the beam is on.) Wait 10 seconds until the unit starts the rotation (600rpm). Now you can start calibrating the unit. Down Arrow Battery-LED Rotation Power 2. To have access to the calibration change, press and release the rotation button (Laser beam is on, battery LED is on).

HV101 Calibration Procedure (Y-Axis) 3. To correct a calibration error, mark a new line at the midpoint of the distance between the first and second readings of the Y-axis, and calibrate the unit to that point pressing repeatedly the Up and Down buttons on the laser or the remote control. Up and Down Arrow 4. If the beam has been adjusted correctly, press and release the rotation button at the laser or remote control (laser beam turns off, unit needs four seconds to check and store the new calibration data). If the calibration was inside the calibration range, the unit goes back to the service menu (laser beam off, all LEDs flash). If the laser beam and the battery LED flash two times a second, the unit is outside of the field calibration range and can only be calibrated at an authorized service center. ------------- Y2 correct ------------- Y1

Laser Calibration Check (Z-Axis) Checking Calibration of the vertical (Z-Axis) on HV101 To check vertical calibration, you need a plumb bob with at least 10m (30 ft) of string. 1. Suspend the plumb bob from the ceiling of a room whose ceiling height is at least 10m (30 ft). 2. Set up the laser in vertical so that the laser beam strikes the top of the string. Stop the beam s rotation. 3. Using the left/right arrow button, guide the beam from the top of the string to the bottom of it. 4. Look for any deviation in the beam from the top of the string to the bottom of it. If the deviation is more than 2 mm (3/32 in.), the vertical axis needs calibrating.

HV101 Calibration Procedure (Z-Axis) Note: The unit must be setup vertical and leveled on the Z-axis and has to run in rotation mode with 600 rpm before proceeding to calibration mode. 1. To get the unit into Z-axis calibration mode press and release the Scan button at the laser or remote control. (The laser beam is off, the battery LED is flashing in a rate of 2 seconds.) After starting the Z-axis calibration mode, the compensator will drive from the current position to one end of the Z-axis limit then back to the other and stop at the center position. (Laser beam is flashing until the rotor stops at the center position, then the beam is on.) Wait 10 seconds until the unit starts the rotation (600rpm). Now you can start calibrating the unit. 2. To have access to the calibration change, press and release the rotation button (Laser beam is on, battery LED is on). Scan Battery-LED Rotation Power

HV101 Calibration Procedure (Z-Axis) 3. To correct a calibration error, mark a new line at the midpoint of the deviation between the top and bottom of the string readings of the Z-axis, and calibrate the unit to that point pressing repeatedly the Up and Down buttons on the laser or the remote control. 4. If the beam has been adjusted correctly, press and release the rotation button at the laser or remote control (laser beam turns off, unit needs four seconds to check and store the new calibration data). If the calibration was inside the calibration range, the unit goes back to the service menu (laser beam off, all LEDs flash). If the laser beam and the battery LED flash two times a second, the unit is outside of the field calibration range and can only be calibrated at an authorized service center. Up and Down Arrow

HV101 Calibration Procedure (X, Y, Z) Note: If calibration is not required, press and release the power button and the previous calibration value will be maintained. Note: Calibration may be performed with the stopped or rotating beam (dynamically). The unit can be calibrated dynamically with the last set rotation speed (rotation speed when unit was powered down from normal operation mode). Note: The calibration procedure can be done in the field by a trained customer but our preference is that calibration should be performed at the service center!