/ Patch Cord Fusion Splice point Boot Life-span: 15 years Maintenance-Free Economical Patch Cord Discover the difference, Unlike any other!
Field installable Fusion Splice-on Connector Ilsintech's high quality, low cost Fusion Splice-on Connector (SOC) has become a most mo s Polarization-maintaining (PM) single mode optical Jumperr cords d reliable solution to terminate the fiber out in the field for FTTH outside plant. lant. ant. can be used in a number of applications, including high speed optical transmission nsmission The has a factory pre-polished ferrule and it requiress no epoxyy and systems, interferometric sensors, LN modulators, DFB-LD, instrumentations ns and polarization no field polishing. And the utilizes Swift series of the fusion splicers, sensitive components. such as F1, F1 Plus, S3, and S5 to terminate the connector, and it is compliant with Telcordia GR-326-CORE. SC, LC, FC and ST connectors are available for and/or applications. Applications - In accordance with IEC61754-2/4/13/20, KS C6974 (F04), JIS C5973 (F04) - FTTH, CATV, FTTx - Compliant with Telcordia GR-326-CORE - Data center installation - Directly splicing with drop cable and Indoor cable - Central office cable management - PANDA (Fujikura) +LJK 3UHFLVLRQ $[LV $QJOH Û - High Extinction Ratio - Scratch Free for End-face - Spliced point is protected in the Connector, no extra splice fixtures required - Enhanced high quality with improved optical features ( and return Loss) Connector Key - Enhanced and improved high tensile strength - Satisfies Vertical Burn Test. Materials Compliant with UL94V-0 Stress Applying Parts Core Average Cladding Multi Mode Single Mode PC SC, LC, FC, ST SM 9/125um $YJ G% 0D[ G% 50 60 NJI IRU PP EXIIHU NJI IRU PP FRUG DQG GURS &DEOH Mating Durability &\FOH G% FKDQJH -40 ~ 75 Cable 0.9mm, 2.0, 2.4, 3.0mm Cord, Indoor cable(2mm x 3mm) Structural Feature frame Housing Spring Boot Splice point Heat shrinkable sleeve Unit Screw cap 2.0~3.0mm, indoor cable(2mmx3mm) Splicing FC, SC Measurement Wavelengths: SM Light Source LD, Wavelength 1550nm, Master cord Measurement MM Light Source LD, Wavelength 1300nm, Master cord Measurement bush Fast Axis - Tensile Strength Stop ring Slow Axis MM (OM1, OM2, OM3, OM4) Extinction Ratio mm 7\S 0D[ 0D[ 50 60 Typ. 30 Typ. 30 Max. 25 Max. 25 Types PANDA 1300, PANDA 1550 (0.25, 0.9, 3.0) Polarization Axis Options Slow, Fast Key Options R (Reduced), N (Wide) -20 ~ +70 Storage Temperature a
Comparison CO Mechanical & Pre-terminated Cord 1:N OLT 10~20Km CONNECTORS MECHANICAL CONNECTOR Connection Method Permanent connection by fusion splicer Temporary connection by V-groove method Operation Time 2~3 minute 2~3 minute above Application FTTH, GE-PON, G-PON, WDM-PON G-PON, WDM-PON Lift span Permanent (15 years above) Shorter life span (3~5 years) Dust, dirt, lower connectivity Cost Low Middle Insert Loss () 0.2 below (avg.) 0.5 below () : 50 / : 60 : 40 / : 50 Transmission Speed Up to 2 Gbps Below 100 Mbps Tensile Strength NJI IRU 3.0mm cord and drop Cable 3N (0.3kg above) Disadvantages Remark - Fusion splicing - Best quality, Fast connection - Low cost - No expensive equipment - Required fusion splicer (recover investment within one year) - Training for operation - Short life - Skilled labor required - cleaver required - Korean government: 1 Gbps at 2012 (Giga Korea) - EU, USA, Japan: Adopt fusion splicing connector ONU 1~2Km MDF DP Underground Splice Closure CO OLT ODF 6Km 1~2Km DP 1:N 1:N Telcodia-GR -326 1:N 2Km Swift F1 /ONU Premise FTB FWS OLT : Optical Line Terminal ODF : Optical Distribution Frame : Distribution Center DP : Drop Point, Demarcation Point Fusion Splice Point < 0.05(Swift F1) Connector < 0.2 (FTTH SOC) Advantages MDU FTB : Termination Box FWS : Wall Distribution Socket ONU : Optical Network Unit : Optical Network Terminal Applications ODC / OTP / Deployment - Solution +LJK 'XUDELOLW\ ĺ +LJK 3URWHFWLRQ +LJK 4XDOLW\ ĺ /RZ /RVV - Save Installation Cost - Neat & well organized Using pigtail Connector Using Splice trays and protection sleeves are not necessary, which in turn keeps the space neat and open. Comparison: with Mechanical Connector 1. Lower installation cost. - More than 50% cheaper than other fusion splice-on connectors (SOC) and same or lower than mechanical connector. The best quality at low price. OTP mounted splitter Data Center 2. Best transmission quality - The quality of fusion splice-on connectors have been verified as the best way in transmission sector (Backbone Network). ex) Swift connector insertion loss= 0.2 below (average), mechanical connector, insertion loss = 0.5 3. Very low Maintenance Cost 6SOLFH RQ FRQQHFWRU /LIHVSDQ LV DSSUR[LPDWHO\ \HDUV RU PRUH NJI RI 7HQVLOH 6WUHQJWK - Mechanical connector: Lifespan: 3~5 years. 0.3kgf (3N) of Tensile Strength. Because of drying of matching gel, maintenance service should be required within a year. Before After With, it is very easy to maintain uniformity and tidiness. 1. Neat & well organized 2. Cost save/competitive price - Reduced maintenance cost - No need special cabinet for extra cable storage - Reduced cable cost (G.657) 3. Possible to adopt patch cord maintenance - No need to replace patch cord
Applications TENSILE STRENGTH - Low (Typical 0.2) - Transmission systems - High - CATV, LAN systems - Scratch Free for End-face - Test Equipments - Telcordia GR-326 issue-3 compliance - Module Pigtailing Over 60N Over 15 years - Meet the requirements of TIA-EIA-604-X Unit Perfect Solution with ALLINONE splicer + 50 60 Radius of Curvature mm 7~25 5~12 Apex Offset Protrusion or undercut nm -50 ~ +50-100 ~ +100 Angular offset Û N/A Comparison with the others Vs Mechanical Connector SM or MM Types -40 ~ +75 Storage Temperature a QUALITY 250 1550mm Average=0.12() S.D=0.07() 150 100 100 0 0 () 0.40 - High tensile strength (60N above) - Double-protected splicing point - 25% lower than Mechanical Connector - Installation Cost (FTTH SOC + Swift Splicer < Mechanical Connector) - No maintenance required TASK DIFFICULTY 53.0 54.0 55.0 56.0 () 57.0 QUALITY - Optimized loss rate (Pigtail has bending loss issue) - Permanent life span (More than 15 years) 50 0.30 1550mm Average=55.1() S.D=0.47() 150 50 0.20 1310mm Average=54.92() S.D=0.56() 200 Frequency(N) 200 Frequency(N) 250 1310mm $YHUDJH G% S.D=0.07() Vs Pre-terminated Cord (Pigtail) - Low insertion loss (less than 0.2) COST 0.10 Budget-priced SC, LC, FC, ST 0.00 INSTALLATION COST Maintenance-free LIFE-SPAN COST - Similar cost but no extra cost (Pigtail needs extra sleeve, cassette) - Installation cost (FTTH SOC < Pre-terminated cord) - Pigtail needs extra protection at splicing point, this means pigtail is vulnerable to external environment. TASK DIFFICULTY - No skilled labor required - Easy work and best performance with Swift fusion splicers - No extra tools needed - No extra tools needed - Operation time : within 2 minutes - Operation time: within 2 minutes
www.ilsintech.com www.ilsintech.com Copyright 2014 Co., Ltd. All rights reserved. This product or document is protected by copyright and distributed under licenses restricting its use, copying and distribution. No part of this product or document may be reproduced in any form by any means without prior written authorization of Co., Ltd. Products shown on this catalog are subject to change at any time without any prior notice for improvement purpose.