XI Signal-to-Noise (SNR)

Similar documents
MRI Physics II: Gradients, Imaging

White Pixel Artifact. Caused by a noise spike during acquisition Spike in K-space <--> sinusoid in image space

MRI image formation 8/3/2016. Disclosure. Outlines. Chen Lin, PhD DABR 3. Indiana University School of Medicine and Indiana University Health

Lab Location: MRI, B2, Cardinal Carter Wing, St. Michael s Hospital, 30 Bond Street

Midterm Review

Role of Parallel Imaging in High Field Functional MRI

Imaging Notes, Part IV

Exam 8N080 - Introduction MRI

Diffusion MRI Acquisition. Karla Miller FMRIB Centre, University of Oxford

Steen Moeller Center for Magnetic Resonance research University of Minnesota

Sparse sampling in MRI: From basic theory to clinical application. R. Marc Lebel, PhD Department of Electrical Engineering Department of Radiology

MRI Imaging Options. Frank R. Korosec, Ph.D. Departments of Radiology and Medical Physics University of Wisconsin Madison

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

Accelerated MRI Techniques: Basics of Parallel Imaging and Compressed Sensing

Clinical Importance. Aortic Stenosis. Aortic Regurgitation. Ultrasound vs. MRI. Carotid Artery Stenosis

(a Scrhon5 R2iwd b. P)jc%z 5. ivcr3. 1. I. ZOms Xn,s. 1E IDrAS boms. EE225E/BIOE265 Spring 2013 Principles of MRI. Assignment 8 Solutions

SIEMENS MAGNETOM Avanto syngo MR B15

Applications Guide for Interleaved

Magnetic Resonance Angiography

Lucy Phantom MR Grid Evaluation

Fast Imaging Trajectories: Non-Cartesian Sampling (1)

SIEMENS MAGNETOM Avanto syngo MR B15

CHAPTER 9: Magnetic Susceptibility Effects in High Field MRI

3D3C & 2D3D Velocity Measurements Using Magnetic Resonance Velocimetry

Compressed Sensing for Rapid MR Imaging

Fmri Spatial Processing

M R I Physics Course

Edge Detection (with a sidelight introduction to linear, associative operators). Images

SIEMENS MAGNETOM Verio syngo MR B15V

Breast MRI Accreditation Program Clinical Image Quality Guide

Paul's Online Math Notes Calculus III (Notes) / Applications of Partial Derivatives / Lagrange Multipliers Problems][Assignment Problems]

Basic fmri Design and Analysis. Preprocessing

The SIMRI project A versatile and interactive MRI simulator *

Phase Difference Reconstruction. Outline

Diode Lab vs Lab 0. You looked at the residuals of the fit, and they probably looked like random noise.

Central Slice Theorem

Field Maps. 1 Field Map Acquisition. John Pauly. October 5, 2005

COBRE Scan Information

Fast Imaging UCLA. Class Business. Class Business. Daniel B. Ennis, Ph.D. Magnetic Resonance Research Labs. Tuesday (3/7) from 6-9pm HW #1 HW #2

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2006

G Practical Magnetic Resonance Imaging II Sackler Institute of Biomedical Sciences New York University School of Medicine. Compressed Sensing

A Virtual MR Scanner for Education

Compressed Sensing And Joint Acquisition Techniques In Mri

SIEMENS MAGNETOM TrioTim syngo MR B17

Is the statement sufficient? If both x and y are odd, is xy odd? 1) xy 2 < 0. Odds & Evens. Positives & Negatives. Answer: Yes, xy is odd

FMA901F: Machine Learning Lecture 3: Linear Models for Regression. Cristian Sminchisescu

CS1114 Section 8: The Fourier Transform March 13th, 2013

Improved Spatial Localization in 3D MRSI with a Sequence Combining PSF-Choice, EPSI and a Resolution Enhancement Algorithm

surface Image reconstruction: 2D Fourier Transform

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

Functional MRI in Clinical Research and Practice Preprocessing

An Introduction to Image Reconstruction, Processing, and their Effects in FMRI

A Transmission Line Matrix Model for Shielding Effects in Stents

Module 4. K-Space Symmetry. Review. K-Space Review. K-Space Symmetry. Partial or Fractional Echo. Half or Partial Fourier HASTE

Electrical Circuits and Random Walks

ARRAY COMBINATION FOR PARALLEL IMAGING IN MAGNETIC RESONANCE IMAGING

Parallel Imaging. Marcin.

SPM8 for Basic and Clinical Investigators. Preprocessing. fmri Preprocessing

1. Techniques for ill-posed least squares problems. We write throughout this lecture = 2. Consider the following least squares problems:

Dynamic Image and Fieldmap Joint Estimation Methods for MRI Using Single-Shot Trajectories

Following on from the two previous chapters, which considered the model of the

MR Advance Techniques. Vascular Imaging. Class III

Use of MRI in Radiotherapy: Technical Consideration

SIEMENS MAGNETOM Skyra syngo MR D13

BME I5000: Biomedical Imaging

Theoretically Perfect Sensor

Digital Image Processing. Prof. P. K. Biswas. Department of Electronic & Electrical Communication Engineering

Introduction to Homogeneous coordinates

EPI Data Are Acquired Serially. EPI Data Are Acquired Serially 10/23/2011. Functional Connectivity Preprocessing. fmri Preprocessing

K-Space Trajectories and Spiral Scan

Theoretically Perfect Sensor

A Model-Independent, Multi-Image Approach to MR Inhomogeneity Correction

Sampling, Ordering, Interleaving

New Technology Allows Multiple Image Contrasts in a Single Scan

TOPICS 2/5/2006 8:17 PM. 2D Acquisition 3D Acquisition

Biomedical Image Analysis. Spatial Filtering

SFU CMPT Lecture: Week 8

INTRODUCTION TO ALGEBRAIC GEOMETRY, CLASS 6

SIEMENS MAGNETOM Verio syngo MR B17

Lossy Coding 2 JPEG. Perceptual Image Coding. Discrete Cosine Transform JPEG. CS559 Lecture 9 JPEG, Raster Algorithms

Electrical Circuits and Random Walks: Challenge Problems

Super-resolution Reconstruction of Fetal Brain MRI

Edges, interpolation, templates. Nuno Vasconcelos ECE Department, UCSD (with thanks to David Forsyth)

Scan Acceleration with Rapid Gradient-Echo

Sampling, Ordering, Interleaving

General and Efficient Super-Resolution Method for Multi-slice MRI

Vector Calculus: Understanding the Cross Product

Administrivia. Next Monday is Thanksgiving holiday. Tuesday and Wednesday the lab will be open for make-up labs. Lecture as usual on Thursday.

(Refer Slide Time: 0:38)

Drawing a Triangle (and an introduction to sampling)

This Time. fmri Data analysis

MATH 423 Linear Algebra II Lecture 17: Reduced row echelon form (continued). Determinant of a matrix.

Statistical Analysis of Image Reconstructed Fully-Sampled and Sub-Sampled fmri Data

The Concept of Sample Rate. Digitized amplitude and time

Evaluations of k-space Trajectories for Fast MR Imaging for project of the course EE591, Fall 2004

SPM8 for Basic and Clinical Investigators. Preprocessing

Digital Volume Correlation for Materials Characterization

Fourier Transforms and Signal Analysis

Inverse and Implicit functions

Transcription:

XI Signal-to-Noise (SNR) Lecture notes by Assaf Tal <n > n(t) <n> t. Noise. Characterizing Noise Noise is a random signal that gets added to all of our measurements. In D it looks like this: while in D it looks like the snow on your TV screen: In well behaved systems, the mean of the noise is ; it sometimes gets added and sometimes gets subtracted from our signal at random. When <n> is non-zero the signal is said to be biased. Bias is easy to detect and remove, so we won t focus on it here, and will assume the mean of our noise is. The variance of our noise is basically its size. When the variance of the noise becomes as large as the signal being measured, it becomes extremely hard to discern the two. Ideally, we would like to make the variance as small as possible. In practice, we often settle for making it small enough ; that is, small enough with respect to the signal we re looking at, so as to make the features that interest us discernable. This chapter will mostly be devoted to ways of making the noise s variance small enough.. Signal to Noise Ratio (SNR) As noted before, noise gets added to every signal we measure. Noise is unavoidable. It comes from resistive elements in our system: the electronics, and even the patient who has some finite resistance. Microscopically speaking, it is because of the thermal fluctuations of our system: in the electronics and of the spins in the patient. A noise signal, n(t), cannot be represented by an analytical function. To characterize noise, we need to speak in statistical terms. The two most important characteristics are the mean (also known as the average) and the variance of the noise. They are denoted by <n> and <n >, respectively, and are illustrated below: Noise Noisy Signal + Signal The signal to noise ratio of the noisy signal is defined as:

magnitude of signal SNR var iance of noise If the signal changes considerably from point to point, so will the SNR. In other words, the SNR is a function of position (if we re dealing with images) or time (if we re dealing with time signals). For example, take a look at this function: - 5 5 8 6 4 5 5 4 6 8 - Now we add some random noise to it: 8 5 5 6 4-4 6 8 The SNR of the first few steps is much lower than the SNR of the last few steps. A low SNR means the noise is big and will make it hard for us to determine the magnitude of the signal accurately, or even see the signal. A high SNR means the noise is small. Measuring the SNR in practice can be tricky. The best thing to do is to find some region in your signal/image where you know there s only noise, and to use it to estimate your noise s variance. 5 5 - and here is their sum:.3 Adding Noise Suppose you have several noisy, independent random signals, with the same variance, and you add them together. What will be the variance of the sum? Let s do a little experiment. Here are four random signals: - 5 5

You can observe visually that the variance of each individual noisy signal is about.5, and the variance of the sum is about. So, while we ve added 4 random signals, we didn t increase the variance by a factor of 4. In fact, we ve increased it only by a factor of 4. This is a general fact about random signals: Adding N random signals, each having the same variance, X, will yield a random signal with variance NX. I will not prove this fact in these notes. Intuitively, though, expecting an increase by a factor of N is unreasonable, because the noise sometimes adds constructively and sometimes destructively. This leads to a corollary: Adding N measurements improves the SNR by a factor of N. This is because the signal multiplies by N, the noise s variance by N, and their ratio by N : signal N scans N signal SNR N SNR noise Nnoise This is sometimes also called signal averaging..4 Noise in MRI A well known theorem from statistical mechanics (the so-called Nyquist theorem) states that, the variance in the voltage in an electronic system is given by V 4kTR Joules 3 where k.38 is Boltzmann s Kelvin constant, T is the temperature of the system (in Kelvin), R is the its resistance (in Ohms) and is the range of frequencies we re observing. For a typical D MRI experiment, where we acquire in the presence of a gradient G read, G FOV: read Spins here precess w/ frequency G FOV Object FOV G FOV What is R? There are two sources of resistance in an MRI experiment: The RF coils (R c ). The patient (R p ). Both the coils and the patient are conductors, to a degree. When a magnetic field infringes upon a conductor it dissipates partially as heat. We are basically made out of water, which is a conductor. When a magnetic field tries to penetrate a conductor it creates eddy currents as it dissipates slowly. This is known as the skin effect. The currents induced in the patient then induce currents in the coils that are picked up as noise. This is called patient loading. It turns out that for high fields (~ Tesla and above in practice), patient loading is more important than the intrinsic hardware noise. Calculating a patient s resistance is difficult and usually not very constructive, so we will simply treat it as a constant. The only important fact is that it is (approximately) proportional to the square of the main field: B. So p c p RR R R CB. where C is some constant, whose value will be assumed unknown. It can be calculated, but it will not serve our purpose (which is inferring how changing the experimental parameters will affect the SNR). To sum up: G z Spins here precess w/ frequency G FOV read read V 4kTCB G FOV

Note I ve added the read subscript, to emphasize that the range of frequencies we observe during acquisition is determined by the read gradient (and not, say, the slice selection or phase-encoding gradients)..5 Fourier Transforming Noise The MRI signal is measured in k-space and consequently Fourier transformed to yield an image. The Fourier transform of noise is just... more noise. Don t forget our FT is discrete: it s carried over a finite number of points. Because every point in the original (k-space) function affects every point in the Fourier (image) space, this means the noise at some point r in our image is added up from all points in k-space. If we have a total of N points in k-space, then the variance of the noise in image space will increase as N. However, the discrete Fourier transform also has a factor of /N in its definition. Without going into the technical details, here is the bottom line that s relevant for us: Fourier transforming noise over a discrete set having N points decreases its variance by N. This works in D and 3D as well. For a D grid having N x points along the k x axis and N y points along the k y axis, the noise s variance will decrease by a factor NN x y.. SNR In MRI. Relative SNR FT Being able to calculate the absolute SNR might be interesting theoretically but quite formidable, because the noise will ultimately depend on the hardware, patient, and image. Rather, one looks at how the SNR changes as we change the imaging parameters: the resolution, voxel size, FOV, acquisition time, gradients, B (not really a parameter, but still interesting), etc. This is precisely what this section is all about.. Signal We ve spent the last section talking about noise, but haven t said anything about signals. We ve remarked how the finite sampling in k-space (k max ) causes blurring in the signal, so the signal at point r is actually an average of the signal in a voxel around it: r voxel r r r I M ' d ' M V centered around r where V is the size of the voxel. Remember the in front is there because of Faraday s law (the signal is proportional to the time derivative of the magnetization, which is proportional to. See chapter, section 3.).. SNR In 3D Imaging Here is a 3D GRE sequence: Rec RF G x G y G z -y TE Suppose we ve: TR ACQ. T s Gradient Spoiling

. Collected N x, N y and N z points along the k x, k y, k z axes.. Have a voxel size V=xyz (note the voxel doesn t have to be a cube, i.e., x isn t necessarly equal to y or z, etc). 3. Because we re reading along the x-axis, we have a bandwidth of GFOV x x. 4. The readout time along x is T s (see sequence above). 5. We acquire the same image N acq times (for signal averaging). Then Using we get SNR r r signal noise M r V N acq NNN x y z N k N kfov N x x x x s x Gx GxFOVx T N t SNR r M r V N zn yn acqt s The SNR of a 3D scan (assuming read is along the x-axis) This is also valid for 3D spin-echo imaging..3 SNR In D Imaging D imaging is just like 3D imaging, with one omission: you don t sample along the 3 rd dimension. Rather, you use a slice-selective gradient. Let s take the slice-selective direction to be z, with x & y being the read & phase axes, respectively. This means that we need to omit N z from the above expression, because we re not Fourier-transforming over that direction. Furthermore, note that V, the voxel s volume, has a thickness equal to the slice s thickness along the z-axis (let s call it naturally z): 3D r r SNR M V N N T D y acq s SNR In terms of SNR, 3D imaging is superior to D imaging. Should we always use 3D? That depends. 3D often requires more scans to achieve the same slice thickness, to avoid aliasing (you need smaller k s to cover the entire FOV along the 3 rd axis; in D imaging, you don t care about aliasing because you re selectively exciting a slice and imaging all of it). Another problem is ringing artifacts having to do with the Fourier reconstruction. As a rule of thumb, for thick slices (a few mm and above), you should go for D imaging. For thin ones (~ mm and thinner), go for 3D. There are also other, phenomenon-specific reasons for going D; in MR time-of-flight angiography sequences, for example, slowly flowing blood yields better contrast in sliceselective, rather than 3D, imaging..4 SNR Dependence on B One thing the above equations don t show is the dependence of the SNR on B. Recall that, for high fields (which interest us), while noise~ V ~ B B signal ~ (one comes from M, the other comes from the Faraday s law: the signal we acquire is proportional to the time derivative of M xy ~e i t.) Hence: B B SNR B ~ B The SNR should increase linearly with the field. In practice, this is only approximate. N z z Thus: