FT Flexitest Family. Switches, Covers and Test Plugs

Similar documents
FT & RT Test Switches

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

Elastimold Molded Vacuum Recloser - MVR

Occupancy and Vacancy Sensors ROOM CONTROLLER* DAYLIGHT SENSOR WPP-INT INSTALLATION GUIDE

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Rack- and Panel-Mount Power Distribution Units (PDUs)

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Document C0. Use for:

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

SAX / PAX Test Blocks & Probes

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

FTS / FTP Test Blocks & Plugs

Rack- and Panel-Mount Power Distribution Units (PDUs)

Power Distribution. For technical support call Online catalog available at leviton.com 461

The Center of Automation with IEC Products. CENTERLINE Motor Control Center. Allen-Bradley Replacements

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching

SSV-T and SSC-T High Drop-out Relay. Range amps amps amps amps. Operating Frequency: Temperature Error:

Model 7705 Control Module

Safety Test Switch. Reference Handbook. STS-reference-en v

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

Miniature Circuit Breakers and Supplementary Protectors. Contents

Smart-UPS APC Smart-UPS 750VA USB & Serial RM 1U 120V

Instruction Manual Basic Rack PDU VP7541 and VP9571A

Agilent E3640A E3649A Programmable DC Power Supplies. Data Sheet

Breaker Panel Technical Practice NPDRP1114

ALPHA Plus and A3 ALPHA Switchboard Meters with the CPS Power Supply

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

Replacing the Power Supply

C-POWER AC AUTOMATIC CONTROL

IEC H.P. Rated Pin and Sleeve Sequential contacts engagement during mating and un-mating IEC configurations specific to each voltage and

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

The Leviton Load Center THE FUTURE MADE CURRENT

Bulletin Installation of solar photovoltaic systems Rules , , , , and

Line Impedance Stabilization Network (LISN)

ITS / STP Test Blocks & Plugs

MULTIPOWER MANUAL. Designed and Manufactured by ITEC Tontechnik und Industrieelektronik GesmbH 8200 Laßnitzthal 300 Austria / Europe

Allen-Bradley Bulletin 100 Contactors

Rexroth Controller Installation & Operations Manual

PS/IO Circuit Board Retrofit

Posi-Lok Plugs and Panels

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER

Westell. Breaker Panel Technical Practice NPDRP1114

Test Blocks, Plugs, and Probes or When the Dynamo Meets the Integrated Circuit

OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES

topter SERIES ACTIVE PROTECTION Leading Electrotechnology

60103 Circuit Breaker

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

Large Frame IEC Contactors

920 Remote Control (RC) Switches

Smart-UPS XL APC Smart-UPS XL 2200VA RM 3U 120V

Auto-Transfer Rack Power Distribution Unit

E-ACLM-V E-ACLM-P12/8/18 AC LINE MONITORS Installation and Operation Manual

Square D Meter Centers. A Comprehensive. Selection. Time-Saving, Reliable. Solutions

PC-250B Solid State Vital Biased Code Following Track Relay

Smart-UPS APC Smart-UPS 1500VA USB & Serial 120V

Go to:

Power Supply (48Vdc, 2.5A)

SECTION DISCONNECT SWITCHES

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

An ISO 9001 Company. KLP POWER SUPPLY

Power and protection for your rackmount and cabinet equipment.

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

ASCO 920 Remote Control (RC) Switches

Welcome to the safety functions configuration training module for ACS880 Cabinet-built industrial drives.

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Latching, Sequence and Impulse Relays Application Data

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Ground Power Modules. And Accessories For Healthcare Facilities. Technical Bulletin NAE /

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Symmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

White Paper. UL Standards for Power Control System Equipment

Benefits, offering and references

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S

INSTALLATION MANUAL SLI 50 INVERTER

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY I INTRODUCTION

Best practices for making switchgear safer.

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

DIGITAL PANEL THERMOMETER

Smart-UPS APC Smart-UPS 750VA USB & Serial 120V

Transfer Switches 5.1 Transfer Switch Equipment Product Selection Guide... Product Description... Application Description...

ENERGY SAFELY SWITCHED SWITCHGEAR. BUSBAR SYSTEM 60 mm

satech TSB-14 MAIN FEATURES

Smart-UPS APC Smart-UPS 2200VA USB & Serial 120V

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

ArmorConnect Power and Control Media

5 Performance Verification

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

Model 720 Electromechanical Hour Meter

Trident and Trident X2 Digital Process and Temperature Panel Meter

Instruction Manual. Rack PDU XP Series. geistglobal.com

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

DMC2. Installation Guide Version 1.0. Area for main photograph. Area for insert photo. W: 46.1mm up to 79 mm H: 46.1mm

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY.

Transcription:

FT Flexitest Family Switches, Covers and Test Plugs

FT Flexitest Switches Description The flexibility provided by the FT case design evolved into a separate family of molded base test switches for testing relays, meters and other electrical devices. FT test switches provide a cost-effective means to wire the outputs of relays, meters and other associated equipment to an external device for in-service testing and has been an industry standard for many years. Standard switches are available in many combinations of potential, current or current shorting poles and special combinations are available on request. Typical test switches come in either 10 or 14 pole and there is a new front connected version of the 10 pole switch. Application The ABB FT Flexitest switches provide a safe, simple, fast and reliable method to isolate and service installed equipment. With an almost unlimited amount of configurations and the ability to customize, the switches may be provided as individual units or mounted in a 19" panel. Rated for 600 volts and 30 amperes, the Flexitest switches provide unparalleled safety and convenience for switchgear, breaker, relay, metering or industrial applications where in-service testing, isolation, calibration or monitoring is required without de-powering panels. Features The Flexitest switches have all the features necessary for applications involving the measurement of individual currents and voltages to facilitate testing of substation instrumentation and protection devices. Multiple combinations of current or voltage switches create flexibility. The make before break current short circuit feature also allows test personnel to quickly and safely isolate equipment from current transformer circuits. The extended test switches bring the rear terminal connections to the same depth as most panel mounted protective relays and equipment. Extended unit terminals are the same depth as other 19" rack equipment, making it easier to wire. Optional colored handles are available. Longevity - over 50 years of proven field experience Technical support - 24 hours a day, 7 days a week Complete line of switches, switch assemblies and test plugs for separate source and in-service testing Standards > UL recognized > 1E qualified switches > ISO9001 certified facility > Independent third party verification of quality programs Safety - The positive make before break short circuit feature safely isolates equipment from current transformer circuits. Security - Meter seal capability through either of the cover studs prevents unauthorized access to the switch with the cover on. Convenience - immediate access to relay or other device circuits without disconnecting any wiring Flexibility - Switches are available with up to 14 current or potential circuits in various combinations to meet customer's application needs. Quality - unsurpassed quality with over 50 years of field proven application and vigorous quality testing programs Short lead times - stock to two weeks maximum, emergencies shipped within 24 hours - sometimes same day ABB Substation Automation and Protection relays and products are backed by a 12- YEAR warranty.

Test Switches FT-1 & FT-14 FT-1-10 pole switch FT-14-14 pole switch FT-19R FT-19R - option to mount the FT-1 into a 19 panel rack FT-1 Provides up to 30 terminals using combinations of one to three FT-1 switches Pre-drilled 19" panels Clear or black covers Standard test plug compatible FT-14 Available as one long cover or individual covers over each switch Large nameplates available Select any combination of FT-1 switches FT-19R Panel color or finish, as well as panel height, can be customized Room available for any special customer label requirements FT-1X Extended Extended unit terminals are the same depth as other 19" rack equipment, making it easier to wire. FT-19R Extended

Test Switches FT-19RS Special Assemblies FT-19RS - put FT switch into a panel, allowing for meter and lockout switches on panel Any customer derived configuration Two FT-1 Switches Centered on 19 Plate Two FT-1 Switches with On/Off Switch on 19 Plate Two FT-1 Switches with Lockout Switch on 19 Plate Two FT-1 Switches with Synchrotact on 19 Plate Front Connected FT-1F Flexibility multiple combinations of current or voltage switches (1-10 switches) Surface mounting Optional colored handles Front Connected

Accessories Covers Covers fit on all FT switches Two types: > clear Flexible switches open or close with cover mounted Security full visibility blade position Safety energized blades not exposed Prevents covers from being lost or damaged Clear covers can be tinted > standard black Security cover mounts only with switch closed Standard Black Cover Clear Cover Test Plugs Used in conjunction with all FT switches Three types: > individual - single pole for in-service measurement > in service - configured for specific FT switch so isolation testing can be performed according to configuration > separate source - isolates all devices that are wired into the test switch - universal will go into any configuration Individual Test Plug Separate Source Test Plug Enhanced connection capability Standard banana plugs Spade lugs Ring lugs Meter test probes or wire connections Custom or standard cables and harnesses FT Test Kit The ABB FT test kit comes with a convenient carrying case to hold your hand held meter, test plugs patch cords, clips, and test probes in neat order. Patch cords are highly durable and flexible. FT Test Kit

Produced in Coral Spring, Florida since 1977, the FT Flexitest switch is a well-established design, starting as an integral part of the electromechanical protective relay product group dating back to the late 1950's. The standalone FT-1 Flexitest switch was introduced using the same switch mechanism design that has proven to be safe and reliable for more than 50 years. The many design changes, since the beginning of production, range from a special alloy developed for the application, to profile changes to the switch blade to optimize reliability, quality, and performance. No other test switch matches the number of operations the ABB Flexitest switch performs, without any visible deterioration of the blade plating and between the switch jaws. The plating requirements for all components, including full coverage between the switch jaws, assure that even in harsh environments, corrosion is prevented, eliminating elevated operating temperatures through reduced contact area. The Flexitest switch is qualified for Nuclear application. The switch has a unique design that provides the maximum surface contact area, over any other switch on the market, in both the normal operation, as well as in the testing mode. Additionally, the Flexitest test switch meets the highest temperature rating in the latest IEEE proposed standard. When your requirements call for a test switch, have peace-of-mind by specifying the well-proven ABB Flexitest switch products. And don t forget that ABB can supply specialized test switch products or assemblies to meet special requirements. Please see descriptive bulletin DB41-077 for selection information on the FT-1 test switch and descriptive bulletin DB41-078 for selection information on the FT-19R assembly. DB41-079 Rev. D January 2007 Copyright 2007 ABB. All rights reserved. ABB Inc. 4300 Coral Ridge Drive Coral Springs, Florida 33065 Tel: 1-800-523-2620 or +1-954-752-6700 or for 24 hour 1-800-222-1946 www.abb.com/substationautomation