Bayonet resistance thermometer Model TR53

Similar documents
Threaded resistance thermometer Miniature design Model TR10-D

Threaded thermocouple Miniature design Model TC10-D

Resistance thermometer With spring-loaded tip Model TR55

Resistance thermometer For additional thermowell Model TR10-B

Threaded resistance thermometer With protection tube Model TR10-C

Threaded resistance thermometer Model TR10-C, with protection tube

Gas-actuated thermometer Stainless steel version Model 73

Reed sensor For bypass level indicators Model BLR

Thermocouples Model TC200, for Additional Thermowell

Differential pressure sensor For ventilation and air-conditioning Model A2G-50

Hand-held thermometer, industrial version Model CTH6300 Model CTH63I0, Ex version

Hand-held thermometer, precision version Model CTH6500 Model CTH65I0, Ex version

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

Bourdon tube pressure gauge with electrical output signal Stainless steel, safety version, NS 63 Model PGT23.063

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

Level sensor with reed measuring chain Model FLR, for the process industry

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Temperature dry-well calibrator Models CTD9100-COOL, CTD , CTD , CTD

Micro calibration bath Models CTB , CTB

Terminal Boxes Series 8118

Temperature dry-well calibrator Models CTD , CTD

Temperature dry-well calibrator Models CTD9100-COOL, CTD , CTD , CTD

Dual differential pressure sensor For ventilation and air-conditioning Model A2G-52

Level sensor Stainless steel version Model RLT-1000, for industrial applications

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Hand-held thermometer Model CTH6200

Hand-held thermometer Model CTH7000

Electronic pressure switch with display Model PSD-4

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Safety instructions Overvoltage protection B81-35

Programming unit VIATOR HART modems Model PU-H

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Electronic pressure switch with display For sanitary applications Model PSA-31

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

SolConeX Wall-Mounted Socket, 16 A

Precision digital pressure gauge Model CPG1500

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

Float switch For industrial applications Model RLS-1000

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Inductive sensor NI3-EG08K-Y1-H1341

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Grounding Monitoring Device Series 8485

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Magnetic float switch For vertical installation Model FLS

Electronic pressure switch with display For sanitary applications Model PSA-31

Electronic pressure switch with display For sanitary applications Model PSA-31

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Grounding Monitoring Device Series 8485

Slot Resistance Thermometers

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Float Switches with Permanent Magnet For Horizontal Installation Model HIF

Inductive sensor with analog output BI15-M30-LI-EXI

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

SMARTLINE RM76 Supplementary instructions

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Position Switches Series 8070

Pneumatic Control/Feedback

Inductive sensor BI5-EM18-Y1X-H1141

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2

Load Disconnect Switches and Motor Switches

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Linear Luminaire with LED Series 6412/5

Cable End Boxes Series 8146

Pneumatic Control/Feedback

Multi-functional precision thermometer CTR3000

Float switch For the process industry, lateral installation with external chamber Model ELS

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Cable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof

Approx. 4 s, measured in oil, with a probe Ø of 10 mm made of stainless steel. Influential effect of the ambient temperature

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

PHOENIX CONTACT - 01/2008

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Hand-held thermometer Model CTH7000

Pneumatic Control/Feedback

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

Precision digital pressure gauge Model CPG1500

Technical Data. General specifications. Rated operating distance s n 3 mm

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Micro Motion, Inc. Page 1 of 6

Series 3730 Type Electropneumatic Positioner

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

ExCos-P Pressure sensor 20 Pa Pa

Standard reference resistor Model CER6000

Operating and monitoring systems Thin Client SERIES 500 Device platform EAGLE PM ET-556-TX

Level measurement. Applications. Special features. Description

Transcription:

Temperature Bayonet resistance thermometer Model TR53 WIKA data sheet TE 60.53 for further approvals see page 2 Applications Plastics processing machinery Injection moulding machinery Cylinder heads and oil sumps in engines Bearings Pipelines and vessels Special features Sensor ranges up to max. 400 C (752 F) Single and dual resistance thermometers Good heat transfer through adjustable spring-loading Easy installation and removal, no tools needed Explosion-protected versions Model TR53 with optional threaded nipple Description Probe This cable resistance thermometer feature a bayonet-type probe connection. TR53 series resistance thermometers can be mounted into drilled holes without thermowells, e.g. into machine components. Cable There are various insulating materials available to match different environmental conditions. The free ends of the cable are made up ready for connection, or can be fitted with connectors or sockets as optional extras. Page 1 of 12

Explosion protection (option) The permissible power, P max, as well as the permissible ambient temperature, for the respective category can be seen on the EC-type examination certificate, the certificate for hazardous areas or in the operating instructions. The internal inductance (L i = 1 µh/m) and capacitance (C i = 200 pf/m) for cable probes are found on the product label and they should be taken into account when connecting to an intrinsically safe power supply. Note: When mounting thermometers with flying leads, installation personnel must ensure that installation is carried out properly and in compliance with the appropriate regulations. If the cable ends of the thermometer are within the hazardous area, suitable adapters/connectors must be used. Flying leads must be connected outside the hazardous area or, when operated in a dust explosive atmosphere, within an enclosure which is certified. The connection of a resistance thermometer (e.g. Pt100) to a transmitter must be made with shielded cable. The shield must be electrically connected to the case of the grounded thermometer. It should be ensu that there is equipotential bonding on installation, so that no balancing current can flow via the shield. Here, in particular, the installation regulations for hazardous areas should be followed! Approvals (explosion protection, further approvals) Logo Description Country EU declaration of conformity European Union RoHS directive ATEX directive (option) - Ex i Zone 0 gas [II 1G Ex ia IIC T1... T6 Ga] Zone 1 mounting to zone 0 gas [II 1/2G Ex ia IIC T1... T6 Ga/Gb] Zone 1 gas [II 2G Ex ia IIC T1... T6 Gb] Zone 20 dust [II 1D Ex ia IIIC T125... T65 C Da] Zone 21 mounting to zone 20 dust [II 1/2D Ex ia IIIC T125... T65 C Da/Db] Zone 21 dust [II 2D Ex ia IIIC T125... T65 C Db] - Ex n Zone 2 gas [II 3G Ex na IIC T1... T6 Gc X] Zone 22 dust [II 3D Ex tc IIIC T440... T80 C Dc X] IECEx (option) (in conjunction with ATEX) - Ex i Zone 0 gas [Ex ia IIC T1... T6 Ga] Zone 1 mounting to zone 0 gas [Ex ia IIC T1... T6 Ga/Gb] Zone 1 gas [Ex ia IIC T1... T6 Gb] Zone 20 dust [Ex ia IIIC T125... T65 C Da] Zone 21 mounting to zone 20 dust [Ex ia IIIC T125... T65 C Da/Db] Zone 21 dust [Ex ia IIIC T125... T65 C Db] International Page 2 of 12

Logo Description Country EAC (option) - Ex i Zone 0 gas [0 Ex ia IIC T3/T4/T5/T6] Zone 1 gas [1 Ex ib IIC T3/T4/T5/T6] Zone 20 dust [DIP A20 Ta 65 C/Ta 95 C/Ta 125 C] Zone 21 dust [DIP A21 Ta 65 C/Ta 95 C/Ta 125 C] - Ex n Zone 2 gas [Ex na IIC T6... T1] Zone 22 dust [DIP A22 Ta 80... 440 C] INMETRO (option) - Ex i Zone 0 gas [Ex ia IIC T3... T6 Ga] Zone 1 mounting to zone 0 gas [Ex ib IIC T3... T6 Ga/Gb] Zone 1 gas [Ex ib IIC T3... T6 Gb] Zone 20 dust [Ex ia IIIC T125... T65 C Da] Zone 21 mounting to zone 20 dust [Ex ib IIIC T125... T65 C Da/Db] Zone 21 dust [Ex ib IIIC T125... T65 C Db] NEPSI (option) - Ex i Zone 0 gas [Ex ia IIC T3 ~ T6] Zone 1 mounting to zone 0 gas [Ex ia/ib IIC T3 ~ T6] Zone 1 gas [Ex ib IIC T3 ~ T6] KCs - KOSHA (option) - Ex i Zone 0 gas [Ex ia IIC T4... T6] Zone 1 gas [Ex ib IIC T4... T6] - PESO (option) - Ex i Zone 0 gas [Ex ia IIC T1... T6 Ga] Zone 1 mounting to zone 0 gas [Ex ib IIC T3... T6 Ga/Gb] Zone 1 gas [Ex ib IIC T3... T6 Gb] DNOP - MakNII (option) - Ex i Zone 0 gas [II 1G Ex ia IIC T3, T4, T5, T6 Ga] Zone 1 gas [II 2G Ex ia IIC T3, T4, T5, T6 Gb] Zone 20 dust [II 1D Ex ia IIIC T65, T95, T125 C Da] Zone 21 dust [II 2D Ex ib IIIC T125... T65 C Db] GOST (option) Metrology, measurement technology KazInMetr (option) Metrology, measurement technology - MTSCHS (option) Permission for commissioning BelGIM (option) Metrology, measurement technology UkrSEPRO (option) Metrology, measurement technology Uzstandard (option) Metrology, measurement technology Eurasian Economic Community Brazil China South Korea India Ukraine Russia Kazakhstan Kazakhstan Belarus Ukraine Uzbekistan Instruments marked with ia may also be used in areas only requiring instruments marked with ib or ic. If an instrument with ia marking has been used in an area with requirements in accordance with ib or ic, it can no longer be operated in areas with requirements in accordance with ia afterwards. Approvals and certificates, see website Page 3 of 12

Sensor Application range The application range of the sensor is limited by the permissible temperature for the cable insulation. Sensor connection method 2-wire 3-wire 4-wire Sensor tolerance value per IEC 60751 Class B Class A Class AA The combinations of a 2-wire connection with class A or class AA are not permissible, since the lead resistance of the measuring insert negates the higher sensor accuracy. For detailed specifications for Pt100 sensors, see Technical information IN 00.17 at www.wika.com. Probe Design: Rigid tube Material: Stainless steel Diameter: 6 mm or 8 mm Length: 10 mm other versions on request For temperature measurement in a solid body, the diameter of the bore into which the sensor should be inserted must be no more than 1 mm larger than the sensor diameter. Maximum working temperatures The maximum working temperature for these thermometers is limited by different parameters. If the temperature to be measu inside the sensor measuring range is higher than the permissible temperature at the connection cable, the connector or the transition point, the metallic part of the sensor (mineral-insulated cable) must be long enough to place the critical components outside of the hot zone. The lowest of the maximum working temperatures of connection line, cable transition or connector must be observed here. Sensor Measuring element Pt100 (measuring current: 0.1... 1.0 ma) 1) Connection method Single elements Dual elements 1 x 2-wire 1 x 3-wire 1 x 4-wire 2 x 2-wire 2 x 3-wire 2 x 4-wire 2) Tolerance value of the measuring insert per IEC 60751 Class Sensor construction Wire-wound Thin-film Class B -196... +600 C -196... +450 C -50... +500 C -50... +250 C Class A 3) -100... +450 C -30... +300 C Class AA 3) -50... +250 C 0... 150 C 1) For detailed specifications for Pt100 sensors, see Technical information IN 00.17 at www.wika.com. 2) Not with 3 mm diameter 3) Not for 2-wire connection method Connection cable and single wires At any point on the connection cable, the maximum temperature that may be attained is that for which the connection cable is specified. The sensor itself can potentially withstand higher temperatures. For the common connection lines the following maximum operating temperatures apply: PVC -20 +100 C Silicone -50 +200 C PTFE -50 +250 C Fibreglass -50 +400 C Since, in the tubular design variant, an isolated cable is also fitted within the metal probe, the operating limits of the connecting cable apply. Page 4 of 12

Transition from the metal part of the thermometer to the connection cable The temperature at the transition is further limited by the use of a potted sealing compound. Temperature range of the potting compound: -40... +150 C Option: 250 C (other variants on request) Temperature range of the special low-temperature version: -60... +120 C 4) IP ingress protection Bayonet resistance thermometers can be delive with up to IP65 (dependent on cable sheath material and number of wires). With a special design, IP67 is also possible on request. Connection leads with a glass-fibre sheath cannot be combined with an explosion-proof version. 4) only available with selected approvals Connector (option) With the option of a coupler connector fitted the maximum permissible temperature range is: Lemosa: -55... +250 C Binder, Amphenol: -40... +85 C Transition The junction between the metal part of the probe and the connecting cable or wire is either rolled or potted, depending on the design. This area should not be immersed within the process and must not be bent. Compression fittings should not be attached to the transition. The version and dimensions of the transition depend largely on the combination between supply line and metal sensor and the sealing requirements. The dimension T describes the length of the transition. Criterion Dimensions T in mm Ø transition in mm Probe Ø = transition sleeve Ø n/a Identical to probe Ø 6 mm with crimped transition 45 7 Ø 6 mm 45 8 with crimped transition 5) Ø 8 mm with crimped transition 45 10 5) With a large number of wires (e. g. 2 x 3-wire and shielding) Page 5 of 12

Cable Wire material: Cu (stranded wire) Wire cross-section: approx. 0.22 mm² Number of wires: According to the number of sensors and the sensor connection method Wire ends: Blank Connecting cable There are various insulating materials available to match different environmental conditions. The free ends of the cable are made up ready for connection, or can be fitted with connectors or sockets as optional extras. Probe diameter Cable sheath (insulation) silicone Cable sheath (insulation) PTFE d in mm Working temperature -50... +200 C Working temperature -50... +250 C Standard Shielded Standard Shielded With stainless steel braiding 6 1 x 2-wire - 1 x 2-wire 1 x 2-wire 1 x 2-wire 1 x 2-wire - 1 x 3-wire 1 x 3-wire 1 x 3-wire 1 x 2-wire - 1 x 4-wire 1 x 4-wire 1 x 4-wire 1 x 2-wire - 2 x 2-wire 2 x 2-wire 2 x 2-wire 8 1 x 2-wire 1 x 2-wire 1 x 2-wire 1 x 2-wire 1 x 2-wire 1 x 3-wire 1 x 3-wire 1 x 3-wire 1 x 3-wire 1 x 3-wire 1 x 4-wire 1 x 4-wire 1 x 4-wire 1 x 4-wire 1 x 4-wire 2 x 2-wire 2 x 2-wire 2 x 2-wire 2 x 2-wire 2 x 2-wire 2 x 3-wire - - 2 x 3-wire 2 x 3-wire Process connection Bayonet cap on the probe, with matching threaded nipple for screw-fitting to a solid body (process). Threaded nipple (parallel thread) NG Bayonet cap 11050101.02 NS Legend: NS Nominal size bayonet Ø NB Nipple bore SW Flats i Thread length Probe Ø Process NS Nipple bore Spring Ø Flats Thread length Order no. Ø d connection Ø NB Ø FD SW i 6 M10 x 1 12 6,4 6 14 10 3120914 M14 x 1,5 14 8,4 6 17 10 3366788 G ¼ B 14 8,4 6 17 10 3118927 G ⅜ B 14 8,4 6 17 11 3118901 8 M14 x 1,5 14 8,4 7 17 10 3366788 G ¼ B 14 8,4 7 17 10 3118927 G ⅜ B 14 8,4 7 17 11 3118901 Material: Brass, nickel-plated Page 6 of 12

Dimensions in mm Bayonet cap fixed to the end of the spring (sheathed cable design) Probe tip, flat Probe tip, chamfe 11344148.01 Probe tip, round Bend protection optional, but mandatory for Ex n Legend: Ø d Probe diameter L Probe length W Cable length Ø FD Spring diameter A Insertion length X Probe extension T Transition sleeve SD Spring length Page 7 of 12

Bayonet cap adjustable on the spring (sheathed cable design) Probe tip, flat Probe tip, chamfe 11343168.02 Probe tip, round Bend protection optional, but mandatory for Ex n Legend: Ø d Probe diameter L Probe length W Cable length Ø FD Spring diameter A Insertion length X Probe extension T Transition sleeve SD Spring length Page 8 of 12

Bayonet cap adjustable on the spring (cable through to the probe tip) Probe tip, flat Probe tip, chamfe 11050101.02 Probe tip, round Legend: Ø d Probe diameter L Probe length W Cable length Ø FD Spring diameter A Insertion length X Probe extension T Transition sleeve SD Spring length Page 9 of 12

Connector (option) Bayonet resistance thermometers can be supplied with connectors fitted. The following options are available: Screw-in-connector, Binder (male) Screw-in-connector, Binder (female) Lemosa connector size 1 S (male) Lemosa connector size 2 S (male) Lemosa coupling size 1 S (female) Lemosa coupling size 2 S (female) Spade lugs (not suitable for versions with bare connecting wires) 11355728.01 Other connector variants (sizes) on request. Page 10 of 12

Electrical connection Without connector 1 x Pt100 2-wire white 3160629.06 2 x Pt100 2-wire white black 3160629.06 1 x Pt100 3-wire white yellow 1 x Pt100 4-wire white white 2 x Pt100 3-wire white black black yellow Lemosa connector max. permissible temperature range: -55... +250 C Screw-in-connector, (Amphenol, Binder) max. permissible temperature range: -40... +85 C Connector (male) Socket (female) Connector (male) Socket (female) Front view Front view 3366036.02 View of the connector contacts Binder Series 680 Series 423 (shielded) View of the socket contacts 3366142.05 Binder Series 680 Series 423 (shielded) Binder Series 680 Series 423 (shielded) Binder Series 680 Series 423 (shielded) Binder Series 692 Amphenol C16-3 Page 11 of 12

Certificates (option) Certification type Measuring accuracy 2.2 Test report x x Material certificate Other certificates on request. Ordering information Model / Bayonet version / Explosion protection / Sensor tip version / Probe diameter and length / Probe version / Bayonet cap material / Measuring element / Temperature range / Sheath, raw material / Connection cable, sheath / Lead end version / Certificates / Options 12/2010 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. 07/2018 EN Page 12 of 12 WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de