F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Similar documents
RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

VIDI-AC-2CS Access Controller/ Reader

Stand-alone Proximity Access Control

-DTZ001- Stand-Alone Proximity Access Control. User Manual

RBR-SB-KTZ001 LAR 2. User Manual

DOLXFD1000B. Waterproof Access Control/Reader

Waterproof. Keypad/Reader/Controller

VIS-3200 / VIS-3201 User Manual

W3-H Waterproof Keypad/Reader/Controller

Single Door Standalone Access Control User Manual

W3-M. Metal waterproof standalone access control/reader. User Manual

Fingerprint Access Control F1. User Manual

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

CM-110SK Standalone Keypad Installation Instructions

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

Digital Keypad Introduction

BC Digital Keypad. User Manual

User Manual. Split access control with intelligent secured power supply.

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

DG-800 Stand-Alone Proximity Reader Instruction Manual

User Manual. PCKeypad Wireless Keypad

EL-ST100 KEYPAD CONTROLLER

Installation and User Manual

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

REX F-0-9 Standalone or Access Controller

CC Series metal access control Manual

1. Product Specification

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

CV-945 Stand-Alone Biometric Reader. Installation Instructions

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

AS Keypad User Manual

HSY-S209 EM Metal waterproof access control system User Manual

ACCESS CONTROL SYSTEM

CM-500 SK 500 USER CODES KEYPAD

GV-AS Controller. Installation Guide

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

212iL Rev. 1.1

GV-Card Reader. User s Manual

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

UC-2000 Installation Manual Unicorn Computers Technology Limited

_ Access control SISTEMAS DE SEGURIDAD

2000 Series e/em Style Keypad Installation and Programming Manual

9212i INSTALLATION. Stand-Alone Keypad. Instructions

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

GV-RK1352 and GV-R1352 Card Reader

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details

RFID/Digital Access Control Keypad

7612 Programming Instructions

IBA-7612 Programming Instructions

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

Fingerprint Identification Proximity Reader. Quick Installation Guide

S125 Multi-Purpose 125 KHz RFID Reader USER MANUAL. 9V/24V DC Operating Voltage, AC (optional) KHz RFID EM4100/2 Cards & Tags

Specifications: Features:

BIOC3 V1 USER S MANUAL. Biometric Reader v. b1

A-1300 Biometric Access Control System USER'S MANUAL

Metal Standalone Keypad Access Control S100

716 Converter. Programmable Data Converter

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

GV-AS/EV Controller. User s Manual

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

B100-SA Standalone Biometric Reader

Operation manual For NG BIOSINGLE Version 1.1

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

Proximity Card and Pin Reader Installation Manual

EX8. User Manual. Ver 1.0

KP2000E/EM Series Style Keypad

Access control panel U-Prox IC E (Elevator control)

Stand-Alone Data Chip System

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

OEM Proximity Reader with Keypad Manual REV1

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

F-X20FO Fingerprint safe

XP-KIT. Programming & Operations. Programming Starter Kit for Aiphone -XP Series Proximity Reader Stations

FTK5 PROXIMITY KEYPAD

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0

Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate

F18. Fingerprint capacity 3,000 Transaction capacity 100,000 Hardware Platform ZK 6001, 400Mhz 64M Flash, 32MSDRAM. Identification speed

GV-EL124S Electric Strike

Fingerprint Door Lock OPERATOR S MANUAL

PR602LCD v1.0 Installer Manual Rev. A

Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader

DINB100-SA Standalone Biometric Reader

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

Standalone Access Control

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

PAC1 Door Access Controller

INSTRUCTION MANUAL AC-T43 PIEZO-KEYPAD STANDALONE ACCESS CONTROL UNIT. 07/04

MS-7000: SuperStar Reader

Transcription:

-Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add PIN User Delete User 0 (New Master Code) # (Repeat New Master Code) # (code: 4~8 digits) 1 (Fingerprint) (Repeat Fingerprint) # 1 (Read Card) # 1 (User ID #) (PIN #) # (PIN can be any 6~8 digits number) 2 (Fingerprint) # 2 ( Card) # 2 (User ID #) # Exit from the programming mode How to be granted access Fingerprint User Card User PIN User Input Fingerprint Read card Enter (User ID #) (PIN #) User Manual

INTRODUCTION is a compact design standalone access control device. It supports fingerprint, card, PIN, which offers users more options for access. The Wiegand interface makes it be able to work as rd reader to a 3 party controller. Also it supports downloading and uploading users' information by USB, users needn't be enrolled again if you need to install more devices. Main Features: One relay Pulse mode, Toggle mode Verification method: Fingerprint, ID card, PIN User capacity: 500 fingerprint users, 2000 ID card users, 500 PIN users Card interface: 125KHz EM Card/Tag PIN length: 6~8 digits Support USB flash drive copy fingerprint, card, PIN users information Access control interface for 3rd party electric lock, door sensor, exit button, alarm Wiegand 26 bits output Programmable facility code Door bell Relay Adjustable Relay Output Time Lock Output Load Alarm Output Load Wiegand Interface Environment Operating Temperature Operating Humidity Physical Dimensions Unit Weight Shipping Weight Carton Inventory One (NO, NC, Common) 1-99 Seconds (5 seconds default) 2 Amp Maximum 5 Amp Maximum Indoor ABS Enclosure 88mm *88mm* 30mm 350g 400g Specification User Capacity Fingerprint Card PIN Operating Voltage Idle Current Active Current Fingerprint Reader Resolution Identification time FAR FRR Proximity Card Reader Radio Technology Read Range PIN Reader Wiring Connections Communication 3000 500 2000 500 +12V 60mA 100mA Optical Fingerprint Module 500DPI <1S <0.0001% <0.01% Industry Standard 26 bits 125KHz Industry Proximity EM Card 2~7 cm 6~8 digits PIN Relay Output, Exit Button, DOTL, Alarm, Wiegand Output, Door Bell USB for downloading/uploading Fingerprint Reader Diode 1N4007 (For relay circuit protection) Self Tapping Screws(3X25mm) Wall Anchors(3X25mm) USB cable 11 Pin cable 2 Pin cable (Wiegand) Screw Driver 01 02

INSTALLATION Connection Diagram Lock 1: Fail-Secure Lock or Door/Gate Operator Lock 2: Fail-Safe Lock or Magnetic Lock Common power supply: IN 4007 Wiring Wire Colour Function Notes Red Black Blue Orange Purple Yellow Green White GND White Grey Brown 12V DC GND Relay NO Relay Common Relay NC OPEN Data 0 Data 1 GND Bell + Green Bell - Basic Stand Alone Wiring 12V DC Regulated Power Input Ground Normally Open Relay Output (install diode provided) Common Connection for Relay Output Normally Closed Relay Output (Install diode provided) Request to Exit (REX) Input Pass-Through Wiring (Wiegand Reader) Alarm Output Contact Input Wiegand Output (Pass-through) Data 0 Wiegand Output (Pass-through) Data 1 Connect to Controller to stabilize the Wiegand transmit (Optional) Advanced Input and Output Features Positive Contact for Door Bell Negative Contact for Door Bell Negative contact for Alarm Door/Gate Contact Input (Normally Closed) IN 4007 Attention: Install a 1N4007 or equivalent diode is needed when use a common power supply, or the reader might be damaged. (1N4007 is included in the packing) 03 04

Access Control Power Supply: PROGRAMMING Programming 1 ----------------Program Fingerprints, Cards and PINs GENERAL PROGRAMMING INFMATION User ID Number: Assign a user ID number to the fingerprints, cards, or PINs in order to keep track. The user ID number can be any number from 1~ 9999. User IDs do not have to be proceeded with any leading zeros. IMPTANT: The PIN user must use the User ID together with PIN for access. Proximity Card: Any 125KHz industry standard 26 bits EM Proximity card PIN: Any 6~8 digits number ADD USER FINGERPRINT(S) 2. Add Card: Using Auto ID (Allows to assign Fingerprint to next available User ID number) 2. Add Fingerprint: Select Specific ID (Allows Master to define a specific User ID to associate the fingerprint to) Factory default: 1234 1 (Fingerprint) ( Repeat Fingerprint) # Repeat Step 2 for additional user Fingerprints 1 (User ID) # (Fingerprint) ( Repeat Fingerprint) # The user ID of fingerprint is any number from 1~9999 Door Bell White Green Pass-through: Please check Others No.4 Pass-through Operation ADD USER CARD(S) 2. Add Card: Using Auto ID (Allows to assign card to next available User ID number) 2. Add Card: Select Specific ID (Allows Master to define a specific User ID to associate the card to) 2. Add Card: by Card Number 1 (Read Card) # Repeat Step 2 for additional user cards 1 (User ID) # (Read Card) # The user ID of fingerprint is any number from 1~9999. 1 (Input 8 or 10 digits Card number # ) # 1 (User ID) # (Input 8 or 10 digits Card number #) # 05 06

ADD USER PIN(S) 2. Add PIN: Select Specific ID (Allows Master to define a specific User ID to associate the PIN to) 1 (User ID) # (PIN # ) # The user ID is any number from 1~9999 PIN is any 6~8 digits number 2. Pulse Mode 2. Toggle Mode 3 (1-99) # The relay time is 1-99 seconds(1 is 50ms) Default is 5 seconds 3 0 # Sets the relay to ON/OFF toggle mode DELETE USER FINGERPRINT(S) CARD(S) PIN(S) 2. Delete User By User ID 2 (User ID # ) # 2. Delete User By Fingerprint/Card 2(Input Fingerprint)# 2 (Read Card) # PROGRAMMING 2 -------------------------------Configure the Change the configure settings according to your application (optional). Multiple configuration settings can be changed at one time: enter program mode, change desired settings, then exit program mode. SET MASTER CODE The 4~8 digits Master Code is used to prevent unauthorized access to the system. To interface with the, the Master will need a Master Code (factory default code: 1234). We highly recommend immediate update and recording of your Master Code. 2. Update Master Code 0 (New Code) # (New Code) # New master code can be any 4~8 digits number SET RELAY CONFIGURATION The relay configuration sets the behavior of the output relay on activation. SET DO OPEN TOO LONG (DOTL) ALARM This setting requires an external sensor input. 2. DOTL Alarm OFF 2. DOTL Alarm ON 2. DOTL Timing 4 0 # 4 1 # 5 (1~254 ) # The DOTL timing can be set to 1-254 seconds. After the door open, it will check the door contact, if the open time beyond the DOTL timing set, it will alarm. Firstly, it is the built-in buzzer beeps; after 30 seconds, the output alarm equipment will alarm SET STRIKE-OUT ALARM The strike-out alarm will engage after 8 failed fingerprint/card/ PIN attempts in 10 minutes. Factory default is OFF. The strike-out alarm can be set to disengage only after entering a valid fingerprint/card/ PIN. 2. Strike-Out OFF 2. Strike-Out ON 6 0 # (factory default) 6 1 # The buzzer alarms 07 08

PROGRAMMING 3-----------------------------Advanced Application REGISTER MASTER FINGERPRINT/CARD 2. Register Master Add Fingerprint Register Master Delete Fingerprint Register Master Add Card Register Master Delete Card SYSTEM SETTING 2. Reset to Factory Default Delete All Users Delete All Masters SET VISUAL RESPONSE 2. Control LED & Key Backlight 2. Control Fingerprint Sensor OTHERS 1. Users Operation: Open the door: Fingerprint User Card User 1 * 1 # Fingerprint Repeat Fingerprint 1 * 2 # Fingerprint Repeat Fingerprint 1 * 1 # Read Card 1 * 2 # Read Card 9 0 # Reset all setting to factory default. (All users' information will still be retained) 9 1 # 9 2 # OFF: 7 0 # (Factory default) OFF: 7 2 # Input Fingerprint Read Card PIN User Input User ID # PIN # ON: 7 1 # ON: 7 3 # (Factory default) Remove Alarm: Input valid fingerprint, or read valid user card or input User ID # Valid PIN #, or input Master Code # 2. Master Operation (Master Fingerprint / Maser Card) To Add User by Master Add Fingerprint Master Add Fingerprint Input User Fingerprint Twice / Read Card Master Add Fingerprint To Delete User by Master Delete Fingerprint Master Delete Fingerprint Input User Fingerprint Once / Read Card Master Delete Fingerprint To Add User by Master Add Card Master Add Card Input User Fingerprint Twice / Read Card Master Add Card To Delete User by Master Delete Card Master Delete Card Input User Fingerprint Once / Read Card Master Delete Card 3. Sound and Light Indication Stand by Operation Status LED Buzzer Enter into programming mode In the programming mode Set Operation succeed Operation error Exit from the programming mode Open lock Alarm Red light shines Red light bright Purple light bright Red light shine Red light shines quickly One beep One beep One long beep Three beeps Two beeps One beep Beeps 4. Pass-Through Operation can be operated as a Wiegand Output Reader to the Controller. In this mode, the supports Wiegand 26 bits output, so the Wiegand data lines can be connected to any controller which supports a Wiegand 26 bits input. The connection diagram is as below: 09 10

5. Download / Upload Users' information by USB. can download all the users' information (Fingerprint, Card, PIN) by USB. Download: 1. Connect the with the Flash Drive or some thing similar by the USB cable provided. The LED will flash quickly in red 2. Input * Master Code # The LED will turn in purple, and there will be a long beep, LED shines in blue, means download the users' information successfully. Upload: 1.Connect the Flash Drive with another (MUST without users' information) by the USB cable. 2.Input * Master Code # The LED will turn in purple, and there will be a long beep, LED shines in blue, means upload the users' information successfully. SET DEVICE ID 2. Set Device ID 8 (1-255) # Keypad Transmission The Reader will transmit the PIN data when it receives the last key (#) press after PIN code. Format: User ID Number Example: User ID number: 56, PIN code: 123456 Press 56 # 123456#, then the output format will be: 00000056 Fingerprint Transmission The Reader will transmit the ID number of the fingerprint after the valid fingerprint input. Format: Device ID + Fingerprint ID Number Example: Fingerprint ID is 123, the Device ID is set 2 Press the fingerprint, the output format will be: 00200123 Card Transmission The Reader will transmit the card data when it reads the Card, no matter the card is valid or invalid. Format: Card Number ( 8 or 10 digits) 11 12