PRA Inc th Place NE Arlington, WA U.S.A.

Similar documents
Model 2553 Passive Network Quartz Crystal Test System

5 to100 Amperes Linear Power Supply/Charger (120 Volt 60Hz) (220 Volt 50Hz)

MANUAL FOR THE UNIVERSAL MANUAL CONTROLLER UMC - 31

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz Product Overview

CheckSum. FUNC-2B Functional Test Module. The FUNC-2B features:

OVEN INDUSTRIES, INC.

MICRO BURN IN PRODUCTS LISTED IN MODEL NUMBER ORDER FOLLOWED BY A BRIEF DESCRIPTION

ES-362U PRESETTABLE MASTER TIMER

SMTmax T-8280 IR Preheating Plate

Programmable D.C. Electronic Load

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

Ultra-Accurate Measurement for Temperature and Voltage

Product Information Sheet PDA14 2 Channel, 14-Bit Waveform Digitizer APPLICATIONS FEATURES OVERVIEW

Ultra-Accurate Measurement for Temperature and Voltage

Pin Configuration and Selector Guide appear at end of data sheet. Typical Operating Circuits

L200 LINE/SUM/MIKE AMPLIFIER OPERATING AND MAINTENANCE MANUAL

2015 SIMMCONN LABS, LLC. All rights reserved. NewScope-T1 Operation Manual

Fluke 8845A/8846A Digital Multimeters. Precision and versatility for bench or systems applications

Keysight U8030 Series Triple-Output DC Power Supplies

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

INSTRUCTION MANUAL. Triple Output DC POWER SUPPLY MODELS 1651A & 1652 MODELOS 1651A & El Manual de la Instrucción

RT4F-110V/25A RECTIFIER

Hypot III. Graphic Liquid Crystal Display. 10 Memories with 3 Steps per Memory. Low Limit Detection System. SmartGFI Circuit (Patent Pending)

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION

SMTmax SMT-6000 IR Preheating Plate

HPA4202 1/5. 2-Channel High Power Multi-Impedance Amplifier. General Description. Features. Applications. AtlasIED.com. HPA4202 Front.

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

Sierra Radio Systems. HamStack. Project Board Reference Manual V1.0

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

Shack Clock kit. U3S Rev 2 PCB 1. Introduction

NWL Pacific Inc PARTS CATALOG

VT-820 VT-820. Temperature Compensated Crystal Oscillator Previous Vectron Model VTM3. Description

RADCOM s Platform Specifications. Valid from Version 7.10

Exclusive 2.5 GHz Frequency Counter

Lab 0: Wire Wrapping Project: Counter Board

Ultra-Accurate Temperature Measurement Instruments

Fluke 8845A/8846A Digital Multimeters. Precision and versatility for bench or systems applications

Part Numbers SNAP-IT-EMU1

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION

Session 4a. Burn-in & Test Socket Workshop Burn-in Board Design

VRM 8.1 DC-DC Converter Design Guidelines

Installation Job Aid for VSP 4850GTS

REMOTE PAGER SYSTEM RACEAIR TM QUICK START GUIDE

The Atmel ATmega328P Microcontroller

PAS 9406/AMP ENGINEERING SPECIFICATION

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

Agilent E1420B Universal Counter. Assembly-Level Service (Also applies to the Agilent E1420A Universal Counter)

RT4F-120V/20A-WAC RECTIFIER

Installation Job Aid for VSP 4450GTX-HT- PWR+

Table of Contents. Lucas Nülle GmbH Page 1/9

RF0250 RF1100 RF1200 RF1300 RF1600

FS2000 Series Fast Switching Synthesizer

Fluke 8845A/8846A Digital Multimeters. Precision and versatility for bench or systems applications

SX90 Process Controller

RT12-240V/2.4kW Rectifier Specification

NEW! 6.5 Digit Precision Multimeter from Fluke

Single-Output 2000 W GPIB

Transcendent Frequency Counter

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

Solid State Battery Fuel Gauge

Logic Analyzers. TLA Family. Ordering Information. Logic Analyzer with External Display.

CDD4 Series Room CO2 Transmitter Installation Instructions

Universal AC Power Source + AC Power Analyzer

BIPOLAR OPERATIONAL POWER SUPPLY

DSP240-LPI Inverter Controller Card. Technical Brief

Agilent E36XXA Series Non-Programmable DC Power Supplies. Data Sheet

TEMPERATURE SENSOR/FAN CONTROL BOARD USER'S MANUAL

CDD4 Duct Carbon Dioxide Transmitter

Modular Power System 1200 W per mainframe GPIB

MODCELL 2050R Single Loop Controllers

CMX18 FEATURES A 18-SLOT 3U PXI EXPRESS CHASSIS

General Purpose Chassis for PXI and CompactPCI

ericssonz LBI-38616B MAINTENANCE MANUAL FOR MTD TM SERIES AND DATA RADIO LOGIC BOARD 19D902151G3 DESCRIPTION CIRCUIT ANALYSIS TABLE OF CONTENTS

INSTRUCTION MANUAL MODELS: 1760A, 1761, Triple Output DC POWER SUPPLY With Dual 4-Digit LED Displays

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

. Modular training system for the fundamentals of digital technology /. . Individual expansion possibilities. Detailed experiment descriptions

The SFP BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD). Datacom Distributed Power Systems

3-60MHZ HF PIC18F2550 USB

MEDTEQ Multi Channel ECG System (MECG) 1.0. Operation Manual

HostEngine 3U Host Computer User Guide

Pacific Antenna Two Tone Generator

ENERGY / POWER METER - digital

CM6800E Matrix Switcher/Controller MICROPROCESSOR-BASED, CROSS-POINT VIDEO SWITCHER, 48 X 8, EXPANDABLE

R&S HMC804x Power Supply 100 W and 1, 2 or 3 Channels

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY I INTRODUCTION

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

CT-400 FEATURES. A Price/Performance Breakthrough for VXI Mainframes. Modular Power Supply Assembly. Over 1100 Watts of Usable Power

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

Page 2 TECPak User s Manual

RT4B-110V/12A RECTIFIER

Drexel University Electrical and Computer Engineering Department ECE 200 Intelligent Systems Spring Lab 1. Pencilbox Logic Designer

Product Information Sheet PX Channel, 14-Bit Waveform Digitizer

Automotive Electronics Council Component Technical Committee

Data Sheet. Thumbwheel Switch Multiswitch, Series B

HostEngine 4U Host Computer User Guide

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

DSP Filter System. Author: Nels Pearson Org Date: July 5, 2007 Rev Date: July 6, Doc Number: AIGO-009

Transcription:

2360 Series Quartz Crystal - Oscillator Aging and Aging Measurement Test System Devices are operating while aging Frequency Measurement made while aging Up to 4000 devices simultaneously in a Model 2360 Oven Up to 2000 devices simultaneously in a Model 2361 Oven Up to 500 devices simultaneously in a user supplied oven for the Model 2362 Up to 4000 devices in a dual high velocity air flow Model 2363 oven Devices placed in aging boards Measurement cycles and rate of reading are set by the user Frequency change versus time can be plotted Aging temperature range: 50 o C to 125 o C System controlled by a P.C. Model 2360 PRA Inc. 4821 226 th Place NE Arlington, WA 98223 U.S.A. TEL: 360-435-0484 e-mail:sales@prainctest.com www.prainctest.com 2360 Series Systems Page 1

System Features The 2360 Series Aging System permits aging crystals and clock oscillators at a user set temperature while the devices are oscillating. The system consists of: Rectangular oven that has up to 8 slide out racks. Each slide out rack holds 2 aging boards. PRA Power Supply and Multiplexer. Provides power to the aging boards and provides the interface between the controlling PC and all of the aging boards. The PRA Power Supply Multiplexer provides a clock and data signal to the aging board. The computer sends a data string serially to the card to select the one oscillator Period averaging frequency counter for high resolution with fast measurement times. Fail Safe thermostat sensor for the chamber. The sensor shuts down all power supplies to the aging boards if the chamber fails or exceeds a user set temperature. Each aging board has AC cut crystals placed in 2 positions. These crystals are used as quartz thermometers to measure the change in aging temperature. The aging temperature can Model 2361 position on the card to be read. This signal is sent via 50 ohm coaxial cable to the Model 512 and then to the frequency counter. (Optional) PRA Add On Power Supply. Required to operate 8 aging board positions, permits full 16 board operation. The system is controlled by a PC. Model 2362 be logged as part of the data. The data reduction software permits analysis of the short term temperature changes on the measured frequency data. The effect of temperature change can be removed from the plots and printouts of the data. Equivalent chamber stabilities of 0.0025 o C have been achieved. Each aging board contains the needed multiplex circuitry to permit selecting only 1 DUT on the PCB to measure. The on-board multiplexing is designed to minimize inter DUT signal radiation so precise measurements can be made. The aging boards may be partially withdrawn from the system to remove or add DUT s. The power supply connections are retained so that aging of other devices can continue uninterrupted. The slide out rack design also minimizes heat loss to the racks that are not extended. There are different aging boards 2360 Series Systems Page 2

for various applications. The system is controlled by software supplied as part of the system. All test parameters are entered through menu driven programs. All entered test procedures are stored on the system controller s disk. To measure an already defined part requires the operator to select the desired specification from a menu and then testing begins. All equipment setup is auto- Device Aging Boards matic. The system can be loaded with may different groups of devices. Groups of devices can be loaded/unloaded at any time and the status of the other groups in the system is unaffected. The aging status of any crystal can be displayed or printed at any time. The data can be in graphical or tabular form. The system is network compatible. The system can accept several types of aging boards. Any mixture of the board types is allowed. Each board is powered by: 5 volt 7 Amp supply +12 volt 7 Amp supply (optional) -12 volt 0.6 Amp supply (optional) The aging board is held in the slide out rack assembly. When the aging board is plugged into the rack; the aging board receives power, the computer control signal and Model 2363 outputs the selected DUT signal. Wide Band Universal Crystal Oscillator Aging Board: Devices to test are mounted in sockets on the burn-in board. Up to 254 crystals per board. TO5, HC45, HC49, UM1 packages. The Fairchild Semiconductor wide band clock oscillator circuit, part CGS3311, is capable of properly operating to about 80MHz fundamental crystals. The circuit is a wide band device and normally will operate the crystal on the fundamental. In some cases, the overtone mode may be lower in resistance and the oscillator will operate on the harmonic. Drive level typically 150uW. Aging oven with the door open. Each slide rack has an air flow baffle to isolate the other aging boards when the door is open or the slide is out. 2360 Series Systems Page 3

Oven slide rack extended with Wide Band Crystal Aging boards installed. 2360 Series Systems Page 4

High Frequency Aging Board: The board tests 254 crystals with a fundamental frequency range of 70Mhz to over 225MHz. The crystals are operated in a wide band untuned oscillator. TTL/HCMOS DIP/DIL Clock Oscillator Aging Board: 254 Full Size or Half Size Devices to test are mounted in sockets on the burn in board. The board permits testing both ECL, TTL and HCMOS parts. The upper frequency range is over 1 GHz. On the PCB are buffer circuits so the DUTs do not drive long leads. The output signal is prescaled to improve isolation and measurement accuracy. QPL Type TTL/HCMOS DIP/DIL Clock Oscillator Aging Board: The board permits testing 126 Full Size or Half Size devices. The board can be set to have standard TTL or HCMOS loads. The loads are hard soldered on the boards. The upper frequency range is 100MHz. 40 Pin LCC Aging Board: The 98 devices to test are mounted in sockets on the burn in board. The board permits setting standard TTL or HCMOS loads. The loads are hard soldered on the boards. The upper frequency range is 100MHz. SMD Aging Boards: Contact PRA about your specific needs. Test Time and Test Sequences The user can program the counter gate time (resolution) and how often to read a DUT. Each position in the chamber can have a unique test sequence. Assuming 10ppb resolution is desired, a read time of 0.1S per device would be needed. The test time for a fully loaded system would be approximately 10 minutes. The system permits a mixture of aging sequences. Some parts can be measured hourly, other parts can be measured monthly. These sequences are defined by the system user. Any measurement interval greater than the required measurement time is permitted. 2360 Series Systems Page 5

System Configuration Model 2360 System (4000 Devices Maximum): The system (8 aging board positions and an optional 8 more board positions) consists of the following: Oven: Lab Line Oven Inside: 23w x 17.1d x 19.5h (in) 57.5w x 42.8d x 48.7h (cm) Outside: 31.7w x 29.5d x 35.5h (in) 79w x 74d x 89h (cm) LFE Mark IV Industries Controller PID type temperature control RTD sensor Power Supply: PRA Model 512 powers the multiplexers and aging boards. Mounted on the rear of the oven. Optional: Model 513 power supply and slide rack kit. This increases the capability to a full 16 aging boards. Model 2361 System (2000 Devices Maximum): The system (4 aging board positions and an optional 4 more board positions) consists of the following: Oven: Lab Line Oven Inside: 13w x 17.1d x 19.5h (in) 32.5w x 42.8d x 48.7h (cm) Outside: 21.6w x 25.3d x 35.5h (in) 54w x 63.1d x 88.7h (cm) LFE Mark IV Industries Controller PID type temperature control RTD sensor Power Supply: PRA Model 514 powers the multiplexers and aging boards. Mounted on the rear of the oven. Optional: Model 515 power supply and slide rack kit. This increases the capability to a full 8 aging boards. Model 2362 System (254 or 508 Devices Maximum) The system (1 or 2 aging board positions) and a customer supplied oven consists of the following: Power Supply: PRA for one or two aging positions. Bench Mounted on the rear of the oven. Model 2363 System (4000 Devices Maximum): The system (8 aging board positions) which are in one high air flow oven. An optional second oven can be added to reach the full 4000 DUTs. The system consists of the following: Oven: Blue M Oven LFE Mark IV Industries Controller PID type temperature control RTD sensor Power Supply: Mounted on the rear of the oven. All Systems--- Controlling PC: Windows XP Pro PC with COM port. Counter: Agilent/HP53181, 53131, 53132. Data reduction software Cables Manuals Aging boards: As needed. Installation requirements: 195 to 240VAC, 50/60Hz (2 mains cords) Oven power: 8 Amps maximum DUT Power: 10 Amps maximum 95 to 125VAC, 50/60Hz (2 mains cords) Oven power: 16 Amps maximum DUT Power: 20 Amps maximum Frequency Standard: 10MHz 150mV RMS minimum Sine wave or 450mV PP minimum square wave 500ohm load. Stability of better than 1 ppb aging per year. NOTE: PRA Inc. reserves the right to make changes to the product contained in this data sheet in order to improve the design or performance and to supply the best possible product. PRA Inc. reserves the right to make these changes without notice. Revised 9/22/07 2360 Series Systems Page 6