PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Similar documents
PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

STEP-PS/1AC/24DC/1.75

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 01/2007

MINI-PS AC/10-15DC/8

TRIO-DIODE/12-24DC/2X10/1X20

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

QUINT-PS-3x AC/24DC/10

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

QUINT-BUFFER/24DC/24DC/40

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description

QUINT-PS AC/24DC/10

1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas QUINT-PS AC/24DC/5/EX

QUINT-PS/ 1AC/24DC/ 5

QUINT-PS/24DC/48DC/ 5

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Power supply CP-C 24/5.0

QUINT-PS/ 1AC/24DC/20/CO

ASI QUINT /2.4 EFD

STEP-PS/1AC/24DC/2.5. Extract from the online catalog. Order No.: DIN rail power supply of 24 V DC/2.5 A, primary switched, single phase.

Extract from the online catalog

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

Redundancy Module QUINT-DIODE/40

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Power Supply HARTING pcon

Power supply CP-E 24/10.0 Primary switch mode power supply

Power supply CP-E 48/1.25 Primary switch mode power supply

Power supply CP-E 24/0.75 Primary switch mode power supply

Redundancy unit CP-A RU

Power Supply HARTING pcon

onlinecomponents.com

Uninterruptible Power Supply Unit for Universal Use QUINT-DC-UPS/24DC/40

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

Power supply CP-D 12/2.1 Primary switch mode power supply

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.:

DC/DC converters - QUINT-PS/24DC/24DC/

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Uninterruptible power supply - TRIO-UPS/1AC/24DC/

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Power supply CP-C 24/5.0

Rhino PSM Power Supplies. Operating Instructions

MINI MCR-SL-UI-2I(-SP)(-NC)

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

MINI MCR-SL-PT100-UI(-SP)(-NC)

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

FL MC 2000E (SM40) LC

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

AO561 Analog Output Module

AI561 Analog Input Module

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

DC561, digital input/output module,

DC562, digital input/output module,

Switched-Mode Power Supplies. 5, 12, 18, 48 VDC Output

EMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description.

PHOENIX CONTACT - 12/2007

20A DRR Module / 40A DRR Module

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-CVS NC

Industrial Power Supplies

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-120VAC

Output Voltage* (nom.)(adjustable)

DX561 Digital Input/Output Module

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

AO523 Analog Input Module

Contact protection relay

MINI MCR-SL-PT100-UI-200

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

QUINT-UPS/ 24DC/ 24DC/10

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

24V 100W 1 Phase PMC-24V100W1AA

DI561 Digital Input Module

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

MINI MCR-SL-UI-REL(-SP)

PHOENIX CONTACT - 05/2007

DI572 Digital Input Module

Output Voltage* (nom.)(adjustable)

MACX MCR-EX-SD LP(-SP)

ETD-BL-1T-OFF-CC- 10S

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

CI542 PROFIBUS Communication Interface Module

Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

DC541 Digital Input/Output Module

PHOENIX CONTACT Features

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

Transcription:

Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions. With an output voltage of 24 V DC and 1-phase and 3-phase versions with 60 W or 960 W, it is particularly suited for use in series production in mechanical engineering. The wide-range input and international certification package allows worldwide implementation. The high MTBF of 500,000 h stands for high supply reliability. The devices can be connected in parallel to increase the capacity and redundancy. The clear LED signaling and the device connection with double terminal block for plus and minus for fast potential distribution are further advantages of this device series. A third terminal block for minus simplifies the grounding on the secondary side. All power supply units are idle proof and short circuit proof and provide a regulated and settable output voltage of 22.5 V DC to 29.5 V DC with output currents of 2.5 A, 5 A, 10 A, 20 A or 40 A. Reliable power supply unit even at high ambient temperatures No load and short circuiting resistance High dielectric strength Can be used worldwide in all industrial sectors due to a wide-range input and an international approval package DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. DANGER Components with dangerously high voltage and high stored energy are located in the device! Never carry out work on live parts! Depending on the ambient temperature and the load, the housing can become very hot! Make sure you always use the the latest documentation. It can be downloaded at www.download.phoenixcontact.com. A conversion table is available on the Internet at www.download.phoenixcontact.com/general/7000_en_00.pdf.

Table of contents Description...1 Table of contents...2 Order data...3 Technical data...3 Structure...6 Block diagram...7 Safety and warning notes...7 Installation...8 Installation position...8 Assembly...9 Removing...9 Connection to various network forms...9 Input...10 Protection of the primary side...10 Required backup fuse (device and line protection)...10 Output...11 Protection of the secondary side...11 Signaling...11 Function...12 Output characteristic curve...12 Thermal behavior...12 Parallel operation...13 102782_01_en PHOENIX CONTACT 2

Order data Description Type Order No. Pcs./Pkt. Primary switched power supply, 3-phase, output current: 40 A TRIO-PS/3AC/24DC/40 2866404 1 Accessories Type Order No. Pcs./Pkt. Universal wall adapter UWA 182/52 2938235 1 Technical data Input data Input nominal voltage range 2x / 3x 400 V AC... 500 V AC AC input voltage range 320 V AC... 575 V AC (for 3-phase operation) 2x 360 V AC... 575 V AC (for 2-phase operation) AC frequency range 45 Hz... 65 Hz Current consumption 3x 2 A (400 V AC) 3x 1.6 A (480 V AC) Inrush current limitation < 20 A I 2 t 1.3 A 2 s Power failure bypass > 16 ms (400 V AC) > 20 ms (480 V AC) Typical response time < 1 s Power factor (cos phi) 0.76 Protective circuitry Transient surge protection Varistor Recommended backup fuse for mains protection 3x 10 A (characteristic B) 3x 16 A (characteristic B) Required backup fuse (device and line protection) (externally via 3 10 A or 16 A circuit breakers, characteristic B) Discharge current to PE < 3.5 ma Output data Nominal output voltage 24 V DC ±1% Setting range of the output voltage 22.5 V DC... 29.5 V DC Output current 40 A (-25 C... 55 C) Derating Above 55 C: 2.5% per Kelvin Current limitation Approx. 48 A Max. capacitive load Unlimited Control deviation < 1 % (change in load, static 10%... 90%) < 2 % (change in load, dynamic 10%... 90%) < 0.1 % (change in input voltage ±10%) Power loss nominal load max. 87 W Maximum power dissipation idling 11 W Efficiency > 91.5 % Ascent time < 2 ms (U OUT (10%... 90%)) Residual ripple < 20 mv PP Peak switching voltages < 40 mv PP Connection in parallel Yes, for redundancy and increased capacity Connection in series No Surge protection against internal surge voltages Yes, < 35 V DC Resistance to reverse feed 35 V DC 102782_01_en PHOENIX CONTACT 3

Signal output DC OK active Status display "DC OK" LED green / U OUT > 21.5 V: LED lights up General data Insulation voltage input/output 4 kv AC (Type test) 2 kv AC (routine test) Insulation voltage input / PE 2 kv AC (type test) 2 kv AC (routine test) Insulation voltage output / PE 500 V DC (routine test) Degree of protection IP20 Class of protection I, with PE connection MTBF > 500 000 h in acc. with IEC 61709 (SN 29500) Housing version Steel sheet, zinc-plated Side element version Aluminum Dimensions W / H / D (state of delivery) 139 mm / 130 mm / 190 mm Weight 3.2 kg Ambient conditions Ambient temperature (operation) -25 C... 70 C (> 55 C derating) Ambient temperature (storage/transport) -40 C... 85 C Max. permissible relative humidity (operation) 95 % (at 25 C, no condensation) Vibration (operation) < 15 Hz, amplitude ±2.5 mm in acc. with IEC 60068-2-6 15 Hz... 150 Hz, 2.3g, 90 min. Shock 15g in all directions in acc. with IEC 60068-2-27 Pollution degree in acc. with EN 50178 2 Climatic class 3K3 (in acc. with EN 60721) Standards Electrical Equipment for Machinery EN 60204 Safety transformers for power supply units EN 61558-2-17 Electrical safety (of information technology equipment) EN 60950/VDE 0805 (SELV) EN 61558-2-17 Electronic equipment for use in electrical power installations EN 50178/VDE 0160 (PELV) SELV EN 60950 (SELV) EN 60204 (PELV) Safe isolation DIN VDE 0100-410 DIN VDE 0106-1010 Protection against electric shock DIN 57100-410 Protection against electric shock, basic requirements for safe isolation in DIN VDE 0106-101 electrical equipment Limitation of mains harmonic currents EN 61000-3-2 Approvals UL rating UL Listed UL 508 UL/C-UL Recognized UL 60950 102782_01_en PHOENIX CONTACT 4

Conformance with EMC directive 89/336/EEC Immunity to interference in acc. with EN 61000-6-2 Discharge of static electricity Electromagnetic HF field Fast transients (burst) Surge current loads (Surge) Conducted interference Voltage dips Housing Level 3 Contact discharge 6 kv Discharge in air 8 kv Comments Criterion B Housing Level 3 Frequency range 80 MHz... 3 GHz Field intensity 10 V/m Comments Criterion A Input Output Comments Input/Output Comments Input/output Frequency range Voltage Comments Input Comments 4 kv (level 4 - asymmetrical: conductor to ground) 2 kv (level 3 - asymmetrical: conductor to ground) Criterion A 4 kv (level 4 - asymmetrical: conductor to ground) 2 kv (level 4 - symmetrical: conductor to conductor) Criterion A Level 3 - asymmetrical 0.1 MHz... 80 MHz 10 V Criterion A (mains buffering > 10 ms) Criterion B Emitted interference in acc. with EN 61000-6-3 Radio interference voltage in acc. with EN 55011 Emitted radio interference in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential EN 55011 (EN 55022) Class B, area of application: Industry and residential 102782_01_en PHOENIX CONTACT 5

Structure 5 1 AC input 2 DC output 3 Potentiometer 22.5 V DC... 29.5 V DC 4 "DC OK" LED 5 DIN rail adapter 6 Take-up for cable binders 1 Input 2/3 AC 400-500 V L1 L2 (L3) PE DC OK Adjust 22.5-29.5 V Output DC 24 V 40 A - - - TRIO POWER TRIO-PS/3AC/24DC/40 Order-No.: 2866404 Input: 3x 400-500 V~ /3x2.8-2.2 A/50-60 Hz Operational Voltage: 3x320-575V~ Output: 24 V / 40A APPROVALS UL LISTED -25... 70 C >55 C -13... 158 F >131 F INDUSTRIAL CONTROL EQUIPMENT 43KA Derating: 2,5%/K Read installation instructions before connecting to mains EN 61000-6-2 EN 61000-6-3 www.interface.phoenixcontact.com 6 [mm 2 ] AWG [Nm] solid stranded Torque Input 0.2-6 0.2-4 22-10 0.5-0.6 Output 0.5-16 0.5-10 8-6 1.2-1.5 2 4 3 Input data Input nominal voltage range AC input voltage range AC frequency range 2x / 3x 400 V AC... 500 V AC 320 V AC... 575 V AC (for 3-phase operation) 2x 360 V AC... 575 V AC (for 2-phase operation) 45 Hz... 65 Hz Recommended backup fuse for mains protection 3x 10 A (characteristic B) 3x 16 A (characteristic B) Required backup fuse (device and line protection) (externally via 3 10 A or 16 A circuit breakers, characteristic B) Type of connection Stripping length Output data Screw connection 8 mm Nominal output voltage 24 V DC ±1% Setting range of the output voltage 22.5 V DC... 29.5 V DC Output current 40 A (-25 C... 55 C) Type of connection Screw connection Stripping length 10 mm 102782_01_en PHOENIX CONTACT 6

Block diagram L1 L2 (L3) PE Safety and warning notes The power supply units are built-in devices. The device may only be installed and put into operation by qualified personnel. The corresponding national regulations must be observed. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. DANGER Components with dangerously high voltage and high stored energy are located in the device! Never carry out work on live parts! Depending on the ambient temperature and the load, the housing can become very hot! Before startup please ensure: The mains connection has been carried out by a competent person and protection against electric shock is guaranteed! The device can be disconnected outside the power supply unit in accordance with the regulations as in EN 60950 (e.g. through primary side line protection)! The ground conductor is connected! All feed lines are sufficiently protected and dimensioned! All output lines are dimensioned according to the maximum output current of the device or separately protected! Sufficient convection is guaranteed! 102782_01_en PHOENIX CONTACT 7

Installation In order to guarantee sufficient convection, we recommend observing the following minimum distance to other modules: 5 cm in a vertical direction and 0 cm in a horizontal direction. The power supply unit can be snapped onto all DIN rails in acc. with EN 60715. They must be mounted horizontally (connecting terminal blocks bottom). Input 2/3 AC 400-500 V L1 L2 (L3) PE DC OK Adjust 22.5-29.5 V Output DC 24 V 40 A - - - TRIO POWER APPROVALS UL LISTED INDUSTRIAL CONTROL EQUIPMENT 43KA Read installation instructions before connecting to mains TRIO-PS/3AC/24DC/40 Order-No.: 2866404 Input: 3x 400-500 V~ / 3x2.8-2.2 A / 50-60 Hz Operational Voltage: 3x 320-575 V~ Output: 24 V / 40A -25... 70 C >55 C -13... 158 F >131 F Derating: 2,5%/K EN 61000-6-2 EN 61000-6-3 www.interface.phoenixcontact.com 139 115 50 Installation position DC OK TRIO POWER 230 Adjust 22.5-29.5V 130 Input 2/3 AC 100-240 V Output DC 24 V 20 A L1 L2 (L3) PE Mounting position: Installation depth 190 mm ( DIN rail) 102782_01_en PHOENIX CONTACT 8

A B Assembly Position the module with the DIN rail guide on the upper edge of the DIN rail, and snap it in with a downward motion. Removing Pull the snap lever open with the aid of a screwdriver and slide the module out at the lower edge of the DIN rail. B A Connection to various network forms TN-S TN-C TT it L1 L2 L3 N PE L1 L2 L3 PEN L1 L2 L3 N L1 L2 L3 L1 L2(L3) PE L1 L2(L3) PE L1 L2(L3) PE L1 L2(L3) PE The connection for 2x/3x 400 V AC... 500 V AC is made using the L1, L2, L3 and PE screw connections. The device can be connected to 2/3-phase AC networks with nominal voltages 2x/3x 400 V AC... 500 V AC. In the event of a phase failure, unrestricted operation is possible with nominal capacity. In order to comply with the UL certification, use copper cables that are designed for operating temperatures of > 75 C. In order to comply with EN 60950/UL 60950, flexible cables require ferrules. To safely connect a device, the ferrules should have a length of at least 10 mm (AC input) or 12 mm (DC output). To achieve a reliable and shockproof connection, strip the connecting ends according to section "Structure". 102782_01_en PHOENIX CONTACT 9

Input Protection of the primary side The device must be installed in acc. with the regulations as in EN 60950. It must be possible to disconnect the device using a suitable isolating facility outside the power supply. Primary circuit mains protection, for example, is suitable for this purpose. Required backup fuse (device and line protection) Input 2/3 AC 400-500V L1 L2 (L3) PE DC OK Adjust 22.5-29.5 V Output DC 24V 40 A - - - TRIO POWER TRIO-PS/3AC/24DC/40 Order-No.: 2866404 Input: 3x 400-500 V~ / 3x2.8-2.2 A / 50-60 Hz Operational Voltage: 3x 320-575 V~ Output: 24 V / 40A -25... 70 C >55 C -13... 158 F >131 F APPROVALS UL LISTED INDUSTRIAL CONTROL EQUIPMENT 43KA Derating: 2,5%/K Read insta lation instructions before connecting to mains EN 61000-6-2 EN 61000-6-3 www.interface.phoenixcontact.com Three external thermo-magnetic fuses are necessary as device protection: 3 x 10 A or 16 A power circuit breaker, characteristic B (or identical function). If an external fuse is triggered, there is most probably a malfunction in the device. In this case, the device must be inspected in the factory! 102782_01_en PHOENIX CONTACT 10

Output Make sure that all output lines are dimensioned according to the maximum output current or are separately protected. The cables on the secondary side must have sufficiently large cross sections in order to keep the voltage drops on the lines as low as possible. Input 2/3 AC 400-500 V L1 L2 (L3) PE DC OK Adjust 22.5-29.5 V Output DC 24 V 40 A - - - TRIO POWER TRIO-PS/3AC/24DC/40 Order-No.: 2866404 Input: 3x 400-500 V~ / 3x2.8-2.2 A / 50-60 Hz Operational Voltage: 3x 320-575 V~ Output: 24 V / 40 A -25... 70 C >55 C -13... 158 F >131 F APPROVALS UL LISTED INDUSTRIAL CONTROL EQUIPMENT 43KA Derating: 2,5%/K Read insta lation instructions before connecting to mains EN 61000-6-2 EN 61000-6-3 www.interface.phoenixcontact.com You can fasten the connection cables to the housing using cable binders. Ensure that the cable binders and the connection cables are designed for the surface temperatures that occur in operation. Make sure that the insulation of the connection cables is not damaged when tightening the cable binders. The connection is made using the "" and "-" screw connections on the screw connection of the DC output. At the time of delivery, the output voltage is 24 V DC. The output voltage can be set on the potentiometer. Protection of the secondary side The device is electronically protected against short circuit and idling. In the event of a malfunction, the output voltage is limited to 35 V DC. Signaling The "DC OK" LED enables evaluation of the function of the power supply directly on site. State 1 State 2 "DC OK" LED ON OFF Cause Output voltage > 21.5 V Output voltage < 21.5 V or no voltage at the output Meaning Output voltage and output current OK TRIO POWER is in operation, but there is a fault on the side of the consumer; the current consumption is greater than I N or the output is short circuited. TRIO POWER is out of operation because there is no mains voltage, the fuse on the primary side has been triggered, or the device is faulty. 102782_01_en PHOENIX CONTACT 11

Function Output characteristic curve The device functions following the U/I characteristic curve. Under load, the working point follows this curve. The output current is limited in the event of a short circuit or overload. Thereby, the device does not switch off, but rather supplies a continuous output current. The secondary voltage is reduced until the short circuit or overload on the secondary side has been remedied. The U/I characteristic curve ensures that both heavily capacitive loads and loads with DC/DC converters in the primary circuit can be supplied. Downstream fuses are triggered. Selectivity in the design of your system is guaranteed at all times. U N = 24 V I N = 40 A P N = 960 W U [V] OUT U N I N I OUT [A] Thermal behavior Output current [A] I N 0 0 20 40 60 Ambient temperature [ C] With an ambient temperature of up to 55 C, the device supplies the continuous output current of I N. In the case of ambient temperatures above 55 C, the output current must be reduced by 2.5% per Kelvin increase in temperature. The device does not switch off at ambient temperatures of 70 C or thermal overload. The output capacity is reduced as far as necessary to provide device protection. After it has cooled down, the output capacity is increased again. 102782_01_en PHOENIX CONTACT 12

Parallel operation Devices of the same type can be connected in parallel to enable both redundancy and an increase in efficiency. No other alignment is necessary when in the state of delivery. If the output voltage is adjusted, a uniform distribution of power is guaranteed by setting all parallel operated power supply units to exactly the same output voltage. To ensure symmetrical distribution of power, we recommend designing all cable connections from the power supply unit to a busbar of the same length and with the same conductor cross section. The system makes it advisable to install a protective circuit at the output of each device when more than two power supply units are connected in parallel (e.g. decoupling diode or DC fuse). This prevents high reverse feed currents in the event of a secondary device fault. Redundant operation I N I N Σ =I N Redundant circuits are suitable for the supply of systems which make especially high requirements on the operational safety. If a fault occurs in the primary circuit of the first power supply unit, the second device automatically takes over the entire power supply, without interruption, and vice versa. For this reason, the power supply units to be connected in parallel are dimensioned in such a way that the total current requirement of all consumers can be completely covered by one power supply unit. 100% redundancy makes external decoupling diodes necessary (QUINT-DIODE/40, Order No. 2938963)! I N I N Increased performance For n parallel connected devices, the output current can be increased to n x I N. Parallel connection to increase efficiency is used for the expansion of existing systems. It is advisable to use parallel connection if the power supply unit does not cover the current requirement of the most powerful consumer. Otherwise the consumers should be spread among individual devices independent of one another. A maximum of five devices can be connected in parallel! Σ =2xI N 102782_01_en PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg Germany 13 Phone: 49-(0) 5235-3-00 Fax: 49-(0) 5235-3-4 12 00 www.phoenixcontact.com