Vibration-Resistant Weighing Indicator

Similar documents
Performs many operations, from batch weighing to field bus networking applications.

AD-4401 WEIGHING INDICATOR A-IE

AD Weighing Indicator INSTRUCTION MANUAL 1WMPD A

C500 Series Data Sheet

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

EXCELL PRECISION CO., LTD.

EMC ModWeigh MW61B. Mk2 & Mk3 Weigher System. Application. MW99 Weight Indicator. MW61B_Brochure_Issue_11b EMC INDUSTRIAL GROUP LTD

PENKO Engineering B.V. When Weighing Counts FLEX Multi Channel Extended

Characteristics and functioning

Business. Republic of SEWHACNM to the world beyond. 1 2 Industrial Automation

AD-4532B. Digital Indicator INSTRUCTION MANUAL 1WMPD A

UniPak UP448 Bridge Input Isolating Signal Conditioner

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module

LC0 DVP

WTX110. Legal-for-trade industrial weighing terminal. Special features. Data sheet

This document hosted by: Extension Load Cell Cable (OP-02)

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

MODEL 9250 Preliminary data sheet

BT3563/BT3562/3561. BATTERY HiTESTER

Characteristics and functioning

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

21e Multi-Function Indicator

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

EC Type Examination Certificate

Microprocessor Resistivity & Conductivity Monitor/Controller EC410 / EC430. Operation Manual

WUNDER SA.BI.SRL EN USER MANUAL. MULTIFUNCTIONS ELECTRONIC SCALE MOD. W100 LED. User Manual

EU Type Examination Certificate

digiclip Data sheet DF31DP Special features B en

WTX120. Legal-for-trade industrial weighing terminal. Special features. Data sheet

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

DC-204R DC-204Ra SMART DYNAMIC STRAIN RECORDER. 200kHz 2GB UPS. Strain DC voltage Temperature. TML Pam E-442B. capacity. High speed sampling

Process displays For current and voltage

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

D-500s Indicator D LED. User Instructions. English Issue September SangR. Page 2. User s manual of Sang D-500s LED

CJ1W-PTS/PDC/PH41U/AD04U

DIGITAL PRESSURE SENSOR SCANNER CUM DATALOGGER

Technical Parameter... 4 Installation and Connection... 5

E4PA. Ultrasonic Displacement Sensor. Ordering Information

IO-LC1, IO-LC3 I/O Expansion Modules 1-3 Loadcell Inputs, 1 Digital In, 2 Out

DRAFT. Customer site gravity factor. Filtering parameters. Five points for linearity correction to ensure maximum accuracy

Single-output and dual-output power supplies. TOE 8840 up to 160 W TOE 8850 up to 320 W. In-phase regulation

Please keep the following using conditions certainly

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

digiclip Data sheet DF31CAN Special features B en

Digital Weighing Indicator XK3190-A12 User Manual

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

CAUTIONS... 4 INTRODUCTION...

2-2 Testing space Tension and Compression test can be available at the lower section of movable crosshead. Upper tension type : Sold separately.

Sartorius Research. R 160 P Electronic Semi-Microbalance

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

USER S GUIDE. Weighing Indicator. globalindustrial.com. Use of RS232 Port Using Windows for the Printer Driver, Adjust Computer Settings as Follows:

" User s Manual. Adash 3900-II Online Vibration Monitoring System. Applications: Characteristics:

CALYS 50. Field multifunction calibrator for basic use. Calibration measurement

! User Manual Rev. 1

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website:

Table of Contents. 3-1 Specifications & Features Front Panel Display Keyboard. 3-3 Rear Panel. 3-4 Power Supply. 4.

QC-3265 Checkweigher User s Manual

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

Calibration & Connectivity

DCS Series. Digital Counting Scale. Setup Manual

FlexiLogics PLC Expansion Modules for FL004 ECO Series

DINALOG A 144 x 36 A1400 Light-Strip Indicator

Cảm ơn các bạn đã tham khảo tài liệu cân điện tử từ CÂN ĐIỆN TỬ GIA PHÁT!

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

N420 R420 R423. series

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

SystempaK (Digital/File Type) Dual Input Arithmetic Relay Module Model J-SCM 92/97

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

DIGITAL INDICATING CONTROLLER

SWISS MADE. Series 320 XT PREMIUM. Analytical. Precision

BS-105 Digital Indicator

ACTIONI/Q Q498. DC Powered DC Input Field Configurable Isolator with Math Functions

PCD-400A/430A. Sensor Interface. Carrier Wave Type Compact and Moderate Prices. Data Recorders/Analyzers MEASURING INSTRUMENTS

Table of Contents 1. Introduction Features & Main function Technical Specification Measure of Appearance...

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website:

NTS-4840 Instruction Manual

AD Remote Controller INSTRUCTION MANUAL WM+PD A

After unpacking, check the GL820's Exterior to make sure that there are crack or other damage before use.

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Series Watt DC Power Supplies

R310 & N310 R320 & N320 Digital Indicator

CERTIFICATE of EU TYPE-APPROVAL

BT3563/BT3562/3561. BATTERY HiTESTER

Multi-range pressure and differential pressure transmitter

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

Strain Gauge Converter

DIGITAL TORQUE METER MODEL TME2

Sartorius XQ 6100, XQ 6100 B.

Trident and Trident X2 Digital Process and Temperature Panel Meter

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

EC Type-Approval Certificate

Option 2. Nil. Note 1) Option 1. Note With waterproof seal and mounting screw. With waterproof seal and mounting screw. 48 conversion adapter

CHAPTER 1. Introduction Introduction 3

LH-50. High-precision measurement using safe LED beam LED TYPE OPTICAL DISPLACEMENT SENSOR. LH01caE0(00/6/28) 01.2.

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

System StrainSmart Data Acquisition System. Micro-Measurements FEATURES DESCRIPTION MODEL 5100B SCANNER SPECIFICATIONS

Transcription:

Vibration-Resistant Weighing Indicator Powerful vibration-cancelling function (High Performance Digital Filter) High speed sampling (100 times/second)/high accuracy Circuits equipped with powerful noise reduction Accurate linear correction function using high-order equations Average holding function http://www.aandd.jp Clearly a Better Value

We've Added some Brand-New Functions! Average Holding Function This function allows averaging a specified interval of data and holding it. This mode is convenient for situations where reliable data cannot be taken even when the High Performance Digital Filter is used, like when measuring the weight of a restless animal or something that is fluctuating in weight. In addition to the average holding function, normal hold and peak hold functions can also be selected. The hold start point can be selected based on one's needs, for example, using an external signal, using the F key on the front, or timing it to when the zero band has been exceeded. Awaiting average Averaging out Hold display Hold command Averaging start point Averaging complete Hold release Hold LED flashes Hold LED on Industry First Non-Linear Correction Using High-Order Equations Due to the nature of weighing instruments, sometimes linear deviation can occur even if zero and span calibration are carried out. This correction function minimizes those linearity deviations. Up until now, linear correction has been commonly used, but AD-4410 corrects linearity deviations that linear correction can't compensate for by using high-order curves, enabling more accurate weighing. Weighing value Non-linear correction using high-order equations Before correction High-order equation-based correction Characteristics of the load cell Weighing value Zero Correction point 1 Correction point 2 Correction point 3 Output Conventional linear correction Correction point 4 Linear correction Zero Output Weighing value Before correction Zero Correction point 1 Correction point 2 Correction point 3 Correction point 4 Output

The AD-4410 has 3 input points and 3 output points for its control I/O. Users can select what functions to assign to the control I/O. We've put in two new functions: user input and user input/output. User input/output can be used for whatever purpose the user wishes. One could turn on certain output terminals using RS-232C or RS-485 commands, or confirm certain Input/output terminals' situations using the front panel's display. For example, it would be useful in a situation where you want to monitor photosensor input using PC or PLC, but there's no readable input port available. User Input, User Output From sensors and devices To devices Open collector or non-voltage connection Control I/O input Open collector Control I/O input RS-232C or RS-485 Command is used to confirm whether control I/O input is on or off Response with control I/O status RS-232C or RS-485 Command is used to turn control I/O output on or off Response with control I/O status PLC PLC Extensive Connectivity Control I/O, RS-232C, and current loop all come standard, RS-485 and the second RS-232C channel are options. There are 3 input and 3 output points, and you can freely select from 13 types of input functions and 18 types of output functions. PLC RS-232C or RS-485 3 control inputs 3 control outputs Current loop External display Printer Comparator Function One can establish an upper and lower limit, and use the control I/O output to output HI, OK, or LO. RS-232C Comes Standard with Optional RS-232C/RS-485 Functionality Data can be transmitted at high speed and commands essential to weighing can be sent. Control commands such as hold point commencement and release, setting commands such as upper and lower limits, and weighing data uptake functionality are built-in. Additional Functions Zero Band Detection Function Zero Tracking Function Power On-Zero Function Gravity Acceleration Correction Dual Range This function allows setting a zero band, so that gross weight or net weight will be adjusted to zero within that range. Automatically tracks gross weight zero fluctuations, constantly maintaining gross weight at zero. Automatically sets gross weight to zero when power is switched on. When the area the balance was calibrated using weights at and the area where measurement takes place are far apart, entering the gravity acceleration can correct for inconsistencies. By setting two weighing ranges and changing the scale interval displayed, you can create a multi-interval instrument.

Example of use of the vibration-eliminating High Performance Digital Filter (HPDF) Weighing while inducing vibration Using HPDF Weighing while raising and lowering Weighing unstable objects Using HPDF with averaging hold When containers with liquids are moved on a rolling conveyor with built-in weighing scale, the moment of inertia transferred after stopping the movement means the liquid inside will take a long time to settle and weighing cannot be performed for some time. However, if HPDF with averaging hold is used weighing can be performed instantly. Furthermore, If comparator output is used, the scale can immediately judge whether the measurement is within or outside range and output judgement. Body weight measurement of animals moving about vigorously Weighing unstable objects Weighing while mixing Simple checkweigher A checkweigher (which measures an object while it continues to move) can be created. When the weight exceeds a value outside the zero band, the peak hold function starts, and is released by a timer. Using HPDF with peak hold When HPDF is used, as the effects of vibration are eliminated, the peak value can be taken as the weight of the measured object. Peak value Peak value Real value Real value Load Time Peak value when HPDF is used Load Time Peak value when HPDF is not used If comparator output is used, the scale can immediately judge whether the measurement is within or outside range and output judgement.

High Performance Digital Filter Featuring the Newly Developed High-Performance Digital Filter (HPDF) for Environments with Vibration Issues Powerful Vibration Cancelling Feature The High-Performance Digital Filter provides high accuracy/high speed weighing in environments with vibration problems. The AD-4410 greatly reduces the costs and maintenance required for anti-vibration equipment since it copes with vibrations without requiring many mechanical measures. What's more, conducting weighing while applying vibrations, once an extremely difficult task, is now possible. The High-Performance Digital Filter only requires one setting. For this reason, optimal settings for vibration cancelling can be found after just a few tries. Can be Calibrated in an Environment with Vibrations Until now, to conduct calibration, sources of vibration had to be completely stopped, or calibration had to be conducted on weekends or holidays when machines are not active. However, even in an environment with vibrations, the AD-4410 can be calibrated at any point, so costs incurred from stopping production or calibrating on weekends or holidays will disappear. Reliably accurate! Even with vibrations, weighing is easy! Fast response! Compressor

A Weighing Indicator that Can Be Used in an Environment with Vibrations Specifications Analog unit Input sensitivity Zero adjustment range Load cell excitation Temperature coefficients Nonlinearity Input noise Maximum measurement voltage Input impedance A/D conversion method Internal resolution Display resolution Sampling rate Calibration Digital unit Display elements Measurement data display Status display Over 0.15µV/d (d=minimum division) 35mV to +35mV ( 7mV/V to +7mV/V) DC5V±5%, 120mA Remote sensing function included Up to 8 load cells (350Ω) can be connected Zero; ±0.02µV/ C (Typ.) ±0.1µV/ C (Max.) Span; ±3ppm/ C (Typ.) ±15ppm/ C (Max.) 0.005% of F.S. Less than 0.3µVp-p 35mV to +35mV ( 7mV/V to +7mV/V) Over 10MΩ Delta-sigma modulation Approx. 16,000,000 999,999d (less than 20,000d recommended) 100 times/sec. Actual load calibration or digital span calibration not using actual load Weighing display: 7-segment 6-digit green LED Character height of 14.6mm Polarity display: 1 green LED Situational display: 6 red LEDs Display switchable between net and gross weight Display range: 0 to 999,999d (Select between 1, 2, 5, 10, and 50 for minimum division d ) Units: Affix a g, kg, or t unit sticker ZERO, STABLE, GROSS, NET, HOLD and a light which can be given a custom function by the user External output components Standard serial output (ch1) RS-232C 9-pin Dsub (male) Standard serial output (ch2) 20mA current loop signal (For connection with A&D peripherals) Control I/O 3-point input function selection (Non-voltage connection point or open collector) 3-point output function selection (open collector output) Modbus-RTU Supported with RS-232C (included as standard) or RS-232C/RS-485 (optional). Basic specifications Power source voltage Power consumption Operating temperature and humidity Dimensions Panel cut dimensions Dust/water protection Weight Options OP-03 OP-04 OP-11 AC100V to 240V 50/60Hz Approx. 10VA 10 C to 40 C/85%RH or less (Condensation must be avoided) 144(W) 72(H) 125(D) mm (Protrusions included, cable excluded) 138 68 mm The IP65 display when mounted into a panel (Using included rubber packing) Approx. 800g RS-485 (attached to ch2) DIN connector RS-232C (attached to ch2) DIN connector Stand Note: Only 1 OP-03 or OP-04 can be attached, when OP is attached 20mA current loop will become unusable. Standard accessories Instruction manual, 7-pin DIN connector, 8-pin DIN connector, load cell connector, power cable, rubber packing, capacity plate, unit stickers Note: Please prepare an RS-232C connector for standard serial output (ch1). A straight cable will be used when connecting to PC or PLC. External dimensions 144 Unit: mm Stand dimensions (181) Unit: mm AD-4410 WEIGHING INDICATOR 0 T ZERO TARE 72 ZERO STABLE GROSS NET HOLD Net/B/G NET GROSS I/ ON/OFF ESC F ENTER 123 (6) (118.5) Rear panel 137 138 +1 0 RS-232C C.L./OP CONTROL I/O 4-6 12 2-ø5 80 48 67 LOAD CELL 68 +0.7 0 Panel cutout dimensions A&D Company,Limited 50/60Hz 10VA 100-240V 70 116 152 Appearance and/or specifications subject to change for improvement without notice. AD4410-ADCC-02-ZW2-13502