Humidity transmitter for critical climate applications

Similar documents
The industrial humidity transmitter

The industrial humidity transmitter

testo Probe series testo 661x The industrial humidity transmitter We measure it. SPECIFICATIONS testo Probe series testo 661x

testo Probe series testo 661x The industrial humidity transmitter Committing to the future

Differential Pressure Monitoring in Cleanroom Technology

Measurement data monitoring system

Measurement data monitoring system

PTU300 Combined Pressure, Humidity and Temperature Transmitter

Measurement data monitoring system

testo 6651 Humidity transmitters testo 6600 Probes P2A software Parameterizing, adjusting and analyzing software Instruction manual Volume 1

Measurement data monitoring system

Measurement data monitoring system

HLX31 Series. Multifunctional Industrial Transmitter for Humidity / Temperature / Dew Point / Absolute Humidity... Model A. Model B.

testo 6651 Humidity transmitters testo 6600 Probes P2A software Parameterizing, adjusting and analyzing software Instruction manual

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

WiFi data logger system

DMT345 and DMT346 Dewpoint Transmitters

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

MMT330 Series Moisture and Temperature Transmitters for Oil

We measure it. Everything under control: With testo Saveris TM, measurement data are under control everywhere.

testo 6681 Humidity transmitters testo 6610 Probes P2A software Parameterizing, adjusting and analyzing software Instruction manual Volume 1

EE32/33 Series. Humidity / Temperature Transmitter for High Humidity and Chemical Applications. Typical Applications. Features

CAEL-DP Series Dew Point Transmitter for Industrial Control

EE75 Series. High-Precision Air / Gas Velocity Transmitter for Industrial Applications. Model A. Model B. Model C. Typical Applications.

WiFi data logger system

WiFi data logger system

testo 6681 Profibus Humidity transmitter with Profibus module testo 6610 Probes P2A software Parameterizing, adjusting and analyzing software

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

Measure, document, issue alarms. Automated with testo Saveris. Committing to the future

Differential pressure measuring instrument

Precision humidity/temperature control/sensing

Vaisala HUMICAP Structural Humidity Measurement Kit SHM40. Full SHM40 product presentation and introduction to the borehole method

testo 6740 Instruction manual

EE210. Humidity and Temperature Transmitter for Demanding Climate Control. Applications. Features. 36 v2.5 / Modification rights reserved EE210

Measurement data monitoring system testo Saveris.

Differential pressure measuring instrument

Measurement data monitoring system testo Saveris.

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

Next Generation! We measure it. With the professional Testo data loggers, a new age begins for you. Logger series testo 174. Logger series testo 175

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

Environmental Conditions C - remote sensing probe up to 120 C (248 F)

Next Generation! Committing to the future. With the professional Testo data loggers, a new age begins for you. Logger series testo 174

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

HLX75 Series. High-Precision Air / Gas Velocity Transmitter for Industrial Applications. Model A. Model B. Model C

Measurement data monitoring system testo Saveris.

InCos-P Pressure sensor 20 Pa Pa

All measurement data. Always available. On any device. The WiFi data logger system testo Saveris 2. Analysis & Reports. Graphical presentation

Digital Positioner 8049

InBin-P Pressure switches from 5 Pa Pa

EE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe

FILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Differential pressure measuring instrument

Product data sheet accessories control and regulation Accessories AIRWIN

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

EE35. Industrial Transmitter for Dew Point Measurement. Autocalibration. Installation. Alarm Output. Integrated power supply. Typical Applications

CDD4 Duct Carbon Dioxide Transmitter

We measure it. Automated and uninterrupted measurement data recording. Flexible system set-up with wireless or Ethernet probes in many probe versions

HYGROPHIL-F, Moisture Analyzer, Type , -11, -12, -13 series A

Thermal Mass Flowmeter Sensyflow FMT200-D

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Humidity goes Digital

Advantages high measuring dynamics Nv (up to 1 : 1000) measuring range from 0.2 m/s. low measuring uncertainty, even at lowest flow velocities

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

ProcessCalibrator Model CPH6000

EE211. Humidity and Temperature Transmitter for Continuous High Humidity. Features. 42 v1.3 / Modification rights reserved EE211 EE211

testostor 171 Instruction manual

Schneider Electric s SCD series of duct mount sensors measure the levels of CO 2. , RH (if equipped) and temperature of air inside a duct.

Sensor for car parks and tunnels

Next Generation! We measure it. With the professional Testo data loggers, a new age begins for you. Logger series testo 174. Logger series testo 175

EBI 25 Wireless Data Logger System

The SF-586b Insertion Flow Meter For Compressed Air, Gases And Exhaust Air (up to 400 C) In Pipe Diameters From 25mm to 5000mm

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410

Humidity goes Digital

Temperature and humidity regulator H3020 H3021 H3023 H3027. Instruction Manual

KISTOCK DATALOGGER KT 220 / KH 220 / KTT 220

Data logger / EASYBus

Precision digital measuring device PHYSICS 51

HygroClip DIGITAL Humidity and temperature probe

Differential pressure

CLEAN ROOM PANEL - CRP5

InReg Volume flow controller Pa

HMT330 Series Humidity and Temperature Transmitters for Demanding Humidity Measurement

HMT330 Series Humidity and Temperature Transmitters for demanding humidity measurement

Precision Hand-held Thermometer

RMS WIRELESS MINI LOGGER

HygroClip DI Digital Interface for HygroClip Probes v 1.0 Instruction Manual

-Camille Bauer Div. of Absolute Process Instruments, Inc. Phone: Fax: J-1

DP DP2500 DP0250

Differential pressure measuring instrument

PHYSICS Digital Measuring Devices

Multi Units Humidity/Temperature Transmitter. HygroViewer Model JW300 User Manual

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

Transcription:

Humidity transmitter for critical climate applications testo 6651 Optimum adjustment concept thanks to adjustability of the entire signal chain incl. analog adjustment Ethernet, relay and analog outputs allow optimum integration into individual automation systems Self-monitoring and early warning guarantee high system availability Calculation and presentation of the humidity parameters relative humidity absolute humidity and dewpoint. P2A software for parameterization, adjustment and analysis saves time and costs in commissioning and maintenance %RH C Display with multi-language display High-quality plastic housing Not all measurement problems can be solved with simple transmitters. The testo 6651 meets special challenges. When combined with the probe series testo 660x, the testo 6651 becomes the first choice in demanding air conditioning technology as well as in many other applications. www.testo.com

Technical data testo 6651 Parameters Humidity Units Meas. range Temperature Inputs and outputs Analog outputs Quantity Output type Measuring rate 1/s Resolution Accuracy of the analog outputs Max. load Further outputs Ethernet Relative humidity %RH, Ctd, Ftd, g/m³ 0 to 100 %RH Units Temperature in C / F Meas. range Dependent on probe (testo 660x) Galvanic isolation Relays 2 channels 0/4 to 20 ma (2-wire/4-wire) 0 to 1/5/10 V (4-wire) Galvanic isolation of the output signals (2-wire and 4-wire), isolation of supply from outputs (4-wire) 12 bit 0/4 to 20 ma / ±0.03 ma 0 to 1 V / ±1.5 mv 0 to 5 V / ±7.5 mv 0 to 10 V / ±15 mv 500 Ω at 24 VAC/DC Optional: module can be fitted as intermediary layer Optional: 4 relays (free allocation to measurement channels or as collective alarm with operating menu/p2a software), up to 250 V AC/DC / 3 A (NO/NC) General technical data Design Material Dimensions Weight Display Display Installation Cable screw fitting Other features Protection class EMC Plastic 122 x 162 x 77 mm (without probe) 0.675 kg (without probe, without Ethernet module) Optional: 2-line LCD with clear text line and relay status display Resolution 0.1 %RH / 0.01 C/ F / 0.1 C td / F td / 1 g/m 3 Operation Parameterization Four operating buttons for display / P2A software Probe connection Standard: PG screw fitting Optional: M16 or M20 M plug connection or optional: NPT 1/2 plug connection IP65 2004/108/EG Operating conditions Operating temperature (with integrated relay) Without display With display Digital plug connection -40 to +60 C Operating temperature -40 to +70 C / -40 to +158 F Storage temperature -40 to +80 C / -40 to +176 F Operating temperature 0 to +50 C / +32 to +122 F Storage temperature -40 to +80 C / -40 to +176 F Measurement medium Air, nitrogen Other outputs Mini DIN for Testo P2A parameterization software Power Voltage supply 2-wire: 24 VDC ±10 % 4-wire: 20 to 30 VAC/DC Current consumption max. 300 ma

Technical data probe series testo 660x testo 6601 testo 6602 testo 6603 testo 6604 testo 6605 Type Operating range Wall Duct Duct Cable Room climate probe wall mounting Climate probe duct mounting Process climate probe duct mounting for higher process temperatures Climate probe with cable Cable Stainless steel process probe with cable for higher process temperatures Measurement parameters Humidity Meas. range*** Measurement uncertainty* (+25 C)** 0 to 100 %RH ±(1.7 + 0.007 * mv) %RH (0 to 90 %RH) / ±(1.9 + 0.007 * mv) %RH (90 to 100 %RH) +0.02 %RH per Kelvin dependent on the process and electronics temperature (for a deviation of 25 C / 77 F) Selectable units %RH; Ctd/ Ftd Reproduceability better than ±0.2 %RH Sensor Testo capacitive humidity sensor, plug-in Testo capacitive humidity sensor, plug-in Testo capacitive humidity sensor, plug-in Testo capacitive humidity sensor, plug-in Testo capacitive humidity sensor; soldered Response time (without protective filter) t90 max. 10 sec. Temperature Selectable units C/ F Sensor -20 to +70 C/ -4 to +158 F -30... +120 C/ -22... +248 F -20... +70 C/ -4... +158 F -30... +120 C/ -22... +248 F Measurement uncertainty* (at +25 C / +77 F) ±0.15 C / 0.27 F (PT1000 Class A) Pt1000 Class AA General technical data Probe shaft Cable Plug Probe dimensions (diameter) Plastic ABS FEP coated Plastic ABS 12 mm Stainless steel Probe dimensions (probe shaft length) 70/200 mm 280 mm 140/280 mm 200/500 mm Cable length specially for duct versions 1 / 2 m 1 / 2 / 5 m Operating conditions Pressure tightness without 1 bar positive pressure (probe tip) PN 10 (probe tip) PN 1 (probe tip) * Other accuracies apply for wall probe length 70 mm combined with a current output (P07): Operation: 2 channels at 12 ma, without display illumination, relay off, additional measurement error to above values at +25 C (+77 F), humidity ± 2.5 % RH ***For continuous applications in high humidity (>80 %RH at 30 C for >12 h, >60 %RH at >30 C for >12h), please contact us via www.testo. com. **The determination of measurement uncertainty takes place according to GUM (Guide to the Expression of Uncertainty in Measurement): For the determination of measurement uncertainty, the accuracy of the measuring instrument (hysteresis, linearity, reproduceability), the uncertainty contribution of the test site as well as the uncertainty of the adjustment site (works calibration) are taken into account. For this purpose, the value of k=2 of the extension factor, which is usual in measurement technology is used as a basis, which corresponds to a trust level of 95%.

Technical drawings a b 122 77 162 Transmitter testo 6651 Transmitter testo 6651 Duct probe testo 6602/6603 Wall probe testo 6601 Transmitter testo 6651 Cable probe testo 6604/6605 L = Probe length L A = Probe length length protective cal A = 35 mm

Connection plan Connection plan 2-wire technology (4 to 20 ma) 18 24 VDC 0 V 2 channels 4 to 20 ma, max. load 500 Ω (at 24 V) Connection plan 4-wire technology (0 to 20 ma / 4 to 20 ma / 0 to 1 V / 0 to 5 V / 0 to 10 V) 24V CH1 CH2 CH3 + - + - + - + - 20 30 V AC/CD + - 0 V 2 channels 0 to 20 ma / 4 to 20 ma, max. load 500 Ω each, 0 to 1 V / 0 to 5 V / 0 to 10 V

Options / Ordering example The following options can be specified for the testo 6651: Bxx Analog output / supply Cxx Display / menu language Dxx Cable entry Exx Ethernet Fxx Humidity / temperature unit channel 1 Gxx Humidity / temperature unit channel 2 Hxx Relay Bxx Analog output/supply B01 4 to 20 ma (2-wire, 24 VDC), not possible with relay or Ethernet module B02 0 to 1 V (4-wire, 24 VAC/DC) B03 0 to 5 V (4-wire, 24 VAC/DC) B04 0 to 10 V (4-wire, 24 VAC/DC) B05 0 to 20 ma (4-wire, 24 VAC/DC) B06 0 to 20 ma (4-wire, 24 VAC/DC) Cxx Display / menu language C00 without display / without operating menu C02 with display and operating menu / English C03 with display and operating menu / German C04 with display and operating menu / French C05 with display and operating menu / Spanish C06 with display and operating menu / Italian C07 with display and operating menu / Japanese C08 with display and operating menu / Swedish C02 C08: Clear text language. Operating menu only available with display. Dxx Cable entry D01 Cable entry M16 (relay: M20) D02 Cable entry NPT ½ D03 Cable contact via M plug connection for signal and supply (for optionale relay: M20 cable entry) Exx Ethernet E00 Without Ethernet module E01 With Ethernet module Fxx Humidity/temperature unit Channel 1* F01 %RH / min / max F02 C / min / max F03 F / min / max F04 C td / min / max F05 F td / min / max F08 g/m 3 Gxx Humidity/temperature unit Channel 2* G01 %RH / min / max G02 C / min / max G03 F / min / max G04 C td / min / max G05 F td / min / max Hxx Relay H00 Without relay*** H01 4 relay outputs, limit value monitoring*** H02 4 relay outputs, limit values Channel 1 + collective alarm*** Ordering example Order code for transmitter testo 6651 with the following options: - 4 to 20 ma (2-wire) - Cable entry M16/M20 - Factory configuration channel 1: - %RH with scaling min 0 %, max 100 % - Factory configuration channel 2: - C with scaling min -10 C/-14 F, - max +70 C/+158 F* - without relay 0555 6651 A01 B01 C03 D01 E00 F01 0 100 G02-10 70 H00 * The standard scaling is supplied if min and max are not specified. ** Plug connection M12, 5-pin plug and socket available as accessories. *** not with code B01. Relay parameterization in commissioning via oparating menu (display) or P2A software

Options / Ordering example The following options can be specified for the probe testo 660x Lxx Probe version Mxx Protective cap Nxx Probe shaft length Pxx Probe length / length mm Lxx Probe version L01 Probe 6601 (Wall version) L02 Probe 6602 (Duct version -20 to 70 C) L03 Probe 6603 (Duct version -30 to 120 C) L04 Probe 6604 (Duct version -20 to 70 C) L05 Probe 6605 (Duct version -30 to 120 C) Ordering example Order code for testo 6602 with the following options: - Duct probe (-20 to +70 C/-4 to 158 F sufficient) - Sintered stainless steel probe - Probe length 280 mm 0555 6600 L02 M01 N23 P28 Mxx Protective cap M01 Stainless steel protective cap M02 Wire mesh protective filter M03 PTFE protective cap M04 Metal protective cap, open M05 ABS plastic protective cap, open Nxx Probe length / length mm N00 Without cable (for probe 6601) N01 Probe length 1 m (for probe 6604/6605) N02 Probe length 2 m (for probe 6604/6605) N05 Probe length 5 m (for probe 6605 only) N10 Probe length 10 m (for probe 6604/6605) N23 Probe length 0.6 m, especially for duct versions (for probes 6602/6603) Pxx Probe length / length mm P07 Probe length 70 mm (only for L01) P14 Probe length 140 mm (only for L04) P20 Probe length 200 mm (only for L01, L05) P28 Probe length 280 mm (only for L01, L05) P50 Probe length 500 mm (only L05)

Subject to change without notice. 0981 8234/msp/I/01.2015 www.testo.com