Operator Interface Terminal Manual Standard Two or Three Pump VFD Booster

Similar documents
pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02

The Experts in Vacuum Solutions

DEKKER KNOWLEDGE DATABASE KNOWLEDGE IS POWER

Dryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51

PLC 4 PRIMARY SEDIMENTATION SYSTEM SCADA SYSTEM OPERATION MANUAL. Revision 1.0 May 15, 2006

The Experts in Vacuum Solutions

ADDENDUM WCFX. Vision 2020i Touch Screen Controller. - a1 - Vision 2020i Controller

PROCESS CONTROL SYSTEMS LAP 4 Loop Controllers. Notes

Smith Meter ETR-1000 Electronic Register

Parallel SelfSensing Modulating Pump Controller

How To Manually Update QuickBooks Point of Sale 2013 In A Multi User Environment To The Most Current Release Via Intuit s Website


Pump Station Controller. Quick Start

WATLOW F4 KEYS. 1. If you ever reach a point on the controller where you do not want to be, press

Baltimore Aircoil Company

FlexPak 3000 Drive Operator Interface Module (OIM) User s Guide

VLT 2800 DRIVE SPECIFICATIONS

Taco System Logic (TSL)

iqpump1000 AC Drive Multiplex Quick Start Procedure

EZ Series In-Site CL control panel EZ Connect Mobile ios User Guide

CONFIGURING GRANDSTREAM IP PHONES AND GATEWAYS WITH THE 3CX PHONE SYSTEM

3000 CONTROLLER TRAINING MANUAL. April 26, 2012 Software Version

EPIC CONTROLLERS. 6 start times in each program (multiple intervals controlled by each start time)

PRODUCT PRESENTATION PROTECT C (1-3kVA) SEPTEMBER 2014 BU COMMERCIAL COMPACT-UPS, PM/SR

MANUAL FOR MODEL MP300 to MP700 ELECTRIC MOTOR DRIVEN FIRE PUMP CONTROLLERS

Installation & Calibration Manual

VILTech micro-controller. Operation and service manual

BIC 100 BERMAD Irrigation Control System

M&M Refrigeration, Inc. Computer Control System. Screw Compressor Control Sullair Retro Fit Panel


VARIOspeed Quick Start Manual

PLC Interface. Configuration and Operations Manual (Color OIT) Link Electric & Safety Control Company 444 McNally Drive Nashville, TN 37211

Service Bulletin SB685. Date: 8/18/2017 TriPac EVOLUTION Communications Update Bulletin Location: TSA Info Central\Service Bulletins

U90 Ladder Software Manual. Version 3.50, 6/03

Created by: Alarm System Store Quick Start Guide. for Interlogix NetworX NX4, NX6 & NX8

Bell & Gossett. Technologic 500 Pump Controller. Bulletin D-125. The Most Reliable and Affordable Solution for Variable Speed Pumping Systems.

Pump Controls for Water and Wastewater. PUMP Vision. UNIVERSAL PUMP CONTROLLER, RTU, and DATA LOGGER

Quantum HD Release Notes

PLC 5 BIOTOWERS SCADA SYSTEM OPERATION MANUAL. Revision 1.0 May 15, 2006

Learning how to use Lexis Red

METERING/DISPLAY MANUAL

Vacon HVAC100 Commissioning Guide

ViconNet Version 8 XX Installation and Upgrade Guide

HomeTroller Zee S2 Getting Started Guide

DV5-2. SC-DV5_Main.jpg. SC-DV5_Main.jpg. SC-DV5_Main.jpg

IpAlarm Module Set Up VirtuAlarm model

1TouchXL & 1TouchXLS

ikey Troubleshooting Tips

Touchpad User Guide (Model: C-LCD-122-TL)

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

Colour Graphic Terminal User Manual. Rev 3.1

Sygonix Home Starter Kit

GETTING STARTED WITH LONER BRIDGE & LONER 900

Mini Agg 1-10 (DC/AC)

M2500 Engine Controller Configuration Manual


STANDARD SUBMITTAL PACKAGE

Scoreboard Operator s Instructions MPC Control

IpAlarm Module Set Up

I.A.M. National Pension Fund Remittance Report Software

28-Sep-2017 Page 1 of 97

TEAM5 Operation Manual

Technologic 502 Variable Speed Pump Controller

DFS Series User s Manual (5N-1000N Capacity)

Chapter 3 Operating instructions

Scoreboard Operator s Instructions MPC Control

VARIABLE SPEED BOOSTER SYSTEMS AURORA INTELLIBOOST WITH INTELLIMANAGER. Distributed by Flow-Tech Industries

Touchpad User Guide. National Sales. Product Support. Freecall: Ph:

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703

DS-4483 Standard Logger Program Quick Reference For Software Version: 4.06

Advanced Test Equipment Rentals ATEC (2832)

Using the 20-HIM-A6 HIM with the LiquiFlo 2.0 AC Drive 20-HIM-A6 Firmware Revision Number or Later

TimerTools, v4.0 User s Manual. TimerTools 2006, 2011, 2017 Kagan Publishing

DIGITAL DECT PHONE INSTRUCTION MANUAL

INSTALLATION AND OPERATING INSTRUCTIONS DSST SYSTEM

7561-PSD Manual Portable Battery Powered Indicator

TR150 DRIVE STANDARD FEATURES

Operating Instructions

Scoreboard Operator s Instructions MPC Control

Pace Clock. For the System 6 Sports Timer Software User Guide. F873 rev

Keypad LCD (software version 3.10) CA-10 plus

NetMaster. Programming. Washer-Extractors Cabinet Hardmount Basic Programming Guide Refer to Page 7 for Model Numbers

# Trinity Lx Controller Replacement Instructions (Rev. 2)

PAGEPAC PLUS CONTROLLER CONFIGURATION PROGRAMMING GUIDE (V )

Trailer & Rail Refrigeration Units

Digitally Signing Tax Returns

Integriti User Manual. Elite / EliteX LCD Terminal Keypads

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000

PLC 24 FERRIC CHLORIDE AND POLYMER SYSTEM SCADA SYSTEM OPERATION MANUAL. Revision 1.0 May 3, 2006

E21 Operation Manual. (Version: V1.04)

BA688CF-F FOUNDATION fieldbus Panel mounting Display

IS2000. Administrative Operator s Guide

Installation & Calibration Manual

Centurion C5 M-VIEW Monochrome LCD (MV-5-C) Operations Manual Section 50

CENTURION Configurable Controller. Installation and Operations Manual Section 50

FTA1350 WYE-DELTA CLOSED FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

FTA750 LIMITED SERVICE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

ProTech-SX Simplex System. Product Manual 26546V2 (Revision A) Original Instructions , Volume 2 Programming and Configuration

VFD Instead of PLC? VFD s with Embedded Pump Functions Can Replace PLC s in Pumping Applications. yaskawa.com

Projector. Screen Computer Monitor. Document Camera. Smart Classroom Quick Start Guide. Psych/CompSci 156. Orientation

Transcription:

DOCUMENT: ECOIT2-1 EFFECTIVE: 02/14/07 SUPERSEDES: 02/26/03 Operator Interface Terminal Manual Standard Two or Three Pump VFD Booster The Operator Interface Terminal (OIT) allows the operator to monitor the status of the pump system as well as change system variables to improve or modify the performance of the pump system. All system variables can be changed while the system is operating, with proper password entry. This allows the operator to observe the effects of the changes immediately. The OIT consists of a LCD display with a sealed switch keypad. The keys are labeled by category. The operation of the OIT can be summarized into 2 modes of operation: I. Display Information II. Modify System Variables These two modes will be referred to as DISPLAY MODE and MODIFY MODE throughout this document. All of the OIT functions are grouped into 11 major categories, which are selected by using the appropriate key on the keypad. All of the yellow captioned buttons are password protected. Once the main category has been selected, the Page Up, Page Down, Clear, Enter and Toggle keys are used to navigate within the selected category and change variable values. Display Mode To display a particular message or variable, simply press one of the category keys (green, blue, red, or yellow keys) to select the desired category, then use the Page Up or Page Down keys to scroll through the messages within the category until the desired message is displayed. The Page Down key scrolls forward through the messages and the Page Up key scrolls backward. The category keys can be used at nearly any time to switch to a different category of messages. The lone exception is when a password-protected category has been selected and the password is being requested. In this instance, it is necessary to press the Clear button first before selecting a new category.

When an alarm occurs, an alarm message will be displayed on the OIT describing the alarm and displaying the two-character event code associated with it. This event code is shown in Event History to indicate what alarm has occurred. If multiple alarms occur, the messages will automatically scroll, with a new message being displayed every second. To stop the automatic scrolling, press the alarm silence/reset push button on the control panel door. This button serves as a toggle to disable or enable the scrolling function. Once the automatic scrolling has been stopped, the operator can manually review the status of each alarm or the sequence in which the alarms occurred. The procedure for doing this is described in the Alarms and Event History sections of this manual. To restart the automatic scrolling, press the alarm silence/reset push button a second time. Modify Mode To modify a system variable, follow these steps: 1) Display the variable to be modified using the method described above. 2) When changing to a password protected menu (yellow key), you will be prompted for a password. Once the last digit of the correct password is entered, the menu will be accessed. Press Clear if you do not wish to enter the password and select another category. 3) Page Up or Page Down to the applicable screen, then use the arrow keys to move the cursor to the set point to be changed. Press Clear and then type in the new value and press Enter to accept the change. The operator may also use the + and - keys to adjust set points. 4) The range through which each adjustable set point can be set is listed in Appendix 1 of the Operational Overview and Controls Guide. To ABORT a modification, press Clear and then the Enter key or press one of the category keys. Menu Buttons The OIT has 12 function keys, eleven of which can be used by the operator. When pressed, these keys will display different data values for viewing or changing. All of the yellow keys are password protected. Once a password-protected key is pressed, the password must be entered before the OIT will change to the appropriate menu. Note that if an attempt is made to switch to a given menu in error, the Clear key 2

must be pressed before another menu is selected or an error will occur. The various menus and their sub-elements are described as follows: 1. STATUS Pressing this key will display the main screen. This screen displays the flow rate, suction pressure (if equipped), system pressure, system pressure set point, VFD output speed, and the VFD mode of operation. The next screen shows the operator whether the following circuits are enabled or not: lead pump shut down, HydroCumulator charge (if applicable), limited auto-reset of low suction, and limited auto-reset of high system pressure alarms. The following screen allows the operator to test the alarm condition light and horn for five seconds using the Toggle key. 2. ALARMS This menu allows the operator to manually check the status of each alarm condition, using the Page Down and Page Up keys. 3. EVENT HISTORY This menu allows the operator to view the sequence in which alarms have occurred as well as the system operating conditions when each alarm occurred. The operator can use the + and - keys to scroll through the event records or use Clear and Enter to view specific records. It should be noted that the events are numbered in reverse chronological order so that the most recent event is record 0. The Help screen also describes how to search through the records. 4. SYSTEM PERFORMANCE This menu allows the operator to view the peak system flow rate, flow totals of the current day and the overall flow total, the number of pump starts, and the run hours for each pump. These can be reset under the RESTORE DEFAULTS AND SETUP key. 5. CLOCK SETTINGS (PASSWORD = 0001) Pressing this key will display the clock set points. Please note that changing the clock value will reset system performance data, except for AUTO pump run hours. To set the clock, make sure the cursor (an underline) is under the word VIEW. Then press Toggle to change it to SET. Next, use the arrow keys on the numeric keypad to move the cursor to the value to be changed and use the Clear and Enter or + and - keys to change the value. When done, cursor back to SET and change it back to VIEW. 3

6. PRESSURE SET POINTS (PASSWORD = 0001) Pressing this key will display the system pressure set point and the pressure sequencing deadband set point (the pressure drop below the system pressure set point to start the pumps). This is followed by the speed setting for starting the lag pump. The operator may effectively disable the speed consideration by setting a low start speed, in which case the lag pump will start on low pressure alone as normal. The next screen shows the low and high system pressure alarm deadband set points. If a suction pressure transmitter is supplied, the low suction pressure alarm set point and high suction pressure shut down set point will also be displayed. 7. FLOW SET POINTS (PASSWORD = 0001) Pressing this key will display the starting and stopping flow rates of the lag pump(s). The set points may be adjusted as previously described. 8. TIME SET POINTS (PASSWORD = 0001) The pump minimum run times, lag pump sequencing delays, lead pump shutdown delay, and alarm delays can be adjusted under this menu using the Clear, Enter, +, -, Page Down, and Page Up keys as previously described. 9. P.I.D. SET POINTS (PASSWORD = 0001) The following parameters can be changed here: 1) Sampling Time 2) Input Filter 3) Proportional Gain 4) Integral Time Constant 5) Derivative Gain 6) Derivative Time Constant 10. SPEED CONTROL (PASSWORD = 0001) This menu allows the operator to choose between automatic and manual modes of VFD speed control. The operator may adjust the minimum, maximum, manual, lag pump start, and lead pump stop speeds. The lag pump start speed augments pressure sequencing by requiring the VFD speed to be sufficiently high before the lag pump will start. This ensures that the running pump(s) are at near capacity to prevent unnecessary lag pump starts. Entering a low lag pump start speed can effectively disable this. 4

11. RESTORE DEFAULTS AND SETUP (PASSWORD = 1110) Pressing this key will display the restore defaults screen. The operator may restore either the factory defaults or the latest version of saved field defaults. To restore defaults simply press the Toggle key to display YES. The OIT will display DONE for several seconds when completed. CURRENT SETTINGS WILL BE LOST. MAKE NOTES BEFORE DOING. The next screens allow the operator to enable or disable the following circuits: lead pump shut down, HydroCumulator charge (if applicable), limited auto-reset of low suction, and limited auto-reset of high system pressure alarms. This is followed by screens allowing the operator to reset the peak flow rate, pump starts, pump run hours, today s total flow, and the overall total flow. 5