R Series for PXI Express Digital RIO with Kintex-7 325T FPGA. ni.com/manuals. This document explains how to install and configure the NI PXIe-7822R.

Similar documents
R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA. This document describes how to begin using the PCIe-7821R.

R Series Reconfigurable I/O Module (AI, AO, DIO) for PXI Express, 6 AI, 18 AO, 48 DIO, 1 MS/s AIO, 512 MB DRAM, Kintex-7 160T FPGA

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

NI PXIe-4138/4139. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Single-Channel System SMU

24-Channel, ±24 V Precision PXI Source Measure Unit

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

Electromagnetic Compatibility Guidelines

12-Channel, ±24 V Precision PXI Source Measure Unit

NI PXIe Contents GETTING STARTED GUIDE. RF Preselector Module

NI USRP-2900/2901. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Universal Software Radio Peripheral

NI PXI Contents GETTING STARTED GUIDE. 8 GHz RF Amplifier

NI PXIe-4080/4081/4082

To access NI 5622 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

NI PXIe-5160/5162. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10-Bit Oscilloscope

PXIe Contents GETTING STARTED GUIDE. 32-Channel Digital Pattern Instrument

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

PXIe Contents. Verifying the System Requirements GETTING STARTED GUIDE. 32-Channel Digital Pattern Instrument

GETTING STARTED GUIDE NI Channel Solid-State Relay (SSR) Digital Output Module

Electromagnetic Compatibility Guidelines

GETTING STARTED GUIDE NI AO, 0 ma to 20 ma, 16 Bit Simultaneous

GETTING STARTED GUIDE NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

NI PXI/PXIe/PCI Contents GETTING STARTED GUIDE. 14-Bit, 100 MS/s PXI Oscilloscope

GETTING STARTED GUIDE NI V, 32-Channel (Sinking Input), 7 µs C Series Digital Module

PXI/PCI Contents GETTING STARTED GUIDE. 2 GS/s Oscilloscope

NI PXIe-6544/6545/6547/6548

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals

Related Information Refer to the NI Switches Help for detailed information about features and programming options for your NI switch product.

NI sbrio Safety Guidelines GETTING STARTED GUIDE. Single-Board RIO OEM Devices. This document describes how to begin using the NI sbrio-9627.

Single-Channel Precision System Source Measure Unit (SMU)

NI USB Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10 MHz to 18 GHz RF Power Meter

To access NI 5105 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

NI PXI-5650/5651/5652

NI PXIe-6555/6556. Contents GETTING STARTED GUIDE. 200 MHz Digital Waveform Generator/Analyzer with PPMU

CALIBRATION PROCEDURE PXIe channel, 16-bit, 400 ks/s/ch, Ch-Ch Isolated Analog Input Module. ni.com/manuals

Reconfigurable Embedded Chassis with Integrated MXI-Express (x1) MXI-Express Switch

To access NI 5114 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

NI R Series. Contents. Software CALIBRATION PROCEDURE

Contents. Software. CALIBRATION PROCEDURE NI 9216/ Channel, 24-Bit, 100 Ω/1000 Ω RTD Analog Input Module

GETTING STARTED GUIDE NI S/s/channel, 4-Channel C Series Universal Analog Input Module

100 MHz, 250 MS/s, 14-Bit PXI Express Oscilloscope. This document explains how to install and start using the PXIe-5172.

GETTING STARTED GUIDE NI AI, 100 S/s/ch Simultaneous, Universal Measurements

NI PCIe-784xR, NI PXI-784xR, NI PXIe-784xR, NI USB-784xR, NI PCIe-785xR, NI PXI-785xR, NI PXIe-785xR, NI USB-785xR, and NI PXIe-786xR

Bracket and Mounting Dimensions

To access NI 5671 documentation, navigate to Start»All Programs»National Instruments» NI-RFSG»Documentation.

NI CVS Required Components. Optional Equipment GETTING STARTED GUIDE. Compact Vision System with USB3 Vision and Reconfigurable I/O

Foundation Fieldbus Hardware and NI-FBUS Software

CALIBRATION PROCEDURE NI PXIe Channel, Isolated Voltage/Current Analog Output Module

6 GHz Reconfigurable RF Vector Signal Transceiver with 1 GHz Bandwidth

Contents. Software. CALIBRATION PROCEDURE NI Channel, 300 Vrms, 24-Bit, Simultaneous, Channel-to-Channel Isolated Analog Input Module

CALIBRATION PROCEDURE CAL Contents. Software

CALIBRATION PROCEDURE NI channel, ±2- ma/±10 V, 24-bit Analog Input Module. ni.com/manuals

GETTING STARTED GUIDE

±10 V, 20 MS/s/ch, 14-Bit, 4-Channel C Series Digitizer Module

SH Cable Specifications

Electrical. SPECIFICATIONS SH Cable

NI Safety Guidelines. Safety Guidelines for Hazardous Locations GETTING STARTED GUIDE. Ethernet Expansion Chassis for C Series Modules

Contents. Software CALIBRATION PROCEDURE NI TC-4353

INSTALLATION GUIDE AND SPECIFICATIONS PXIe-4844

GETTING STARTED GUIDE NI Ch 24 V Sinking DI, 8-Ch 24 V Sourcing DO SIL3 Capable

NI crio-9101/9102/9103/9104

Contents. Software Requirements CALIBRATION PROCEDURE NI TB-4353

NI WSN-9791 Ethernet Gateway

6 GHz Reconfigurable RF Vector Signal Transceiver with 200 MHz Bandwidth

Contents. Software Requirements. CALIBRATION PROCEDURE NI PXIe-4357

Embedded Real-Time Controller with Reconfigurable FPGA for C Series Modules. This document describes how to begin using the NI crio-9064.

Contents. Software. CALIBRATION PROCEDURE NI Channel, ±5 V, 24-Bit Software-Selectable IEPE and AC/DC Analog Input Module

NI CMS Contents MAINTAINING HARDWARE. NI Condition Monitoring System for NI InsightCM Enterprise

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O

INSTALLATION INSTRUCTIONS SH160F-160M-NI SwitchBlock Cable

Getting Results with the NI PXI-6585R

USRP Contents. Verifying the System Requirements GETTING STARTED GUIDE. USRP Software Defined Radio Stand-Alone Device

Getting Started with R Series Multifunction RIO

NI ELVIS RIO Control Module

Thermal Kit for NI sbrio-9607/9627/9637

NOTE TO USERS NI 61xx Pinout Labels for the SCB-68 Multifunction I/O S Series Modules/Devices Using the 68-Pin Shielded Connector Block

NI CMS Contents MAINTAINING HARDWARE. NI Condition Monitoring System for NI InsightCM Enterprise

NI CMS-9068 and NI MMS-9068

Embedded CompactRIO Controller with Real-Time Processor and Reconfigurable FPGA

Getting Results with the NI 5752R

This document includes instructions for installing and configuring your PXIe-8861 PXI Express controller module.

Getting Started with R Series Intelligent DAQ

USER GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4340 and TB Ch, 24-bit, 25.6 ks/s Simultaneous AC LVDT Input Module

This document includes instructions for installing and configuring your PXIe-8821 PXI Express controller module.

Contents. CALIBRATION PROCEDURE NI PXIe-5624R 2 GS/s, 12-Bit IF Digitizer

10 MHz to 6 GHz, x86 Processor, GPS-Disciplined OCXO, USRP Software Defined Radio Stand-Alone Device

Figure 1. NI-7935R. Related Information For information about the device specifications, refer to the NI-7935R Specifications at ni.com/manuals.

Embedded CompactRIO Controller with Real-Time Processor and Reconfigurable FPGA

GETTING STARTED NI 9501 C Series Stepper Drive Modules and NI SoftMotion Module

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

You need the following to set up and use your terminal block:

NI FlexRIO FPGA Module Installation Guide and Specifications

This installation guide describes how to install and connect signals to the NI TBX-2808 screw terminal accessory for use with NI SwitchBlock cards.

NI PXI Contents GETTING STARTED GUIDE

NI PXIe Contents GETTING STARTED GUIDE. 6 GHz T/R Two-Port Vector Network Analyzer

Electromagnetic Compatibility Guidelines

Transcription:

GETTING STARTED GUIDE NI PXIe-7822R R Series for PXI Express Digital RIO with Kintex-7 325T FPGA Français Deutsch 日本語한국어简体中文 ni.com/manuals This document explains how to install and configure the NI PXIe-7822R. Safety Guidelines Caution Do not operate the NI PXIe-7822R in a manner not specified in this user manual. Product misuse can result in a hazard. You can compromise the safety protection built into the product if the product is damaged in any way. If the product is damaged, return it to National Instruments for repair. Electromagnetic Compatibility Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) as stated in the product specifications. These

requirements and limits are designed to provide reasonable protection against harmful interference when the product is operated in its intended operational electromagnetic environment. This product is intended for use in residential, commercial, and industrial locations. However, harmful interference may occur in some installations or when the product is connected to a peripheral device or a test object. To minimize interference with radio and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. Furthermore, any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules. Caution To ensure the specified EMC performance, operate this product only with shielded cables and accessories. Do not use unshielded cables or accessories unless they are installed in a shielded enclosure with properly designed and shielded input/ output ports and connected to the product using a shielded cable. If unshielded cables or accessories are not properly installed and shielded, the EMC specifications for the product are no longer guaranteed. Caution To ensure the specified EMC performance, install two (2) snap-on, ferrite beads (777297-01) per connected I/O cable in accordance with the product installation instructions. Caution To ensure the specified EMC performance, the length of any cable connected to the input port(s) must be no longer than 3 m (10 ft). Unpacking the Kit Caution To prevent electrostatic discharge (ESD) from damaging the device, ground yourself using a grounding strap or by holding a grounded object, such as your computer chassis. 1. Touch the antistatic package to a metal part of the computer chassis. 2. Remove the device from the package and inspect the device for loose components or any other sign of damage. Caution Never touch the exposed pins of connectors. Note Do not install a device if it appears damaged in any way. 3. Unpack any other items and documentation from the kit. Store the device in the antistatic package when the device is not in use. Verifying the Kit Contents Verify that the following components are in your kit. 2 ni.com NI PXIe-7822R Getting Started Guide

Figure 1. Kit Contents for the NI PXIe-7822R 1 2 3 1. Hardware 2. NI-RIO Media 3. Getting Started Guide Preparing the Environment Ensure that the environment in which you are using the NI PXIe-7822R meets the following specifications.... Operating temperature 0 C to 55 C (IEC 60068-2-1, IEC 60068-2-2)... Operating humidity 10% RH to 90% RH, noncondensing (IEC 60068-2-56) Pollution... degree 2... Maximum altitude 2,000 m Indoor use only. Note Refer to the device datasheet on ni.com/manuals for complete specifications. Installing Software on the Host Computer Before using the NI PXIe-7822R, you must install the following application software and device drivers on the host computer. 1. LabVIEW 2014 SP1 or later 2. LabVIEW Real-Time Module 2014 SP1 or later 1 3. LabVIEW FPGA Module 2014 SP1 or later 4. NI-RIO Device Drivers February 2015 or later 1 LabVIEW Real Time Module is only required if the R Series board is being used on a PXIe controller with a real-time operating system. NI PXIe-7822R Getting Started Guide National Instruments 3

Visit ni.com/info and enter the Info Code softwareversion for minimum software support information. Installing the NI PXIe-7822R Caution To prevent damage to the device caused by ESD or contamination, handle the device using the edges or the metal bracket. 1. Ensure the AC power source is connected to the chassis before installing the modules. The AC power cord grounds the chassis and protects it from electrical damage while you install the modules. 2. Power off the chassis. 3. Inspect the slot pins on the chassis backplane for any bends or damage prior to installation. Do not install a module if the backplane is damaged. 4. Remove the black plastic connectors from all the captive screws on the module front panel. 5. Identify a supported slot in the chassis. The following figure shows the symbols that indicate the slot types. Figure 2. Chassis Compatibility Symbols NI PXIe-1062Q 1 2 3 4 5 1. PXI Express System Controller Slot 2. PXI Peripheral Slot 3. PXI Express Hybrid Peripheral Slot 4. PXI Express System Timing Slot 5. PXI Express Peripheral Slot NI PXIe-7822R modules can be placed in PXI Express peripheral slots, PXI Express hybrid peripheral slots, or PXI Express system timing slots. 6. Touch any metal part of the chassis to discharge static electricity. 7. Ensure that the ejector handle is in the unlatched (downward) position. 8. Place the module edges into the module guides at the top and bottom of the chassis. Slide the device into the slot until it is fully inserted. 4 ni.com NI PXIe-7822R Getting Started Guide

Figure 3. Module Installation 1 2 3 1. Chassis 2. Hardware 3. Ejector Handle in Down (Unlatched) Position 9. Latch the module in place by pulling up on the ejector handle. 10. Secure the device front panel to the chassis using the front-panel mounting screws. Note Tightening the top and bottom mounting screws increases mechanical stability and also electrically connects the front panel to the chassis, which can improve the signal quality and electromagnetic performance. 11. Cover all empty slots using filler panels or slot blockers to maximize cooling air flow. 12. Power on the chassis. Verifying Hardware Installation for Host Targets You can verify that the system recognizes the NI PXIe-7822R by using Measurement & Automation Explorer (MAX). 1. Launch MAX by navigating to Start»All Programs»National Instruments»MAX or by clicking the MAX desktop icon. 2. Expand Devices and Interfaces. 3. Verify that the device appears under Devices and Interfaces. If the device does not appear, press <F5> to refresh the view in MAX. If the device does not appear after refreshing the view, visit ni.com/support for troubleshooting information. NI PXIe-7822R Getting Started Guide National Instruments 5

Verifying Hardware Installation for Remote Targets You can verify that the system recognizes the NI PXIe-7822R by using Measurement & Automation Explorer (MAX). 1. Launch MAX on the host computer. 2. Expand Remote Targets in the configuration tree and locate your system. 3. Install LabVIEW Real-Time Module 2014 SP1 and NI RIO Device Drivers February 2015 or later on your Remote Target. a) Refer to the Installing Software on the Host Computer section for information about installing software on the host. b) Refer to the PXI Express Controllers User Manual at ni.com/manuals for information on installing software on the target. 4. Under Remote Targets, find and expand Devices and Interfaces. If the device does not appear, press <F5> to refresh the view in MAX. If the device does not appear after refreshing the view, visit ni.com/support for troubleshooting information. Connecting the NI PXIe-7822R NI recommends using the following cables and accessories with the NI PXIe-7822R: EMI suppression ferrites (777297-01) Shielded 68-Pin Connector Block for R Series DIO & HSDIO Products (782914-01) Shielded R Series High Speed Digital Cable, 1m (156166-01) Shielded R Series High Speed Digital Cable, 2m (156166-02) Note NI is not liable for connections that exceed any of the maximum ratings of input or output signals on the NI PXIe-7822R and on the computer chassis. Refer to the NI PXIe-7822R Specifications, available at ni.com/manuals for the maximum input and output ratings for each signal. 6 ni.com NI PXIe-7822R Getting Started Guide

Table 1. NI PXIe-7822R Pinout Pinout Signal Description DIO <0...31> Digital I/O data through channels 0 through 31. External Clock x* DIO0 DIO2 68 34 67 33 66 32 65 31 64 30 63 29 62 28 DIO1 DIO3 Ground reference for signals. External Clock External clock input source that can be used for source synchronous acquisitions. The provided clock source must be stable and glitch-free. DIO4 61 27 DIO5 DIO6 60 26 59 25 58 24 DIO7 DIO8 57 23 DIO9 DIO10 56 22 55 21 54 20 DIO11 DIO12 53 19 52 18 DIO13 DIO14 51 17 DIO15 DIO16 50 16 49 15 DIO17 DIO18 48 14 47 13 DIO19 DIO20 DIO22 DIO24 DIO26 DIO28 46 12 45 11 44 10 43 9 42 8 41 7 40 6 39 5 38 4 37 3 36 2 DIO21 DIO23 DIO25 DIO27 DIO29 DIO30 35 1 DIO31 * x is the connector number. External Clock x is an input only. The NI PXIe-7822R is protected from overvoltage and overcurrent conditions. Refer to the NI PXIe-7822R Specifications, available at ni.com/manuals, for more information on overvoltage and overcurrent conditions. NI PXIe-7822R Getting Started Guide National Instruments 7

Digital I/O The NI PXIe-7822R provides connections for 128 digital input/output (DIO) channels. Connectors 0 through 3 each contain 32 high-speed DIO channels that can run up to 80 MHz signal frequencies. Each connector has selectable logic levels that you can configure as 1.2 V, 1.5 V, 1.8 V, 2.5 V, or 3.3 V. You can configure each channel as input or output. Figure 4. Connecting to the DIO Channels DIO0 1 Power DIO1 Connector X (DIO) DIO30 DIO31 FPGA 2 Connection Accessory NI PXIe-7822R 1. High-speed signal frequencies up to 80 MHz with logic levels configured as 1.2 V, 1.5 V, 1.8 V, 2.5 V, or 3.3 V 2. LED The DIO channels connect to the FPGA through protection circuitry, which has overvoltage and undervoltage protection as well as overcurrent protection. Refer to the NI PXIe-7822R Specifications for more information about the maximum voltage and current. When the system powers on, the DIO channels are set as input low with pull-down resistors. To set another power-on state, you can configure the NI PXIe-7822R to load a VI when the system powers on. The VI can then set the DIO lines to any power-on state. All the DIO channels on Connectors 0 through 3 are routed with a 50 Ω characteristic trace impedance. Route all external circuitry with a similar impedance to ensure best signal quality. NI recommends performing signal integrity measurements to test the affect of signal routing with the cable and connection accessory for your application. Installing Noise Suppression Ferrites Caution To ensure the specified EMC performance, operate this product only with shielded cables and accessories. Do not use unshielded cables or accessories unless they are installed in a shielded enclosure with properly designed and shielded input/ output ports and connected to the product using a shielded cable. If unshielded 8 ni.com NI PXIe-7822R Getting Started Guide

cables or accessories are not properly installed and shielded, the EMC specifications for the product are no longer guaranteed. Caution To ensure the specified EMC performance, install two (2) snap-on, ferrite beads (777297-01) per connected I/O cable in accordance with the product installation instructions. Caution To ensure the specified EMC performance, the length of any cable connected to the input port(s) must be no longer than 3 m (10 ft). For each connected I/O cable, install two (2) snap-on, ferrite beads (777297-01), one on each end of the cable, as close to the connector as practical. Two (2) snap-on, ferrite beads (777297-01) are included in ach of the following recommended cable kits: Shielded R Series High Speed Digital Cable, 1m (156166-01) Shielded R Series High Speed Digital Cable, 2m (156166-02) For user-supplied cables, the ferrite beads can be ordered directly from NI by visiting ni.com/ info and entering RDIO2FERRITE. Figure 5. Ferrite Installation 1 2 1. I/O cable 2. Ferrites NI PXIe-7822R Getting Started Guide National Instruments 9

Where to Go Next Refer to the following figure for information about other product tasks and associated resources for those tasks. HARDWARE SOFTWARE NI PXIe-7822R Specifications ni.com/manuals PXI Express Controller Documentation ni.com/manuals PXI Express Chassis Documentation ni.com/manuals Configuring a Project NI-RIO Help Learn LabVIEW Basics ni.com/gettingstarted NI R Series Examples NI Example Finder SUPPORT Software Support ni.com/info>swsupport Services ni.com/services Support ni.com/support NI Community ni.com/community Where to Go for Support The National Instruments website is your complete resource for technical support. At ni.com/ support you have access to everything from troubleshooting and application development selfhelp resources to email and phone assistance from NI Application Engineers. National Instruments corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. National Instruments also has offices located around the world to help address your support needs. For telephone support in the United States, create your service request at ni.com/support and follow the calling instructions or dial 512 795 8248. For telephone support outside the United States, visit the Worldwide Offices section of ni.com/ niglobal to access the branch office websites, which provide up-to-date contact information, support phone numbers, email addresses, and current events. 10 ni.com NI PXIe-7822R Getting Started Guide

Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. 2015 National Instruments. All rights reserved. 376822A-01 Feb15