Thermal Mass Flowmeter Sensyflow FMT200-D

Similar documents
Sensyflow FMT200-ECO2 Thermal Mass Flowmeter

Sensyflow FMT200-ECO2 Thermal Mass Flowmeter

Thermal Mass Flowmeter

Flow VA 500/

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service

EE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe

Flow. Order number VA 550. Order no. VA 570. Further accessories A_...M_

SensyMaster High quality and cost effective solution for precise and dynamic direct mass flow measurement for gases

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

C-Flow Coriolis Mass Flow Meter

Advantages high measuring dynamics Nv (up to 1 : 1000) measuring range from 0.2 m/s. low measuring uncertainty, even at lowest flow velocities

Digital Positioner 8049

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

TEPI11 P/I signal converter

Flow VA 550 / 570. compressed air and gases incl. temperature measurement. DVGW tested.

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

TRICOR Series TCM Coriolis Mass Flow Meters

SwirlMaster The new generation of swirl flowmeters

Electromagnetic Flowmeter ProcessMaster, HygienicMaster FEX300, FEX500

Temperature Measurement SITRANS TS300

Pressure transmitter/pressure switch PASCAL CS

Pressure transmitter/pressure switch PASCAL CS

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Clamping Device, Series 2709

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Pulverised Fuel Flowmeter

Temperature sensors and accessories for heat and cooling measurement points

Differential pressure sensor For ventilation and air-conditioning Model A2G-50

Humidity transmitter for critical climate applications

Immersion Temperature Sensors

Additional Information. Introduction. For gas, intelligent analog / HART PROFIBUS DPV1. Measurement made easy

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CoriolisMaster Accurate flow measurement of liquids and gases

EE75 Series. High-Precision Air / Gas Velocity Transmitter for Industrial Applications. Model A. Model B. Model C. Typical Applications.

EW773 Series Ultrasonic Hydronic Meters FOR HEATING AND COOLING APPLICATIONS

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Variable Area Flowmeter DATASHEET

Online data sheet DUSTHUNTER SB100 SCATTERED LIGHT DUST MEASURING DEVICES

P30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

Online data sheet DUSTHUNTER SB30 SCATTERED LIGHT DUST MEASURING DEVICES

LS 6600 Technical Datasheet

Temperature Transmitter head mounted TF02/TF02-Ex, field mounted TF202/TF202-Ex

Mass Flow Meter (MFM) for Gases

Threaded resistance thermometer Miniature design Model TR10-D

Flow sensors SFAB Key features

Thermal Mass Flowmeter Sensyflow FMT500-IG

Level switch NS 10/NS 25..-AM

FOR LIQUIDS AND SOLIDS

Digital Indicator DS 48/24 E

Electromagnetic Flowmeter FXT4000 (COPA-XT) HART-Protocol

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

PN DN FIG. 660D-BATT+670D-BATT 661D-BATT+670D-BATT SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE KAT KAT-06...

The SF-586b Insertion Flow Meter For Compressed Air, Gases And Exhaust Air (up to 400 C) In Pipe Diameters From 25mm to 5000mm

Threaded thermocouple Miniature design Model TC10-D

The industrial humidity transmitter

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

HYGROPHIL-F, Moisture Analyzer, Type , -11, -12, -13 series A

QUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.:

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Online data sheet. FW101 Ex SCATTERED LIGHT DUST MEASURING DEVICES

Flow Measurement SITRANS F M

Control IT Booster Pump Controller

HLX75 Series. High-Precision Air / Gas Velocity Transmitter for Industrial Applications. Model A. Model B. Model C

The industrial humidity transmitter

WaterMaster Select Electromagnetic flowmeter. The perfect fit for water industry applications

Temperature dry-well calibrator Models CTD9100-COOL, CTD , CTD , CTD

DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

CoriolisMaster mass flowmeter Automation solution for mixing applications

5/2 and 5/3 Directional-control valves, Series TC 15, G 1/4

Level Measurement Continuous level measurement - Ultrasonic transmitters

Static Heat Meter ULTRAHEAT XS 2WR6... UH f. Configuration and composition

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES

Temperature probes 468 Hans Turck GmbH & Co. KG Tel Fax Edition I/

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

selection of special materials is available to handle almost any fluid.

New! CleanStar SonicLine High Purity PFA Ultrasonic Flowmeters. Extended low flow measuring range ⅜" unit: l/min.

SONOMETER TM 500 Ultrasonic compact energy meter

Indicomp 4 Bargraph Indicator

Online data sheet. FLOWSIC100 Flare MASS FLOW MEASURING DEVICES

Compact pressure switch for multiple actuators

Ultrasonic Flow Meter Brochure

Air data test indicator Model CPA2501

M3P..G/A, M3P..F/A Modulating control valves (PN16) for chilled and hot water systems

Solenoid Valves PN16 for gas flow interception

High-end pressure controller Model CPC8000

Instruction Manual Cooling Jacket Advanced. Cooling Jacket Advanced Cooling Jacket Advanced Extended

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Float switch For industrial applications Model RLS-1000

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

Precision digital gas density indicator Model GDI-100-D

Precision digital pressure gauge Model CPG1500

Level Measurement Continuous level measurement - Ultrasonic transmitters

Transcription:

Data Sheet Thermal Mass Flowmeter Sensyflow FMT200-D Direct measurement of mass flow or standard volume flow of compressed air, nitrogen and biogas independent of media pressure and temperature Wide measuring range of 1:100 Precise measurement even with low flows Measured value display starting at 0 Nm 3 /h High measuring accuracy Quick response time < 0.5 s Negligible pressure loss No moving parts no wear, maintenance-free Defined, reproducible mounting position User-friendly installation via screwed or flanged pipe components Weld-on adapters for larger meter sizes Compact device with signal output at the sensor head Applications Measurement of compressed air consumption Leakage detection Optimization of compressed air systems Measurement of the amount of biogas created Efficiency factor determination and balancing in biogas plants Direct mass flow measurement Easy installation Compact design

Operating principle and system design Sensyflow FMT200-D is a compact system for mass flow or standard volume flow measurement of compressed air, nitrogen and biogas. Sensyflow FMT200-D operates according to the principle of a hot-film anemometer. This measuring method determines the gas mass flow directly, without further need for pressure and temperature compensation. Additional measuring points for pressure and temperature nor a compensation computer are required. Sensyflow FMT200-D is installed in the appropriate pipe component in a well-defined and non-rotatable position as a part of the measuring line. Pipe components made of galvanized steel are available with external thread fittings in imperial sizes. Pipe components with flange connections as well as the weld-on adapter for meters sizes DN 100... DN 250 (4... 10") are manufactured from stainless steel. The transducer accommodates the sensor unit and the evaluation electronics. Sensyflow FMT200-D supplies an output signal linear to the flow. The system is calibrated and immediately ready for use. Output parameters can be set via LKS (local communication interface) adapter (option). A standard power supply unit can be used for powering Sensyflow FMT200-D. Calibration applications The calibration of the devices is done on a highly precise flow test machine with air as calibration medium. For standard biogas applications, the calibration data are subsequently converted, based on a medium gas composition of 53 Vol% methane, 45 Vol% carbon dioxide and 2 Vol% air. Devices for applications that clearly deviate from this gas composition must be ordered with a special calibration for biogas. In this case, the exact gas composition must be specified with the order. Technical data Measuring ranges Nominal size Maximal upper range value for air/nitrogen (inch) kg/h Nm 3 /h 1) Nl/min 2) lb/h SCFM 1 1 1/2 2 3 6 165 430 740 1775 7500 125 330 570 1375 5800 2100 5500 9500 22800 97000 360 940 1600 3900 16500 70 190 330 800 3400 Nominal size Maximal upper range value for standard biogas (inch) kg/h Nm 3 /h 1) Nl/min 2) lb/h SCFM 1 1 1/2 2 3 6 130 310 510 1200 5700 95 260 390 920 4400 1600 4300 6500 15000 73000 280 680 1120 2640 12500 55 150 230 540 2500 1) Notation also m³/h - qn 2) Notation also l/min - qn All volume flow rate specifications are referenced to 0 C/ 1013.25 hpa (32 F/14.696 psi). Output Analog output signal 0/4 20 ma, switchable Load < 750 Ω, electrically isolated Characteristics Measured error Air, nitrogen <1.5 % of rate + 0.05 % of end value Biogas <1.8% of rate + 0.1% of end value under calibration conditions in specified flow range Repeatability < ± 0.25 % of measured value, t meas = 10 s Response time T 63 500 ms Influences Temperature effect < 0.05 %/K of measured value Pressure effect 0.2 %/100 kpa (bar [14.5 psi]) of measured value Pressure drop <1 kpa (10 mbar [0.145 psi]) at full scale decreasing quadratically for smaller flow rates 2

Ambient conditions Ambient temperature for transducer -25 +70 C Degree of protection IP 65 Storage temperature -25... 85 C (-13... 185 F) Measured medium conditions Operating temperature -25 150 C (-13... 302 F) Maximum operating pressure Standard 1 MPa (10 bar [145 psi]) Construction Weight in kg (lbs) Threaded pipe component Flange pipe component Meter size kg (lbs) kg (lbs) 1 1.5 3.3 5.6 12.3 1 1/2 3.0 6.6 8.4 18.5 2 5.5 12.1 11.0 24.3 3 9.5 20.9 19.0 41.9 Weld-on adapter incl. lock nut kg (lbs) 0.5 1.1 Flowmeter primary kg (lbs) 1.8 4.0 Materials, process connection Flowmeter primary Stainless steel, e.g. 1.4301 Pipe component with external threads R 1"...3" Galvanized steel Pipe component with connection flanges DN 25... DN 80 Stainless steel, e.g. 1.4301 Weld-on adapter Stainless steel, e.g. 1.4301 Connection flange according to EN1092-1 Form B1, PN10 Power supply Voltage 24 V AC/DC ± 25 % Power consumption < 15 W Current consumption < 600 ma, slow-blow fuse of at least 2 A recommended, cable gland M20 x 1.5 Communication interface LKS (Local communication interface) adapter Accessories (optional) Power supply unit Display unit Totalizer with display (current-to-pulse converter) Configuration The analog output of the Sensyflow FMT200-D can be switched between 0 20 ma and 4 20 ma. Additionally, there is the opportunity to define a measurement window in a way that a flow rate smaller than the calibrated one causes an output signal of 20 ma. The signal for error indication can be set to < 3.5 ma and > 22 ma. The device can be configured via the LKS (local communication interface) adapter by using a PC or laptop. You can select the output signal to be used and define the measuring range. 3

Dimensional drawings dimensions in mm (inch) Pipe component Transducer Flange DN on both sides 125 (4,92 ) F 27 (1,06 ) 58 (2,28 ) 120 (4,72 ) 50 (1,97 ) External thread R D Direction of flow L1 A Z-18948 Rd 52 x 1/6" Direction of flow 120 (4,72 ) Centre of pipe component 197 (7,76 ) Z-189371 Nominal size A L1 Ø D interior Thread R Flange F 1 550 (21,65 ) 410 (16,14 ) 27,3 (1,07 ) R1 : 33,7 1,2 DN 25: 115 (4,53 ) 1½ 820 (32,28 ) 615 (24,21 ) 41,9 (1,65 ) R1½ : 48,3 3,2 DN 40: 150 (5,91 ) 2 1080 (42,52 ) 810 (31,89 ) 53,9 (2,12 ) R2 : 60,3 3,2 DN 50: 165 (6,50 ) 3 1600 (62,99 ) 1200 (47,24 ) 79,9 (3,15 ) R3 : 88,9 4,5 DN 80: 200 (7,87 ) Dimensions in mm (inch) 4

Weld-on adapter for Sensyflow FMT200-D-transducers Rd52 x 1/6 Centering pin Length L of the weld-on adapter in state of delivery is L = 117 mm (4,6 ) a) For outside pipe diameters from 100... 150 mm (4 6"): The weld-on adapter must be shortened to length L before mounting, according to L = H1 - ½ Ø D outside with H1 = 120 mm (4,72 ). H1 L b) For outside pipe diameters from 150... 250 mm (6... 10 ): The weld-on adapter must be shortened to a fixed length L = 45 mm (1,77 ) before mounting. A measuring position out of the pipe centre will thus be achieved. For an accurate calibration, information about the exact inner pipe diameter and wall thickness in mm must be provided together with the purchase order. Ø 34 (1,34 ) D Direction of flow Note for all meter sizes: The weld-on adapter must be welded to the pipe always together with the cap-nut. It is not possible to mount the cap-nut after the welding process. Observe the pipeline wall thickness and amount of shrinkage when welding. The distance H1 from the top edge of the adapter to the pipe center line must be within a tolerance of ± 2 mm (for outside pipe diameters from 100... 150 mm (4 6")). Rectangularity to the pipe axis must be absolutely kept (max. tolerance: 2 ). The centering pin of the adapter must be aligned in flow direction to the pipe axis exactly (at outlet run length, behind measuring point). After welding the free passage for inserting the transducer must be at least 28 mm (if required, use drill to clear). Recommended steadying length for Sensyflow FMT200-D acc. to DIN EN ISO 5167-1 X D 15 D 5 D Z-189501 < 7 Z-189391 Expansion X = 0 Z-189421 Two 90 elbows in one level X = 10 < 7 Z-189401 Reduction X = 0 Z-189431 Two 90 elbows in two levels X = 25 90 elbow Valve / slide Z-189411 X = 5 Z-189441 X = 35 5

Ordering information Thermal Mass Flowmeter Variant digit No. 1-7 8 9 10 Code FMT200-D Catalog No. V14223- Transducer Calibration Type Standard calibration for air and nitrogen 1 Operating pressure 1... 10 bar abs., operating temperature 0... 60 C Upper range value see Data Sheet Details according to Code Nos. 514-519 (see additional ordering information) 1) Special calibration for air and nitrogen 2 according to Code-Nos. 512-519 (see additional ordering information) Standard calibration for biogas 3 Operating pressure 1... 10 bar abs., operating temperature 0... 60 C Upper range value see Data Sheet Details according to Code Nos. 514-519 (see additional ordering information) 1) Special calibration for biogas 4 according to Code-Nos. 511-519 (see additional ordering information) Analog Output 4... 20 ma (alarm < 3.5 ma) 1 4... 20 ma (alarm > 22 ma) 2 0... 20 ma 3 Pipe Component 1" threaded 1 1 1/2" threaded 2 2" threaded 3 3" threaded 4 DN 25 flanges DIN PN 10, nominal pressure 10 bar (1 MPa [145 psi]) A DN 40 flanges DIN PN 10, nominal pressure 10 bar (1 MPa [145 psi]) B DN 50 flanges DIN PN 10, nominal pressure 10 bar (1 MPa [145 psi]) C DN 80 flanges DIN PN 10, nominal pressure 10 bar (1 MPa [145 psi]) D weld-on adapter DIN 11851 incl. Cap-nut, DN 100 / 4 in. to DN 250 / 10 in. N Additional ordering information value unit Flow unit (clear text) 1) Standard conditions (clear text) C, mbar abs. 2) Operating temperature (clear text) C Operating pressure (clear text) mbar abs. Calibrated measuring range (clear text) (clear text) 3) Nominal size, pipe inner diameter (clear text) mm 4) Upper measuring range value adjusted to (clear text) (clear text) 1) Biogas composition for special calibration Vol % Material certificate acc. to EN 10204 3.1 for transducer and pipe component 30A Certificate GOST Russland metrological approval GOST Kazakhstan metrological approval CG1 CG2 1) Possible units are: kg/h ; kg/min ; kg/s ; m3 /h -qn ; m3 /min -qn ; m3 /s -qn ; l/h -qn ; l/min -qn ; l/s -qn ; SCFM 2) Standard state for volume flow units: Please specify the conditions, e.g. 0 C, 1013 mbar (standard) 3) Please specify in case of special calibration or when weld-on adapter is used 4) To be specified when weld-on adapter is used 6

Accessories FMT200-D Catalog No. Code LKS Adapter 7962828 Local Communication Interface for parameterization incl. Communication software Power supply unit 7962800 Housing for rail mounting 62.5 mm x 75 mm x 139 mm Input 230 V AC Output 24 V DC / 2.5 A Digital LED display see Data Sheet 10/33-2.16 EN V33264A- Flow Totalizer FCU200-T (SensyCal T) see Data Sheet 10/18-5.22 EN V18022-5... 7

ABB has Sales & Customer Support expertise in over 100 countries worldwide. www.abb.com/flow The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in the Fed. Rep. of Germany (12.2008) ABB 2008 3KXF421005R1001 Rev. C ABB Ltd. Oldends Lane, Stonehouse Gloucestershire, GL10 3TA UK Tel: +44(0)1453 826661 Fax: +44(0)1453 829671 ABB Inc. 125 E. County Line Road Warminster, PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 ABB Inc. 3450 Harvester Road Burlington Ontario L7N 3W5 Canada Tel: +1 905 681 0565 Fax: +1 905 681 2810 ABB Automation Products GmbH Borsigstr. 2 63755 Alzenau Germany Tel: +49 551 905-534 Fax: +49 551 905-555 CCC-support.deapr@de.abb.com