NI PXIe-4080/4081/4082

Similar documents
NI PXIe-4138/4139. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Single-Channel System SMU

NI PXIe-5160/5162. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10-Bit Oscilloscope

24-Channel, ±24 V Precision PXI Source Measure Unit

12-Channel, ±24 V Precision PXI Source Measure Unit

To access NI 5622 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

NI PXIe Contents GETTING STARTED GUIDE. RF Preselector Module

To access NI 5105 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

NI PXI/PXIe/PCI Contents GETTING STARTED GUIDE. 14-Bit, 100 MS/s PXI Oscilloscope

R Series Reconfigurable I/O Module (AI, AO, DIO) for PXI Express, 6 AI, 18 AO, 48 DIO, 1 MS/s AIO, 512 MB DRAM, Kintex-7 160T FPGA

R Series for PXI Express Digital RIO with Kintex-7 325T FPGA. ni.com/manuals. This document explains how to install and configure the NI PXIe-7822R.

PXI/PCI Contents GETTING STARTED GUIDE. 2 GS/s Oscilloscope

NI PXI Contents GETTING STARTED GUIDE. 8 GHz RF Amplifier

To access NI 5114 documentation, navigate to Start»All Programs»National Instruments» NI-SCOPE»Documentation.

R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA. This document describes how to begin using the PCIe-7821R.

NI USRP-2900/2901. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Universal Software Radio Peripheral

Electromagnetic Compatibility Guidelines

Related Information Refer to the NI Switches Help for detailed information about features and programming options for your NI switch product.

PXIe Contents GETTING STARTED GUIDE. 32-Channel Digital Pattern Instrument

NI USB Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10 MHz to 18 GHz RF Power Meter

NI PXI-5650/5651/5652

NI PXIe-6544/6545/6547/6548

Single-Channel Precision System Source Measure Unit (SMU)

PXIe Contents. Verifying the System Requirements GETTING STARTED GUIDE. 32-Channel Digital Pattern Instrument

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

NI PXIe-6555/6556. Contents GETTING STARTED GUIDE. 200 MHz Digital Waveform Generator/Analyzer with PPMU

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

To access NI 5671 documentation, navigate to Start»All Programs»National Instruments» NI-RFSG»Documentation.

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

GETTING STARTED GUIDE NI Channel Solid-State Relay (SSR) Digital Output Module

GETTING STARTED GUIDE NI V, 32-Channel (Sinking Input), 7 µs C Series Digital Module

6 GHz Reconfigurable RF Vector Signal Transceiver with 1 GHz Bandwidth

GETTING STARTED GUIDE NI AO, 0 ma to 20 ma, 16 Bit Simultaneous

Reconfigurable Embedded Chassis with Integrated MXI-Express (x1) MXI-Express Switch

CALIBRATION PROCEDURE PXIe channel, 16-bit, 400 ks/s/ch, Ch-Ch Isolated Analog Input Module. ni.com/manuals

NI PXIe Contents GETTING STARTED GUIDE. 6 GHz T/R Two-Port Vector Network Analyzer

GETTING STARTED GUIDE NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

100 MHz, 250 MS/s, 14-Bit PXI Express Oscilloscope. This document explains how to install and start using the PXIe-5172.

±10 V, 20 MS/s/ch, 14-Bit, 4-Channel C Series Digitizer Module

Electromagnetic Compatibility Guidelines

NI R Series. Contents. Software CALIBRATION PROCEDURE

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

Contents. Software. CALIBRATION PROCEDURE NI Channel, 300 Vrms, 24-Bit, Simultaneous, Channel-to-Channel Isolated Analog Input Module

NI PCIe-784xR, NI PXI-784xR, NI PXIe-784xR, NI USB-784xR, NI PCIe-785xR, NI PXI-785xR, NI PXIe-785xR, NI USB-785xR, and NI PXIe-786xR

6 GHz Reconfigurable RF Vector Signal Transceiver with 200 MHz Bandwidth

Contents. Software. CALIBRATION PROCEDURE NI 9216/ Channel, 24-Bit, 100 Ω/1000 Ω RTD Analog Input Module

NI CVS Required Components. Optional Equipment GETTING STARTED GUIDE. Compact Vision System with USB3 Vision and Reconfigurable I/O

Contents. Software. CALIBRATION PROCEDURE NI Channel, ±5 V, 24-Bit Software-Selectable IEPE and AC/DC Analog Input Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

CALIBRATION PROCEDURE CAL Contents. Software

Bracket and Mounting Dimensions

GETTING STARTED GUIDE NI AI, 100 S/s/ch Simultaneous, Universal Measurements

NI sbrio Safety Guidelines GETTING STARTED GUIDE. Single-Board RIO OEM Devices. This document describes how to begin using the NI sbrio-9627.

CALIBRATION PROCEDURE NI channel, ±2- ma/±10 V, 24-bit Analog Input Module. ni.com/manuals

INSTALLATION GUIDE AND SPECIFICATIONS PXIe-4844

USER GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4340 and TB Ch, 24-bit, 25.6 ks/s Simultaneous AC LVDT Input Module

CALIBRATION PROCEDURE NI PXIe Channel, Isolated Voltage/Current Analog Output Module

Electromagnetic Compatibility Guidelines

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

Electrical. SPECIFICATIONS SH Cable

NI Safety Guidelines. Safety Guidelines for Hazardous Locations GETTING STARTED GUIDE. Ethernet Expansion Chassis for C Series Modules

This document includes instructions for installing and configuring your PXIe-8821 PXI Express controller module.

Foundation Fieldbus Hardware and NI-FBUS Software

Figure 1. NI-7935R. Related Information For information about the device specifications, refer to the NI-7935R Specifications at ni.com/manuals.

GETTING STARTED GUIDE NI S/s/channel, 4-Channel C Series Universal Analog Input Module

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

USRP Contents. Verifying the System Requirements GETTING STARTED GUIDE. USRP Software Defined Radio Stand-Alone Device

NI crio-9101/9102/9103/9104

GETTING STARTED GUIDE NI Ch 24 V Sinking DI, 8-Ch 24 V Sourcing DO SIL3 Capable

Contents. CALIBRATION PROCEDURE NI PXIe-5624R 2 GS/s, 12-Bit IF Digitizer

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4322 and TB Channel, Isolated Voltage/Current Analog Output Module

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4357 and TB-4357

SH Cable Specifications

Embedded Real-Time Controller with Reconfigurable FPGA for C Series Modules. This document describes how to begin using the NI crio-9064.

NI PXI Contents GETTING STARTED GUIDE

Electromagnetic Compatibility Guidelines

NI 6521 Specifications

NI Digital Multimeters

This document includes instructions for installing and configuring your PXIe-8861 PXI Express controller module.

NI ELVIS RIO Control Module

Contents. Software Requirements. CALIBRATION PROCEDURE NI PXIe-4357

SCXI -1104/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

GETTING STARTED NI 9501 C Series Stepper Drive Modules and NI SoftMotion Module

10 MHz to 6 GHz, x86 Processor, GPS-Disciplined OCXO, USRP Software Defined Radio Stand-Alone Device

Contents. Software CALIBRATION PROCEDURE NI TC-4353

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4339 and TB-4339/B/C 8 Ch, 24-bit, 25.6 ks/s Universal Bridge Input Module

SCXI -1102/B/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

NI CMS-9068 and NI MMS-9068

SPECIFICATIONS AND FEATURES GUIDE NI Serial Legacy Hardware

Contents. Software Requirements CALIBRATION PROCEDURE NI TB-4353

Electromagnetic Compatibility Guidelines

NI WSN-9791 Ethernet Gateway

NI CMS Contents MAINTAINING HARDWARE. NI Condition Monitoring System for NI InsightCM Enterprise

NI SMD-7610 Stepper Drives and NI 9512 C Series Modules

You need the following to set up and use your terminal block:

Getting Results with the NI 5752R

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals

Getting Results with the NI PXI-6585R

GETTING STARTED GUIDE

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O

Transcription:

GETTING STARTED GUIDE NI PXIe-4080/4081/4082 1.8 MS/s Digital Multimeter Note Before you begin, install and configure your chassis and controller. This document explains how to install, configure, and test the NI 4080/4081/4082. The NI 4080/4081/4082 is a digital multimeter that ships with NI-DMM, which you use to program the device. To access NI 4080/4081/4082 documentation, navigate to Start»All Programs»National Instruments»NI-DMM Documentation. Contents Caution The protection provided by this device may be impaired if the device is used in a manner not specified in this document. Electromagnetic Compatibility Guidelines...2 Verifying the System Requirements...2 Unpacking the Kit... 2 Preparing the Environment... 3 Safety... 3 Kit Contents... 4 Other Equipment... 4 Installing the Software... 4 Installing the NI 4080/4081/4082... 5 Hardware Front Panel Connectors... 6 Connecting Signals... 7 Requirements for Cables and Probes... 10 Configuring the NI 4080/4081/4082 in...11 Programming the NI 4080/4081/4082...11 NI-DMM Examples... 13 Troubleshooting... 14 What Should I Do if the NI 4080/4081/4082 Doesn't Appear in?...14 What Should I Do if the Module Fails the Self-Test?...15 Where to Go Next... 15 Worldwide Support and Services... 15

Electromagnetic Compatibility Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment. This product is intended for use in industrial locations. However, harmful interference may occur in some installations, when the product is connected to a peripheral device or test object, or if the product is used in residential or commercial areas. To minimize interference with radio and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. Furthermore, any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules. Verifying the System Requirements To use the NI 4080/4081/4082, your system must meet certain requirements. For more information about minimum system requirements, recommended system, and supported application development environments (ADEs), refer to the readme, which is available on the software media or online at ni.com/updates. Unpacking the Kit Caution To prevent electrostatic discharge (ESD) from damaging the device, ground yourself using a grounding strap or by holding a grounded object, such as your computer chassis. 1. Touch the antistatic package to a metal part of the computer chassis. 2. Remove the device from the package and inspect the device for loose components or any other sign of damage. Caution Never touch the exposed pins of connectors. Note Do not install a device if it appears damaged in any way. 3. Unpack any other items and documentation from the kit. Store the device in the antistatic package when the device is not in use. 2 ni.com NI PXIe-4080/4081/4082 Getting Started Guide

Preparing the Environment Ensure that the environment you are using the NI 4080/4081/4082 in meets the following specifications. Operating Environment Ambient temperature range Relative humidity range Storage ambient temperature range Maximum altitude Pollution Degree 2 Indoor use only. 0 C to 55 C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2. Meets MIL-PRF-28800F Class 3 low temperature limit and MIL-PRF-28800F Class 2 high temperature limit.) 10% to 90%, noncondensing (Tested in accordance with IEC 60068-2-56.) -40 C to 70 C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2.) 2,000 m (800 mbar) (at 25 C ambient temperature) Note Refer to the device specifications on ni.com/manuals for complete specifications. Safety Caution Always refer to the specifications document for your device before connecting signals. Failure to observe the specified maximum signal ratings can cause shock, a fire hazard, or damage to the devices connected to the NI 4080/4081/4082. NI is not liable for any damage or injuries resulting from incorrect signal connections. NI PXIe-4080/4081/4082 Getting Started Guide National Instruments 3

PXIe-4080 61/2 Digit DMM Kit Contents Figure 1. NI 4080/4081/4082 Kit Contents 1 2 3 4 5 1. NI PXIe-4080/4081/4082 Device 2. Test probes 3. Driver Software DVD 4. NI PXIe-4080/4081/4082 Getting Started Guide (this document) 5. Maintain Forced-Air Cooling Note to Users Other Equipment There are several required items not included in your device kit that you need to install or operate the NI 4080/4081/4082. 1/8 in. flathead screwdriver A PXI Express chassis with a controller and the chassis documentation Installing the Software You must be an Administrator to install NI software on your computer. 1. Install an ADE, such as LabVIEW or LabWindows /CVI. 2. Insert the driver software media into your computer. The installer should open automatically. If the installation window does not appear, navigate to the drive, double-click it, and double-click autorun.exe. 3. Follow the instructions in the installation prompts. Note Windows users may see access and security messages during installation. Accept the prompts to complete the installation. 4 ni.com NI PXIe-4080/4081/4082 Getting Started Guide

4. When the installer completes, select Restart in the dialog box that prompts you to restart, shut down, or restart later. Installing the NI 4080/4081/4082 Caution To prevent damage to the NI 4080/4081/4082 caused by ESD or contamination, handle the module using the edges or the metal bracket. 1. Ensure the AC power source is connected to the chassis before installing the module. The AC power cord grounds the chassis and protects it from electrical damage while you install the module. 2. Power off the chassis. 3. Inspect the slot pins on the chassis backplane for any bends or damage prior to installation. Do not install a module if the backplane is damaged. 4. Remove the black plastic covers from all the captive screws on the module front panel. 5. Identify a supported slot in the chassis. The following figure shows the symbols that indicate the slot types. Figure 2. Chassis Compatibility Symbols NI PXIe-1062Q 1 2 3 4 5 1. PXI Express System Controller Slot 2. PXI Peripheral Slot 3. PXI Express Hybrid Peripheral Slot 4. PXI Express System Timing Slot 5. PXI Express Peripheral Slot NI 4080/4081/4082 modules can be placed in PXI Express peripheral slots, PXI Express hybrid peripheral slots, or PXI Express system timing slots. 6. Touch any metal part of the chassis to discharge static electricity. 7. Ensure that the ejector handle is in the downward (unlatched) position. 8. Place the module edges into the module guides at the top and bottom of the chassis. Slide the module into the slot until it is fully inserted. NI PXIe-4080/4081/4082 Getting Started Guide National Instruments 5

Figure 3. Module Installation 1 NI PXIe-1075 2 3 1. Chassis 2. Hardware Module 3. Ejector Handle in Downward (Unlatched) Position 9. Latch the module in place by pulling up on the ejector handle. 10. Secure the module front panel to the chassis using the front-panel mounting screws. Note Tightening the top and bottom mounting screws increases mechanical stability and also electrically connects the front panel to the chassis, which can improve the signal quality and electromagnetic performance. 11. Cover all empty slots using EMC filler panels or fill using slot blockers to maximize cooling air flow, depending on your application. 12. Power on the chassis. Hardware Front Panel Connectors Refer to the following figure for the NI 4080/4081/4082 front panels. The front panels have four shrouded banana plug connectors. 6 ni.com NI PXIe-4080/4081/4082 Getting Started Guide

PXIe-4080 6½-Digit DMM PXIe-4081 7½-Digit DMM PXIe-4082 6½-Digit DMM 300 V INPUT V Ω 1k V INPUT INPUT 300 V V Ω V Ω 1A 3A 1A AMPS AMPS AMPS SENSE Ω 4 W SENSE Ω 4 W SENSE Ω 4 W 300 V 500 V 300 V 1000 V CAT I 300 V CAT II 500 V CAT II 300 V CAT II Connecting Signals The following figures show how to connect signals to the DMM front panel connectors for common measurements. For more information about these common measurements, refer to the NI Digital Multimeters Help at ni.com/manuals. Caution Always refer to the device specifications before connecting signals. Failure to observe the specified maximum signal ratings can cause shock, a fire NI PXIe-4080/4081/4082 Getting Started Guide National Instruments 7

hazard, or damage to the devices connected to the DMM. NI is not liable for any damage or injuries resulting from incorrect signal connections. Figure 4. DC and AC Voltage DC or AC Figure 5. DC and AC Current 8 ni.com NI PXIe-4080/4081/4082 Getting Started Guide

Figure 6. 2-Wire and 4-Wire Resistance Note 4-wire resistance measurements use both pairs of terminals. Use the configuration to measure low resistances accurately by eliminating the effects of lead resistance. Figure 7. Capacitance and Inductance + NI PXIe-4080/4081/4082 Getting Started Guide National Instruments 9

Figure 8. Voltage Drop Across a Diode + Requirements for Cables and Probes The DMM shipping kit contains a pair of test probes with safety banana plugs. These probes meet international safety requirements, including UL 3111 and IEC-1010-1, for the full range of applications supported by the DMM. Caution Before using any probes or accessories, ensure that they meet applicable safety requirements for the signal levels you may encounter. Connect the test probes to the banana plug connectors on the DMM front panel using safety banana plugs. The shrouds around the banana plugs prevent you from contacting potentially hazardous voltages connected to the test probes. You can also connect the cable to standard, unshrouded banana plug probes or accessories. Use unshrouded probes or accessories only when the voltages are less than 30 Vrms and 42 Vpk, or 60 VDC. Caution (NI 4081 users) To prevent possible safety hazards, the maximum voltage between any of the inputs and the ground of the PXI Express chassis is 500 VDC or 500 Vrms (sine wave), except between the terminal and ground, where the maximum voltage is 1,000 VDC or700 Vrms (sine wave). The maximum current the NI 4081 can measure through the current inputs is ±3 ADC or 3 Arms. Caution (NI 4080/4082 users) To prevent possible safety hazards, the maximum voltage between any of the inputs and the ground of the computer is 300 VDC or 300 Vrms. The maximum current the NI 4080/4082 can measure through the current inputs is ±1 ADC or 1 Arms. 10 ni.com NI PXIe-4080/4081/4082 Getting Started Guide

Configuring the NI 4080/4081/4082 in Use Measurement & Automation Explorer () to configure your NI hardware. informs other programs about which NI hardware products are in the system and how they are configured. is automatically installed with NI-DMM. 1. Launch. 2. In the configuration tree, expand Devices and Interfaces to see the list of installed NI hardware. Installed modules appear under the name of their associated chassis. 3. Expand your Chassis tree item. lists all modules installed in the chassis. Your default names may vary. Note If you do not see your module listed, press <F5> to refresh the list of installed modules. If the module is still not listed, power off the system, ensure the module is correctly installed, and restart. 4. Record the identifier assigns to the hardware. Use this identifier when programming the NI 4080/4081/4082. 5. Self-test the hardware by selecting the item in the configuration tree and clicking Self- Test in the toolbar. The self-test performs a basic verification of hardware resources. Programming the NI 4080/4081/4082 You can acquire data interactively using the NI-DMM Soft Front Panel (SFP), or you can use the NI-DMM instrument driver to program your device in the supported ADE of your choice. NI PXIe-4080/4081/4082 Getting Started Guide National Instruments 11

Table 1. NI-DMM Programming Options Application Programming Interface (API) NI-DMM Soft Front Panel (SFP) Location Available from the start menu at Start»All Programs»National Instruments»NI-DMM» NI-DMM Soft Front Panel. Description The NI-DMM SFP allows users to take measurements and to test the functionality of NI DMM devices. The NI-DMM SFP provides an interface that allows users to interact with an NI DMM as if it were a traditional benchtop instrument. If you have multiple NI DMM devices, you can run multiple sessions of the NI-DMM SFP simultaneously. 12 ni.com NI PXIe-4080/4081/4082 Getting Started Guide

Table 1. NI-DMM Programming Options (Continued) Application Programming Interface (API) NI-DMM Instrument Driver Location LabVIEW Available on the LabVIEW Functions palette at Measurement I/O»NI-DMM. C or LabWindows/CVI Available at Program Files»IVI Foundation» IVI»Drivers»niDMM Description NI-DMM configures and operates the device hardware and performs basic acquisition and measurement options using LabVIEW VIs or LabWindows/CVI functions. NI-DMM Examples Microsoft Visual C/C++ Use examples located in the <NIDocDir>\NI-DMM \examples directory, where <NIDocDir> is one of the following directories: Windows 8/7/Vista Users\Public \Documents \National Instruments Windows XP Documents and Settings\All Users\Shared Documents \National Instruments You can modify an NI-DMM C example to create an application with Microsoft Visual C/C++. Copy an NI-DMM example to copy required project settings for include paths and library files. Alternatively, refer to the Using NI-DMM in Visual C++ topic of the NI Digital Multimeters Help to manually add all required include and library files to your project. The NI Example Finder is a utility available for some ADEs that organizes examples into categories and allows you to easily browse and search installed examples. You can see descriptions and compatible hardware models for each example, or see all the examples compatible with one particular hardware model. To locate examples, refer to the following table. NI PXIe-4080/4081/4082 Getting Started Guide National Instruments 13

Table 2. Locating NI-DMM Examples Application Development Environment (ADE) LabVIEW or LabWindows/CVI ANSI C or Visual Basic Location Locate examples with the NI Example Finder. Within LabVIEW or LabWindows/CVI, select Help»Find Examples, and navigate to Hardware Input and Output»Modular Instruments»NI- DMM (Digital Multimeters). Locate examples in the <NIDocDir>\NI DMM\examples directory, where <NIDocDir> is one of the following directories: Windows 8/7/Vista Users\Public\Public Documents\National Instruments Windows XP Documents and Settings\All Users \Shared Documents\National Instruments Troubleshooting If an issue persists after you complete a troubleshooting procedure, contact NI technical support or visit ni.com/support. What Should I Do if the NI 4080/4081/4082 Doesn't Appear in? 1. In the configuration tree, expand Devices and Interfaces. 2. Expand the Chassis tree to see the list of installed hardware, and press <F5> to refresh the list. 3. If the module is still not listed, power off the system, ensure that all hardware is correctly installed, and restart the system. 4. Navigate to the Device Manager. Operating System Windows 10/8.1 Windows 7 Description Right-click the Start button, and select Device Manager. Select Start»Control Panel»Device Manager. 5. If you are using a PXI or PXI Express controller, verify that a National Instruments entry appears in the System Devices list. Reinstall NI-DMM and the module if error conditions appear in the list. If you are using an MXI controller, right-click PCI-to-PCI Bridge, and select Properties from the shortcut menu to verify that the bridge is enabled. 14 ni.com NI PXIe-4080/4081/4082 Getting Started Guide

What Should I Do if the Module Fails the Self-Test? 1. Restart the system. 2. Launch, and perform the self-test again. 3. Power off the chassis. 4. Reinstall the failed module in a different slot. 5. Power on the chassis. 6. Perform the self-test again. Where to Go Next Refer to the following figure for information about other product tasks and associated resources for those tasks. Located online at ni.com/manuals EXPRE the application development environment (ADE) for your application. Located using the NI Example Finder LEARN about hardware features or review device specifications. CREATE custom applications within an application programming interface (API). Getting Started with LabVIEW Getting Started with LabWindows/CVI NI PXIe-4080 Specifications* OR NI PXIe-4081 Specifications* OR NI PXIe-4082 Specifications* NI Digital Multimeters Help* NI-DMM Soft Front Panel NI-DMM Instrument Driver NI-DMM Examples* NI Digital Multimeters Help* DISCOVER more about your products through ni.com. Support ni.com/support NI Digital Multimeters ni.com/digitalmultimeters Services ni.com/services NI Community ni.com/community *This item is also installed with the driver software. Worldwide Support and Services The NI website is your complete resource for technical support. At ni.com/support, you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. NI PXIe-4080/4081/4082 Getting Started Guide National Instruments 15

Visit ni.com/services for NI Factory Installation Services, repairs, extended warranty, and other services. Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI. A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European Communities using the manufacturer s declaration of conformity. This system affords the user protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC for your product by visiting ni.com/certification. If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration. NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI also has offices located around the world. For telephone support in the United States, create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the Worldwide Offices section of ni.com/ niglobal to access the branch office websites, which provide up-to-date contact information, support phone numbers, email addresses, and current events. Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/ legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. 2015 2016 National Instruments. All rights reserved. 375250B-01 Oct16